Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neurogastroenterol Motil ; 35(8): e14610, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37158374

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) tagging techniques have been applied to the GI tract to assess bowel contractions and content mixing. We aimed to evaluate the dependence of a tagging measurement (for assessing chyme mixing) on inter-observer variability in both the ascending colon (AC) and descending colon (DC) and to investigate the temporal variation and hence reliability of the colonic tagging technique by acquiring multiple measurements over time on healthy participants. METHODS: Two independent datasets of healthy adults were used for the retrospective inter-observer variability (Study 1: 13 datasets and Study 2: 31 datasets), and ten participants were scanned for the prospective temporal variation study following a 1 L mannitol oral preparation. All colonic tagging data were acquired on 3 T MRI scanners. The mean and the standard deviation (SD) maps were generated pixel-by-pixel using custom-written software in MATLAB. The colonic regions of interest were defined using MIPAV software. Bland-Altman plots and scatter plots were used for the inter-observer variability. The mean and SD of all repeated measures for each subject were calculated along with a one-way ANOVA to test for variations with time. RESULTS: Scatter plots and Bland-Altman plots showed a large range of data with low variation and small limits of agreements (<5% CoV). The intraclass correlation coefficient of inter-rater reliability was excellent and 0.97 or above for the AC and DC measurements for both datasets. The temporal variation study shows that there was no significant difference found between the multiple measures with time (p = 0.53, one-way repeated measures ANOVA test). CONCLUSIONS: MRI tagging technique can provide an assessment of colonic chyme mixing. The inter-observer study data showed high inter-rater agreement. The temporal variation study showed some individual variations with time suggesting multiple measurements may be needed to increase accuracy.


Assuntos
Imageamento por Ressonância Magnética , Adulto , Humanos , Voluntários Saudáveis , Estudos Prospectivos , Estudos Retrospectivos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos
2.
Frontline Gastroenterol ; 13(e1): e28-e34, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35812031

RESUMO

The use of cross-sectional imaging and ultrasonography has long complemented endoscopic assessment of inflammatory bowel disease (IBD). Clinical symptoms alone are often not enough to assess disease activity, so a reliance on non-invasive techniques is essential. In this paper, we aim to examine the current use of radiological modalities in aiding the management of patients with IBD. We focus on the various sections of the gastrointestinal tract and how different modalities can aid in assessing current disease state and response to treatments. We also have a look at how newer sequences in cross-sectional imaging and ultrasonography can allow for better differentiation of disease activity (ie, fibrotic vs inflammatory) as well improve evaluation of small bowel, colonic and perianal disease. Furthermore, we examine how advanced image processing has the potential to allow radiology to be a surrogate for biomarkers. An example of this is explored when reviewing the ability of MR sequences to quantify visceral fat, which potentially plays a role in determining disease activity in Crohn's disease. Lastly, we look into the expected role for artificial intelligence to be used as an adjunct to radiology to better improve IBD evaluation.

3.
Nutrients ; 13(10)2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34684627

RESUMO

Oral processing of food results in the formation of food boluses, which are then swallowed and reach the stomach for further digestion. The number, size and surface properties of the boluses will affect their processing and emptying from the stomach. Knowledge of these parameters, however, is incomplete due to limitations of the techniques used. In this work, non-invasive magnetic resonance imaging (MRI) was used for the first time to measure boluses in the stomach a few minutes after swallowing. Three groups of nine healthy participants were fed three different meals: chicken and roasted vegetables (Meal 1), bread and jam (Meal 2) and cheese and yogurt (Meal 3), and then, their stomach content was imaged. The median number of boluses within the stomach was 282, 106 and 9 for Meal 1, Meal 2 and Meal 3 (p < 0.0001) with an average volume of 0.47 mL, 2.4 mL and 13.6 mL, respectively (p < 0.0001). The cohesiveness as well as the meal composition seem to play a key role in the resulting boluses. These new in vivo data from undisturbed organ imaging can improve knowledge of the digestion process, which will, in turn, inform in vitro and in silico modelling of digestion, thus improving their in vitro/in vivo relevance.


Assuntos
Digestão , Conteúdo Gastrointestinal/diagnóstico por imagem , Refeições , Estômago/diagnóstico por imagem , Adulto , Animais , Pão , Queijo , Feminino , Esvaziamento Gástrico , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Período Pós-Prandial , Aves Domésticas , Estudos Retrospectivos , Verduras , Iogurte , Adulto Jovem
4.
Diagnostics (Basel) ; 11(10)2021 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-34679624

RESUMO

Endoscopy is the gold standard for objective assessment of colonic disease activity in inflammatory bowel disease (IBD). Non-invasive colonic imaging using bowel ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) may have a role in quantifying colonic disease activity. We reviewed the diagnostic accuracy of these modalities for assessment of endoscopically or histopathologically defined colonic disease activity in IBD. We searched Embase, MEDLINE, and the Web of Science from inception to 20 September 2021. QUADAS-2 was used to evaluate the studies' quality. A meta-analysis was performed using a bivariate model approach separately for MRI and US studies only, and summary receiver operating characteristic (ROC) curves were obtained. CT studies were excluded due to the absence of diagnostic test data. Thirty-seven studies were included. The mean sensitivity and specificity for MRI studies was 0.75 and 0.91, respectively, while for US studies it was 0.82 and 0.90, respectively. The area under the ROC curves (AUC) was 0.88 (95% CI, 0.82 to 0.93) for MRI, and 0.90 (95% CI, 0.75 to 1.00) for US. Both MRI and US show high diagnostic accuracy in the assessment of colonic disease activity in IBD patients.

5.
Dermatol Reports ; 12(3): 8774, 2020 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-33408841

RESUMO

Social media that is heavily used in Saudi Arabia has been linked to a negative impact on body image satisfaction. The objective of the current study was to examine the burden, determinants, and impacts of Body Dysmorphic Disorder (BDD) among a community sample of social media users in Saudi Arabia. The Internet-based cross-sectional study was conducted among social media users during January and February 2020. BDD was assessed using a validated BDD Questionnaire. A total of 1010 participants were included in the current analysis. A total of 42 (4.2%) met the criteria of BDD, with higher prevalence in younger participants. The defects of high concerns were skin disfigurements (64.2%) and hair issues (42.3%). BDD was significantly associated with spending a longer time on Snapchat and Instagram and less interest in religious topics. BDD group was more likely to compare their appearance with famous people in social media. BDD group reported more harassment and more history of psychiatric problems. There is a need to educate the public about the risk of BDD and to promote safe social networking.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA