Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Aust Crit Care ; 36(5): 769-781, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36404269

RESUMO

BACKGROUND: Recent evidence highlights the need for an interdisciplinary approach to antimicrobial stewardship (AMS). Nursing involvement in optimising antimicrobials in the intensive care unit (ICU) remains understudied. OBJECTIVE: The objective of this study was to explore nurses' perceptions and experiences of antimicrobial optimisation or stewardship in ICUs in Australia. METHODS: An anonymous web-based survey was deployed nationally in early 2021 through two ICU nursing networks. Associations between survey responses were analysed descriptively and by using nonparametric tests (with statistical significance established at p ≤ 0.05). Free-text survey responses underwent qualitative thematic analysis. Interpretation and reporting of quantitative and qualitative data were integrated. RESULTS: A total of 226 ICU nurses completed the survey. The majority (197/226; 87%) responded that lack of education limits engagement in AMS. Only 13% (30/226) reported the presence of AMS education and training for nurses in their ICUs. Only about half (108/226; 48%) of the nurses were confident to question prescribers when they considered that the antimicrobial prescribed was unnecessary, with nurses in senior roles more likely to do so than nurses providing bedside care (p < 0.05). Gaps in education (including unfamiliarity with AMS roles), noninclusive antimicrobial discussions, moral distress, and potential workload burden were seen as potential barriers/challenges to engagement. CONCLUSION: The multifactorial barriers identified that inhibit nurses from performing AMS tasks could be addressed by strengthening interprofessional education at all levels and by applying practical AMS interventions that are inclusive for nursing participation. A purposeful culture change that fosters psychological safety and collaborative practice is paramount to supporting nurses in these roles.


Assuntos
Anti-Infecciosos , Enfermagem de Cuidados Críticos , Humanos , Inquéritos e Questionários , Austrália , Unidades de Terapia Intensiva
2.
Blood Purif ; 51(12): 997-1005, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35443247

RESUMO

INTRODUCTION: Continuous renal replacement therapy using regional citrate anticoagulation is commonly used as a modality of organ support in the critically ill population. Currently, citrate accumulation or toxicity is assessed using surrogate markers, notably the uncorrected total-to-ionized calcium ration. The accuracy and utility of this method have been questioned. OBJECTIVES/AIMS: The aim of this study was to compare the surrogate markers used for assessing citrate accumulation or toxicity using the measurement of plasma citrate as the gold standard. METHODS: Blood was sampled from 20 patients before, during, and after episodes of filtration with citrate concentration measured using spectrophotometry. Demographic and other clinical and biochemical data were also collected. According to protocol, a 15 mmol/L solution of trisodium citrate was used as the prefilter anticoagulant. Results were analyzed using STATA (v16.0) and presented as mean (SD), median (IQR), or simple proportion. Univariate linear regression using citrate concentration as the dependent variable was performed with all surrogate markers. RESULTS: Twenty patients (17 males) were enrolled in the study with a mean (SD) age of 62.7 (9.9) years. The uncorrected calcium ratio had the best fit to the citrate data with an R2 value of 0.39. The albumin-corrected calcium ratio, pH, anion gap (AG), albumin-corrected AG, standard base excess, and strong ion gap all had R2 values less than 0.05. CONCLUSION(S): In the absence of direct measurement of citrate concentration, uncorrected total-to-ionized calcium ratio is superior to other surrogate markers, though not ideal, in assessing citrate accumulation or toxicity.


Assuntos
Ácido Cítrico , Terapia de Substituição Renal Contínua , Humanos , Masculino , Pessoa de Meia-Idade , Albuminas , Anticoagulantes/efeitos adversos , Biomarcadores , Cálcio , Citratos/efeitos adversos , Ácido Cítrico/uso terapêutico , Terapia de Substituição Renal , Feminino , Idoso
3.
J Cardiothorac Vasc Anesth ; 36(12): 4313-4319, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36207199

RESUMO

OBJECTIVE: To determine the effect of intensive care unit (ICU) length of stay (LOS) on hospital mortality and non-home discharge for patients undergoing cardiac surgery over a 16-year period in Australia and New Zealand. DESIGN: A retrospective, multicenter cohort study covering the period January 1, 2004 to December 31, 2019. SETTING: One hundred one hospitals in Australia and New Zealand that submitted data to the Australia New Zealand Intensive Care Society Adult Patient Database. PARTICIPANTS: Adult patients (aged >18) who underwent coronary artery bypass grafting, valve surgery, or combined valve + coronary artery surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The authors analyzed 252,948 cardiac surgical patients from 101 hospitals, with a median age of 68.3 years (IQR 60-75.5), of whom 74.2% (187,632 of 252,948) were male patients. A U-shaped relationship was observed between ICU LOS and hospital mortality, with significantly elevated mortality at short (<20 hours) and long (>5 days) ICU LOS, which persisted after adjustment for illness severity and across clinically important subgroups (odds ratio for mortality with ICU LOS >5 days = 3.21, 95% CI 2.88-3.58, p < 0.001). CONCLUSIONS: Prolonged duration of ICU LOS after cardiac surgery is associated with increased hospital mortality in a U-shaped relationship. An ICU LOS >5 days should be considered a meaningful definition for prolonged ICU stay after cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Unidades de Terapia Intensiva , Tempo de Internação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Cardíacos/mortalidade , Mortalidade Hospitalar , Tempo de Internação/estatística & dados numéricos , Nova Zelândia/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento , Austrália/epidemiologia
4.
Aust Crit Care ; 35(2): 181-185, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34120804

RESUMO

BACKGROUND: Nasogastric tube insertion in the intensive care setting is common. Placement verification is required to avoid complications of bronchotracheal misplacement that range from aspiration of infused contents to death from associated causes. The gold standard of practice is chest radiography. Ultrasound is a growing modality and is readily available in most intensive care units. OBJECTIVE: The objective of this study was to examine the diagnostic accuracy of ultrasound imaging of nasogastric tube placements by nonradiologists compared with chest radiography in mechanically ventilated patients. METHODS: This is a dual-centre prospective, single-blind study. Correct placement was captured with a hyperechoic ultrasound image of a nasogastric tube in the oesophagus and epigastrium, which was compared with chest radiography. Patient enrolment included general adult intensive care unit admissions who were mechanically ventilated and required a nasogastric tube for either the treatment or monitoring of their illness. RESULTS: A total of 25 patients were enrolled (15 men, 10 women), and their mean age was 68.1 ± 13.8 years. Outcome measures were the percentage of correctly identified nasogastric tubes in the oesophagus and epigastrium. The sensitivity of oesophagus ultrasound was 88%, and the positive predictive value was 100%. The subxiphoid sensitivity was 64%, and the positive predictive value was 100%. Comparison sensitivity and specificity of oesophagus versus subxiphoid ultrasound was 64% and 33%, respectively. There was a positive predictive value of 88% and a negative predictive value of 11%. The results showed a variance in detection sensitivity in the ultrasound scans of the oesophagus (0.88) and subxiphoid (0.64) (N = 25, p = 0.012). CONCLUSION: Nasogastric tube placement verification via ultrasound in critically ill mechanically ventilated patients conducted by nonradiologists with minimal training is associated with diagnostic accuracy. These results add to the limited evidence in the current literature; however, they should be considered with awareness that placement in the stomach in this study was detected in 64% of cases, alongside the missed captured evidence of the sonographer's ability to identify misplacement.


Assuntos
Respiração Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Método Simples-Cego , Ultrassonografia/métodos
5.
Aust Crit Care ; 35(4): 415-423, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34404579

RESUMO

BACKGROUND: Clinical guidelines on infection control strategies in healthcare workers (HCWs) play an important role in protecting them during the severe acute respiratory syndrome coronavirus 2 pandemic. Poorly constructed guidelines that are incomprehensive and/or ambiguous may compromise HCWs' safety. OBJECTIVE: The objective of this study was to develop and validate a tool to appraise guidelines on infection control strategies in HCWs based on the guidelines published early in the coronavirus disease 2019 pandemic. DESIGN, SETTING, AND OUTCOMES: A three-stage, web-based, Delphi consensus-building process among a panel of diverse HCWs and healthcare managers was performed. The tool was validated by appraising 40 international, specialty-specific, and procedure-specific guidelines along with national guidelines from countries with a wide range of gross national income. RESULTS: Overall consensus (≥75%) was reached at the end of three rounds for all six domains included in the tool. The Delphi panel recommended an ideal infection control guideline should encompass six domains: general characteristics (domain 1), engineering recommendations (domain 2), personal protective equipment (PPE) use (domain 3), and administrative aspects (domain 4-6) of infection control. The appraisal tool performed well across the six domains, and the inter-rater agreement was excellent for the 40 guidelines. All included guidelines performed relatively better in domains 1-3 than in domains 4-6, and this was more evident in guidelines originating from lower income countries. CONCLUSION: The guideline appraisal tool was robust and easy to use. Engineering recommendations aspects of infection control, administrative measures that promote optimal PPE use, and HCW wellbeing were generally lacking in assessed guidelines. This tool may enable health systems to adopt high-quality HCW infection control guidelines during the severe acute respiratory syndrome coronavirus 2 pandemic and may also provide a framework for future guideline development.


Assuntos
COVID-19 , Pessoal de Saúde , Humanos , Controle de Infecções , Transmissão de Doença Infecciosa do Paciente para o Profissional , Pandemias/prevenção & controle , SARS-CoV-2
6.
Blood Purif ; 50(6): 848-856, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33550280

RESUMO

BACKGROUND: Continuous renal replacement therapy (CRRT) with regional citrate anticoagulation (RCA) is now commonly used to treat acute kidney injury in critically ill patients. The concentration of citrate is not routinely measured, with citrate accumulation and/or toxicity primarily assessed using surrogate measures. OBJECTIVES: The aim of this study was to measure the concentration of citrate in plasma and ultrafiltrate in patients receiving CRRT with RCA using a modified commercial enzymatic assay. METHODS: After meeting inclusion criteria, blood was sampled from 20 patients before, during, and after episodes of filtration. Using spectrophotometry, samples were tested for citrate concentration. Demographic and other clinical and biochemical data were also collected. Throughout, a 15 mmol/L solution of trisodium citrate was used as the prefilter anticoagulant. Results were analysed using STATA (v15.0) and presented as mean (SD), median (IQR), or simple proportion. Comparisons were made using either the Student t test or the Wilcoxon rank-sum test. Correlation was assessed using Pearson's r. RESULTS: Twenty patients (17 males) were enrolled in the study. Mean (SD) age was 63.7 years (9.9). Median (IQR) ICU length of stay was 281 h (199, 422) with 85% undergoing intermittent positive pressure ventilation. Median APACHE 3 score was 95 (87, 117) with an overall 30% mortality rate. Median filtration time was 85 h (46, 149). No difference was found between pre- and post-filtration plasma citrate concentrations (79 µmol/L [50] vs. 71 µmol/L [42], p = 0.65). Mean citrate concentration during filtration was 508 µmol/L (221) with a maximum of 1,070 µmol/L. This was significantly higher than the pre/post levels (p < 0.001). CONCLUSIONS: Plasma concentrations of citrate rose significantly during episodes of CRRT using RCA returning back to normal after cessation of treatment.


Assuntos
Anticoagulantes/sangue , Ácido Cítrico/sangue , Terapia de Substituição Renal Contínua/métodos , Idoso , Anticoagulantes/análise , Coagulação Sanguínea/efeitos dos fármacos , Ácido Cítrico/análise , Ensaios Enzimáticos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Respir Res ; 19(1): 231, 2018 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-30466423

RESUMO

BACKGROUND: Sepsis is a multi-system syndrome that remains the leading cause of mortality and critical illness worldwide, with hemodynamic support being one of the cornerstones of the acute management of sepsis. We used an ovine model of endotoxemic shock to determine if 0.9% saline resuscitation contributes to lung inflammation and injury in acute respiratory distress syndrome, which is a common complication of sepsis, and investigated the potential role of matrix metalloproteinases in this process. METHODS: Endotoxemic shock was induced in sheep by administration of an escalating dose of lipopolysaccharide, after which they subsequently received either no fluid bolus resuscitation or a 0.9% saline bolus. Lung tissue, bronchoalveolar fluid (BAL) and plasma were analysed by real-time PCR, ELISA, flow cytometry and immunohistochemical staining to assess inflammatory cells, cytokines, hyaluronan and matrix metalloproteinases. RESULTS: Endotoxemia was associated with decreased serum albumin and total protein levels, with activated neutrophils, while the glycocalyx glycosaminoglycan hyaluronan was significantly increased in BAL. Quantitative real-time PCR studies showed higher expression of IL-6 and IL-8 with saline resuscitation but no difference in matrix metalloproteinase expression. BAL and tissue homogenate levels of IL-6, IL-8 and IL-1ß were elevated. CONCLUSIONS: This data shows that the inflammatory response is enhanced when a host with endotoxemia is resuscitated with saline, with a comparatively higher release of inflammatory cytokines and endothelial/glycocalyx damage, but no change in matrix metalloproteinase levels.


Assuntos
Lesão Pulmonar Aguda/metabolismo , Endotoxemia/metabolismo , Mediadores da Inflamação/metabolismo , Ressuscitação/métodos , Choque/metabolismo , Lesão Pulmonar Aguda/induzido quimicamente , Animais , Líquido da Lavagem Broncoalveolar , Endotoxemia/induzido quimicamente , Endotoxemia/terapia , Inflamação/induzido quimicamente , Inflamação/metabolismo , Lipopolissacarídeos/toxicidade , Ovinos , Choque/induzido quimicamente , Choque/terapia
8.
J Clin Monit Comput ; 32(2): 227-234, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28281192

RESUMO

Cardiac output (CO) is commonly measured using the thermodilution technique at the time of right heart catheterisation (RHC). However inter-operator variability, and the operator characteristics which may influence that, has not been quantified. Therefore, this study aimed to assess inter-operator variability with the thermodilution technique using a mock circulation loop (MCL) with calibrated flow sensors. Participants were blinded and asked to determine 4 levels of CO using the thermodilution technique, which was compared with the MCL calibrated flow sensors. The MCL was used to randomly generate CO between 3.0 and 7.0 L/min through changes in heart rate, contractility and vascular resistance with a RHC inserted through the MCL pulmonary artery. Participant characteristics including gender, specialty, age, height, weight, body-mass index, grip strength and RHC experience were recorded and compared to determine their relationship with CO measurement accuracy. In total, there were 15 participants, made up of consultant cardiologists (6), advanced trainees in cardiology (5) and intensive care consultants (4). The majority (9) had performed 26-100 previous RHCs, while 4 had performed more than 100 RHCs. Compared to the MCL-measured CO, participants overestimated CO using the thermodilution technique with a mean difference of +0.75 ± 0.71 L/min. The overall r2 value for actual vs measured CO was 0.85. The difference between MCL and thermodilution derived CO declined significantly with increasing RHC experience (P < 0.001), increasing body mass index (P < 0.001) and decreasing grip strength (P = 0.033). This study demonstrated that the thermodilution technique is a reasonable method to determine CO, and that operator experience was the only participant characteristic related to CO measurement accuracy. Our results suggest that adequate exposure to, and training in, the thermodilution technique is required for clinicians who perform RHC.


Assuntos
Cateterismo Cardíaco/métodos , Débito Cardíaco , Variações Dependentes do Observador , Termodiluição/métodos , Adulto , Calibragem , Cateterismo de Swan-Ganz , Feminino , Força da Mão , Hemodinâmica , Humanos , Masculino , Modelos Cardiovasculares , Artéria Pulmonar/patologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
9.
J Clin Monit Comput ; 31(2): 449-457, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27072989

RESUMO

We aimed to evaluate the sensitivity and specificity of 8 biochemical scanning tools in signalling the presence of unmeasured anions. We used blood gas and biochemical data from 15 patients during and after cardio-pulmonary bypass. Sampling time-points were pre-bypass (T1), 2 min post equilibration with priming fluid containing acetate and gluconate anions (T2), late bypass (T3) and 4 h after surgery (T4). We calculated the anion gap (AG), albumin-corrected anion gap (AGc), whole blood base excess (BE) gap, plasma BE gap, standard BE gap and the strong ion gap (SIG), plus 2 new indices-the unmeasured ion index (UIX) and unmeasured plasma anions according to the interstitial, plasma and erythrocyte acid-base model (IPEua). Total measured plasma concentrations of acetate and gluconate [XA] were proxies for unmeasured plasma anions. [XA] values (mmol/L) were 1.41 (0.87) at T1, 11.73 (3.28) at T2, 4.80 (1.49) at T3 and 1.36 (0.73) at T4. Corresponding [albumin] values (g/L) were 32.3 (2.0), 19.8 (2.6), 21.3 (2.5) and 29.1 (2.3) respectively. Only the AG failed to increase significantly at T2 in response to a mean [XA] surge of >10 mEq/L. At an [XA] threshold of 6 mEq/L, areas under receiver -operator characteristic curves in rank order were IPEua and UIX (0.88 and 0.87 respectively), SIG (0.81), AGc (0.79), standard BE gap (0.77), plasma BE gap (0.71), BE gap (0.70) and AG (0.59). Similar ranking hierarchies applied to positive and negative predictive values. We conclude that during acute hemodilution UIX and IPEua are superior to the anion gap (with and without albumin correction) and 4 other indices as scanning tools for unmeasured anions.


Assuntos
Equilíbrio Ácido-Base , Desequilíbrio Ácido-Base/sangue , Gasometria/instrumentação , Gasometria/métodos , Íons/sangue , Acetatos/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Albuminas/análise , Área Sob a Curva , Bicarbonatos/administração & dosagem , Ponte Cardiopulmonar/métodos , Cloretos/administração & dosagem , Feminino , Gluconatos/sangue , Humanos , Concentração de Íons de Hidrogênio , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , NAD/sangue , NADP/sangue , Curva ROC , Sensibilidade e Especificidade , Sódio/administração & dosagem , Fatores de Tempo , Adulto Jovem
10.
Am J Physiol Lung Cell Mol Physiol ; 311(6): L1202-L1212, 2016 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-27815258

RESUMO

Extracorporeal membrane oxygenation (ECMO) is a life-saving treatment for patients with severe refractory cardiorespiratory failure. Exposure to the ECMO circuit is thought to trigger/exacerbate inflammation. Determining whether inflammation is the result of the patients' underlying pathologies or the ECMO circuit is difficult. To discern how different insults contribute to the inflammatory response, we developed an ovine model of lung injury and ECMO to investigate the impact of smoke-induced lung injury and ECMO in isolation and cumulatively on pulmonary and circulating inflammatory cells, cytokines, and tissue remodeling. Sheep receiving either smoke-induced acute lung injury (S-ALI) or sham injury were placed on veno-venous (VV) ECMO lasting either 2 or 24 h, with controls receiving conventional ventilation only. Lung tissue, bronchoalveolar fluid, and plasma were analyzed by RT-PCR, immunohistochemical staining, and zymography to assess inflammatory cells, cytokines, and matrix metalloproteinases. Pulmonary compliance decreased in sheep with S-ALI placed on ECMO with increased numbers of infiltrating neutrophils, monocytes, and alveolar macrophages compared with controls. Infiltration of neutrophils was also observed with S-ALI alone. RT-PCR studies showed higher expression of matrix metalloproteinases 2 and 9 in S-ALI plus ECMO, whereas IL-6 was elevated at 2 h. Zymography revealed higher levels of matrix metalloproteinase 2. Circulating plasma levels of IL-6 were elevated 1-2 h after commencement of ECMO alone. These data show that the inflammatory response is enhanced when a host with preexisting pulmonary injury is placed on ECMO, with increased infiltration of neutrophils and macrophages, the release of inflammatory cytokines, and upregulation of matrix metalloproteinases.


Assuntos
Lesão Pulmonar Aguda/complicações , Lesão Pulmonar Aguda/patologia , Oxigenação por Membrana Extracorpórea , Pneumonia/complicações , Pneumonia/patologia , Lesão Pulmonar Aguda/sangue , Lesão Pulmonar Aguda/enzimologia , Animais , Biomarcadores/metabolismo , Brônquios/patologia , Lavagem Broncoalveolar , Complacência (Medida de Distensibilidade) , Edema/complicações , Edema/patologia , Células Epiteliais/enzimologia , Células Epiteliais/metabolismo , Células Epiteliais/patologia , Imuno-Histoquímica , Interleucina-1beta/sangue , Interleucina-6/sangue , Interleucina-8/sangue , Contagem de Leucócitos , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Tamanho do Órgão , Pneumonia/sangue , Pneumonia/enzimologia , Fibrose Pulmonar/sangue , Fibrose Pulmonar/complicações , Fibrose Pulmonar/metabolismo , Fibrose Pulmonar/patologia , Ovinos , Fumar/efeitos adversos
11.
Thorax ; 71(8): 759-61, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27015801

RESUMO

UNLABELLED: Patients with COPD using long-term oxygen therapy (LTOT) over 15 h per day have improved outcomes. As inhalation of dry cold gas is detrimental to mucociliary clearance, humidified nasal high flow (NHF) oxygen may reduce frequency of exacerbations, while improving lung function and quality of life in this cohort. In this randomised crossover study, we assessed short-term physiological responses to NHF therapy in 30 males chronically treated with LTOT. LTOT (2-4 L/min) through nasal cannula was compared with NHF at 30 L/min from an AIRVO through an Optiflow nasal interface with entrained supplemental oxygen. Comparing NHF with LTOT: transcutaneous carbon dioxide (TcCO2) (43.3 vs 46.7 mm Hg, p<0.001), transcutaneous oxygen (TcO2) (97.1 vs 101.2 mm Hg, p=0.01), I:E ratio (0.75 vs 0.86, p=0.02) and respiratory rate (RR) (15.4 vs 19.2 bpm, p<0.001) were lower; and tidal volume (Vt) (0.50 vs 0.40, p=0.003) and end-expiratory lung volume (EELV) (174% vs 113%, p<0.001) were higher. EELV is expressed as relative change from baseline (%Δ). Subjective dyspnoea and interface comfort favoured LTOT. NHF decreased TcCO2, I:E ratio and RR, with a concurrent increase in EELV and Vt compared with LTOT. This demonstrates a potential mechanistic rationale behind the improved outcomes observed in long-term treatment with NHF in oxygen-dependent patients. TRIAL REGISTRATION NUMBER: ACTRN12613000028707.


Assuntos
Oxigenoterapia , Doença Pulmonar Obstrutiva Crônica/terapia , Taxa Respiratória , Volume de Ventilação Pulmonar , Dióxido de Carbono/análise , Estudos de Coortes , Estudos Cross-Over , Humanos , Assistência de Longa Duração , Masculino , Oximetria , Oxigenoterapia/métodos , Pico do Fluxo Expiratório , Respiração com Pressão Positiva/métodos , Qualidade de Vida
12.
Crit Care ; 20: 91, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27038617

RESUMO

BACKGROUND: Patients who require positive pressure ventilation through a tracheostomy are unable to phonate due to the inflated tracheostomy cuff. Whilst a speaking valve (SV) can be used on a tracheostomy tube, its use in ventilated ICU patients has been inhibited by concerns regarding potential deleterious effects to recovering lungs. The objective of this study was to assess end expiratory lung impedance (EELI) and standard bedside respiratory parameters before, during and after SV use in tracheostomised patients weaning from mechanical ventilation. METHODS: A prospective observational study was conducted in a cardio-thoracic adult ICU. 20 consecutive tracheostomised patients weaning from mechanical ventilation and using a SV were recruited. Electrical Impedance Tomography (EIT) was used to monitor patients' EELI. Changes in lung impedance and standard bedside respiratory data were analysed pre, during and post SV use. RESULTS: Use of in-line SVs resulted in significant increase of EELI. This effect grew and was maintained for at least 15 minutes after removal of the SV (p < 0.001). EtCO2 showed a significant drop during SV use (p = 0.01) whilst SpO2 remained unchanged. Respiratory rate (RR (breaths per minute)) decreased whilst the SV was in situ (p <0.001), and heart rate (HR (beats per minute)) was unchanged. All results were similar regardless of the patients' respiratory requirements at time of recruitment. CONCLUSIONS: In this cohort of critically ill ventilated patients, SVs did not cause derecruitment of the lungs when used in the ventilator weaning period. Deflating the tracheostomy cuff and restoring the airflow via the upper airway with a one-way valve may facilitate lung recruitment during and after SV use, as indicated by increased EELI. TRIAL REGISTRATION: Anna-Liisa Sutt, Australian New Zealand Clinical Trials Registry (ANZCTR). ACTRN: ACTRN12615000589583. 4/6/2015.


Assuntos
Respiração Artificial/métodos , Fala/fisiologia , Traqueostomia/métodos , Desmame do Respirador/métodos , Adulto , Idoso , Estudos de Coortes , Comunicação , Feminino , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Respiração Artificial/efeitos adversos , Respiração Artificial/estatística & dados numéricos , Traqueostomia/efeitos adversos , Traqueostomia/estatística & dados numéricos , Desmame do Respirador/efeitos adversos
13.
Blood Purif ; 42(3): 194-201, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27352175

RESUMO

BACKGROUND/AIMS: The study aimed to compare the changes in biochemistry occurring in patients undergoing continuous renal replacement therapy (CRRT) using 2 trisodium citrate solutions, Baxter hemofiltration fluid containing 18 mmol/l (C18) and Baxter NamSol, a custom manufactured solution containing 15 mmol/l (C15), both delivered as regional citrate anticoagulation (RCA) predilution fluids for hemofiltration. METHODS: This is a prospective randomized control trial conducted in a major regional adult intensive care unit. Patients were randomized to 1 of 2 RCA fluids. Progress was monitored using a standard daily panel of acid-base and biochemical tests. RESULTS: Forty-eight patients, 23 C18 and 25 C15, were recruited. In both groups, acidosis resolved within 36 h of institution of CRRT. By day 3, there were significant differences in serum [Na+], standard base excess and serum bicarbonate concentration, all being higher in the C18 group (p < 0.01). By day 5, the PaCO2 had also risen in the C18 group (p = 0.03). CONCLUSIONS: The C15 solution provided equivalent filter life to the C18 solution but without significant hypernatremia and metabolic alkalosis.


Assuntos
Anticoagulantes , Ácido Cítrico , Injúria Renal Aguda/induzido quimicamente , Citratos , Hemofiltração , Humanos , Estudos Prospectivos , Terapia de Substituição Renal
14.
J Clin Monit Comput ; 30(1): 69-75, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25749977

RESUMO

Non-invasive cardiac output monitoring techniques provide high yield, low risk mechanisms to identify and individually treat shock in the emergency setting. The non-invasive ultrasonic cardiac output monitoring (USCOM) device uses an ultrasound probe applied externally to the chest; however limitations exist with previous validation strategies. This study presents the in vitro validation of the USCOM device against calibrated flow sensors and compares user variability in simulated healthy and septic conditions. A validated mock circulation loop was used to simulate each condition with a range of cardiac outputs (2-10 l/min) and heart rates (50-95 bpm). Three users with varying degrees of experience using the USCOM device measured cardiac output and heart rate by placing the ultrasound probe on the mock aorta. Users were blinded to the condition, heart rate and cardiac output which were randomly generated. Results were reported as linear regression slope (ß). All users estimated heart rate in both conditions with reasonable accuracy (ß = 0.86-1.01), while cardiac output in the sepsis condition was estimated with great precision (ß = 1.03-1.04). Users generally overestimated the cardiac output in the healthy simulation (ß = 1.07-1.26) and reported greater difficulty estimating reduced cardiac output compared with higher values. Although there was some variability between users, particularly in the healthy condition (P < 0.01), all estimations were within a clinically acceptable range. In this study the USCOM provided a suitable measurement of cardiac output and heart rate when compared with our in vitro system. It is a promising technique to assist with the identification and treatment of shock.


Assuntos
Débito Cardíaco , Ecocardiografia Doppler/instrumentação , Serviços Médicos de Emergência/métodos , Testes de Função Cardíaca/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Testes de Função Cardíaca/métodos , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Crit Care ; 19: 164, 2015 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-25888449

RESUMO

INTRODUCTION: Vital drugs may be degraded or sequestered in extracorporeal membrane oxygenation (ECMO) circuits, with lipophilic drugs considered to be particularly vulnerable. However, the circuit effects on protein-bound drugs have not been fully elucidated. The aim of this experimental study was to investigate the influence of plasma protein binding on drug disposition in ex vivo ECMO circuits. METHODS: Four identical ECMO circuits comprising centrifugal pumps and polymethylpentene oxygenators and were used. The circuits were primed with crystalloid, albumin and fresh human whole blood and maintained at a physiological pH and temperature for 24 hours. After baseline sampling, known quantities of study drugs (ceftriaxone, ciprofloxacin, linezolid, fluconazole, caspofungin and thiopentone) were injected into the circuit to achieve therapeutic concentrations. Equivalent doses of these drugs were also injected into four polypropylene jars containing fresh human whole blood for drug stability testing. Serial blood samples were collected from the controls and the ECMO circuits over 24 hours, and the concentrations of the study drugs were quantified using validated chromatographic assays. A regression model was constructed to examine the relationship between circuit drug recovery as the dependent variable and protein binding and partition coefficient (a measure of lipophilicity) as explanatory variables. RESULTS: Four hundred eighty samples were analysed. There was no significant loss of any study drugs in the controls over 24 hours. The average drug recoveries from the ECMO circuits at 24 hours were as follows: ciprofloxacin 96%, linezolid 91%, fluconazole 91%, ceftriaxone 80%, caspofungin 56% and thiopentone 12%. There was a significant reduction of ceftriaxone (P = 0.01), caspofungin (P = 0.01) and thiopentone (P = 0.008) concentrations in the ECMO circuit at 24 hours. Both protein binding and partition coefficient were highly significant, with the model possessing a high coefficient of determination (R (2) = 0.88, P <0.001). CONCLUSIONS: Recovery of the highly protein-bound drugs ceftriaxone, caspofungin and thiopentone was significantly lower in the ECMO circuits at 24 hours. For drugs with similar lipophilicity, the extent of protein binding may determine circuit drug loss. Future clinical population pharmacokinetic studies should initially be focused on drugs with greater lipophilicity and protein binding, and therapeutic drug monitoring should be strongly considered with the use of such drugs.


Assuntos
Oxigenação por Membrana Extracorpórea/efeitos adversos , Caspofungina , Ceftriaxona/efeitos adversos , Ceftriaxona/farmacocinética , Equinocandinas/efeitos adversos , Equinocandinas/farmacocinética , Oxigenação por Membrana Extracorpórea/mortalidade , Fluconazol/efeitos adversos , Fluconazol/farmacocinética , Humanos , Lipopeptídeos , Modelos Teóricos , Plasma/química , Tiopental/efeitos adversos , Tiopental/farmacocinética
16.
Aust N Z J Obstet Gynaecol ; 54(4): 348-53, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24597944

RESUMO

BACKGROUND: Hypoxic ischaemic encephalopathy (HIE) is secondary to intrapartum asphyxia and the fifth largest cause of death of children under five. Incorrect use and interpretation of intrapartum cardiotocographs has been identified as a contributing factor to the development of HIE. Therefore, RANZCOG introduced the Fetal Surveillance Education Program (FSEP) to improve education and practice of intrapartum care. AIM: To investigate the incidence of HIE throughout Queensland between 2003 and 2011 during the introduction and implementation of RANZCOG FSEP. METHODS: The incidence of HIE admissions at each hospital in Queensland (2003-2011) was collated from Queensland Health Statistics Centre. RANZCOG FSEP provided data regarding course attendees throughout Queensland (2006-2011). Hospitals were grouped into four regions. Statistical analysis was conducted using Stata(TM) (version 12.0) - data appeared to follow a damped harmonic model. RESULTS: The posteducation (2006-2011) HIE rate was significantly lower (P = 0.02) than the pre-education (2003-2005) rate. The final model predicted a stabilisation of HIE occurrence rate at approximately 160 events/100,000 live births by 2012. This rate was stable if the level of education was maintained but rose back to the initial rate of 250 events/100,000 live births if the education participation was discontinued. CONCLUSIONS: This study identified a significant reduction in the incidence of HIE--a potentially life-threatening newborn condition--between 2003 and 2011, during and following FSEP implementation. Notwithstanding the inevitable limitations of state-based data collection, these results are encouraging. For such improvements to be sustained, education must reach all staff engaged in intrapartum care and be regularly repeated.


Assuntos
Cardiotocografia , Educação Médica Continuada , Hipóxia-Isquemia Encefálica/epidemiologia , Obstetrícia/educação , Humanos , Hipóxia-Isquemia Encefálica/prevenção & controle , Incidência , Recém-Nascido , Assistência Perinatal , Período Periparto , Guias de Prática Clínica como Assunto , Queensland/epidemiologia
17.
Nephrology (Carlton) ; 18(10): 665-70, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23841726

RESUMO

AIM: Most clinical registries in Australia, including the Australia and New Zealand Dialysis and Transplant Registry (ANZDATA), do not audit submitted data. Inaccurate data can bias registry analysis. This study aimed to audit data submitted to ANZDATA from a single region. METHODS: A retrospective audit of individual haemodialysis patient data recorded by ANZDATA at 31 December 2009 was completed by nephrologists in a blinded fashion. Original data were recorded by nursing staff. Patients received treatment at a public hospital, two affiliated satellite haemodialysis units, and three private haemodialysis units. RESULTS: Fifty-one audits were completed of a total 175 patients (29.1%) undertaking haemodialysis in 2009. Primary renal disease was correct in 86.3% (95%CI: 74.3-93.2), although errors in type of glomerulonephritis were common. Date of first dialysis (± 1-month error margin) was correct for 93.6%. Creatinine at first dialysis (± 10% error margin) was correct in 74.4%. Baseline comorbidity accuracy included: peripheral vascular disease (sensitivity 36.4% (95%CI: 24.6-50.1), specificity 82.8% (95%CI: 70.2-90.7)), ischaemic heart disease (sensitivity 69.2% (95%CI: 55.6-80.2), specificity 88.0% (95%CI: 76.3-94.3)), chronic lung disease (sensitivity 25.0% (95%CI: 15.2-38.3), specificity 93.6% (95%CI: 83.4-97.7)), diabetes (sensitivity 86.4% (95%CI: 74.4-93.2), specificity 96.6% (95%CI: 87.5-99.1)), cerebrovascular disease (sensitivity 75.0% (95%CI: 61.7-84.8), specificity 95.3% (95%CI: 85.8-98.6)), and ever smoked (sensitivity 83.3% (95%CI: 70.3-91.4), specificity 71.4% (95%CI: 57.3-82.3)). Non-melanoma skin cancer was under-reported and inaccurate. CONCLUSION: Data accuracy was favourable compared with other renal registry validation studies. Data accuracy may be improved by education and training of collectors. A larger audit is necessary to validate ANZDATA.


Assuntos
Falência Renal Crônica/terapia , Transplante de Rim/normas , Sistema de Registros/normas , Diálise Renal/normas , Idoso , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Comorbidade , Feminino , Hospitais Públicos/normas , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/epidemiologia , Masculino , Auditoria Médica , Pessoa de Meia-Idade , Nova Zelândia/epidemiologia , Projetos Piloto , Prática Privada/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
J Clin Med ; 12(7)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37048711

RESUMO

The temporal trends in haematological parameters and their associations with blood product transfusion requirements in patients supported with extracorporeal membrane oxygenation (ECMO) are poorly understood. We performed a retrospective data analysis to better understand the behaviour of haematological and coagulation parameters and their associations with transfusion requirements during ECMO. METHODS: Patient demographics, haematological and coagulation parameters, plasma haemoglobin and fibrinogen concentrations, platelet count, the international normalised ratio (INR), the activated partial thromboplastin time (APTT), and blood product transfusion data from 138 patients who received ECMO in a single high-volume centre were analysed. RESULTS: Ninety-two patients received venoarterial (VA) ECMO and 46 patients received venovenous (VV) ECMO. The median (IQR) duration of VA, and VV ECMO was 8 (5-13) days and 13 (8-23) days, respectively. There were significant reductions in haemoglobin, the platelet count, and the fibrinogen concentration upon initiation of ECMO. On average, over time, patients on VV ECMO had platelet counts 44 × 109/L higher than those on VA ECMO (p ≤ 0.001). Fibrinogen and APTT did not vary significantly based on the mode of ECMO (p = 0.55 and p = 0.072, respectively). A platelet count < 50 × 109/L or a fibrinogen level < 1.8 g/L was associated with 50% chance of PRBC transfusion, regardless of the ECMO type, and packed red blood cell (PRBC) transfusion was more common with VA ECMO. APTT was predictive of the transfusion requirement, and the decrement in APTT was discriminatory between VVECMO survivors and nonsurvivors. CONCLUSION: ECMO support is associated with reductions in haemoglobin, platelet count, and fibrinogen. Patients supported with VA ECMO are more likely to receive a PRBC transfusion compared to those on VV ECMO. Thrombocytopaenia, hypofibrinogenaemia, and anticoagulation effect the likelihood of requiring PRBC transfusion. Further research is needed to define optimal blood management during ECMO, including appropriate transfusion triggers and the anticoagulation intensity.

19.
Am J Cardiol ; 207: 260-270, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37769569

RESUMO

Guidelines for transcatheter aortic valve replacement (TAVR) antithrombotic prophylaxis are extrapolated predominantly from percutaneous coronary intervention (PCI) data. Here, we examined temporal coagulation changes occurring in the early perioperative period to determine the pathobiologic validity of this supposition. This was a prospective observational study of consecutive patients who underwent transfemoral TAVR (n = 27), PCI (n = 12), or surgical aortic valve replacement (SAVR) requiring cardiopulmonary bypass and cross-clamping (n = 12). Blood samples were taken at 4 time points: T1 (baseline), after general anesthesia or sedation; T2, after heparin administration; T3, at the end of the procedure; and T4, 6 hours after the procedure. The samples were assessed concurrently using standard laboratory coagulation tests and viscoelastic tests of whole blood clotting, including the latest generation thromboelastometry (ROTEM sigma) and thromboelastometry (TEG 6s). Patients in the TAVR cohort were older and a had lower baseline hemoglobin level than patients in the PCI and SAVR cohorts. The baseline platelet function was similar between the TAVR and PCI cohorts and impaired in the SAVR cohort Figure S1. The baseline hemostatic measures were comparable among cohorts. Regarding the per-patient change from baseline, the TAVR cohort showed an overall more prothrombotic state than the other cohorts, with the most marked differences from the SAVR cohort after intraoperative heparin administration and from the PCI cohorts 6 hours after the procedure. In addition, the ROTEM and TEG parameters were well correlated but not interchangeable. In conclusion, patients who underwent TAVR have a more prothrombotic hemostatic profile than PCI and SAVR patients. These findings question the current guidelines that extrapolate antithrombotic regimens from PCI to TAVR settings.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Hemostáticos , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/métodos , Fibrinolíticos/uso terapêutico , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Heparina/uso terapêutico , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA