Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Catheter Cardiovasc Interv ; 97(5): 797-804, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32198837

RESUMO

BACKGROUND: The COMBO drug eluting stent is a novel device with luminal endothelial progenitor cell capture technology for rapid homogeneous endothelialization. METHODS AND RESULTS: We examined for sex differences in 1-year outcomes after COMBO stenting from the COMBO collaboration, a pooled patient-level dataset from the MASCOT and REMEDEE multicenter registries. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR). Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. The study included 861 (23.8%) women and 2,753 (76.2%) men. Women were older with higher prevalence of several comorbidities including diabetes mellitus. Risk of 1-year TLF was similar in both sexes (3.8% vs. 3.9%, HR 0.92, 95% CI 0.59-1.42, p = .70), without sex differences in the incidence of cardiac death (1.6% vs. 1.5%, p = .78), TV-MI (1.5% vs. 1.1%, p = .32), or CD-TLR (2.0% vs. 2.2%, p = .67). Definite or probable ST occurred in 0.4% women and 1.0% men (HR 0.26, 95% CI 0.06-1.11, p = .069). CONCLUSIONS: Despite greater clinical risks at baseline, women treated with COMBO stents had similarly low 1-year TLF and other ischemic outcomes compared to men.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Caracteres Sexuais , Stents , Fatores de Tempo , Resultado do Tratamento
2.
Cardiovasc Drugs Ther ; 35(2): 309-320, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33515411

RESUMO

PURPOSE: The COMBO biodegradable polymer sirolimus-eluting stent includes endothelial progenitor cell capture (EPC) technology for rapid endothelialization, which may offer advantage in acute coronary syndromes (ACS). We sought to analyze the performance of the COMBO stent by ACS status and ACS subtype. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset from the MASCOT and REMEDEE registries. We evaluated outcomes by ACS status, and ACS subtype in patients with ST segment elevation myocardial infarction (STEMI) or non-STEMI (NSTEMI) versus unstable angina (UA). The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Secondary outcomes included stent thrombosis (ST). RESULTS: We compared 1965 (54%) ACS and 1649 (46.0%) non-ACS patients. ACS presentations included 40% (n = 789) STEMI, 31% (n = 600) NSTEMI, and 29% (n = 576) UA patients. Risk of 1-year TLF was greater in ACS patients (4.5% vs. 3.3%, HR 1.51 95% CI 1.01-2.25, p = 0.045) without significant differences in definite/probable ST (1.1% vs 0.5%, HR 2.40, 95% CI 0.91-6.31, p = 0.08). One-year TLF was similar in STEMI, NSTEMI, and UA (4.8% vs 4.8% vs. 3.7%, p = 0.60), but definite/probable ST was higher in STEMI patients (1.9% vs 0.5% vs 0.7%, p = 0.03). Adjusted outcomes were not different in MI versus UA patients. CONCLUSIONS: Despite the novel EPC capture technology, COMBO stent PCI was associated with somewhat greater risk of 1-year TLF in ACS than in non-ACS patients, without significant differences in stent thrombosis. No differences were observed in 1-year TLF among ACS subtypes.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Stents Farmacológicos/estatística & dados numéricos , Células Progenitoras Endoteliais/metabolismo , Intervenção Coronária Percutânea/métodos , Síndrome Coronariana Aguda/classificação , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/mortalidade , Angina Instável/complicações , Trombose Coronária/epidemiologia , Stents Farmacológicos/efeitos adversos , Humanos , Infarto do Miocárdio/classificação , Infarto do Miocárdio/complicações , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo
3.
Artigo em Inglês | MEDLINE | ID: mdl-32964556

RESUMO

BACKGROUND: Chronic kidney disease (CKD) patients undergoing percutaneous coronary intervention (PCI) experience greater ischemic events including clinically driven target lesion revascularization (CD-TLR). Whether the COMBO biodegradable-polymer sirolimus-eluting stent promotes better outcomes in these patients by virtue of endothelial progenitor cell capture technology is unknown. OBJECTIVE: We examined one-year outcomes by CKD status from the COMBO collaboration. METHODS: The COMBO collaboration was a patient-level pooled dataset from the REMEDEE and MASCOT registries (3,614 patients) of all-comers undergoing attempted COMBO stent PCI. The primary endpoint was one-year target lesion failure (TLF), composite of cardiac death, target-vessel myocardial infarction (TV-MI) or CD-TLR. Secondary endpoints included stent thrombosis (ST). RESULTS: The study included 6.4% (n = 231) CKD and 93.6% (n = 3,361) non-CKD patients. CKD patients were older and included more women with greater prevalence of several comorbidities but similar rate of acute coronary syndrome (50.6% vs. 54.5%, p = .26). CKD patients underwent radial PCI less often (56.1% vs. 70.3%, p < .001) and received clopidogrel (78.6% vs. 68.3%) more often (p = .004). One-year TLF occurred in 7.9% CKD vs. 3.7% non-CKD patients, p = .001. CKD patients also demonstrated greater incidence of cardiac death (6.2% vs. 1.2%, p < .0001), TV-MI (2.7% vs. 1.1%, p = .04) but similar CD-TLR (2.7% vs 2.2%, p = .61) and definite/probable ST (1.4% vs. 0.8%, p = .42), compared to non-CKD patients. CONCLUSIONS: CKD patients treated with COMBO stents had significantly greater incidence of one-year TLF compared to non-CKD patients driven by cardiac death and to a lesser extent TV-MI but not CD-TLR. They had similar rates of definite/probable ST.

4.
JACC Cardiovasc Interv ; 13(7): 820-830, 2020 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-32273094

RESUMO

OBJECTIVES: The aim of this study was to determine 1-year safety and efficacy after treatment with the COMBO and Orsiro stents. BACKGROUND: The COMBO stainless-steel stent has an anti-CD34+ antibody coating to capture endothelial progenitor cells, thereby promoting faster endothelialization. The Orsiro is an ultrathin-strut cobalt-chromium stent, covered by an extremely thin layer of amorphous silicon carbide to minimize ion leakage. Both devices elute sirolimus from biodegradable polymers. METHODS: For this analysis we included European patients from the COMBO collaboration, a patient-level pooling of 2 prospective all-comers registries of COMBO stent implantation (n = 2,775), and all patients randomized to the Orsiro stent (n = 1,169) from the Dutch BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) randomized trial. The main outcome of interest was 1-year target lesion failure, a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization evaluated using propensity score-matched analysis. RESULTS: At baseline, COMBO patients were older and had more insulin-treated diabetes, renal insufficiency, and other comorbidities. However, Orsiro patients included more current smokers and more acute coronary syndrome presentations. Orsiro patients also received longer stents and had more complex target lesions. After propensity score-matched analysis (n = 862/arm), 1-year target lesion failure occurred in 4.1% of COMBO-treated and 2.7% of Orsiro-treated patients (hazard ratio: 1.55; 95% confidence interval: 0.92 to 2.62; p = 0.10). Definite stent thrombosis occurred in 0.5% of COMBO-treated and 0.5% of Orsiro-treated patients (p = 0.99). CONCLUSIONS: A propensity score-matched comparison of all comers treated with the COMBO or Orsiro stent showed no statistically significant differences. Stent thrombosis risk was low and similar between the stents. (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population [BIO-RESORT], NCT01674803; MASCOT-Post Marketing Registry [MASCOT], NCT02183454; Prospective Registry to Assess the Long-term Safety and Performance of the Combo Stent [REMEDEE Reg], NCT01874002).


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Bases de Dados Factuais , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Pontuação de Propensão , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
5.
Int J Cardiol Heart Vasc ; 31: 100605, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32953969

RESUMO

BACKGROUND: The COMBO stent is a biodegradable-polymer sirolimus-eluting stent with endothelial progenitor cell capture technology for faster endothelialization. OBJECTIVE: We analyzed COMBO stent outcomes in relation to bleeding risk using the PARIS bleeding score. METHODS: MASCOT was an international registry of all-comers undergoing attempted COMBO stent implantation. We stratified patients as low bleeding-risk (LBR) for PARIS score ≤ 3 and intermediate-to-high (IHBR) for score > 3 based on baseline age, body mass index, anemia, current smoking, chronic kidney disease and need for triple therapy. Primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a non-target vessel or clinically-driven target lesion revascularization (TLR). Bleeding was adjudicated using the Bleeding Academic Research Consortium (BARC) definition. Dual antiplatelet therapy (DAPT) cessation was independently adjudicated. RESULTS: The study included 56% (n = 1270) LBR and 44% (n = 1009) IHBR patients. Incidence of 1-year TLF was higher in IHBR patients (4.1% vs. 2.6%, p = 0.047) driven by cardiac death (1.7% vs. 0.7%, p = 0.029) with similar rates of MI (1.8% vs. 1.1%, p = 0.17), TLR (1.5% vs. 1.6%, p = 0.89) and definite/ probable stent thrombosis (1.2% vs. 0.6%, p = 0.16). Incidence of 1-year major BARC 3 or 5 bleeding was significantly higher in IHBR patients (2.3% vs. 0.9%, p = 0.0094), as was the incidence of DAPT cessation (29.3% vs. 22.8%, p < 0.01), driven by physician-guided discontinuation. CONCLUSIONS: Patients with intermediate-to-high PARIS bleeding risk in the MASCOT registry experienced greater incidence of 1-year TLF, major bleeding and DAPT cessation than LBR patients, without significant differences in stent thrombosis.

6.
Am J Cardiol ; 127: 1-8, 2020 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-32418717

RESUMO

Older patients who undergo coronary interventions are at greater risk of ischemic events and less likely to tolerate prolonged dual antiplatelet therapy (DAPT) due to bleeding risk. The COMBO biodegradable polymer sirolimus-eluting stent promotes rapid endothelialization through endothelial progenitor cell capture technology which may be advantageous in elderly patients. We compared 1-year clinical outcomes and DAPT cessation events in patients >75 versus ≤75 years from the MASCOT registry. MASCOT was a prospective, multicenter cohort study of all-comers undergoing attempted COMBO stenting. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, myocardial infarction (MI) not clearly attributed to a nontarget vessel or clinically driven target lesion revascularization. Bleeding was adjudicated using the Bleeding Academic Research Consortium criteria. Adjusted outcomes were analyzed using Cox regression methods. The study included 18% (n = 479) patients >75 years and 72% (n = 2,135) patients ≤75 years. One-year TLF occurred in 4.6% patients >75 years versus 3.1% patients ≤75years of age, p = 0.10; adj hazard ratio 1.36, 95% confidence intervals 0.77 to 2.38, p = 0.29. There were no significant differences in cardiac death (1.7% vs 1.3%, p = 0.55), MI (2.1% vs 1.2%, p = 0.14), target lesion revascularization (1.7% vs 1.4%, p = 0.60) and definite stent thrombosis (0.8% vs 0.4%, p = 0.19). Major Bleeding Academic Research Consortium 3,5 bleeding (3.1% vs 1.5%, p = 0.01) and DAPT cessation rates (32.4% vs 23.0%, p <0.001) were significantly higher in elderly patients. In conclusion, elderly patients >75 years treated with COMBO stents had similar TLF but significantly greater incidence of bleeding than younger patients and DAPT cessation in one-third of patients over 1 year.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Polímeros , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Feminino , Saúde Global , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
7.
Int J Cardiol ; 307: 17-23, 2020 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-32111358

RESUMO

BACKGROUND: The COMBO drug-eluting stent combines sirolimus-elution from a biodegradable polymer with an anti-CD34+ antibody coating for early endothelialization. OBJECTIVE: We investigated for geographical differences in outcomes after percutaneous coronary intervention (PCI) with the COMBO stent among Asians and Europeans. METHODS: The COMBO Collaboration is a pooled patient-level analysis of the MASCOT and REMEDEE registries of all-comers undergoing attempted COMBO stent PCI. The primary outcome was 1-year target lesion failure (TLF), composite of cardiac death, target vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR). RESULTS: This study included 604 Asians (17.9%) and 2775 Europeans (82.1%). Asians were younger and included fewer females, with a higher prevalence of diabetes mellitus but lower prevalence of other comorbidities than Europeans. Asians had a higher prevalence of ACC/AHA C type lesions and received longer stent lengths. More Asians than Europeans were discharged on clopidogrel (86.5% vs 62.8%) rather than potent P2Y12 inhibitors. One-year TLF occurred in 4.0% Asians and 4.1% of Europeans, p = 0.93. The incidence of cardiac death was higher in Asians (2.8% vs. 1.3%, p = 0.007) with similar rates of TV-MI (1.5% vs. 1.2%, p = 0.54) and definite stent thrombosis (0.3% vs. 0.5%, p = 0.84) and lower incidence of TLR than Europeans (1.0% vs. 2.5%, p = 0.025). After adjustment, differences for cardiac death and TLR were no longer significant. CONCLUSIONS: In the COMBO collaboration, although 1-year TLF was similar regardless of geography, Asians experienced higher rates of cardiac death and lower TLR than Europeans, while incidence of TV-MI and ST was similar in both regions. Adjusted differences did not reach statistical significance. CLINICALTRIAL. GOV IDENTIFIER-NUMBERS: NCT01874002 (REMEDEE Registry), NCT02183454 (MASCOT registry).


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Ásia/epidemiologia , Doença da Artéria Coronariana/cirurgia , Europa (Continente)/epidemiologia , Feminino , Geografia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
8.
Cardiovasc Revasc Med ; 21(12): 1542-1547, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32507695

RESUMO

BACKGROUND: Small vessel diameter is associated with higher risk of target lesion revascularization (TLR) after percutaneous coronary intervention (PCI). The COMBO sirolimus-eluting biodegradable-polymer stent has a proprietary anti-CD34 antibody layer to enhance homogeneous endothelialization, which may be advantageous in treating small vessels. OBJECTIVE: We examined for differences in 1-year clinical outcomes after PCI by maximum implanted stent diameter from the COMBO collaboration. METHODS: The COMBO collaboration (n = 3614) is a patient-level pooled dataset of patients undergoing PCI with COMBO stents in the MASCOT and REMEDEE multicenter registries. Stent diameter was available in 3590 (99.3%) patients. We compared patients receiving COMBO stents <3 mm versus ≥3 mm. The primary endpoint was 1-year target lesion failure (TLF), composite of cardiac death, target vessel-myocardial infarction (TV-MI) or clinically driven TLR. Secondary outcomes included stent thrombosis (ST). Adjusted outcomes were assessed using Cox regression methods. RESULTS: The study included 792 (22%) patients with small stents <3 mm and 2798 (78%) patients with large stents ≥3 mm. Small stent patients included more women with lower body mass index and higher prevalence of diabetes but similar prevalence of acute coronary syndrome. Risk of 1-year TLF was similar in small and large stent groups (4.4% vs. 3.8%, HR 1.12, 95% CI 0.74-1.72, p = 0.58). There were no differences in the rates of cardiac death (1.7% vs. 1.5%, p = 0.74), TV-MI (1.4% vs. 1.2%, p = 0.58) or TLR (2.7% vs. 2.1%, p = 0.31). Definite or probable ST occurred in 1.3% of the small stent and 0.7% of the large stent PCI patients, p = 0.14, HR 2.13, 95% CI 0.93-5.00, p = 0.07. CONCLUSIONS: One-year ischemic outcomes after COMBO PCI were similar irrespective of stent diameter in this all-comers international cohort.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Stents , Feminino , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
9.
JACC Cardiovasc Interv ; 11(19): 1969-1978, 2018 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-30286855

RESUMO

OBJECTIVES: The aim of this study was to evaluate 1-year clinical safety and efficacy of the dual-therapy COMBO stent in a large, all-comers patient-level pooled cohort. BACKGROUND: The COMBO stent (OrbusNeich Medical, Fort Lauderdale, Florida) is a novel stent with abluminal sirolimus elution from a biodegradable polymer and a luminal pro-healing anti-CD34+ antibody layer, which attracts circulating endothelial progenitor cells. These endothelial progenitor cells can quickly mature into normal endothelium, providing rapid endothelialization. METHODS: The MASCOT (Multinational Abluminal Sirolimus Coated biO-engineered stenT) (N = 2,614, 61 global sites) and REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coatED bio-Engineered StEnt Post Market Registry) (N = 1,000, 9 European sites) registries are 2 prospective, multicenter studies evaluating clinical outcomes after attempted COMBO stent placement in all-comer patients undergoing percutaneous coronary intervention. In this patient-level pooled analysis we analyzed 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Furthermore, we determined predictors of 1-year TLF. RESULTS: A total of 3,614 patients (63.5 ± 11.2 years of age; 23.8% women) were included in this analysis. The prevalence of diabetes mellitus was 29.3%, and 54.3% patients presented with acute coronary syndrome. The primary endpoint of 1-year TLF occurred in 140 (3.9%) patients, with incidence of cardiac death in 1.6%, target vessel myocardial infarction in 1.2%, clinically driven target lesion revascularization in 2.2%, and definite stent thrombosis in 0.5% patients. Insulin-treated diabetes mellitus, chronic renal failure, and American College of Cardiology/American Heart Association lesion type B2/C were independent predictors of 1-year TLF. CONCLUSIONS: In this large patient-level pooled analysis of patients treated with the dual-therapy COMBO stent excellent results at 1-year were observed. (MASCOT - Post Marketing Registry [MASCOT]; NCT02183454; Prospective Registry to Assess the Long-term Safety and Performance of the COMBO Stent [REMEDEE Reg]; NCT01874002).


Assuntos
Implantes Absorvíveis , Anticorpos/administração & dosagem , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Anticorpos/efeitos adversos , Antígenos CD34/imunologia , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/imunologia , Doença da Artéria Coronariana/mortalidade , Células Progenitoras Endoteliais/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Vigilância de Produtos Comercializados , Reepitelização , Sistema de Registros , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
10.
Circ Cardiovasc Interv ; 11(3): e006144, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29870385

RESUMO

BACKGROUND: Patients with chronic kidney disease (CKD) experience high rates of ischemic and bleeding events after percutaneous coronary intervention (PCI), complicating decisions surrounding dual antiplatelet therapy (DAPT). This study aims to determine the pattern and impact of various modes of DAPT cessation for patients with CKD undergoing PCI. METHODS AND RESULTS: Patients from the PARIS registry (Patterns of Non-Adherence to Anti-Platelet Regimens in Stented Patients) were grouped based on the presence of CKD defined as creatinine clearance <60 mL/min. After index PCI, time and mode of DAPT cessation (discontinuation, interruption, and disruption) and clinical outcomes (major adverse cardiac events, stent thrombosis, myocardial infarction, and major bleeding [Bleeding Academic Research Consortium type 3 or 5]) were reported. Over 2 years, patients with CKD (n=839) had higher adjusted risks for death (hazard ratio, 3.16; 95% confidence interval, 2.26-4.41), myocardial infarction (hazard ratio, 2.43; 95% confidence interval, 1.65-3.57), and major bleeding (hazard ratio, 2.21; 95% confidence interval, 1.53-3.19) compared with patients without CKD (n=3745). Rates of DAPT discontinuation within the first year after PCI and disruption were significantly higher for patients with CKD. However, DAPT interruption occurred with equal frequency. Associations between DAPT cessation mode and subsequent risk were not modified by CKD status. Findings were unchanged after propensity matching. CONCLUSIONS: Patients with CKD display high and comparable risks for both ischemic and bleeding events after PCI. Physicians are more likely to discontinue DAPT within the first year after PCI among patients with CKD, likely reflecting clinical preferences to avoid bleeding. Risks after DAPT cessation, irrespective of underlying mode, are not modified by the presence or absence of CKD.


Assuntos
Doença da Artéria Coronariana/cirurgia , Fidelidade a Diretrizes/tendências , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Padrões de Prática Médica/tendências , Insuficiência Renal Crônica/epidemiologia , Idoso , Tomada de Decisão Clínica , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Esquema de Medicação , Quimioterapia Combinada , Europa (Continente)/epidemiologia , Feminino , Hemorragia/induzido quimicamente , Hemorragia/mortalidade , Humanos , Incidência , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Sistema de Registros , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Insuficiência Renal Crônica/fisiopatologia , Medição de Risco , Fatores de Risco , Trombose/mortalidade , Trombose/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
11.
Circ Cardiovasc Interv ; 10(9)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28916600

RESUMO

BACKGROUND: Elevated white blood cell (WBC) count is associated with increased major adverse cardiovascular events (MACE) in the setting of acute coronary syndrome. The aim of this study was to evaluate whether similar associations persist in an all-comers population of patients undergoing percutaneous coronary intervention in the contemporary era. METHODS AND RESULTS: In the multicenter, prospective, observational PARIS study (Patterns of Non-Adherence to Anti-Platelet Regimens in Stented Patients Registry), 4222 patients who underwent percutaneous coronary intervention in the United States and Europe between July 1, 2009, and December 2, 2010, were evaluated. The associations between baseline WBC and MACE (composite of cardiac death, stent thrombosis, spontaneous myocardial infarction, or target lesion revascularization) at 24-month follow-up were analyzed using multivariable Cox regression. Patients with higher WBC were more often younger, smokers, and with less comorbid risk factors compared with those with lower WBC. After adjustment for baseline and procedural characteristics, WBC remained independently associated with MACE (hazard ratio [HR] per 103 cells/µL increase, 1.05 [95% confidence intervals (CI), 1.02-1.09]; P=0.001), cardiac death (HR, 1.10 [95% CI, 1.05-1.17]; P<0.001), and clinically indicated target revascularization (HR, 1.04 [95% CI, 1.00-1.09]; P=0.03) but not stent thrombosis (HR, 1.07 [95% CI, 0.99-1.16]; P=0.10) or spontaneous myocardial infarction (HR, 1.03 [95% CI, 0.97-1.09]; P=0.29). The association between WBC and MACE was consistent in acute coronary syndrome and non-acute coronary syndrome presentations (interaction P=0.15). CONCLUSIONS: Increased WBC is an independent predictor of MACE after percutaneous coronary intervention in a contemporary all-comers cohort. Further studies to delineate the underlying pathophysiologic role of elevated WBC across a spectrum of coronary artery disease presentations are warranted. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00998127.


Assuntos
Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/terapia , Leucócitos , Adesão à Medicação , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/mortalidade , Idoso , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Quimioterapia Combinada , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Retratamento , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA