Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
AJR Am J Roentgenol ; 217(2): 336-346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936016

RESUMO

BACKGROUND. Transthoracic echocardiography (TTE) is the standard of care for initial evaluation of patients with suspected cardioembolic stroke. Although TTE is useful for assessing certain sources of cardiac emboli, its diagnostic capability is limited in the detection of other sources, including left atrial thrombus and aortic plaques. OBJECTIVE. The purpose of this article was to investigate sensitivity, specificity, and predictive value of cardiac CTA (CCTA), cardiac MRI (CMRI), and TTE for recurrence in patients with suspected cardioembolic stroke. METHODS. We retrospectively included 151 patients with suspected cardioembolic stroke who underwent TTE and either CMRI (n = 75) or CCTA (n = 76) between January 2013 and May 2017. We evaluated for the presence of left atrial thrombus, left ventricular thrombus, vulnerable aortic plaque, cardiac tumors, and valvular vegetation as causes of cardioembolic stroke. The end point was stroke recurrence. Sensitivity, specificity, PPV, and NPV for recurrent stroke were calculated; the diagnostic accuracy of CMRI, CCTA, and TTE was compared between and within groups using AUC. RESULTS. Twelve and 14 recurrent strokes occurred in the CCTA and CMRI groups, respectively. Sensitivity, specificity, PPV, and NPV were 33.3%, 93.7%, 50.0%, and 88.2% for CCTA; 14.3%, 80.3%, 14.3%, and 80.3% for CMRI; 14.3%, 83.6%, 16.7%, and 80.9% for TTE in the CMRI group; and 8.3%, 93.7%, 20.0%, and 84.5% for TTE in the CCTA group. Accuracy was not different (p > .05) between CCTA (AUC = 0.63; 95% CI, 0.49-0.77), CMRI (0.53; 95% CI, 0.42-0.63), TTE in the CMRI group (0.51; 95% CI, 0.40-0.61), and TTE in the CCTA group (0.51; 95% CI, 0.42-0.59). In the CCTA group, atrial and ventricular thrombus were detected by CCTA in three patients and TTE in one patient; in the CMRI group, thrombus was detected by CMRI in one patient and TTE in two patients. CONCLUSION. CCTA, CMRI, and TTE showed comparably high specificity and NPV for cardioembolic stroke recurrence. CCTA and CMRI may be valid alternatives to TTE. CCTA may be preferred given potentially better detection of atrial and ventricular thrombus. CLINICAL IMPACT. CCTA and CMRI have similar clinical performance as TTE for predicting cardioembolic stroke recurrence. This observation may be especially important when TTE provides equivocal findings.


Assuntos
Ecocardiografia/métodos , AVC Embólico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
World J Urol ; 38(11): 2971-2979, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31993735

RESUMO

PURPOSE: To assess a novel low-dose CT-protocol, combining a 150 kV spectral filtration unenhanced protocol (Sn150 kVp) and a stone-targeted dual-energy CT (DECT) in patients with urolithiasis. METHODS: 232 (151 male, 49 ± 16.4 years) patients with urolithiasis received a low-dose non-contrast enhanced CT (NCCT) for suspected urinary stones either on a third-generation dual-source CT system (DSCT) using Sn150 kVp (n = 116, group 1), or on a second-generation DSCT (n = 116 group 2) using single energy (SE) 120 kVp. For group 1, a subsequent dual-energy CT (DECT) with a short stone-targeted scan range was performed. Objective and subjective image qualities were assessed. Radiation metrics were compared. RESULTS: 534 stones (group 1: n = 242 stones; group 2: n = 292 stones) were found. In group 1, all 215 stones within the stone-targeted DECT-scan range were identified. DE analysis was able to distinguish between UA and non-UA calculi in all collected stones. 11 calculi (5.12%) were labeled as uric acid (UA) while 204 (94.88%) were labeled as non-UA calculi. There was no significant difference in overall Signal-to-noise-ratio between group 1 and group 2 (p = 0.819). On subjective analysis both protocols achieved a median Likert rating of 2 (p = 0.171). Mean effective dose was significantly lower for combined Sn150 kVp and stone-targeted DECT (3.34 ± 1.84 mSv) compared to single energy 120 kVp NCCT (4.45 ± 2.89 mSv) (p < 0.001), equaling a 24.9% dose reduction. CONCLUSION: The evaluated novel low-dose stone composition protocol allows substantial radiation dose reduction with consistent high diagnostic image quality.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
3.
Eur Radiol ; 28(3): 1267-1275, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28887662

RESUMO

OBJECTIVES: To evaluate a self-navigated free-breathing three-dimensional (SNFB3D) radial whole-heart MRA technique for assessment of main coronary arteries (CAs) and side branches in patients with congenital heart disease (CHD). METHODS: SNFB3D-MRA datasets of 109 patients (20.1±11.8 years) were included. Three readers assessed the depiction of CA segments, diagnostic confidence in determining CA dominance, overall image quality and the ability to freeze cardiac and respiratory motion. Vessel sharpness was quantitatively measured. RESULTS: The percentages of cases with excellent CA depiction were as follows (mean score): left main, 92.6 % (1.92); left anterior descending (LAD), 88.3 % (1.88); right (RCA), 87.8 % (1.85); left circumflex, 82.8 % (1.82); posterior descending, 50.2 % (1.50) and first diagonal, 39.8 % (1.39). High diagnostic confidence for the assessment of CA dominance was achieved in 56.2 % of MRA examinations (mean score, 1.56). Cardiac motion freezing (mean score, 2.18; Pearson's r=0.73, P<0.029) affected image quality more than respiratory motion freezing (mean score, 2.20; r=0.58, P<0.029). Mean quantitative vessel sharpness of the internal thoracic artery, RCA and LAD were 53.1, 52.5 and 48.7 %, respectively. CONCLUSIONS: Most SNFB3D-MRA examinations allow for excellent depiction of the main CAs in young CHD patients; visualisation of side branches remains limited. KEY POINTS: • Self-navigated free-breathing three-dimensional magnetic resonance angiography (SNFB3D-MRA) sufficiently visualises coronary arteries (CAs). • Depiction of main CAs in patients with congenital heart disease is excellent. • Visualisation of CA side branches using SNFB3D-MRA is limited. • SNFB3D-MRA image quality is especially correlated to cardiac motion freezing ability.


Assuntos
Vasos Coronários/patologia , Cardiopatias Congênitas/diagnóstico , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Respiração , Adulto Jovem
4.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
5.
Eur Radiol ; 28(5): 2134-2142, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29181587

RESUMO

OBJECTIVES: To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. METHODS: One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m2) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). RESULTS: Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P < 0.001) and radiation dose by 59.6% (4.3 vs. 10.6 mSv, P < 0.001). CONCLUSIONS: Automated tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. KEY POINTS: • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Idoso , Feminino , Seguimentos , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Curva ROC , Doses de Radiação
6.
Front Pediatr ; 10: 1005099, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36589159

RESUMO

It is an indisputable dogma in extremity radiography to acquire x-ray studies in at least two complementary projections, which is also true for distal radius fractures in children. However, there is cautious hope that computer vision could enable breaking with this tradition in minor injuries, clinically lacking malalignment. We trained three different state-of-the-art convolutional neural networks (CNNs) on a dataset of 2,474 images: 1,237 images were posteroanterior (PA) pediatric wrist radiographs containing isolated distal radius torus fractures, and 1,237 images were normal controls without fractures. The task was to classify images into fractured and non-fractured. In total, 200 previously unseen images (100 per class) served as test set. CNN predictions reached area under the curves (AUCs) up to 98% [95% confidence interval (CI) 96.6%-99.5%], consistently exceeding human expert ratings (mean AUC 93.5%, 95% CI 89.9%-97.2%). Following training on larger data sets CNNs might be able to effectively rule out the presence of a distal radius fracture, enabling to consider foregoing the yet inevitable lateral projection in children. Built into the radiography workflow, such an algorithm could contribute to radiation hygiene and patient comfort.

7.
PLoS One ; 16(1): e0245134, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411747

RESUMO

OBJECTIVES: To assess the feasibility of quantitative analysis of dynamic computed tomography angiography (dCTA) for the detection of endoleaks in patients who underwent endovascular repair of abdominal aortic aneurysms (EVAR). MATERIAL AND METHODS: Twenty patients scheduled for contrast-enhanced CT angiography (CTA) of the abdominal aorta post-EVAR were prospectively enrolled. All patients received a standard triphasic CTA protocol, followed by an additional dCTA. The dCTA acquisition enabled reconstruction of color-coded maps depicting blood perfusion and a dCTA dataset of the aneurysm sac. Observers assessed the dCTA and dynamic CT perfusion (dCTP) images for the detection of endoleaks, establishing diagnostic confidence based on a modified 5-point Likert scale. An index was calculated for the ratio between the endoleak and aneurysm sac using blood flow for dCTP and Hounsfield units (HU) for dCTA. The Wilcoxon test compared the endoleak index and the diagnostic confidence of the observers. RESULTS: In total, 19 patients (18 males, median age 74 years [70.5-75.7]) were included for analysis. Nine endoleaks were detected in 7 patients using triphasic CTA as the reference standard. There was complete agreement for endoleak detection between the two techniques on a per-patient basis. Both dCTA and dCTP identified an additional endoleak in one patient. The diagnostic confidence using dCTP for detection of endoleaks was not significantly superior to dCTA (5.0 [5-5] vs. 4.5 [4-5], respectively; p = 0.11); however, dCTP demonstrated superior diagnostic confidence for endoleak exclusion compared to dCTA (1.0 [1-1] vs 1.5 [1.5-1.5], respectively; p <0.01). Moreover, the dCTP endoleak index was significantly higher than the dCTA index (18.5 [10.8-20.5] vs. 3.5 [5-2.7], respectively; p = 0.02). CONCLUSIONS: Quantitative analysis of dCTP imaging can aid in the detection of endoleaks and demonstrates a higher endoleak detection rate than triphasic CTA, as well as a strong correlation with visual assessment of dCTA images.


Assuntos
Aorta Abdominal , Aneurisma da Aorta Abdominal , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/efeitos adversos , Idoso , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Humanos , Masculino
8.
PLoS One ; 15(2): e0228376, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32023294

RESUMO

OBJECTIVES: The purpose of this study was to investigate the impact of a 150kV spectral filtration chest imaging protocol (Sn150kVp) combined with advanced modeled iterative reconstruction (ADMIRE) on radiation dose and image quality in patients after lung-transplantation. METHODS: This study included 102 patients who had unenhanced chest-CT examinations available on both, a second-generation dual-source CT (DSCT) using standard protocol (100kVp, filtered-back-projection) and, on a third-generation DSCT using Sn150kVp protocol with ADMIRE. Signal-to-noise-ratio (SNR) was measured in 6 standardized regions. A 5-point Likert scale was used to evaluate subjective image quality. Radiation metrics were compared. RESULTS: The mean time interval between the two acquisitions was 1.1±0.7 years. Mean-volume-CT-dose-index, dose-length-product and effective dose were significantly lower for Sn150kVp protocol (2.1±0.5mGy;72.6±16.9mGy*cm;1.3±0.3mSv) compared to 100kVp protocol (6.2±1.8mGy;203.6±55.6mGy*cm;3.7±1.0mSv) (p<0.001), equaling a 65% dose reduction. All studies were considered of diagnostic quality. SNR measured in lung tissue, air inside trachea, vertebral body and air outside the body was significantly higher in 100kVp protocol compared to Sn150kVp protocol (12.5±2.7vs.9.6±1.5;17.4±3.6vs.11.8±1.8;0.7±0.3vs.0.4±0.2;25.2±6.9vs.14.9±3.3;p<0.001). SNR measured in muscle tissue was significantly higher in Sn150kVp protocol (3.2±0.9vs.2.6±1.0;p<0.001). For SNR measured in descending aorta there was a trend towards higher values for Sn150kVp protocol (2.8±0.6 vs. 2.7±0.9;p = 0.3). Overall SNR was significantly higher in 100kVp protocol (5.0±4.0vs.4.0±4.0;p<0.001). On subjective analysis both protocols achieved a median Likert rating of 1 (25th-75th-percentile:1-1;p = 0.122). Interobserver agreement was good (intraclass correlation coefficient = 0.73). CONCLUSIONS: Combined use of 150kVp tin-filtered chest CT protocol with ADMIRE allows for significant dose reduction while maintaining highly diagnostic image quality in the follow up after lung transplantation when compared to a standard chest CT protocol using filtered back projection.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pneumopatias/diagnóstico por imagem , Transplante de Pulmão/métodos , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Feminino , Humanos , Pneumopatias/cirurgia , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Estanho
9.
PLoS One ; 12(6): e0178747, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28570626

RESUMO

OBJECTIVES: To evaluate and compare surface doses of a cone beam computed tomography (CBCT) and a multidetector computed tomography (MDCT) device in pediatric ankle and wrist phantoms. METHODS: Thermoluminescent dosimeters (TLD) were used to measure and compare surface doses between CBCT and MDCT in a left ankle and a right wrist pediatric phantom. In both modalities adapted pediatric dose protocols were utilized to achieve realistic imaging conditions. All measurements were repeated three times to prove test-retest reliability. Additionally, objective and subjective image quality parameters were assessed. RESULTS: Average surface doses were 3.8 ±2.1 mGy for the ankle, and 2.2 ±1.3 mGy for the wrist in CBCT. The corresponding surface doses in optimized MDCT were 4.5 ±1.3 mGy for the ankle, and 3.4 ±0.7 mGy for the wrist. Overall, mean surface dose was significantly lower in CBCT (3.0 ±1.9 mGy vs. 3.9 ±1.2 mGy, p<0.001). Subjectively rated general image quality was not significantly different between the study protocols (p = 0.421), whereas objectively measured image quality parameters were in favor of CBCT (p<0.001). CONCLUSIONS: Adapted extremity CBCT imaging protocols have the potential to fall below optimized pediatric ankle and wrist MDCT doses at comparable image qualities. These possible dose savings warrant further development and research in pediatric extremity CBCT applications.


Assuntos
Tornozelo/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Doses de Radiação , Punho/diagnóstico por imagem , Criança , Humanos
10.
Am J Cardiol ; 119(8): 1156-1161, 2017 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-28233536

RESUMO

The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to-intermediate probability of coronary artery disease who underwent either third-generation dual-source cCTA using prospectively electrocardiography-triggered high-pitch spiral acquisition (n = 70) (group 1) or retrospective electrocardiography-gated cCTA on a 64-slice CT system (n = 70) (group 2). Contrast-to-noise and signal-to-noise ratios were measured within the aorta and coronary arteries. Subjective IQ was assessed using a 5-point Likert scale. Effective dose was estimated using specific conversion factors. The contrast-to-noise ratio of group 1 was significantly higher than group 2 at all levels (all p <0.001). Signal-to-noise ratio of group 1 was also significantly higher than group 2 (p <0.05), except for the distal left circumflex artery. Subjective IQ for group 1 was rated significantly better than for group 2 (median score [25th to 75th percentile]: 1 [1 to 2] vs 2 [2 to 3]; p <0.001). The median effective dose was 1.55 mSv (1.09 to 1.88) in group 1 versus 12.29 mSv (11.63 to 14.36) in group 2 (p <0.001) which corresponds to a mean radiation dose reduction of 87.4%. In conclusion, implementation of third-generation dual-source CT system for cCTA leads to improved IQ with significant radiation dose savings.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Angiografia Coronária/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA