Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Int Ophthalmol ; 41(6): 2041-2052, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33655389

RESUMO

PURPOSE: To investigate the long-term effectiveness of non-penetrating deep sclerectomy (NPDS) with xenogenically derived cancellous bone collagen glaucoma implant (XCB-CGI) implantation in patients with primary open-angle glaucoma (POAG). MATERIALS AND METHODS: Retrospective chart review of patients with POAG stages 2 and 3 was treated with NPDS and XCB-CGI. Follow-up was at 6 months, 1, 2, 3, 4 and 5 years after surgery. Main outcomes were intraocular pressure (IOP) and medication burden. Secondary outcomes were visual acuity, corneal hysteresis (CH), visual field (VF) and optical coherence tomography (OCT) parameter analysis. RESULTS: Among 71 patients (71 eyes), the mean age was 72.7 ± 9.8. Average initial IOP was 27.7 ± 7.9 and average initial med load was 2.36 ± 0.99. At 6 months, 1, 2, 3, 4 and 5 years, the average IOP was 14.9 ± 3.3 mm Hg (46.2% reduction), 15.3 ± 4.0 mm Hg (44.7% reduction), 14.2 ± 3.8 mm Hg (48.7% reduction), 15.2 ± 3.3 mm Hg (45.0% reduction), 15.5 ± 3.3 mm Hg (44.0% reduction) and 14.2 ± 2.8 mm Hg (48.7% reduction), respectively. In 5 years, the success rate was 34% and 67%, without, and with medications (1.8 ± 0.8 meds required), respectively. Visual acuity was not significantly different (P > .05) at all follow-up visits from baseline. Mean CH increased by 2.1 ± 0.8 (P = .05). No glaucomatous deterioration of the VF and OCT parameters was detected in 56 eyes at the 5-year follow-up. CONCLUSION: NPDS with XCB-CGI implantation is an effective procedure to normalize the level of IOP, stabilize glaucomatous changes and decrease the number of meds needed for glaucoma control.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Esclerostomia , Idoso , Idoso de 80 Anos ou mais , Osso Esponjoso , Colágeno , Seguimentos , Glaucoma/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
2.
Saudi J Ophthalmol ; 36(2): 149-156, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211323

RESUMO

This article reviews the history and technique of primary posterior capsulorhexis with emphasis on anterior hyaloid membrane preservation and combined posterior optic capture of intraocular lenses into Berger's space for the purpose of lens stability and secondary cataract elimination among other potential advantages. Applications, variations, efficacy, and safety of the procedure are reviewed.

3.
J Cataract Refract Surg ; 48(6): 745-749, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35347097

RESUMO

A new surgical technique of transscleral-intracorneal suture fixation of intraocular lenses with suture ends located within the transparent corneal or corneal-limbal paracentesis is reported. This new technique significantly reduces scleral and conjunctival trauma, is minimally invasive, is simple to perform, is not associated with complicated intraocular surgical maneuvers, and precludes suture knot, flange, and suture-end erosion. The internal part of the corneal stroma or corneal-limbal area serves as a secure depot for suture-end fixation with durable resistance. The technique enables visualization of the exact position of suture ends over time.


Assuntos
Lentes Intraoculares , Técnicas de Sutura , Humanos , Implante de Lente Intraocular/métodos , Esclera/cirurgia , Suturas
4.
Semin Ophthalmol ; 37(1): 105-110, 2022 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-34057013

RESUMO

OBJECTIVES: To present and validate the novel grading system for objective classification of corectopia. SUBJECTS AND METHODS: We evaluated 28 eyes of 28 patients with or without corectopia and validated the grading and classification system for corectopia according to three major criteria: (i) direction, (ii) extent, and (iii) alteration of mydriasis. Intraclass correlation coefficient (ICC) and inter-rater agreement between 7 inexperienced and 1 experienced ophthalmologist against a golden standard (GS) were calculated. RESULTS: The ICC for the 7 inexperienced ophthalmologists regarding the grading of direction and centration of the pupil was 0.83 (95% confidence interval (CI), 0.74 to 0.90; p < .001) and 0.57 (95% CI, 0.43 to 0.72; p < .001), respectively. The inter-rater agreement was the same or almost the same in cases of pupil decentration between the inexperienced, experienced ophthalmologists and the GS (k = 0.82; 95% CI, 0.64-1.00; p < .001). In assessing the direction of pupil displacement, the inter-rater agreement was almost perfect between the inexperienced (k = 0.93; 95% CI, 0.84-1.00; p < .001) and experienced (k = 0.92; 95% CI: 0.82-1.02; p < .001) ophthalmologists and the GS. CONCLUSION: The first detailed clinical classification is proposed for objective corectopia grading particularly relevant in documenting and assessing progressive disease. It was confirmed to be acceptable for clinical use by inexperienced and experienced ophthalmologists alike.


Assuntos
Distúrbios Pupilares , Humanos , Variações Dependentes do Observador , Pupila , Reprodutibilidade dos Testes
5.
Digit J Ophthalmol ; 26(2): 7-16, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33867876

RESUMO

We report a case of late breakage of a 9-0 polypropylene transscleral suture used for fixation of a dislocated capsular bag-intraocular lens-modified capsular tension ring complex in a 52-year-old woman with Marfan syndrome. Breakage occurred despite use of a cow-hitch technique for external and internal fixation. We believe breakage was caused by the suture chafing on the sharp edges of the modified capsular tension ring eyelet. Cross-sectional analysis of Malyugin-modified capsular tension rings from two different manufacturers revealed a difference with respect to radius of curvature. Suturing intraocular implants with relatively sharp edges may cause suture breakage; further studies are needed to identify the critical parameters for the surface quality of sutured intraocular implants.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Lentes Intraoculares/efeitos adversos , Polipropilenos , Complicações Pós-Operatórias , Esclera/cirurgia , Técnicas de Sutura/efeitos adversos , Suturas/efeitos adversos , Migração do Implante de Lente Intraocular/cirurgia , Falha de Equipamento , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Reoperação/métodos , Fatores de Tempo
6.
J Cataract Refract Surg ; 46(1): 55-62, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-32050233

RESUMO

PURPOSE: To confirm the presence of incomplete vitreolenticular adhesion via microscope-integrated intraoperative optical coherence tomography (iOCT) during cataract surgery and via diagnostic spectral-domain OCT (SD-OCT) postoperatively. SETTING: S. Fyodorov Eye Microsurgery Complex State Institution, Moscow, Russia. DESIGN: Prospective noninterventional single-center study. METHODS: Clinical characteristics and surgical videos of 27 patients (28 eyes) who had cataract surgery were documented. Real-time iOCT integrated into the surgical microscope was directed to view the retrolenticular anatomy at the end of the surgery. Postoperatively, SD-OCT was also performed. RESULTS: This study comprised 28 eyes of 27 patients. Berger space was identified in 21 cases (75%) intraoperatively via iOCT and in 23 cases (82%) postoperatively via stationary OCT. Depth dimensions varied from 33.5 ± 87.0 µm to 383.1 ± 226.3 µm. Hyperreflective dots and particles of different shapes and sizes were documented within Berger space in 16 cases (57%) intraoperatively and in 9 cases (32%) postoperatively. Capsular rupture occurred in 1 case due to excessive posterior capsular movement anteriorly. The posterior capsular rupture was converted into a posterior capsulorhexis, leaving the anterior hyaloid membrane intact. CONCLUSIONS: iOCT confirmed the penetration of crystalline lens microfragments, cellular material, or medical suspension (triamcinolone) into the space between the posterior lens capsule and the anterior hyaloid membrane. This occurs due to discontinuity of both lenticular zonules and Wieger ligament attachment. A Wieger ligament rupture can also allow excessive Berger space hydration during phacoemulsification leading to anterior displacement of the posterior lens capsule increasing the risk of instrument touch and posterior capsule rupture.


Assuntos
Complicações Intraoperatórias/epidemiologia , Facoemulsificação , Descolamento do Vítreo/complicações , Segmento Anterior do Olho , Capsulorrexe , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Capsulotomia Posterior , Estudos Prospectivos , Fatores de Risco , Tomografia de Coerência Óptica , Gravação em Vídeo , Viscossuplementos
7.
J Cataract Refract Surg ; 34(7): 1114-20, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18571078

RESUMO

PURPOSE: To establish the safety of an intracameral injection of self-preserved moxifloxacin at the conclusion of routine cataract surgery for the prophylaxis of endophthalmitis and to assess the effect on macular thickness using optical coherence tomography (OCT). SETTING: Private practice, Bettendorf, Iowa, USA. METHODS: A retrospective review of the charts of consecutive cataract procedures was conducted to compare outcome measures in patients with or without intracameral injection of moxifloxacin that was diluted to a 0.1% solution in a 100 microg/0.1 mL dose at the conclusion of cataract surgery. In addition, in a prospective manner, macular thickness was measured by OCT in 31 eyes before and 6 weeks after cataract surgery in patients who received the intracameral injection. RESULTS: Aqueous cell counts 1 day postoperatively were significantly lower in the moxifloxacin-treated group (P=.0007). At 1 week, there was no difference between the 2 treatment groups in the number of patients who had no or trace cells. No stromal edema was observed in the moxifloxacin-treated group. Optical coherence tomography studies showed mean increases of less than 3% in macular thickness in all sectors and less than 4% in macular volume at all locations. No drug-related adverse effects were reported. CONCLUSION: No untoward effects were observed after intracameral injection of moxifloxacin 0.5% ophthalmic solution diluted to a 0.1% concentration at the conclusion of routine cataract surgery.


Assuntos
Anti-Infecciosos/uso terapêutico , Antibioticoprofilaxia , Compostos Aza/uso terapêutico , Extração de Catarata , Endoftalmite/prevenção & controle , Infecções Oculares Bacterianas/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Quinolinas/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos/efeitos adversos , Compostos Aza/efeitos adversos , Endoftalmite/microbiologia , Infecções Oculares Bacterianas/microbiologia , Feminino , Fluoroquinolonas , Humanos , Injeções , Implante de Lente Intraocular , Macula Lutea/efeitos dos fármacos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Moxifloxacina , Complicações Pós-Operatórias/microbiologia , Estudos Prospectivos , Quinolinas/efeitos adversos , Estudos Retrospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
8.
J Cataract Refract Surg ; 44(3): 262-265, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29605281

RESUMO

We describe a new approach for cataract surgery in ectopia lentis associated with an inadequately dilated pupil. A Malyugin ring 2.0 is first positioned in the eye to expand the pupil. One of the ring coils is then temporarily sutured to the limbal area with 10-0 polypropylene. With this maneuver, the pupillary expansion ring is placed in alignment with the center of the ectopic lens. Femtosecond laser anterior capsulotomy and lens fragmentation is then performed. Next, the temporary suture is released, a capsular hook(s) is placed to support the lens, and the lens is emulsified. A modified capsular tension ring is then inserted and sutured to the ciliary sulcus to center the capsular bag and the intraocular lens is implanted. This new technique for patients with insufficiently dilated pupils associated with ectopia lentis has the potential to improve surgical results and minimize complications in selected cases.


Assuntos
Ectopia do Cristalino/cirurgia , Terapia a Laser/métodos , Implante de Lente Intraocular , Facoemulsificação/métodos , Pupila/fisiologia , Cápsula Anterior do Cristalino/cirurgia , Tamponamento Interno , Síndrome de Exfoliação/complicações , Feminino , Humanos , Pressão Intraocular/fisiologia , Iris/fisiologia , Síndrome de Marfan/complicações , Pessoa de Meia-Idade , Técnicas de Sutura , Dispositivos para Expansão de Tecidos , Acuidade Visual/fisiologia
9.
J Refract Surg ; 34(10): 646-652, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30296325

RESUMO

PURPOSE: To compare the concentrations of interleukin (IL) (IL-1b, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12p70), interferon (IFN)-γ, tumor necrosis factor (TNF)-α, and TNF-ß in the aqueous humor of patients undergoing femtosecond laser-assisted cataract surgery (FLACS) and corneal mechanical paracentesis treated with two different topical nonsteroidal anti-inflammatory drugs (NSAIDs): bromfenac and indomethacin. METHODS: In this prospective, randomized controlled, single-center study, aqueous humor samples were obtained immediately after performing the femtosecond laser procedure or at the start of conventional phacoemulsification. Preoperatively, the FLACS groups were administered (once daily and four times daily, respectively) either topical bromfenac 0.09% (12 eyes) or indomethacin 0.1% (12 eyes). The corneal paracentesis bromfenac and indomethacin groups received the same regimen of instillation of NSAIDs, respectively. Quantitative analysis of the expressed cytokines in the aqueous humor was performed using FlowCytomix FC 500 Pro 3.0 Software (Bender MedSystems GmbH, Vienna, Austria). RESULTS: The intraoperative pupil diameter was correlated with the expression of IL-6 after the femtosecond laser procedure in the FLACS indomethacin group (r = -0.53; P = .07). A significant difference in mean pupillary size was detected between the FLACS bromfenac and indomethacin groups at the aspiration/irrigation time point (0.53 ± 0.26 mm) and at the end of surgery (0.68 ± 0.37 mm). Progressive pupillary constriction was observed in the indomethacin and bromfenac groups. CONCLUSIONS: A smaller expression of IL-6 to the overall cytokine network value was observed in cases receiving preoperative bromfenac 0.09%, explaining improved maintenance of intraoperative mydriasis. [J Refract Surg. 2018;34(10):646-652.].


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Humor Aquoso/metabolismo , Citocinas/metabolismo , Terapia a Laser , Facoemulsificação , Pupila/efeitos dos fármacos , Administração Oftálmica , Idoso , Benzofenonas/administração & dosagem , Bromobenzenos/administração & dosagem , Extração de Catarata/métodos , Feminino , Humanos , Indometacina/administração & dosagem , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas/administração & dosagem , Estudos Prospectivos
10.
Digit J Ophthalmol ; 23(2): 43-44, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28924422

RESUMO

We describe a case of femtosecond laser-assisted cataract surgery (FLACS) in an eye with multiple comorbidities, including retinal detachment surgery, high myopia, posterior chamber phakic intraocular lens (PC pIOL) and residual, emulsified, silicone oil located in the anterior chamber. FLACS was affected by the optical blockage, but the incomplete capsular tear was recoverable. The case suggests that silicone oil bubbles concentrated at the dome of the posterior corneal surface, along with the PC pIOL optic edges and scars after corneal astigmatic relaxing incisions can lead to incomplete anterior capsulotomy.


Assuntos
Extração de Catarata/métodos , Terapia a Laser/métodos , Lentes Intraoculares Fácicas , Adulto , Humanos , Masculino , Descolamento Retiniano/cirurgia , Óleos de Silicone/administração & dosagem , Resultado do Tratamento , Vitrectomia
11.
J Refract Surg ; 33(9): 646-648, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28880341

RESUMO

PURPOSE: To describe a case of femtosecond laser-assisted hydrophobic intraocular lens transection. METHODS: Case report. RESULTS: Femtosecond laser-assisted transection of a one-piece acrylic hydrophobic intraocular lens for explantation via a small surgical incision was successfully performed with low energy parameters. CONCLUSIONS: This case illustrates a novel and effective clinical application of the femtosecond laser. [J Refract Surg. 2017;33(9):646-648.].


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Extração de Catarata/efeitos adversos , Remoção de Dispositivo/métodos , Terapia a Laser/métodos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Refração Ocular , Adulto , Cápsula Anterior do Cristalino/diagnóstico por imagem , Extração de Catarata/métodos , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia de Coerência Óptica
12.
Ophthalmol Clin North Am ; 19(4): 495-506, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17067904

RESUMO

The intraoperative management of complication during cataract surgery of vitreous loss and dropped nucleus strongly influences the outcome, and a well-rehearsed plan for both staff and surgeons is needed. Preventative measures, early recognition, damage control, and resolution are discussed in this article. Maintenance of appropriate pressure relationships and tissue planes limits vitreous prolapse and the surgeon's primary goal is to avoid vitreous traction resulting in retinal tears and detachment. A pars plana approach to anterior vitrectomy with staining of the prolapsed vitreous is the most effective technique. Although residual lens material should be removed from the anterior and posterior chambers, once a fragment is lost to the posterior segment, the authors advocate referral for a standard three-port posterior vitrectomy with fragmenter as needed because the goal of the cataract surgeon is to offer the patient a clean, pseudophakic anterior segment and the best chance for an optimal visual recovery.


Assuntos
Extração de Catarata/efeitos adversos , Cristalino/cirurgia , Retina/lesões , Doenças Retinianas/cirurgia , Triancinolona Acetonida/uso terapêutico , Vitrectomia/métodos , Corpo Vítreo/lesões , Glucocorticoides/administração & dosagem , Glucocorticoides/uso terapêutico , Humanos , Injeções , Complicações Intraoperatórias , Prognóstico , Doenças Retinianas/tratamento farmacológico , Doenças Retinianas/etiologia , Triancinolona Acetonida/administração & dosagem
13.
J Cataract Refract Surg ; 42(8): 1112-8, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27531285

RESUMO

UNLABELLED: We developed a surgical technique that combines use of an iris hook and a pupil expansion ring in femtosecond laser-assisted cataract surgery complicated by insufficient mydriasis and an ectopic pupil. With this technique, the surgery, including femtosecond laser assistance, phacoemulsification, and intraocular lens implantation, can be accomplished successfully prior to iris repair. FINANCIAL DISCLOSURE: Dr. Malyugin receives travel grants from Alcon Laboratories, Inc. and Novartis Corp.; he receives royalties from Microsurgical Technology, Inc. None of the other authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Catarata , Implante de Lente Intraocular , Facoemulsificação , Pupila , Humanos , Midríase , Distúrbios Pupilares
14.
J Cataract Refract Surg ; 31(12): 2423-4, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16473241

RESUMO

This is the first report of a case of intraocular metallic foreign bodies retained after phacoemulsification in which the source was identified as silver emanating from the brazing of the irrigation tube as it entered the handpiece shell on its inner diameter. Although silver is considered to be inert in the eye and nonmagnetic, manufacturers should evaluate alternate methods of phacoemulsification handpiece design.


Assuntos
Corpos Estranhos no Olho/etiologia , Facoemulsificação/efeitos adversos , Prata , Idoso , Drenagem/métodos , Corpos Estranhos no Olho/cirurgia , Humanos , Masculino , Facoemulsificação/instrumentação , Irrigação Terapêutica/métodos
15.
J Cataract Refract Surg ; 41(9): 1845-54, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26603393

RESUMO

PURPOSE: To compare patient satisfaction, visual function, and spectacle independence in patients with crossed or conventional pseudophakic monovision. SETTING: Department of Ophthalmology, Henry Ford Health System, Taylor, Michigan, USA. DESIGN: Retrospective comparative cohort study. METHODS: Cataract surgery patient records from June 1999 to December 2013 were reviewed. Crossed monovision patients were identified. Control conventional monovision cases were matched for age, sex, general health, personal lifestyle/main hobbies, preoperative refractive status, postoperative refractive status, uncorrected distance visual acuity, uncorrected near visual acuity, astigmatism level, and anisometropia level. A survey was mailed to participants, and results were independently analyzed. RESULTS: The review comprised 7311 patient records. Forty-four crossed monovision patients were identified, and 30 of them were enrolled. Thirty matched pairs were surveyed. The mean anisometropia was 1.19 diopters (D) in the conventional and 1.12 D in the crossed monovision groups. No significant difference was identified for eye-hand coordination, eye-foot coordination, or sport-related depth perception, but satisfaction was slightly better in the crossed monovision group (P = .028). No significant difference was identified for 6 of 8 spectacle independence measures, but nighttime driving was a little easier for the crossed monovision group (P = .025). Seventy-seven percent of crossed and 50% of conventional monovision patients did not use glasses for intermediate distance activities (P = .037). CONCLUSION: Crossed pseudophakic monovision appears to work as well as conventional pseudophakic monovision in terms of patient satisfaction and spectacle independence in patients with a mild degree of anisometropic pseudophakia. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Óculos , Implante de Lente Intraocular , Satisfação do Paciente/estatística & dados numéricos , Facoemulsificação , Pseudofacia/fisiopatologia , Visão Monocular/fisiologia , Acuidade Visual/fisiologia , Idoso , Topografia da Córnea , Dominância Ocular , Óculos/estatística & dados numéricos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Inquéritos e Questionários
17.
J Cataract Refract Surg ; 44(11): 1400-1401, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30368352
18.
J Cataract Refract Surg ; 39(12): 1796-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24427792

RESUMO

We describe a capsulotomy technique to maintain the anterior chamber and pull the capsule disk gently centrally to separate the free edge from the surrounding peripheral capsule and to confirm there is a continuous 360-degree cut with a free disk.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Terapia a Laser/métodos , Capsulorrexe/métodos , Humanos , Retalhos Cirúrgicos , Tomografia de Coerência Óptica
19.
J Cataract Refract Surg ; 43(5): 705-706, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28602341
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA