Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 48(2): 584-591, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32719914

RESUMO

BACKGROUND: The use of hybrid PET/MRI for clinical staging is growing in several cancer forms and, consequently, PET/MRI has also gained interest in the assessment of non-small cell lung cancer (NSCLC) and lung lesions. However, lung evaluation with PET/MRI is associated with challenges related to technical issues and diagnostic image quality. We, therefore, investigated the published literature on PET/MRI for clinical staging in NSCLC or lung nodule detection specifically addressing diagnostic accuracy and technical issues. METHODS: The data originates from a systematic search performed in PubMed/MEDLINE, Embase, and Cochrane Library on hybrid PET/MRI in patients with cancer for a scoping review published earlier ( https://doi.org/10.1007/s00259-019-04402-8 ). Studies in English and German evaluating the diagnostic performance of hybrid PET/MRI for NSCLC or lung nodule detection in cancer patients were selected. Data reported in peer-reviewed journals without restrictions to year of publication were included. RESULTS: A total of 3138 publications were identified from which 116 published 2012-2018 were included. Of these, nine studies addressed PET/MRI in NSCLC (4) or lung nodule detection (5). Overall, PET/MRI did not provide advantages in preoperative T- and N-staging in NSCLC compared to PET/CT. The data on M-staging were too few for conclusions to be drawn. The lung nodule detection rate of PET/MRI was comparable to that of PET/CT for FDG-avid nodules larger than 10 mm, but the sensitivity of PET/MRI for detection of non-FDG-avid nodules smaller than 5 mm was low. CONCLUSION: PET/MRI did not provide advantages in T- and N-staging of NSCLC compared to PET/CT. PET/MRI had a comparable sensitivity for detection of FDG-avid lung nodules and nodules over 10 mm, but PET/CT yielded a higher detection rate in non FDG-avid lung nodules under 5 mm. With PET/MRI, the overall detection rate for lung nodules in various cancer types remains inferior to that of PET/CT due to the lower diagnostic performance of MRI than CT in the lungs.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fluordesoxiglucose F18 , Humanos , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
2.
Eur J Nucl Med Mol Imaging ; 46(10): 2138-2151, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31267161

RESUMO

PURPOSE: PET/MRI was introduced for clinical use in 2011 and is now an established modality for the imaging of brain and certain pelvic cancers, whereas clinical use for the imaging of other forms of cancer is not yet widespread. We therefore systematically investigated what has been published on the use of PET/MRI compared to PET/CT in the imaging of cancers outside the brain, focusing on clinical areas of application related to diagnosis, staging and restaging. METHODS: A systematic search of PubMed/MEDLINE, Embase and the Cochrane Library was performed. Studies evaluating the diagnostic performance of simultaneous PET/MRI in cancer patients were chosen. RESULTS: A total of 3,138 publications were identified and 116 published during the period 2012-2018 were included and were grouped according to the major cancer forms: 13 head and neck (HNC), 9 breast (BC), 21 prostate (PC), 14 gynaecological, 13 gastrointestinal (GIC), and 46 various cancers. Data from studies comparing PET/MRI and PET/CT for staging/restaging suggested the superiority of 18F-FDG PET/MRI for the detection of tumour extension and retropharyngeal lymph node metastases in nasopharyngeal cancer, and for the detection of liver metastases and possibly bone marrow metastases in high-risk BC. FDG PET/MRI tended to be inferior for the detection of lung metastases in HNC and BC. 68Ga-PSMA-11 PET/MRI was superior to PET/CT for the detection of local PC recurrence. FDG PET/MRI was superior to FDG PET/CT for the detection of local tumour invasion in cervical cancer and had higher accuracy for the detection of liver metastases in colorectal cancer. CONCLUSION: The scoping review methodology resulted in the identification of a huge number of records, of which less than 5% were suitable for inclusion and only a limited number allowed conclusions on the advantages/disadvantages of PET/MRI compared to PET/CT in the oncological setting. There was evidence to support the use of FDG PET/MRI in staging of nasopharyngeal cancer and high-risk BC. Preliminary data indicate the superiority of PET/MRI for the detection of local recurrence in PC, local tumour invasion in cervical cancer, and liver metastases in colorectal cancer. These conclusions are based on small datasets and need to be further explored.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Ácido Edético/análogos & derivados , Fluordesoxiglucose F18 , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Imageamento por Ressonância Magnética/normas , Imagem Multimodal/normas , Metástase Neoplásica , Neoplasias/patologia , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos
5.
Diagnostics (Basel) ; 14(15)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39125466

RESUMO

The accurate estimation of the tracer arterial blood concentration is crucial for reliable quantitative kinetic analysis in PET. In the current work, we demonstrate the automatic extraction of an image-derived input function (IDIF) from a CT AI-based aorta segmentation subsequently resliced to a dynamic PET series acquired on a Siemens Vision Quadra long-axial field of view scanner in 10 human subjects scanned with [15O]H2O. We demonstrate that the extracted IDIF is quantitative and in excellent agreement with a delay- and dispersion-corrected sampled arterial input function (AIF). Perfusion maps in the brain are calculated and compared from the IDIF and AIF, respectively, showed a high degree of correlation. The results demonstrate the possibility of defining a quantitatively correct IDIF compared with AIFs from the new-generation high-sensitivity and high-time-resolution long-axial field-of-view PET/CT scanners.

6.
Front Nucl Med ; 4: 1360326, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39355217

RESUMO

Objective: We present an algorithm to estimate the delay between a tissue time-activity curve and a blood input curve at a single-voxel level tested on whole-body data from a long-axial field-of-view scanner with tracers of different noise characteristics. Methods: Whole-body scans of 15 patients divided equally among three tracers, namely [15O]H2O, [18F]FDG and [64Cu]Cu-DOTATATE, which were used in development and testing of the algorithm. Delay times were estimated by fitting the cumulatively summed input function and tissue time-activity curve with special considerations for noise. To evaluate the performance of the algorithm, it was compared against two other algorithms also commonly applied in delay estimation: name cross-correlation and a one-tissue compartment model with incorporated delay. All algorithms were tested on both synthetic time-activity curves produced with the one-tissue compartment model with increasing levels of noise and delays between the tissue activity curve and the blood input curve. Whole-body delay maps were also calculated for each of the three tracers with data acquired on a long-axial field-of-view scanner with high time resolution. Results: Our proposed model performs better for low signal-to-noise ratio time-activity curves compared to both cross-correlation and the one-tissue compartment models for non-[15O]H2O tracers. Testing on synthetically produced time-activity curves showed only a small and even residual delay, while the one-tissue compartment model with included delay showed varying residual delays. Conclusion: The algorithm is robust to noise and proves applicable on a range of tracers as tested on [15O]H2O, [18F]FDG and [64Cu]Cu-DOTATATE, and hence is a viable option offering the ability for delay correction across various organs and tracers in use with kinetic modeling.

7.
Diagnostics (Basel) ; 14(16)2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39202218

RESUMO

Stress is a ubiquitous challenge in modern societies. Symptoms range from mood swings and cognitive impairment to autonomic symptoms. This study explores the link between work-related stress and the neurobiological element of brain processing, testing the hypothesis that patients with occupational stress have altered cerebral glucose consumption compared to healthy controls. The participants' present conditions were evaluated using an adapted WHO SCAN interview. Neural activity at rest was assessed by positron emission tomography (PET) with the glucose analogue [18F]fluorodeoxyglucose. Participants were genotyped for the Val158Met polymorphism of the COMT gene, believed to influence stress resilience. This study included 11 women with work-related stress and 11 demographically comparable healthy controls aged 28-62 years, with an average of 46.2 years. The PET scans indicated clusters of decreased glucose consumption primarily located in the white matter of frontal lobe sub-gyral areas in stress patients. COMT Val158Met polymorphism detection indicated no immediate relation of the homozygous alleles and stress resilience; however, healthy controls mainly had the heterozygous allele. In conclusion, the results support that work-related stress does affect the brain in the form of altered glucose metabolism, suggesting neurobiological effects could be related to white matter abnormalities rather than gray matter deterioration. Genotyping indicates a more complex picture than just that of the one type being more resilient to stress. Further studies recruiting a larger number of participants are needed to confirm our preliminary findings.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39308430

RESUMO

Cross-sectional imaging supplements endoscopy in detecting disease manifestations in inflammatory bowel diseases (IBD). This study aimed to evaluate the accuracy of PET/MRI in a paediatric population suspected of IBD. This prospective study consecutively included patients aged 8-17 years under diagnostic evaluation for IBD. Forty-three patients underwent a PET/MRI scan and subsequent ileocolonoscopy, of whom 26 patients diagnosed with IBD participated in a follow-up scan, hereof 19 with Crohn's disease (CD), five with Ulcerative colitis and two with unclassified IBD. The results of PET alone, MRI alone, and PET/MRI combined were compared to a reference standard of endoscopy and histopathology. Of the 208 intestinal segments analysed, 109 showed inflammation, and 99 had no inflammation. In the per-segment analysis PET had a sensitivity of 0.83 (95% CI 0.73-0.93), specificity of 0.59 (95% CI 0.47-0.71), and area under the receiver operating characteristic curve (AUROC) of 0.73 (95% CI 0.67-0.80). MRI had a sensitivity of 0.52 (95% CI 0.41-0.64), specificity 0.89 (95% CI 0.82-0.96), and AUROC of 0.72 (95% CI 0.66-0.77). PET/MRI had a sensitivity of 0.83 (95% CI 0.74-0.94), specificity of 0.57 (95% CI 0.44-0.69), and AUROC of 0.77 (95% CI 0.71-0.84). At follow-up, PET and MRI scores decreased, and the change in MRI was able to identify patients with a clinical response. The accuracy of the PET/MRI scan in detecting inflammation in the terminal ileum and colon was moderate and not superior to either modality alone. With technological advances and combined reading, PET/MRI may still be valuable in selected cases.

9.
Diagnostics (Basel) ; 14(18)2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39335734

RESUMO

Background: The outstanding capabilities of modern Positron Emission Tomography (PET) to highlight small tumor lesions and provide pathological function assessment are at peril from image quality degradation caused by respiratory and cardiac motion. However, the advent of the long axial field-of-view (LAFOV) scanners with increased sensitivity, alongside the precise time-of-flight (TOF) of modern PET systems, enables the acquisition of ultrafast time resolution images, which can be used for estimating and correcting the cyclic motion. Methods: 0.25 s so-called [18F]FDG PET histo image series were generated in the scope of for detecting respiratory and cardiac frequency estimates applicable for performing device-less data-driven gated image reconstructions. The frequencies of the cardiac and respiratory motion were estimated for 18 patients using Short Time Fourier Transform (STFT) with 20 s and 30 s window segments, respectively. Results: The Fourier analysis provided time points usable as input to the gated reconstruction based on eight equally spaced time gates. The cardiac investigations showed estimates in accordance with the measured pulse oximeter references (p = 0.97) and a mean absolute difference of 0.4 ± 0.3 beats per minute (bpm). The respiratory frequencies were within the expected range of 10-20 respirations per minute (rpm) in 16 out of 18 patients. Using this setup, the analysis of three patients with visible lung tumors showed an increase in tumor SUVmax and a decrease in tumor volume compared to the non-gated reconstructed image. Conclusions: The method can provide signals that were applicable for gated reconstruction of both cardiac and respiratory motion, providing a potential increased diagnostic accuracy.

10.
Diagnostics (Basel) ; 14(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38893602

RESUMO

Incorrect scatter scaling of positron emission tomography (PET) images can lead to halo artifacts, quantitative bias, or reconstruction failure. Tail-fitted scatter scaling (TFSS) possesses performance limitations in multiple cases. This study aims to investigate a novel method for scatter scaling: maximum-likelihood scatter scaling (MLSS) in scenarios where TFSS tends to induce artifacts or are observed to cause reconstruction abortion. [68Ga]Ga-RGD PET scans of nine patients were included in cohort 1 in the scope of investigating the reduction of halo artifacts relative to the scatter estimation method. PET scans of 30 patients administrated with [68Ga]Ga-uPAR were included in cohort 2, used for an evaluation of the robustness of MLSS in cases where TFSS-integrated reconstructions are observed to fail. A visual inspection of MLSS-corrected images scored higher than TFSS-corrected reconstructions of cohort 1. The quantitative investigation near the bladder showed a relative difference in tracer uptake of up to 94.7%. A reconstruction of scans included in cohort 2 resulted in failure in 23 cases when TFSS was used. The lesion uptake values of cohort 2 showed no significant difference. MLSS is suggested as an alternative scatter-scaling method relative to TFSS with the aim of reducing halo artifacts and a robust reconstruction process.

11.
Diagnostics (Basel) ; 13(19)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37835864

RESUMO

Neuroimaging holds an essential position in global healthcare, as brain-related disorders are a substantial and growing burden. Non-degenerative disorders such as stress, depression and anxiety share common function related traits of diffuse and fluctuating changes, such as change in brain-based functions of mood, behavior and cognitive abilities, where underlying physiological mechanism remain unresolved. In this study we developed a novel application for studying intra-subject task-activated brain function by the quantitative physiological measurement of the change in glucose metabolism in a single scan setup. Data were acquired on a PET/MR-scanner. We implemented a functional [18F]-FDG PET-scan with double boli-tracer administration and finger-tapping activation, as proof-of-concept, in five healthy participants. The [18F]-FDG data were analyzed using a two-tissue compartment double boli kinetic model with an image-derived input function. For stand-alone visual reference, blood oxygenation level dependent (BOLD) functional MRI (fMRI) was acquired in the same session and analyzed separately. We were able to measure the cerebral glucose metabolic rate during baseline as well as activation. Results showed increased glucose metabolic rate during activation by 36.3-87.9% mean 62.0%, locally in the peak seed region of M1 in the brain, on an intra-subject level, as well as very good spatial accuracy on group level, and localization compared to the BOLD fMRI result at subject and group level. Our novel method successfully determined the relative increase in the cerebral metabolic rate of glucose on a voxel level with good visual association to fMRI at the subject-level, holding promise for future individual clinical application. This approach will be easily adapted in future clinical perspectives and pharmacological interventions studies.

12.
Front Neurosci ; 17: 1142383, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37090806

RESUMO

Purpose: Conventional magnetic resonance imaging (MRI) can for glioma assessment be supplemented by positron emission tomography (PET) imaging with radiolabeled amino acids such as O-(2-[18F]fluoroethyl)-L-tyrosine ([18F]FET), which provides additional information on metabolic properties. In neuro-oncology, patients often undergo brain and skull altering treatment, which is known to challenge MRI-based attenuation correction (MR-AC) methods and thereby impact the simplified semi-quantitative measures such as tumor-to-brain ratio (TBR) used in clinical routine. The aim of the present study was to examine the applicability of our deep learning method, DeepDixon, for MR-AC in [18F]FET PET/MRI scans of a post-surgery glioma cohort with metal implants. Methods: The MR-AC maps were assessed for all 194 included post-surgery glioma patients (318 studies). The subgroup of 147 patients (222 studies, 200 MBq [18F]FET PET/MRI) with tracer uptake above 1 ml were subsequently reconstructed with DeepDixon, vendor-default atlas-based method, and a low-dose computed tomography (CT) used as reference. The biological tumor volume (BTV) was delineated on each patient by isocontouring tracer uptake above a TBR threshold of 1.6. We evaluated the MR-AC methods using the recommended clinical metrics BTV and mean and maximum TBR on a patient-by-patient basis against the reference with CT-AC. Results: Ninety-seven percent of the studies (310/318) did not have any major artifacts using DeepDixon, which resulted in a Dice coefficient of 0.89/0.83 for tissue/bone, respectively, compared to 0.84/0.57 when using atlas. The average difference between DeepDixon and CT-AC was within 0.2% across all clinical metrics, and no statistically significant difference was found. When using DeepDixon, only 3 out of 222 studies (1%) exceeded our acceptance criteria compared to 72 of the 222 studies (32%) with the atlas method. Conclusion: We evaluated the performance of a state-of-the-art MR-AC method on the largest post-surgical glioma patient cohort to date. We found that DeepDixon could overcome most of the issues arising from irregular anatomy and metal artifacts present in the cohort resulting in clinical metrics within acceptable limits of the reference CT-AC in almost all cases. This is a significant improvement over the vendor-provided atlas method and of particular importance in response assessment.

13.
J Imaging ; 9(3)2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36976116

RESUMO

We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F]FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p < 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p < 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p < 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p < 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.

14.
EJNMMI Phys ; 9(1): 55, 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-35978211

RESUMO

BACKGROUND: Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. MATERIALS AND METHODS: Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. RESULTS: Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. CONCLUSIONS: Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.

15.
Sci Rep ; 12(1): 1977, 2022 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-35132097

RESUMO

Patients with brain metastases, the most common intracranial tumor, have an average survival ranging from a few months to 40 months, and new treatment initiatives are needed. Cryoablation is a minimally invasive, well-tolerated, and effective procedure commonly applied for treatment of renal tumors and certain other malignancies. We aimed to examine the clinical usefulness of this procedure in a step-by-step program starting with cerebral cryoablation in healthy pigs. In four terminal and four non-terminal non-tumor bearing pigs, we studied immediate and delayed effects of cerebral cryoablation. Safety was assessed by computed tomography (CT), and clinical observation of behavior, neurological deficits, and wellbeing. Effects were assessed by histological and immuno-histochemical analyses addressing structural and metabolic changes supported by additional magnetic resonance imaging (MRI) and positron emission tomography (PET) in the non-terminal animals. Using CT-guidance, cryoablation probes were successfully inserted without complications, and ice formation could be monitored real-time with CT. No animal developed neurological deficits or signs of discomfort. Histological and immunohistochemical analyses, MRI, and PET revealed profound structural and biological damage within the lesion. MRI and PET revealed no long-term damage to healthy tissue outside the cryoablation zone. Cerebral cryoablation appears to be a feasible, safe, and controllable procedure that can be monitored successfully with CT. The net effect is a dead brain lesion without damage of either nearby or remote healthy structures. Immediate changes are local hemorrhage and edema; delayed effects are perfusion defects, immune system activation, and astrogliosis.


Assuntos
Neoplasias Encefálicas/cirurgia , Encéfalo/patologia , Encéfalo/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Animais , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Estudos de Viabilidade , Imageamento por Ressonância Magnética , Neuroimagem , Segurança , Suínos , Tomografia Computadorizada por Raios X
16.
Diagnostics (Basel) ; 11(10)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34679505

RESUMO

Angiogenesis is crucial in tissue repair and prevents scar tissue formation following an ischemic event such as myocardial infarction. The ischemia induces formation of new capillaries, which have high expression of integrin αvß3. [68Ga]Ga-NODAGA-E[(cRGDyK)]2 ([68Ga]Ga-RGD) is a promising PET-radiotracer reflecting angiogenesis by binding to integrin αvß3. A Göttingen mini-pig underwent transient catheter-induced left anterior descending artery (LAD) occlusion for 120 min, and after 8 weeks was imaged on a Siemens mMR 3T PET/MR system. A large antero-septal infarction was evident by late gadolinium enhancement (LGE) on the short axis and 2-4 chamber views. The infarcted area corresponded to the area with high [68Ga]Ga-RGD uptake on the fused PET/MR images, with no uptake in the healthy myocardium. To support the hypothesis that [68Ga]Ga-RGD uptake reflects angiogenesis, biopsies were sampled from the infarct border and healthy myocardium. Expression of αvß3 was evaluated using immunohistochemistry. The staining showed higher αvß3 expression in the capillaries of the infarct border compared to those in the healthy myocardium. These initial data confirm in vivo detection of angiogenesis using [68Ga]Ga-RGD PET in a translational model, which overall support the method applicability when evaluating novel cardio-protective therapies.

17.
Ugeskr Laeger ; 182(28)2020 07 06.
Artigo em Dinamarquês | MEDLINE | ID: mdl-32734879

RESUMO

The diagnosis of a malignant brain tumour is often associated with a poor prognosis. Current treatment is surgical resection followed by radio-chemotherapy. Surgical resection is most favourable in relation to survival time. Unfortunately, many patients are not suitable for surgical resection, due to inoperable tumour location or the patients' poor state. Minimally invasive thermal ablation may pose an interesting new treatment alternative. In this review, we describe the evolution, the underlying physiology and the clinical applications of cryo- and laser-induced thermal therapy of primary and secondary brain tumours.


Assuntos
Neoplasias Encefálicas , Ablação por Cateter , Neoplasias Encefálicas/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA