Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Pacing Clin Electrophysiol ; 47(3): 417-428, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38375940

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common heart rhythm disorder that is associated with an increased risk of stroke and heart failure (HF). Initially, an association between AF and ion channel dysfunction was identified, classifying the pathology as a predominantly electrical disease. More recently it has been recognized that fibrosis and structural atrial remodeling play a driving role in the development of this arrhythmia also in these cases. PURPOSE: Understanding the role of fibrosis in genetic determined AF could be important to better comprise the pathophysiology of this arrhythmia and to refine its management also in nongenetic forms. In this review we analyze genetic and epigenetic mechanisms responsible for AF and their link with atrial fibrosis, then we will consider analogies with the pathophysiological mechanism in nongenetic AF, and discuss consequent therapeutic options.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/complicações , Átrios do Coração , Fibrose , Canais Iônicos/genética , Canais Iônicos/uso terapêutico
2.
Pacing Clin Electrophysiol ; 46(1): 39-43, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35941725

RESUMO

Leadless pacemaker implantation (LPI) has fewer device complications and reduced chance of infection compared to conventional pacemakers. Dextrocardia with situs viscerum inversus (DC+SVI) is a rare condition, which seldom leads to cardiac complications. However, its presence poses a challenge to operators in cardiac procedures. LPI reports in DC patients are scarce. We report a case of LPI in a DC+SVI patient, followed by a brief but comprehensive literature review.


Assuntos
Dextrocardia , Marca-Passo Artificial , Situs Inversus , Humanos , Dextrocardia/complicações , Situs Inversus/complicações , Situs Inversus/terapia
3.
Pacing Clin Electrophysiol ; 46(7): 674-683, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37279193

RESUMO

INTRODUCTION: Permanent His bundle pacing (HBP) is the most physiological pacing modality, and new implantation systems are now available. The aim of the present study was to describe and compare four different techniques to perform HBP. METHODS AND RESULTS: We included all consecutive patients who underwent a HBP attempt in our initial experience between June 2020 and May 2022. The success and characteristics of the procedure were compared among four implantation techniques: the Biotronik Selectra 3D sheath with Solia S60 lead (Selectra 3D), the Boston Scientific Site Selective Pacing Catheter with Ingevity lead (SSPC), the Abbott steerable stylet locator with Tendril lead (Locator), and the use of a standard stylet manually pre-shaped with a conventional pacing lead (Curved stylet). Ninety-eight patients (median age 79 years [interquartile range, 73-83], 83% men) were identified. The Selectra 3D technique was used in 43 procedures, SSPC in 26, Locator in 18 and Curved stylet in 11. The groups had similar clinical characteristics. Overall, procedural success was achieved in 91 patients (93%) with similar proportions among groups (p = .986). Fluoroscopy and procedural times were 6.0 (4.4-8.5) and 60 (45-75) min, respectively, without significant differences (p = .333 and p = .790). The rate of selective capture, the pacing threshold, and the paced QRS duration were also comparable. There was one pre-discharge HBP lead dislodgment (1%) that required implant revision. CONCLUSION: In our experience, four techniques for HBP achieved comparable results in terms of safety and effectiveness. The availability of different systems may lead to widespread use of physiological pacing.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Masculino , Humanos , Idoso , Feminino , Estimulação Cardíaca Artificial/métodos , Resultado do Tratamento , Cateterismo Cardíaco , Estudos Retrospectivos , Eletrocardiografia/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-37930655

RESUMO

We report the case of a 62-year-old man who was admitted to the Cardiac Department for TakoTsubo and ACC by torsades de point, secondary to acute kidney disease. We decide to discharge with a portable defibrillator. One month after cardiac magnetic resonance showed a complete recovery of left ventricular function.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37930657

RESUMO

Myocarditis is a potentially fatal complication of coronavirus disease 2019 (COVID-19), which is caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. COVID-19 myocarditis appears to have distinct inflammatory characteristics that distinguish it from other viral etiologies. COVID-19 myocarditis can present with symptoms ranging from dyspnea and chest pain to acute heart failure and death. It is critical to detect any cases of myocarditis, especially fulminant myocarditis, which can be characterized by signs of heart failure and arrhythmias. Serial troponins, echocardiography, and electrocardiograms should be performed as part of the initial workup for suspected myocarditis. The second step in detecting myocarditis is cardiac magnetic resonance imaging and endomyocardial biopsy. Treatment for COVID-19 myocarditis is still debatable; however, combining intravenous immunoglobulins and corticosteroids may be effective, especially in cases of fulminant myocarditis. Overall, more research is needed to determine the incidence of COVID-19 myocarditis , and the use of intravenous immunoglobulins and corticosteroids in combination requires large randomized controlled trials to determine efficacy. The purpose of this review is to summarize current evidence on the subject. This review aims to summarise current evidence on this topic.

6.
J Cardiovasc Electrophysiol ; 33(5): 1034-1040, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35243712

RESUMO

INTRODUCTION: We hypothesized that an accurate assessment of preoperative venography could be useful in predicting transvenous lead extraction (TLE) difficulty. METHODS AND RESULTS: A dedicated preoperative venogram was performed in consecutive patients with cardiac implantable electronic device who underwent TLE. The level of stenosis was classified as without significant stenosis, moderate, severe, and occlusion. The presence of extensive lead-venous wall adherence (≥50 mm) was also assessed. A total of 105 patients (median age: 71 years; 72% male) with a median of 2 (1-2) leads to extract were enrolled. Preoperative venography showed moderate to severe stenosis in 31 (30%), complete occlusion in 15 (14%), and extensive lead-venous wall adherence in 50 (48%) patients. Complete TLE success was achieved in 103 (98%) patients. A total of 55 (52%) were advanced extractions as they required a powered mechanical and/or laser sheath. They were more prevalent in the group with extensive lead-venous wall adherence (72% vs. 34%, p < .001), while no differences were found between patients with and without venous occlusion. In multivariate analysis, the presence of adherence was a predictor of advanced extraction (odds ratio: 2.89 [1.14-7.32], p = .025). The fluoroscopy time was also significantly longer (14.0 [8.2-18.7] vs. 5.1 [2.1-10.0] min, p < .001). The rate of complications did not differ based on the presence of venous lesions. CONCLUSION: Although procedural success and complication rates were similar, patients with extensive lead-venous wall adherence required a longer fluoroscopy time and were three times more likely to need advanced extraction tools. Conversely, the presence of total venous occlusion had no impact on the procedure complexity.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Doenças Vasculares , Idoso , Constrição Patológica , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Flebografia , Estudos Retrospectivos , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 33(10): 2195-2201, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35842805

RESUMO

INTRODUCTION: The prevalence and impact of pulmonary embolism (PE) in patients with lead-related infective endocarditis undergoing transvenous lead extraction (TLE) are unknown. METHODS: Twenty-five consecutive patients with vegetations ≥10 mm at transoesophageal echocardiography were prospectively studied. Contrast-enhanced chest computed tomography (CT) was performed before (pre-TLE) and after (post-TLE) the lead extraction procedure. RESULTS: Pre-TLE CT identified 18 patients (72%) with subclinical PE. The size of vegetations in patients with PE did not differ significantly from those without (median 20.0 mm [interquartile range: 13.0-30.0] vs. 14.0 mm [6.0-18.0], p = 0.116). Complete TLE success was achieved in all patients with 3 (2-3) leads extracted per procedure. There were no postprocedure complications related to the presence of PE and no differences in terms of fluoroscopy time and need for advanced tools. In the group of positive pre-TLE CT, post-TLE scan confirmed the presence of silent PE in 14 patients (78%). There were no patients with new PE formation. Large vegetations (≥20 mm) tended to increase the risk of post-TLE subclinical PE (odds ratio 5.99 [95% confidence interval (CI): 0.93-38.6], p = 0.059). During a median 19.4 months follow-up, no re-infection of the implanted system was reported. Survival rates in patients with and without post-TLE PE were similar (hazard ratio: 1.11 [95% CI: 0.18-6.67], p = 0.909). CONCLUSION: Subclinical PE detected by CT was common in patients undergoing TLE with lead-related infective endocarditis and vegetations but was not associated with the complexity of the procedure or adverse outcomes. TLE procedure seems safe and feasible even in patients with large vegetations.


Assuntos
Desfibriladores Implantáveis , Endocardite Bacteriana , Endocardite , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Embolia Pulmonar , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Endocardite/diagnóstico por imagem , Endocardite/epidemiologia , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/epidemiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Prevalência , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Embolia Pulmonar/terapia , Estudos Retrospectivos
8.
Pacing Clin Electrophysiol ; 45(7): 861-865, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35596733

RESUMO

BACKGROUND: Transvenous lead extraction is the standard therapy for cardiac device-related infection. In some patients, however, a hybrid surgical and transvenous approach may be necessary. METHODS AND RESULTS: We present three cases who underwent transvenous lead extraction for an infected CRT-D system. In all cases the CS lead could not be retrieved transvenously due to extensive fibrosis. The lead was successfully extracted through left minithoracotomy in two patients and midline sternotomy in one patient. CONCLUSION: In cases where the coronary sinus lead shows severe fibrosis, a transvenous approach can be used to free the proximal part of the lead, while the distal adhesions can be removed surgically through a limited thoracic incision.


Assuntos
Seio Coronário , Desfibriladores Implantáveis , Seio Coronário/cirurgia , Remoção de Dispositivo , Fibrose , Humanos , Toracotomia , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 45(9): 1051-1055, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35579295

RESUMO

Superior vena cava (SVC) syndrome is a rare disease induced by thrombosis and consequent occlusion of SVC, negatively affecting morbidity and mortality. The incidence of SVC syndrome from central venous catheters and pacemaker or defibrillator leads is increasing. Optimal treatment of pacemaker or defibrillator-related SVC syndrome is not well defined. Lead extraction causes mechanical trauma to the vessel wall. In addition, subsequent device implantation on the contralateral side can be an added factor for venous occlusion. The use of leadless pacemakers could be an interesting option to reduce the risk of SVC restenosis after lead extraction. We report a clinical case of PM leads-related SVC syndrome referred to our centers and treated with transvenous lead extraction, leadless pacemaker implantation and subsequent percutaneous angioplasty and stenting of the SVC and left innominate vein.


Assuntos
Marca-Passo Artificial , Síndrome da Veia Cava Superior , Trombose , Humanos , Marca-Passo Artificial/efeitos adversos , Stents/efeitos adversos , Síndrome da Veia Cava Superior/cirurgia , Síndrome da Veia Cava Superior/terapia , Trombose/complicações , Veia Cava Superior
10.
Monaldi Arch Chest Dis ; 93(2)2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35872629

RESUMO

We report the case of a 47-year-old woman who was admitted to the cardiac department for worsening dyspnea. The last chest computed tomography (CT) showed a rapid increase in pulmonary artery dimension (65 mm in 2019, 76 mm in 2021). The symptoms reported by the patient were due to important extrinsic compression of the left main coronary artery (LMCA). In this case, it is very difficult to choose the best therapeutic strategy. In the end, we decided to treat the left main coronary for prevention. After 3 months no new clinical symptoms have developed.


Assuntos
Estenose Coronária , Cardiopatias Congênitas , Hipertensão Pulmonar , Feminino , Humanos , Pessoa de Meia-Idade , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Artéria Pulmonar/diagnóstico por imagem , Dilatação , Angiografia Coronária
11.
Monaldi Arch Chest Dis ; 93(2)2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36128930

RESUMO

Varicella zoster virus (VZV) is a Herpesviridae family double-stranded DNA virus that only affects humans. The first clinical manifestation appears to be varicella, typical of childhood. VZV, on the other hand, becomes latent in ganglion neurons throughout the neuroaxis after primary infection. The VZV reactivates and travels along peripheral nerve fibers in the elderly and immunocompromised individuals, resulting in Zoster. It can, however, spread centrally and infect cerebral and extracranial arteries, resulting in vasculopathy, which can lead to transient ischemic attacks, strokes, aneurysms, cavernous sinus thrombosis, giant cell arteritis, and granulomatous aortitis. Although the mechanisms of virus-induced pathological vascular remodeling are not fully understood, recent research indicates that inflammation and dysregulation of ligand-1 programmed death play a significant role. Few studies, on the other hand, have looked into the role of VZV in cardiovascular disease. As a result, the purpose of this review is to examine the relationship between VZV and cardiovascular disease, the efficacy of the vaccine as a protective mechanism, and the target population of heart disease patients who could benefit from vaccination.


Assuntos
Doenças Cardiovasculares , Varicela , Herpes Zoster , Acidente Vascular Cerebral , Humanos , Idoso , Herpesvirus Humano 3 , Doenças Cardiovasculares/epidemiologia , Herpes Zoster/epidemiologia , Herpes Zoster/prevenção & controle , Acidente Vascular Cerebral/epidemiologia
12.
Medicina (Kaunas) ; 59(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36676690

RESUMO

Background. Data on leadless pacemaker (LPM) implantation in an emergency setting are currently lacking. Objective. We aimed to investigate the feasibility of LPM implantation for emergency bradyarrhythmia, in patients referred for urgent PM implantation, in a large, multicenter, real-world cohort of LPM recipients. Methods. Two cohorts of LPM patients, stratified according to the LPM implantation scenario (patients admitted from the emergency department (ED+) vs. elective patients (ED−)) were retrieved from the iLEAPER registry. The primary outcome of the study was a comparison of the peri-procedural complications between the groups. The rates of peri-procedural characteristics (overall procedural and fluoroscopic duration) were deemed secondary outcomes. Results. A total of 1154 patients were enrolled in this project, with patients implanted due to an urgent bradyarrhythmia (ED+) representing 6.2% of the entire cohort. Slow atrial fibrillation and complete + advanced atrioventricular blocks were more frequent in the ED+ cohort (76.3% for ED+ vs. 49.7% for ED−, p = 0.025; 37.5% vs. 27.3%, p = 0.027, respectively). The overall procedural times were longer in the ED+ cohort (60 (45−80) mins vs. 50 (40−65) mins, p < 0.001), showing higher rates of temporary pacing (94.4% for ED+ vs. 28.9% for ED−, p < 0.001). Emergency LPM implantation was not correlated with an increase in the rate of major complications compared to the control group (6.9% ED+ vs. 4.2% ED−, p = 0.244). Conclusion. LPM implantation is a feasible procedure for the treatment of severe bradyarrhythmia in an urgent setting. Urgent LPM implantation was not correlated with an increase in the rate of major complications compared to the control group, but it was associated with longer procedural times.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Bradicardia/terapia , Fibrilação Atrial/terapia , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 32(5): 1407-1410, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33783892

RESUMO

PURPOSE: Predictors of difficulty and complications of transvenous lead extraction (TLE) have been investigated in several studies; however, little is known about the venous anatomical characteristics that can have an impact on procedural outcomes. Among them, the persistent left superior vena cava (PLSVC) is a common anomaly often discovered incidentally during cardiac device implantation and could raise concerns if TLE is indicated. We report technical considerations and outcomes of TLE for two patients with leads implanted via PLSVC. METHODS AND RESULTS: Two cardiac implantable electronic device recipients with isolated PLSVC required TLE due to infective endocarditis in one case and lead failure in the other. In the first case, TLE procedure was performed in a hybrid operating room with minimally invasive video-assisted thoracoscopic monitoring due to the high procedural risk. Two active fixation 20-year-old pacing leads were removed with a relatively short fluoroscopy time. In the second case, we successfully extracted a single-coil active fixation lead without the need of a locking stylet or advanced extraction tools. There were no procedural complications or adverse events at 1-year follow-up. CONCLUSION: TLE procedures for two patients with isolated PLSVC were successfully completed with less difficulty and tools than expected based on the characteristics of the targeted leads. If indicated, TLE in the presence of a PLSVC should be considered in experienced centers.


Assuntos
Veia Cava Superior Esquerda Persistente , Veia Cava Superior , Remoção de Dispositivo , Fluoroscopia , Humanos , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
14.
Pacing Clin Electrophysiol ; 43(12): 1428-1437, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33089526

RESUMO

Theleadless pacemaker (LLPM) therapy has been developed in recent years to overcome the transvenous lead and device pocket-related complications. The LLPMs now available are self-contained right ventricular pacemakers and are limited to single-chamber ventricular pacing modality. This literature review deals with the current status of LLPM technology and current areas of clinical applicability. The safety and efficacy outcomes published from randomized clinical trials and real world registries are analyzed and compared with historical conventional transvenous pacemaker data. Furthermore, new pacing modalities and future perspectives to broaden the clinical use and cover most of pacing indications are discussed. Due to the overall safe and effective profile in the short term and intermediate term, also in fragile patients, the LLPM use is constantly growing in daily clinical practice. Actually, it can be considered a landmark innovation, through which a new era of cardiac pacing has begun.


Assuntos
Arritmias Cardíacas/terapia , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Desenho de Equipamento , Humanos
16.
Ann Cardiothorac Surg ; 13(1): 44-53, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38380141

RESUMO

Atrial fibrillation (AF) has been reported as a major cause of cardiac morbidity and mortality, and significantly reduces the quality of life in symptomatic patients. Current guidelines recommend antiarrhythmic drugs and catheter ablation (CA) as first-line therapy. Despite CA showed to be associated with lower incidence of peri-procedural complications, rhythm outcomes are far from optimal. Indeed, patients undergoing CA frequently require multiple AF ablation procedures, especially in those with persistent and long-standing persistent AF. While surgical ablation can provide transmural lesions, surgical invasiveness has limited the widespread use of this approach due to the increased perioperative complications. The development of minimally invasive thoracoscopic approaches has renewed the interest towards surgical ablation, thus favoring more simplified ablation sets. Therefore, the concept of "hybrid" ablation has emerged in order to theoretically enhance advantages of both minimally invasive and CA procedures while seeking to improve rhythm outcomes and reduce invasiveness and incidence of perioperative complications. On one hand, it provides the effectiveness of a surgical ablation, on the other, electrical mapping during CA can identify and treat any ablation gap or provide additional ablation lines, thus improving the chance of a stable sinus rhythm restoration at long-term follow-up. Three main thoracoscopic strategies are currently available. All of them can be performed in conjunction with the "catheter ablation procedure": the "Fusion" technique, the bipolar clamp technique, and the most recent "convergent" technique. CA can be performed either simultaneously or with a staged approach after a blanking period in order to allow the ablation lesion to stabilize. Excellent results of the hybrid procedures have been reported in terms of rhythm outcomes and incidence of perioperative complications. This narrative review aims to discuss the rationale behind the concept of hybrid ablation for the treatment of AF regarding different available strategies, results and expert opinions.

17.
J Interv Card Electrophysiol ; 67(3): 439-441, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38099975

RESUMO

ESC Guidelines don't recommend ICD implantation within 40 days after MI, on the basis of old evidence with several limitations. However, a significant number of patients remain at high risk of arrhythmic death also in the early period after ACS, in these patients early ICD implantation or LifeVest may be use with benefit on survival.


Assuntos
Desfibriladores Implantáveis , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/terapia , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
18.
Int J Cardiol Heart Vasc ; 51: 101371, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38435380

RESUMO

Background: This study aimed to investigate the characteristics and outcomes of patients diagnosed with Brugada syndrome (BrS) who underwent implantable loop recorder (ILR) insertion during routine clinical activity. Methods: We conducted a comprehensive screening of all consecutive patients diagnosed with BrS at our institution. We analyzed baseline clinical characteristics, arrhythmic findings, and outcomes. Results: Out of 147 BrS patients, 42 (29 %) received an ILR, 13 (9 %) underwent implantable cardioverter-defibrillator (ICD) placement, and 92 patients (63 %) continued regular cardiological follow-up. Patients who received an ILR had a higher prevalence of suspected arrhythmic syncope (43 % vs. 22 %, p = 0.012) and tended to be younger (median age 38 years, interquartile range 30-52, vs. 43 years, 35-55, p = 0.044) with a higher presence of SCN5A gene mutations (17 % vs. 6 %, p = 0.066) compared to those who continued regular follow-up. Additionally, compared to patients with an ICD, those with an ILR had a significantly lower frequency of positive programmed ventricular stimulation (0 % vs. 91 %, p < 0.001). During a median follow-up period of 14.7 months (4.7-44.8), no deaths occurred among the patients with ILR. Eight individuals (19 %) were diagnosed with arrhythmic findings through continuous ILR monitoring, primarily atrial fibrillation, and asystolic pauses. The median time from insertion to the occurrence of these events was 8.7 months (3.6-46.4). No adverse events related to ILR were reported. Conclusion: Continuous monitoring with ILR may facilitate the timely detection of non-malignant rhythm disorders in BrS patients with risk factors but without an indication for primary prevention ICD implantation.

19.
J Cardiovasc Med (Hagerstown) ; 25(2): 95-103, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38149699

RESUMO

In the latest ESC/EACTS Guidelines for the Management of Valvular Heart Disease, right ventricular dilatation and dysfunction, severe pulmonary hypertension and tricuspid annulus dilatation were reported to be the most important parameters to consider in patient selection for tricuspid valve interventions. Indeed, comprehensive right ventricular assessment is crucial in patients with severe tricuspid regurgitation who may benefit from transcatheter or surgical procedures. However, the only guideline parameter considered for intervention has been tricuspid annular dilatation in the presence of at least mild to moderate tricuspid regurgitation, with no other right ventricular markers used in the decision-making process for invasive treatment. Notably, challenges in the assessment of right ventricular function may limit establishing thresholds for defining right ventricular dysfunction. The aim of this review is to summarize current evidence on the prognostic significance of right ventricular function in patients with tricuspid regurgitation undergoing percutaneous or surgical interventions.


Assuntos
Doenças das Valvas Cardíacas , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Ventrículos do Coração , Prognóstico , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia
20.
Acta Cardiol ; 78(9): 992-999, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37318077

RESUMO

BACKGROUND: A complex transvenous lead extraction (TLE) procedure could be associated with lower success and higher complication rates in inexperienced hands. In this study, we aim to assess the factors that determine procedural difficulty in TLE. METHODS: We retrospectively studied 200 consecutive patients undergoing TLE in a single referral centre from June 2020 to December 2021. Lead extraction difficulty was assessed by the success of simple manual traction with or without a locking stylet, the need for advanced extraction tools and the number of tools required to extract the lead. Logistic and linear regression analyses were used to determine the factors independently affecting these 3 parameters. RESULTS: 363 leads were extracted from 200 patients (79% males, mean age 66.85 years). The indication for TLE was device-related infection in 51.5%. Multivariate analysis revealed the lead indwelling time to be the only factor affecting the 3 parameters of difficulty. Passive fixation leads and dual coil leads increased procedural difficulty by affecting 2 parameters each. Factors that affected one parameter included infected leads, coronary sinus leads, older age of the patient and a history of valvular heart disease, all associated with a simpler procedure. Right ventricular leads were associated with a more complex one. CONCLUSION: The most important factor that increased TLE procedural difficulty was a longer lead indwelling time, followed by passive fixation and dual-coil leads. Other contributing factors were the presence of infection, coronary sinus leads, older patients, a history of valvular heart disease and right ventricular leads.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA