Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 200
Filtrar
1.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38857196

RESUMO

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Assuntos
Materiais Dentários , Polimento Dentário , Vapor , Esterilização , Propriedades de Superfície , Zircônio , Esterilização/métodos , Humanos , Polimento Dentário/métodos , Teste de Materiais/métodos , Restauração Dentária Permanente/métodos , Microscopia Eletrônica de Varredura/métodos
2.
Med Sci Monit ; 30: e943706, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38500254

RESUMO

BACKGROUND The advent of digital impressions using computer-aided design and manufacturing technology (CAD/CAM) has simplified and improved the fabrication of implant prostheses in dentistry. The conventional impression has several drawbacks, including tray selection, material type, impression technique, impression disinfection, and cast model storage. The inaccuracies caused by distortion and contraction of impression material can be minimized with digital impressions. This study aimed to compare digital dental impressions of 10 working casts made using the Pindex laser removable die system to fabricate parallel drill channels vs 10 working casts made using the Di-Lok plastic tray removable die system. MATERIAL AND METHODS An implant master die with 2 dental implant analogs was fabricated. Ten working casts using the Pindex laser removable die system with parallel drill channels and 10 working casts using the Di-Lok plastic tray removable die system were fabricated. The working casts were scanned using an extra-oral laboratory scanner and the implant master model was scanned with an intra-oral scanner. RESULTS The properties of the casts made using the 2 systems were evaluated and analyzed with ANOVA and post hoc Tukey test. The mean horizontal linear distances between A1B1 (P<0.021), A2B2 (P<0.018), C1D1 (P<0.026), C2D2 (P<0.03), B1C1 (P<0.01), and mean vertical distances between B1A2 (P<0.015), C1D2 (P<0.001), B1B2 (P<0.028), and C1C2 (P<0.001) were significantly different between the Pindex system and Di-Lok tray system as compared to intra-oral scans. CONCLUSIONS Complete digital workflow with intra-oral scans were more than the partial digital workflow with extra-oral scans for the Pindex system and Di-Lok tray systems.


Assuntos
Implantes Dentários , Modelos Dentários , Fluxo de Trabalho , Desenho Assistido por Computador , Prótese Parcial Fixa , Projetos de Pesquisa
3.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38444156

RESUMO

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Assuntos
Cimentos de Ionômeros de Vidro , Boca , Zircônio , Membrana Celular , Coroas
4.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762747

RESUMO

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Assuntos
Materiais para Moldagem Odontológica , Glutaral , Teste de Materiais , Polivinil , Siloxanas , Materiais para Moldagem Odontológica/química , Polivinil/química , Siloxanas/química , Fatores de Tempo , Glutaral/química , Desinfetantes de Equipamento Odontológico/química , Hipoclorito de Sódio/química , Desinfetantes/química , Clorexidina/química , Propriedades de Superfície , Humanos
5.
Neurosciences (Riyadh) ; 29(3): 190-196, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38981634

RESUMO

OBJECTIVES: To develop a machine learning model to accurately predict stroke risk based on demographic and clinical data. It also sought to identify the most significant stroke risk factors and determine the optimal machine learning algorithm for stroke prediction. METHODS: This cross-sectional study analyzed data on 438,693 adults from the 2021 Behavioral Risk Factor Surveillance System. Features encompassed demographics and clinical factors. Descriptive analysis profiled the dataset. Logistic regression quantified risk relationships. Adjusted mutual information evaluated feature importance. Multiple machine learning models were built and evaluated on metrics like accuracy, AUC ROC, and F1 score. RESULTS: Key factors significantly associated with higher stroke odds included older age, diabetes, hypertension, high cholesterol, and history of myocardial infarction or angina. Random forest model achieved the best performance with accuracy of 72.46%, AUC ROC of 0.72, and F1 score of 0.74. Cross-validation confirmed its reliability. Top features were hypertension, myocardial infarction history, angina, age, diabetes status, and cholesterol. CONCLUSION: The random forest model robustly predicted stroke risk using demographic and clinical variables. Feature importance highlighted priorities like hypertension and diabetes for clinical monitoring and intervention. This could help enable data-driven stroke prevention strategies.


Assuntos
Aprendizado de Máquina , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/epidemiologia , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Adulto , Idoso , Fatores de Risco , Análise Multivariada
6.
Med Sci Monit ; 29: e941793, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37822073

RESUMO

BACKGROUND We investigated the bond strength, tensile strength, and water absorption properties of 4 widely used chairside silicone long-term denture soft lining materials and compared properties with those of heat-cured silicone material. MATERIAL AND METHODS Four chairside materials (GC Reline Soft, Mucopren Soft, Sofreliner Soft, and Elite Soft Relining) and a heat-cured silicone material (Molloplast B) were investigated. For tensile and shear bond strength and tensile strength, samples were prepared according to the manufacturers' instructions and the testing machine used. For water absorption, IOS 1567 was followed to prepare specimens. Bond strengths were measured using a Lloyd Instruments materials testing machine. Ten specimens for each test were prepared for each soft liner, except for water absorption and solubility tests, for which only 5 specimens were prepared. ANOVA, Bonferroni, and Kruskal-Wallis tests were used to compare values of materials and assess changes over time. RESULTS There was strong evidence of differences in the properties between materials. GC Reline Soft showed comparable tensile bond (1.4±0.6 MPa), shear bond (1.1±0.4 MPa), tensile strength (5.44±0.98), water absorption (0.92±0.2 µg/mm³), and solubility values (0.3±0.2 µg/mm3) to that of Molloplast B (1.4±0.4; 1.6±0.5; 4.53±0.9 MPa, 1.7±0.3, and 1.0±0.3 µg/mm³, respectively). The water solubility of Sofreliner Soft was significantly lower (1.5±0.8 µg/mm³) than that of Molloplast B. CONCLUSIONS There were significant differences between some properties of 4 chairside denture soft lining materials and that of Molloplast B, which had higher shear and tensile bond strength than chairside denture silicone soft lining materials but had the highest water solubility.


Assuntos
Colagem Dentária , Reembasadores de Dentadura , Temperatura Alta , Teste de Materiais , Elastômeros de Silicone/química , Água , Resistência à Tração , Bases de Dentadura , Propriedades de Superfície
7.
Med Sci Monit ; 29: e938672, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36808113

RESUMO

BACKGROUND A dental dam is a protective sheet with an aperture and is used to prevent the spread of infection during dental procedures. This study aimed to use a 2-part online questionnaire to evaluate the attitudes and use of rubber dental dams by 300 Saudi dental interns, general dental practitioners, residents, specialists, and consultants in prosthodontics, endodontics, and restorative dentistry. MATERIAL AND METHODS The 17-item validated questionnaire consisted of 5 questions on demographics, 2 on knowledge, 6 on attitudes, and 4 on perceptions. It was distributed through Google Forms. The chi-square test was used to determine the associations between the study variables and perception questions. RESULTS A total of 41.67% participants were specialists/consultants, among which 59.2% were in the prosthodontics specialty, 12.8% in endodontics, and 28% in restorative dentistry. Most participants (84.67%) stated the necessity of using rubber dams during post and core procedures. A total of 53.67% had received enough training for using rubber dams during their undergraduate/residency education. The majority of participants (41%) also preferred using rubber dams during the prefabricated post and core procedures, and 28.33% stated that the remaining tooth structure was one of the major reasons for not using rubber dams during the post and core procedures. CONCLUSIONS Workshops and hands-on training should be conducted among dental graduates to instill a positive attitude regarding the use of rubber dams.


Assuntos
Odontólogos , Diques de Borracha , Humanos , Arábia Saudita , Padrões de Prática Odontológica , Papel Profissional , Inquéritos e Questionários
8.
Med Sci Monit ; 29: e940573, 2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37381591

RESUMO

BACKGROUND This study, employing an online questionnaire, aimed to assess and contrast the awareness, knowledge, and perceptions of dentists in Saudi Arabia (SA) regarding endocrowns (EC) as post-endodontic restorations with those of dentists educated in various other countries. MATERIAL AND METHODS We conducted a cross-sectional survey among dental interns and practicing dentists in government facilities, private dental centers, and dental colleges in SA, including participants of diverse nationalities. We disseminated validated, closed-ended questionnaires through WhatsApp via Google Forms. The Chi-square test was applied to assess associations between categorical variables, with a P-value of ≤0.05 indicating statistical significance. RESULTS The majority of participants (61.2%) indicated that EC restorations are best suited for molar teeth. Furthermore, 69.6% asserted that the primary objective of employing EC is to accomplish minimally invasive preparations while preserving the existing tooth structure. Among the responses, 68.3% pinpointed debonding of ECs as a significant cause of failure. Notably, substantial differences were observed in responses concerning the knowledge or practice of EC across various factors such as gender, educational attainment, country of graduation, and workplace. CONCLUSIONS The findings reveal a comparatively low adoption of ECs among the participants, irrespective of experience or country of education. This underscores the need for incorporating ECs into dental curricula through theoretical and clinical discussions or considering them as a subject for post-graduate continuing education programs.


Assuntos
Currículo , Dente Molar , Humanos , Estudos Transversais , Escolaridade , Odontólogos
9.
Med Sci Monit ; 29: e941654, 2023 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-37924203

RESUMO

BACKGROUND The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast. MATERIAL AND METHODS Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (control group). Opposing mandibular casts obtained from three different impression materialsand 3-dimensional print constituted test groups , ,and , respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P≤0.05 using the single-sample t test, ANOVA, and Tukey test. RESULTS The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the error of means among the 4 tested groupswere detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences. CONCLUSIONS The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.


Assuntos
Modelos Dentários , Impressão Tridimensional , Humanos , Alginatos , Mandíbula , Software
10.
Sensors (Basel) ; 23(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37765970

RESUMO

This paper presents a comprehensive study on the classification of brain tumor images using five pre-trained vision transformer (ViT) models, namely R50-ViT-l16, ViT-l16, ViT-l32, ViT-b16, and ViT-b32, employing a fine-tuning approach. The objective of this study is to advance the state-of-the-art in brain tumor classification by harnessing the power of these advanced models. The dataset utilized for experimentation consists of a total of 4855 images in the training set and 857 images in the testing set, encompassing four distinct tumor classes. The performance evaluation of each model is conducted through an extensive analysis encompassing precision, recall, F1-score, accuracy, and confusion matrix metrics. Among the models assessed, ViT-b32 demonstrates exceptional performance, achieving a high accuracy of 98.24% in accurately classifying brain tumor images. Notably, the obtained results outperform existing methodologies, showcasing the efficacy of the proposed approach. The contributions of this research extend beyond conventional methods, as it not only employs cutting-edge ViT models but also surpasses the performance of existing approaches for brain tumor image classification. This study not only demonstrates the potential of ViT models in medical image analysis but also provides a benchmark for future research in the field of brain tumor classification.

11.
Molecules ; 28(6)2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36985728

RESUMO

Toxic chemicals such as carbon tetrachloride and thioacetamide (TAA) are reported to induce hepato-nephrotoxicity. The potential protective outcome of the antidiabetic and pleiotropic drug metformin against TAA-induced chronic kidney disease in association with the modulation of AMP-activated protein kinase (AMPK), oxidative stress, inflammation, dyslipidemia, and systemic hypertension has not been investigated before. Therefore, 200 mg/kg TAA was injected (via the intraperitoneal route) in a model group of rats twice a week starting at week 3 for 8 weeks. The control rats were injected with the vehicle for the same period. The metformin-treated group received 200 mg/kg metformin daily for 10 weeks, beginning week 1, and received TAA injections with dosage and timing similar to those of the model group. All rats were culled at week 10. It was observed that TAA induced substantial renal injury, as demonstrated by significant kidney tissue damage and fibrosis, as well as augmented blood and kidney tissue levels of urea, creatinine, inflammation, oxidative stress, dyslipidemia, tissue inhibitor of metalloproteinases-1 (TIMP-1), and hypertension. TAA nephrotoxicity substantially inhibited the renal expression of phosphorylated AMPK. All these markers were significantly protected by metformin administration. In addition, a link between kidney fibrosis and these parameters was observed. Thus, metformin provides profound protection against TAA-induced kidney damage and fibrosis associated with the augmentation of the tissue protective enzyme AMPK and inhibition of oxidative stress, inflammation, the profibrogenic gene TIMP-1, dyslipidemia, and hypertension for a period of 10 weeks in rats.


Assuntos
Dislipidemias , Hipertensão , Metformina , Insuficiência Renal Crônica , Ratos , Animais , Metformina/farmacologia , Metformina/uso terapêutico , Proteínas Quinases Ativadas por AMP/metabolismo , Tioacetamida/toxicidade , Inibidor Tecidual de Metaloproteinase-1/metabolismo , Regulação para Cima , Regulação para Baixo , Estresse Oxidativo , Inflamação/metabolismo , Insuficiência Renal Crônica/metabolismo , Fibrose , Hipertensão/induzido quimicamente , Hipertensão/tratamento farmacológico , Hipertensão/metabolismo , Dislipidemias/induzido quimicamente , Dislipidemias/tratamento farmacológico , Dislipidemias/metabolismo , Fígado/metabolismo , Cirrose Hepática/tratamento farmacológico
12.
BMC Oral Health ; 23(1): 564, 2023 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-37574557

RESUMO

BACKGROUND: Developing efficient bonding techniques for orthodontic brackets and all-ceramic materials continues to pose a clinical difficulty. This study aimed to evaluate the shear bond strengths (SBS) of metal and ceramic brackets to various all-ceramic CAD-CAM materials, such as lithium disilicate CAD (LDS-CAD), polymer-infiltrated ceramic (PIC), zirconia-reinforced lithium silicate glass ceramic (ZLS), and 5YTZP zirconia after different surface treatments and thermal cycling. MATERIALS AND METHODS: The samples were divided into two groups to be bonded with ceramic and metal lower incisor brackets. Each group was subdivided into a control group devoid of any surface treatment, 10% HF acid (HFA) etching, ceramic etch & prime (MEP), Al2O3 air abrasion, and medium grit diamond bur roughening. After surface treatment, brackets were bonded with composite resin cement, thermal cycled, and tested for shear bond strength. The failed surfaces were evaluated with a digital microscope to analyse the type of failure. The data were statistically analysed using a one-way ANOVA and Tukey HSD tests at p < 0.05. RESULTS: The highest mean bond strengths were found with HFA etching in LDS-CAD (13.17 ± 0.26 MPa) and ZLS (12.85 0.52 MPa). Diamond bur recorded the lowest mean bond strength roughening across all the ceramic groups. There were significant differences in mean shear bond values per surface treatment (p < 0.001) and ceramic materials. CONCLUSION: Among the surface treatment protocols evaluated, HFA etching and MEP surface treatment resulted in enhanced bond strength of both ceramic and metal brackets to CAD-CAM all ceramic materials.


Assuntos
Colagem Dentária , Braquetes Ortodônticos , Humanos , Abrasão Dental por Ar , Colagem Dentária/métodos , Propriedades de Superfície , Cerâmica/química , Cimentos de Resina/química , Desenho Assistido por Computador , Diamante , Teste de Materiais , Resistência ao Cisalhamento
13.
Medicina (Kaunas) ; 59(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36984502

RESUMO

The coronal seal in root canal-treated teeth may be compromised depending on the accuracy of post space preparation and post cementation along with remaining gutta-percha. Root canal treatment can be compromised by endotoxins released by the coronal bacteria as a result of microleakage. The study was conducted by undergraduate students to measure the gap between the cemented post and residual gutta-percha. In total, 217 endodontically treated teeth were evaluated with intraoral peri-apical radiographs. Based on the intraoral periapical radiographic examination in the CS-R4 program, Group I had no gap, Group II had a gap of >0 to 2 mm, and Group III had a gap of more than 2 mm between the end of the cemented post and the remaining gutta-percha. In total, 40% (n = 87) of the teeth had no gap, 59% (127) had a gap of >0 to 2 mm, and 1% (n = 3) had a gap of more than 2 mm between the cemented post end and remaining gutta. Chi square test revealed a significant difference in the gap between the post and remaining gutta-percha between males and females students (p < 0.001). In terms of the gap between the cemented post end and the residual gutta-percha, the root canal treated teeth with post and core by undergraduates were clinically acceptable.


Assuntos
Materiais Restauradores do Canal Radicular , Dente não Vital , Humanos , Guta-Percha , Estudos Transversais , Estudos Retrospectivos
14.
Saudi Pharm J ; 31(9): 101738, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37638213

RESUMO

Background: Rare diseases are chronic, serious, and life-threatening conditions that have not received sufficient attention from drug developers due to their rarity. Policies have been implemented to encourage research and incentivize the development of orphan drugs. However, the implementation of these policies has been inconsistent worldwide. Objective: The primary aim of this study was to compare orphan drug policies in the United States, Europe, and Saudi Arabia (SA) and assess their impact on the number of approved indications. Method: Lists of all drugs granted orphan designations and authorized for marketing in the United States, European Union, and SA were extracted using orphan drug lists available in regulatory body databases. The availability of these drugs, regarding their approval for orphan indication and designation, was assessed and classified using Anatomical Therapeutic Chemical codes. Result: A total of 792 orphan drug designations with at least one authorized indication were identified in this study. Of these, 92% were designated by the Food and Drug Administration (FDA), and 27% were designated by the European Medicine Agency (EMA). The FDA, EMA, and Saudi Food and Drug Authority approved 753, 435, and 253 orphan drugs, respectively. Conclusion: Fewer orphan drug approvals were found in SA than in the United States and Europe. This highlights the need to focus on rare diseases and orphan drugs and for policies to be created in SA to attract pharmaceutical markets and fulfill unmet orphan drug approval needs.

15.
Saudi Pharm J ; 31(11): 101822, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38023384

RESUMO

Background: Recently, there has been an increase in the incidence of colorectal cancer in Saudi Arabia. Although numerous studies worldwide have investigated the economic burden of colorectal cancer the information specific to Saudi Arabia remains limited. While advanced cancer treatments offer substantial benefits, they they also come with substantial financial challenges. Objective: This study aimed to estimate the economic burden of colorectal cancer and identify the primary cost drivers. Method: This retrospective, single-center cost of illness study examined all patients with colorectal cancer from January 2017 to December 2020. This study used a micro-costing, bottom-up approach to estimate healthcare resource utilization and direct medical costs associated with colorectal cancer. Result: The study included 326 patients with colorectal cancer. The total direct medical cost for all patients were $19 million, with an annual cost per patient of $58,384. Medication costs were the primary driver of healthcare spending (45%) of the total cost, followed by surgical costs (27%). This study explained cost associated with colorectal cancer, which represents a significant cost to the Saudi healthcare budget. The expected growth and aging of the population and availability of costly treatments may lead to an increase in costs. These findings are valuable for healthcare policymakers seeking to comprehend the economic challenges posed by colorectal cancer.

16.
Neurosciences (Riyadh) ; 28(4): 258-263, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37844941

RESUMO

OBJECTIVES: To investigate the prevalence and risk factors linked to contrast-induced nephropathy in this specific patient population, aiming to ensure the highest quality of clinical care. METHODS: In a retrospective analysis, all patients who presented with an acute stroke to King Fahad Hospital, Jeddah, Emergency Department from March until November 2022 and underwent Computed Tomography Angiography (CTA) brain, Inclusion criteria were as follows: a baseline creatinine results and CTA examination performed within 24 hours of symptom onset and an available early (<5 days after CTA) follow-up creatinine result. RESULTS: Among 246 stroke patients in the emergency, 182 underwent brain CTA and 8.24% had Contrast-Induced Nephropathy (CIN). intracerebral hemorrhage (ICH) increased CIN risk 7-fold (OR=6.7; 95% CI: 1.23-33.3). Abnormal baseline raised CIN risk 8-fold (OR=7.8; 95% CI: 1.74-35.1). hypertension doubled the risk for CIN (OR=2.1; 95% CI: 1.26-6.98) CONCLUSION: The incidence of CIN was 8.2%, particularly elevated in patients with ICH, hypertension, tissue plasminogen administration, and abnormal baseline, necessitating vigilance in managing acute stroke cases.


Assuntos
Hipertensão , Nefropatias , Acidente Vascular Cerebral , Humanos , Angiografia por Tomografia Computadorizada , Meios de Contraste/efeitos adversos , Incidência , Estudos Retrospectivos , Creatinina , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Nefropatias/diagnóstico , Hemorragia Cerebral/induzido quimicamente , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia
17.
Part Fibre Toxicol ; 19(1): 54, 2022 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-35933425

RESUMO

BACKGROUND: Metabolic syndrome (MetS) exacerbates susceptibility to inhalation exposures such as particulate air pollution, however, the mechanisms responsible remain unelucidated. Previously, we determined a MetS mouse model exhibited exacerbated pulmonary inflammation 24 h following AgNP exposure compared to a healthy mouse model. This enhanced response corresponded with reduction of distinct resolution mediators. We hypothesized silver nanoparticle (AgNP) exposure in MetS results in sustained pulmonary inflammation. Further, we hypothesized treatment with resolvin D1 (RvD1) will reduce exacerbations in AgNP-induced inflammation due to MetS. RESULTS: To evaluate these hypotheses, healthy and MetS mouse models were exposed to vehicle (control) or AgNPs and a day later, treated with resolvin D1 (RvD1) or vehicle (control) via oropharyngeal aspiration. Pulmonary lung toxicity was evaluated at 3-, 7-, 14-, and 21-days following AgNP exposure. MetS mice exposed to AgNPs and receiving vehicle treatment, demonstrated exacerbated pulmonary inflammatory responses compared to healthy mice. In the AgNP exposed mice receiving RvD1, pulmonary inflammatory response in MetS was reduced to levels comparable to healthy mice exposed to AgNPs. This included decreases in neutrophil influx and inflammatory cytokines, as well as elevated anti-inflammatory cytokines. CONCLUSIONS: Inefficient resolution may contribute to enhancements in MetS susceptibility to AgNP exposure causing an increased pulmonary inflammatory response. Treatments utilizing specific resolution mediators may be beneficial to individuals suffering MetS following inhalation exposures.


Assuntos
Síndrome Metabólica , Nanopartículas Metálicas , Pneumonia , Animais , Citocinas/metabolismo , Modelos Animais de Doenças , Ácidos Docosa-Hexaenoicos , Inflamação/induzido quimicamente , Nanopartículas Metálicas/toxicidade , Camundongos , Pneumonia/induzido quimicamente , Prata/toxicidade
18.
Med Sci Monit ; 28: e936885, 2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35643724

RESUMO

BACKGROUND The study aimed to assess effect of smokeless tobacco (ST) immersion with thermocycling (TC) on color of Vita Classical shade-guide, surface roughness (Ra) and roughness depth (Rz), and compressive fracture force (CFF) of hybrid polymer-infiltrated-feldspathic ceramic (Vita Enamic), leucite-Feldspathic glass (Vitablocs® Mark II), and zirconia-reinforced lithium silicate (Vita Suprinity) CAD/CAM prosthetic ceramic materials. MATERIAL AND METHODS A 48 samples were milled from Vita Enamic, Vita mark II, and Vita Suprinity. VitaPan shade-guide, Ra, and Rz were registered before ST immersion. Then, the same parameters were recorded again after 15 days of ST staining with and without TC. CFFs and fracture modes of samples after 3 months of aging were documented. RESULTS A slight change was observed in VitaPan shade-guide. Ra and Rz of Vita Suprinity (VS) recorded the highest values among ceramic groups at 3 time intervals. Increases in Ra and Rz were observed after immersion and staining with TC. ANOVA and Bonferroni post hoc tests were used. Significant differences among and between groups were noticed only before immersion in ST and TC, with P value ³0.00. The highest mean value and SD of CFFs (MPa and Newton) were recorded in Vita Suprinity, followed by Vita Enamic (VE) and Vita mark II (VMII). Reparable fracture was higher in VMII and VS. CONCLUSIONS ST staining and TC caused color changes in VitaPan shade-guide and increases in Ra and Rz of tested materials, with highest and lowest values recorded in VS and VE. CFFs were marginally equal to clinically accepted values for VS and equal or slightly higher than the half values for VE and VMII groups.


Assuntos
Tabaco sem Fumaça , Cerâmica , Desenho Assistido por Computador , Imersão , Teste de Materiais
19.
Med Sci Monit ; 28: e936892, 2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35711131

RESUMO

BACKGROUND Miswak is a form of chewing stick used to clean teeth in different parts of the world, including Saudi Arabia. We present a description of the effects of miswak derivatives, namely toothpaste, mouthwash, and brushing sticks, on the mean color changes (DE00), compressive fracture resistance values, and fracture modes of polymer-based computer-aided design (CAD) and computer-aided manufactured (CAM) prosthetic materials. MATERIAL AND METHODS Eighty-one rectangular-shaped samples were prepared from lithium disilicate glass-ceramic (IPS e.max CAD), zirconia-reinforced lithium silicate (Vita Suprinity), and monochromatic tooth-colored feldspar (Vitablocs Mark II) CAD/CAM ceramics. The color parameters were recorded using spectrophotometer before and after exposing the specimens to the different miswak oral hygiene derivatives for 15 days. Compressive fracture resistance values and fracture types were also assessed, and statistical analysis was performed. RESULTS Vita Suprinity and Vitablocs Mark II miswak sticks had the highest ΔE00 values. Moreover, miswak mouthwash had the lowest ΔE00 values, with significant differences among groups. IPS e.max CAD miswak sticks had the highest mean values of compressive fracture. Vitablocs Mark II had the lowest values for mouthwash and toothpaste. Significant differences were found within the IPS e.max CAD group. Reparable fractures were found in IPS e.max CAD, while semi-reparable fractures were seen in other groups. CONCLUSIONS Most ΔE00 values were within the acceptable clinical range, with IPS e.max CAD showing superior color stability. The mouthwash group showed minimal ΔE00. IPS e.max CAD had the highest mean compressive fracture resistance values with reparable fracture types.


Assuntos
Antissépticos Bucais , Polímeros , Cerâmica , Cor , Desenho Assistido por Computador , Computadores , Porcelana Dentária , Teste de Materiais , Antissépticos Bucais/farmacologia , Propriedades de Superfície , Cremes Dentais
20.
Saudi Pharm J ; 30(5): 527-531, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35693432

RESUMO

Background: Capecitabine is one of the fluoropyrimidine anticancer agents which is extensively used in the management of colorectal cancer. We have noticed a discrepancy between the doses we are using in our patients and the recommended dosing regimen. Thus, this study aims to assess the pharmacokinetic parameters of capecitabine and its metabolites in colorectal cancer patients and report some clinical outcomes. Methods: This study is a prospective observational pharmacokinetic study. It was conducted at the Oncology Center at King Saud University Medical City. The study included adult patients who received capecitabine for any stage of colorectal cancer. Blood samples were collected following the oral administration of capecitabine. Capecitabine and its metabolites concentration in plasma were determined using HPLC and pharmacokinetic parameters were estimated using PKanalix software. Results: The study included 30 colorectal cancer patients with a mean age of 58 ± 9.5 years and ECOG Performance Status of 0-1. 60 % of the patients were in stage IV. The average total daily dose was 1265 ± 350 mg/m2/day. Cmax for capecitabine was 5.2 ± 1.3 µg/ mL and Tmax was 1 ± 0.25 h. AUClast for capecitabine was 28 ± 10 µg.h/ mL. Vdobs and Clobs for capecitabine were 186 ± 28 L and 775 ± 213 mL/min, respectively. Calculated half-life (t1/2) was 2.7 h. Half of our patients showed partial tumor response and 20% showed stable disease. Only two patients had to discontinue the treatment because of the toxicity. Conclusion: Despite using lower doses, capecitabine and its metabolites parameters were found to be similar to previous studies except for the longer half-life found in our patients. In addition, lower doses of capecitabine showed acceptable response rate which might indicate that higher doses are not always necessary to achieve desired therapeutic effect.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA