Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Aging Dis ; 15(1): 408-420, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37307839

RESUMO

Catheter ablation is a well-established rhythm control therapy in atrial fibrillation (AF). Although the prevalence of AF increases dramatically with age, the prognosis and safety profile of index and repeat ablation procedures remain unclear in the older population. The primary endpoint of this study was to assess the arrhythmia recurrence, reablation and complication rates in older patients. Secondary endpoints were the identification of independent predictors of arrhythmia recurrence and reablation, including information on pulmonary vein (PV) reconnection and other atrial foci. Older (n=129, ≥70 years) and younger (n=129, <70 years) patients were compared using a propensity-score matching analysis based on age, gender, obesity, hypertension, dyslipidemia, diabetes mellitus, dilated left atrium, severe obstructive sleep apnea, cardiac disease, left systolic ventricular function, AF pattern and ablation technique. Arrhythmia recurrence and reablation were evaluated in both groups using a Cox regression analysis in order to identify predictors. During a 30-month follow-up period, there were no significant differences between older and younger patients in the arrhythmia-free survival (65.1% and 59.7%; log-rank test p=0.403) and complication (10.1% and 10.9%; p>0.999) rates after the index ablation. However, the reablation rate was significantly different (46.7% and 69.2%; p<0.05, respectively). In those patients who underwent reablation procedure (redo subgroups), there were no differences in the incidence of PV reconnection (38.1% redo-older and 27.8% redo-younger patients; p=0.556). However, the redo-older patients had lower reconnected PVs per patient (p<0.01) and lower atrial foci (2.3 and 3.7; p<0.01) than the redo-younger patients. A further important finding was that age was not an independent predictor of arrhythmia recurrence or reablation. Our data reveal that the AF index ablation in older patients had a similar efficacy and safety profile to younger patients. Therefore, age alone must not be considered a prognostic factor for AF ablation but the presence of limiting factors such as frailty and multiple comorbidities.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Idoso , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Reoperação , Átrios do Coração , Ablação por Cateter/efeitos adversos
2.
Pacing Clin Electrophysiol ; 36(8): 963-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23692289

RESUMO

BACKGROUND: The Quartet quadripolar lead (St. Jude Medical Inc., St. Paul, MN, USA) offers 10 different left ventricle pacing configurations that may further influence hemodynamic parameters compared to traditional bipolar pacing configurations. The purpose of this study was to evaluate whether pacing from additional quadripolar lead vectors could enhance cardiac output (CO). METHODS: For each patient, CO was measured in "no-pacing" and in all the 10 configurations available, within 7 days of implantation of the device. Tip-ring, tip-right ventricular coil (RVC), and ring-RVC vectors were considered as traditional vectors. The seven additional configurations available in the quadripolar lead were considered as nontraditional vectors. CO was measured by ECHO. The best configuration was defined as the one presenting the highest CO measurement within configurations, which have a capture threshold <3 V and a safety margin between the capture and the phrenic nerve stimulation thresholds. RESULTS: Fifty-one standard cardiac resynchronization therapy patients were enrolled. The mean of each patient's best CO obtained with traditional vectors was higher than the baseline nonpaced CO (4.16 L/min vs 3.64 L/min). The mean of each patient's best CO, including all 10 available configurations, was also higher than the baseline nonpaced CO (4.33 L/min vs 3.64 L/min). In addition, the mean of each patient's best CO obtained with the best configuration available through a quadripolar lead was better than the mean of each patient's best CO obtained with a traditional configuration. In 53% of patients, the best CO was obtained with a nontraditional vector unique to the quadripolar lead. CONCLUSIONS: A quadripolar lead offers multiple additional pacing options to increase CO acutely compared to conventional bipolar leads.


Assuntos
Débito Cardíaco , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/prevenção & controle , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
3.
Rev Esp Cardiol (Engl Ed) ; 76(11): 922-935, 2023 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37774946

RESUMO

INTRODUCTION AND OBJECTIVES: This article presents data on implantable cardioverter-defibrillator implants in Spain in 2022. METHODS: The data were collected from implantation centers, which voluntarily completed a data collection sheet during the implantation process, either manually or through a web page. RESULTS: In 2022, 170 hospitals participated in the registry. A total of 7693 forms were received compared with the 7970 reported by Eucomed (European Confederation of Medical Suppliers Associations), representing 96.5% of the devices. The total rate of registered implants was 162/million inhabitants (168 according to Eucomed), showing a slight increase compared with previous years. Disparities persisted among autonomous communities and Spain continued to have the lowest implantation rate among countries participating in Eucomed. CONCLUSIONS: The data from the registry for 2022 reflect the complete recovery of activity after the impact of the COVID-19 pandemic in 2020. Despite a slight improvement, there was no significant change in our position in Europe or in the substantial differences among autonomous communities.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Humanos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Pandemias , Sistema de Registros , Espanha/epidemiologia
4.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36155845

RESUMO

INTRODUCTION AND OBJECTIVES: This article presents the data corresponding to implantable cardioverter-defibrillator (ICD) implantations in Spain in 2021. METHODS: The data were drawn from implanting centers, which voluntarily completed a data collection sheet during the procedure. RESULTS: In 2021, 7496 implant data sheets were received, compared with 7743 reported by Eucomed (European Confederation of Medical Suppliers Associations), indicating that data were collected from 96.8% of the devices implanted in Spain. Data completion ranged from 99.9% for "name of implanting hospital" to 8.9% for "implanting hospital". In 2021, 199 hospitals participated in the registry, exceeding the figures of previous years, with around 170 participating hospitals. The total rate of registered implants was 158/million inhabitants (163 according to Eucomed), making 2021 the year with the highest activity. However, the registry continues to show significant differences among the various autonomous communities and the lowest implantation rate of all the European countries participating in Eucomed. CONCLUSIONS: The Spanish implantable cardioverter-defibrillator registry for 2021 recorded an increase in the number of ICD implantations, reflecting the recovery of hospital activity after the initial impact of the COVID-19 pandemic in 2020. Although the total number of implants has increased in Spain, figures are still much lower than the European Union average, with differences persisting among Spanish autonomous communities.

5.
J Clin Med ; 11(19)2022 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-36233729

RESUMO

Pulmonary vein (PV) isolation is a well-established rhythm control therapy in atrial fibrillation (AF). Currently, there is no consensus on which ablation technique to use for the first procedure, cryoballoon (CB) or radiofrequency (RF). A retrospective cohort study was conducted on 1055 patients who underwent a first ablation, to assess both techniques based on the need for reablation. Patients with CB (n = 557) and RF (n = 498) ablations were clinically characterized and the need for reablation during a 30-month follow-up was used as the primary endpoint. Independent variables were analyzed to identify potential predictors. The need for reablation was significantly lower in the CB group than in the RF group (hazard ratio = 0.45 and 95% confident interval = 0.32−0.61; p < 0.001); in both paroxysmal and persistent AF, using a full-adjusted regression Cox model by age, sex, smoking, hypertension, diabetes mellitus, dyslipidemia, severe obstructive sleep apnea, dilated left atrium, persistent AF and early recurrence. RF ablation, dilated left atrium, persistent AF and early recurrence were identified as independent predictors of reablation. In addition, the CB-redo subgroup had a lower PV reconnection than the RF-redo subgroup. In conclusion, CB ablation suggests a reduction in the need for reablation and lower PV reconnection during the follow-up than RF ablation.

6.
Rev Esp Cardiol (Engl Ed) ; 74(11): 971-982, 2021 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34583912

RESUMO

INTRODUCTION AND OBJECTIVES: We present the data corresponding to implantable cardioverter-defibrillator (ICD) implants in Spain in 2020. METHODS: The data in this registry were drawn from implantation centers, which voluntarily completed a data collection sheet. RESULTS: In 2020, 7056 implant sheets were received compared with 7106 reported by Eucomed (European Confederation of Medical Suppliers Associations), indicating that data were collected from 99% of the devices implanted in Spain. Completion of the implant sheet ranged from 99.8% for the field "name of the implanting hospital" to 2.6% for the variable "referral hospital". A total of 173 hospitals performed ICD implants and participated in the registry, which is a similar figure to that in 2019 (n=172). The total rate of registered implants was 149/million inhabitants (150 according to Eucomed), revealing a slight reduction in implants in Spain in 2020 as a result of the impact of the COVID-19 pandemic. This reduction was uneven among the autonomous communities. CONCLUSIONS: The Spanish Implantable Cardioverter Defibrillator Registry for 2020 shows an improvement in the rate of implants reported and a reduction in the number of ICD implants, which likely reflects the decrease in hospital activity not related to the treatment of COVID-19 infection. Similar to previous years, the total number of implants in Spain is still much lower than the average for the European Union, with an increase in the differences between Spanish autonomous communities.


Assuntos
COVID-19 , Cardiologia , Desfibriladores Implantáveis , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Humanos , Pandemias , Sistema de Registros , SARS-CoV-2
7.
JACC Clin Electrophysiol ; 7(6): 705-715, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33358670

RESUMO

OBJECTIVES: The study goal was to examine whether there are sex-related differences in the incidence of ventricular arrhythmias and mortality in CRT-defibrillator (CRT-D) recipients. BACKGROUND: Few studies have evaluated sex-related benefits of cardiac resynchronization therapy (CRT). Moreover, data on sex-related differences in the occurrence of ventricular tachyarrhythmias in this population are limited. METHODS: A multicenter retrospective study was conducted in 460 patients (355 male subjects and 105 female subjects) from the UMBRELLA (Incidence of Arrhythmia in Spanish Population With a Medtronic Implantable Cardiac Defibrillator Implant) national registry. Patients were followed up through remote monitoring after the first implantation of a CRT-D during a median follow-up of 2.2 ± 1.0 years. Sex differences were analyzed in terms of ventricular arrhythmia-treated incidence and death during the follow-up period, with a particular focus on primary prevention patients. RESULTS: Baseline New York Heart Association functional class was worse in women compared with that in men (67.0% of women in New York Heart Association functional class III vs. 49.7% of men; p = 0.003), whereas women had less ischemic cardiac disease (20.8% vs. 41.7%; p < 0.001). Female sex was an independent predictor of ventricular arrhythmias (hazard ratio: 0.40; 95% confidence interval: 0.19 to 0.86; p = 0.020), as well as left ventricular ejection fraction and nonischemic cardiomyopathy. Mortality in women was one-half that of men, although events were scarce and without significant differences (2.9% vs. 5.6%; p = 0.25). CONCLUSIONS: Women with left bundle branch block and implanted CRT have a lower rate of ventricular tachyarrhythmias than men. All-cause mortality in patients is, at least, similar between female and male subjects.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Arritmias Cardíacas , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
8.
Rev Esp Cardiol (Engl Ed) ; 73(12): 1026-1037, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33039380

RESUMO

INTRODUCTION AND OBJECTIVES: We present the data corresponding to implantable cardioverter-defibrillator (ICD) implants in Spain in 2019. METHODS: The data were drawn from implant centers voluntarily completing a data collection sheet. RESULTS: In 2019, 7003 implant sheets were received compared with the 7389 reported by Eucomed (European Confederation of Medical Suppliers Associations), indicating that data were collected from 94.8% of the devices implanted in Spain. Completion of the implant sheet ranged from 99.7% in the field "name of the implanting hospital" to 17.8% in the variable "reference hospital". In 2019, 172 hospitals performed ICD implants and participated in the registry, a figure similar to that of 2018 (173). The total rate of registered implants was 149/million inhabitants; the rate reported by Eucomed was 157. Although this value represents the highest in the historical series, it is still much lower than the average rate of ICD implants in Europe (303). CONCLUSIONS: The Spanish Implantable Cardioverter-Defibrillator Registry for 2019 reflects a growth in the number of ICD implants and is the year with the highest number of ICD implants in Spain. However, similar to previous years, the total number of implants in Spain is still much lower than the European Union average, with substantial differences between Spanish autonomous communities.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Europa (Continente)/epidemiologia , Humanos , Sistema de Registros , Espanha/epidemiologia
9.
Rev Esp Cardiol (Engl Ed) ; 72(12): 1054-1064, 2019 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31727564

RESUMO

INTRODUCTION AND OBJECTIVES: This article presents the data corresponding to automated implantable cardioverter-defibrillator (ICD) implants in Spain reported to the Spanish Registry in 2018. METHODS: The data in this registry include both primary implants and generator replacements and were gathered from a data collection sheet voluntarily completed by implantation centers. RESULTS: In 2018, 6421 implant sheets were received compared with 7077 reported by Eucomed (European Confederation of Medical Suppliers Associations). This represents data on 90.7% of the devices implanted in Spain. Compliance ranged between 99.6% for the field "name of the implanting hospital" and 12.4% for "population of residence". A total of 173 hospitals reported their data to the registry, representing a slight decrease compared with hospitals participating in 2017 (n=181). CONCLUSIONS: After the reduction in ICD implants in 2017, the number of implants increased in 2018, with the highest number of ICDs implanted in Spain. The total number of implants remains much lower than the European Union average, with substantial differences between autonomous communities.


Assuntos
Arritmias Cardíacas/terapia , Cardiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Eletrofisiologia/estatística & dados numéricos , Sistema de Registros , Sociedades Médicas , Coleta de Dados , Feminino , Humanos , Masculino , Estudos Retrospectivos , Espanha
10.
Rev Esp Cardiol (Engl Ed) ; 71(12): 1047-1058, 2018 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30420318

RESUMO

INTRODUCTION AND OBJECTIVES: The Spanish Automatic Defibrillator Registry has provided activity data since 2002. METHODS: The data in this registry are submitted by implantation centers that voluntarily complete a data collection sheet. RESULTS: During 2017, a total of 6273 implant sheets were received, compared with 6429 reported by Eucomed (European Confederation of Medical Suppliers Associations). Therefore, the registry contains data on 97.6% of the devices implanted in Spain. Compliance ranged from 99.7% for the field "name of the implanting hospital" to 46.1% for the variable "New York Heart Association functional class". A total of 181 hospitals reported data to the registry, representing an increase compared with the number of participating hospitals in 2016 (177) and in previous years (169 in 2015, 162 in 2014, 154 in 2013, and 153 in 2012). CONCLUSIONS: The number of implants per million inhabitants in Spain increased for several years but decreased in 2017. As in previous years, the total number of implants in Spain is still much lower than the European Union average, and the gap continues to widen. There are still substantial differences between autonomous communities.


Assuntos
Arritmias Cardíacas/terapia , Cardiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Técnicas Eletrofisiológicas Cardíacas/estatística & dados numéricos , Sistema de Registros , Sociedades Médicas , Arritmias Cardíacas/epidemiologia , Feminino , Humanos , Incidência , Masculino , Estudos Retrospectivos , Espanha/epidemiologia
11.
JACC Cardiovasc Interv ; 5(5): 533-539, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22625192

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the need for a permanent pacemaker after transcatheter aortic valve implantation with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, Minnesota) using the new Accutrak delivery system (Medtronic, Inc.). BACKGROUND: The need for a permanent pacemaker is a recognized complication after transcatheter aortic valve implantation with the CoreValve prosthesis. METHODS: Between April 23, 2008 and May 31, 2011, 195 consecutive patients with symptomatic aortic valve stenosis underwent transcatheter aortic valve implantation using the self-expanding CoreValve prosthesis. In 124 patients, the traditional delivery system was used, and in 71 patients, the Accutrak delivery system was used. RESULTS: There were no significant differences in baseline electrocardiographic characteristics between the traditional system and the Accutrak patients: PR interval: 153 ± 46 mm versus 165 ± 30 mm, p = 0.12; left bundle branch block: 22 (20.2%) versus 8 (12.7%), p = 0.21; right bundle branch block: 21 (19.3%) versus 8 (12.7%), p = 0.26. The depth of the prosthesis in the left ventricular outflow tract was greater with the traditional system than with the Accutrak system (9.6 ± 3.2 mm vs. 6.4 ± 3 mm, p < 0.001) and the need for a permanent pacemaker was higher with traditional system than with Accutrak (35.1% vs. 14.3%, p = 0.003). The predictors of the need for a pacemaker were the depth of the prosthesis in the left ventricular outflow tract (hazard ratio [HR]: 1.2, 95% confidence interval [CI]: 1.08 to 1.34, p < 0.001), pre-existing right bundle branch block (HR: 3.5, 95% CI: 1.68 to 7.29, p = 0.001), and use of the traditional system (HR: 27, 95% CI: 2.81 to 257, p = 0.004). CONCLUSIONS: The new Accutrak delivery system was associated with less deep prosthesis implantation in the left ventricular outflow tract, which could be related to the lower rate of permanent pacemaker requirement.


Assuntos
Estenose da Valva Aórtica/terapia , Bloqueio de Ramo/terapia , Cateterismo Cardíaco/instrumentação , Estimulação Cardíaca Artificial , Catéteres , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Cateterismo Cardíaco/efeitos adversos , Distribuição de Qui-Quadrado , Eletrocardiografia , Desenho de Equipamento , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Espanha , Fatores de Tempo , Resultado do Tratamento
12.
Rev Esp Cardiol ; 63(12): 1444-51, 2010 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-21144405

RESUMO

INTRODUCTION AND OBJECTIVES: Although changes in atrioventricular conduction frequently occur after percutaneous implantation of an aortic valve prosthesis, little is known about the mechanisms involved or how these changes progress. We investigated ECG abnormalities and predictors of pacemaker need after percutaneous implantation of the CoreValve® aortic valve prosthesis. METHODS: Between April 2008 and October 2009, 65 patients with symptomatic severe aortic stenosis received a CoreValve® prosthesis. Clinical and ECG parameters were recorded and predictors of pacemaker need due to advanced atrioventricular block were investigated. The analysis excluded three patients because they had pacemakers and a fourth who died during the procedure. RESULTS: The patients' mean age was 79 ± 7.8 years and their logistic EuroSCORE was 20 ± 14%. Implantation was successful in 98.4%. After implantation, 47.5% had left bundle branch block and 21 patients (34.4%) required a permanent pacemaker. The need for a pacemaker was associated with a greater depth of prosthesis implantation in the left ventricular outflow tract (LVOT): 13 ± 2.5 mm vs. 8.8 ± 2.8 mm (P< .001). Moreover, depth was the only predictor: odds ratio 1.9, 95% confidence interval 1.19-3.05 (P< .007). A cutpoint of 11.1 mm for the prosthesis depth in the LVOT had a sensitivity of 81% and a specificity of 84.6% for predicting the need for a pacemaker. CONCLUSIONS: After CoreValve® aortic valve prosthesis implantation, a high percentage of patients needed a permanent pacemaker for advanced atrioventricular block. The only independent predictor was the depth of the prosthesis in the LVOT, which could serve as an early indicator of pacemaker need.


Assuntos
Valva Aórtica/cirurgia , Nó Atrioventricular/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Implante de Prótese de Valva Cardíaca , Marca-Passo Artificial , Idoso , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Bioprótese , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Valor Preditivo dos Testes
15.
Rev Esp Cardiol ; 61(4): 422-5, 2008 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-18405524

RESUMO

The aim of this study was to compare the effects of cardiac resynchronization therapy on left ventricular function and reverse remodeling in patients in sinus rhythm with the effects in patients with atrial fibrillation who have not undergone atrioventricular node ablation. Echocardiographic and clinical parameters were evaluated at baseline and after 6 months of cardiac resynchronization therapy in 55 patients: 15 had atrial fibrillation and 40 were in sinus rhythm. Device programming was similar in the 2 groups, as were the reductions in QRS interval and echocardiographic measures of asynchrony observed after implantation. However, although significant improvements in end-systolic volume and ejection fraction were seen in both groups, reverse remodeling was greater in patients in sinus rhythm (reduction in end-systolic volume 30.9%+/-24.6% vs 12.5%+/-18.6%; P=.024), as was the relative increase in ejection fraction (15.4%+/-12.6% vs 5.0%+/-7.2%; P=.010). Cardiac resynchronization therapy in patients with atrial fibrillation who had not undergone atrioventricular node ablation resulted in significant improvements in ejection fraction and reverse remodeling, but these were less than those observed in patients in sinus rhythm.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Ablação por Cateter , Idoso , Nó Atrioventricular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Função Ventricular Esquerda
17.
Europace ; 9(9): 757-61, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17573358

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) reduces the degree of functional mitral regurgitation (FMR). However, FMR has also been associated with a lack of clinical response to CRT. We undertook this study to determine whether the presence of FMR influences the reverse remodelling induced by CRT. METHODS AND RESULTS: We used Doppler echocardiography to assess 20 patients with dilated cardiomyopathy before and 6 months after undergoing CRT. We evaluated the effect of reverse remodelling (reduction > or = 10% in end-systolic volume) according to the presence or absence of important FMR, defined as a regurgitant orifice area (ROA) of > or = 0.20 cm(2). Of the 20 patients (mean age, 64.7 +/- 8.2 years, eight women), 9 had marked FMR (ROA 0.40 +/- 0.12 cm(2)), 6 mild FMR (ROA 0.15 +/- 0.02 cm(2)), and 5 had trivial or no FMR. CRT reduced the presence of mitral regurgitation by 33.3% and induced reverse remodelling in 60% of the patients. A ROA > or = 0.20 cm(2) was associated with a lack of reverse remodelling, despite presenting similar baseline characteristics and a reduction in asynchrony to the other patients. Reverse remodelling was produced in all the other patients, with a significant reduction in end-systolic volume (41.7 +/- 21%; P = 0.003), accompanied by improvement in the ejection fraction (P = 0.003) and myocardial performance index (P = 0.027). CONCLUSION: CRT improved FMR, although the baseline presence of important mitral regurgitation, with a ROA > or = 0.20 cm(2), in patients undergoing CRT was associated with a lack of response in reverse remodelling.


Assuntos
Estimulação Cardíaca Artificial , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Idoso , Ecocardiografia/métodos , Ecocardiografia Doppler , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Marca-Passo Artificial , Valor Preditivo dos Testes , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA