Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Comput Math Methods Med ; 2016: 6183679, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27051460

RESUMO

Stress shielding is a well-known failure factor in hip implants. This work proposes a design concept for hip implants, using a combination of metallic stem with a polymer coating (polyether ether ketone (PEEK)). The proposed design concept is simulated using titanium alloy stems and PEEK coatings with thicknesses varying from 100 to 400 µm. The Finite Element analysis of the cancellous bone surrounding the implant shows promising results. The effective von Mises stress increases between 81 and 92% for the complete volume of cancellous bone. When focusing on the proximal zone of the implant, the increased stress transmission to the cancellous bone reaches between 47 and 60%. This increment in load transferred to the bone can influence mineral bone loss due to stress shielding, minimizing such effect, and thus prolonging implant lifespan.


Assuntos
Materiais Revestidos Biocompatíveis/química , Prótese de Quadril , Cetonas/química , Polietilenoglicóis/química , Desenho de Prótese , Titânio/química , Ligas , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Benzofenonas , Durapatita/química , Fêmur/patologia , Análise de Elementos Finitos , Humanos , Modelos Teóricos , Osseointegração , Polímeros , Pressão , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA