RESUMO
BACKGROUND: The purpose of this study was to assess by echocardiography the effects of lung transplantation on recovery of right ventricular (RV) function in patients with preoperative RV dysfunction. METHODS: Fourteen (20%) of 71 lung transplant recipients were identified by echocardiography as manifesting abnormal RV function before lung transplantation. These 14 patients were selected for follow-up echocardiographic study 8 months after transplantation. RESULTS: RV function improved significantly in the study group. Mean RV end-diastolic area decreased from 26.8 +/- 7.9 cm2 to 20.1 +/- 4.7 cm2 (P < 0.01); mean RV end-systolic area decreased from 21.5 +/- 6.8 cm2 to 13.1 +/- 4.2 (P < 0.01); and mean RV fractional area change (FAC) increased from 20.4 +/- 3.3% to 35.8 +/- 8.9% (P < 0.001). A subgroup of four patients, however, exhibited no change in RV function. Patients who achieved improvement in RV function tended to be younger, had shorter duration of disease before transplantation, and had higher pulmonary arterial (PA) pressures before transplantation (PA systolic, 89 +/- 28 mmHg vs. 38 +/- 11 mmHg, P < 0.001; PA diastolic, 42 +/- 11 mmHg vs. 19 +/- 3 mmHg, P < 0.002). Each of the eight patients with primary pulmonary hypertension exhibited improvement in RV function (mean delta FAC +20.6 +/- 5.9%), while two of three patients with emphysema and both patients with idiopathic pulmonary fibrosis failed to achieve improvement in RV function (mean delta FAC +2.3 +/- 1.2%). CONCLUSIONS: Improvement of RV function assessed by echocardiography occurs after lung transplantation, even in patients with severe preoperative RV dysfunction. However, the degree of improvement is variable and may depend on the degree of RV after-load reduction and the presence or absence of intrinsic myocardial disease. RV ejection parameters do not distinguish between these two possibilities.
Assuntos
Transplante de Pulmão , Disfunção Ventricular Direita , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Idoso , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
The frequency of right-to-left shunt through a patent foramen ovale is increased in hemodynamically stable patients without preexisting cardiopulmonary disease with acute pulmonary embolism. This is associated with a greater degree of perfusion abnormalities as quantified by perfusion scan and the presence of tricuspid regurgitation.
Assuntos
Comunicação Interatrial/fisiopatologia , Embolia Pulmonar/fisiopatologia , Doença Aguda , Adulto , Ecocardiografia , Feminino , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Cintilografia , Insuficiência da Valva Tricúspide/etiologia , Disfunção Ventricular Direita/diagnóstico por imagemRESUMO
BACKGROUND/OBJECTIVES: Patients presenting with acute pulmonary embolism associated with hemodynamic compromise exhibit right ventricular enlargement and dysfunction on transthoracic echocardiogram. However, the degree of echocardiographic abnormalities among hemodynamically stable patients without preexisting cardiopulmonary disease during the acute stage of pulmonary embolism, and following treatment, is unknown. Therefore, this study was designed to assess the extent of right ventricular abnormalities detected on transthoracic echocardiogram in patients following acute pulmonary embolism and during treatment with anticoagulation or vena caval interruption. The extent of pulmonary vascular obstruction and complication rate on follow-up were also assessed. DESIGN/INTERVENTIONS: Sixty-four consecutive hemodynamically stable patients without preexisting known cardiopulmonary disorder presenting with acute pulmonary embolism and undergoing treatment with anticoagulation or inferior vena caval interruption were studied. All subjects underwent a two-dimensional transthoracic echocardiogram within 24 h of diagnosis. The degree of perfusion abnormality on lung scan was quantified. Twenty-six patients underwent follow-up echocardiogram and lung scan at 6 weeks. The echocardiographic findings were compared with those obtained from a group of normal control subjects matched for gender and age. RESULTS: Although the mean right ventricular end-diastolic areas did not differ (21.9+/-5.2 cm2 vs 20.1+/-2.9 cm2 for control subjects; p=not significant), the right ventricular end-systolic area was larger in comparison to our series of control subjects (14.6+/-5.1 cm2 vs 11.7+/-2.0 cm2; p=0.025). Fractional right ventricular area change was reduced in the patient group compared with the control subjects (34.3+/-9.0% vs 41.3+/-7.0%; p=0.003). The extent of right ventricular end-systolic area enlargement and decrease in fractional area change did not correlate with the degree of pulmonary vascular obstruction. Patients who were restudied at 6 weeks showed minimal improvement in echocardiographic findings, despite almost complete resolution of perfusion defects on lung scan. CONCLUSIONS: The extent of right ventricular dysfunction in hemodynamically stable, previously normal patients with acute pulmonary embolism does not reflect the extent of the perfusion abnormalities. Further, right ventricular enlargement and systolic dysfunction are present and persistent despite treatment with heparin and warfarin therapy or vena caval interruption.
Assuntos
Hemodinâmica , Circulação Pulmonar , Embolia Pulmonar/fisiopatologia , Disfunção Ventricular Direita/complicações , Doença Aguda , Idoso , Ecocardiografia , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Cintilografia , Disfunção Ventricular Direita/diagnóstico por imagemRESUMO
The objective of this study was to prospectively assess pulmonary venous anastomosis by transesophageal echocardiography after lung transplantation. Thrombus formation at the pulmonary venous anastomotic site after lung transplantation may have catastrophic consequences, including allograft failure and stroke. Eighty-seven consecutive adult lung transplant recipients underwent transesophageal echocardiography within 48 hours after surgery. Thrombosis of a pulmonary vein was diagnosed in 13 (15%) of 87 patients in the early postoperative period after lung transplantation. Mean thrombus width was 0.9 +/- 0.4 cm (range, 0.5 to 1.7 cm), with an average peak flow velocity at the site of obstruction of 127 +/- 23 cm/s (range, 90 to 150 cm/s). Five patients with pulmonary vein thrombosis died in the perioperative period, yielding a 90-day mortality rate of 38%. Larger thrombus size and greater acceleration of flow through a narrowed pulmonary vein correlated with poor clinical outcome. During each year of the study, the incidence of pulmonary vein thrombosis declined progressively. Pulmonary vein thrombosis is a potentially ominous complication in the early postoperative period after lung transplantation. Transesophageal echocardiography is a valuable tool for detecting abnormalities of the pulmonary venous anastomosis. Thrombus size and flow velocity at the anastomotic site may guide prognosis and clinical management. Complications of the pulmonary venous anastomosis are in part technical in nature.