Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Clin Radiol ; 79(10): 791-798, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39068113

RESUMO

AIM: To evaluate the impact of a new, less-invasive micro-computed tomography (CT) service on autopsy service provision. We recorded parental consent, type of autopsy performed, autopsy reporting times and time taken for the body to be released from the mortuary. MATERIALS AND METHODS: A retrospective, single-centre case series was conducted for all perinatal deaths since the introduction of our micro-CT service in 2016, with a detailed review of records extracted from 2019 and 2021. Fetal demographics (gestational age, weight), type of autopsy conducted, and the time taken from receiving the body to releasing the body and issuing a final report were recorded. RESULTS: Micro-CT imaging uptake increased to over two hundred cases/year by 2021. Overall, invasive autopsies reduced from (45.8%, 196/428; 2019) to (32.1%, 125/390; 2021) with an equivalent rise in less-invasive autopsy from 54.2% (232/428;2019) to 67.9% (265/390;2019). Offering a micro-CT service resulted in an increase in consent to imaging-based autopsies from (76.9%, 329/428;2019) to (87.2%, 340/390;2021). Micro-CT has become the most common post-mortem imaging performed in our institution at 54.4% (212/251;2021), although the body preparation time from the tissue staining required has increased the time to provide an autopsy report to 17 days and release of the body to 18 days. CONCLUSION: Our study shows that introducing a micro-CT post-mortem imaging service was associated with reduced use of conventional invasive procedures, despite a slight increase in turnaround times. Understanding these factors and continued improvements in micro-CT service delivery will help make this accessible to a wider population in the future.


Assuntos
Autopsia , Microtomografia por Raio-X , Humanos , Autopsia/métodos , Estudos Retrospectivos , Microtomografia por Raio-X/métodos , Feminino , Feto/diagnóstico por imagem , Gravidez
2.
Clin Radiol ; 78(11): 839-847, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37827594

RESUMO

Post-mortem computed tomography (PMCT) imaging is gaining popularity and acceptance for use alongside forensic autopsies of children, predominantly to aid in the detection of traumatic injuries. Recent research on this topic has provided a breadth of new information regarding the appropriate usage, imaging guidance, and diagnostic accuracy for the identification of different paediatric pathologies. Additionally, advanced CT imaging techniques, such as PMCT angiography or ventilated PMCT, have been trialled, and post-mortem micro-CT is now being used in specialist centres for the assessment of subtle fractures in extracted bone specimens. Various image post-processing methods (e.g., three-dimensional printing from PMCT imaging data) are being used for the illustration of injuries in the medicolegal setting to a lay audience and provide another avenue for the future of forensic radiology research. In this review, the evidence-based principles and benefits of post-mortem imaging for forensic investigation in childhood deaths are presented, with a particular focus on PMCT and current practices. Variations in forensic imaging strategies around the world, published diagnostic accuracy rates, and expected normal post-mortem imaging findings are discussed, as well as potential future applications and research in this area.


Assuntos
Fraturas Ósseas , Humanos , Criança , Autopsia/métodos , Patologia Legal/métodos , Processamento de Imagem Assistida por Computador , Microtomografia por Raio-X
3.
Clin Radiol ; 77(4): 274-282, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35164928

RESUMO

Cinematic rendering (CR) is a novel post-processing technique similar to volume rendering (VR), which allows for a more photorealistic imaging reconstruction by using a complex light modelling algorithm, incorporating information from multiple light paths and predicted photon scattering patterns. Several recent publications relating to adult imaging have argued that CR gives a better "realism" and "expressiveness" experience over VR techniques. CR has also been shown to improve visualisation of musculoskeletal and vascular anatomy compared with conventional CT viewing, and may help non-radiologists to understand complex patient anatomy. In this review, we provide an overview of how CR could be used in paediatric musculoskeletal imaging, particularly in complex diagnoses, surgical planning, and patient consent processes. We present a direct comparison of VR and CR reconstructions across a range of congenital and acquired musculoskeletal pathologies, highlighting potential advantages and areas for further research.


Assuntos
Sistema Musculoesquelético , Adulto , Algoritmos , Criança , Humanos , Processamento de Imagem Assistida por Computador , Sistema Musculoesquelético/diagnóstico por imagem , Fótons , Tomografia Computadorizada por Raios X
4.
Clin Radiol ; 77(1): e40-e47, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34742547

RESUMO

AIM: To determine the added value of lateral limb radiographs in suspected physical abuse (SPA), particularly with regard to fracture detection and reporter confidence. METHODS AND MATERIALS: A 3-year (October 2017 to November 2020) retrospective study was conducted. Two blinded paediatric radiologists independently reviewed the appendicular radiographs for the presence of fractures, first by reviewing just the frontal projections, then both frontal and lateral radiographs. The additional yield of fractures and changes in reporting confidence scores were recorded. RESULTS: One hundred and thirty-eight skeletal surveys (29 live, 109 deceased children) were assessed, consisting of 16 appendicular fractures imaged in two projections (six wrist, five knee, five ankle). In the majority of cases (14/16) the fractures were already visible on the frontal view with only two fractures (one distal radius, one distal tibial) identified only by lateral projection on the blinded review. One fracture (distal tibia) was visible only on the frontal radiograph (not lateral view). The addition of lateral projection did not lead to overcalling of fractures in the remaining normal studies. Radiologist confidence scores showed an improvement with the addition of a lateral projection when a study was thought to be normal (p=0.001-0.003), but not when a fracture was identified (p>0.05). CONCLUSION: The addition of lateral radiographs improves reporting confidence in normal skeletal surveys, but only rarely helped to detect additional fractures given that most were visible on frontal projections. Larger multicentre studies of clinical practice are required to confirm these findings.


Assuntos
Maus-Tratos Infantis/diagnóstico , Fraturas Ósseas/diagnóstico por imagem , Radiografia/métodos , Osso e Ossos/diagnóstico por imagem , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
5.
Ultrasound Obstet Gynecol ; 57(3): 449-458, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32149428

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) for perinatal autopsy in the same patient cohort, and to determine whether PM-US can provide the same anatomical information as PM-MRI. METHODS: In this prospective, 5-year (July 2014-July 2019) single-center study, we performed 1.5-T PM-MRI and PM-US in an unselected cohort of perinatal deaths. The diagnostic accuracies of both modalities were calculated, using autopsy as the reference standard. As a secondary objective, the concordance rates between the two imaging modalities for the overall main diagnosis and for five anatomical regions (brain, spine, thorax, heart and abdomen) were calculated. RESULTS: During the study period, 136 cases underwent both PM-US and PM-MRI, of which 88 (64.7%) also underwent autopsy. There was no significant difference in the rates of concordance with autopsy between the two modalities for overall diagnosis (PM-US, 86.4% (95% CI, 77.7-92.0%) vs PM-MRI, 88.6% (95% CI, 80.3-93.7%)) or in the sensitivities and specificities for individual anatomical regions. There were more non-diagnostic PM-US than PM-MRI examinations for the brain (22.8% vs 3.7%) and heart (14.7% vs 5.1%). If an 'imaging-only' autopsy had been performed, PM-US would have achieved the same diagnosis as 1.5-T PM-MRI in 86.8% (95% CI, 80.0-91.5%) of cases, with the highest rates of agreement being for spine (99.3% (95% CI, 95.9-99.9%)) and cardiac (97.3% (95% CI, 92.4-99.1%)) findings and the lowest being for brain diagnoses (85.2% (95% CI, 76.9-90.8%)). CONCLUSION: Although there were fewer non-diagnostic cases using PM-MRI than for PM-US, the high concordance rate for overall diagnosis suggests that PM-US could be used for triaging cases when PM-MRI access is limited or unavailable. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Autopsia/métodos , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Morte Perinatal/etiologia , Ultrassonografia/estatística & dados numéricos , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
6.
Ultrasound Obstet Gynecol ; 55(5): 667-675, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31271478

RESUMO

OBJECTIVES: To determine the feasibility and tissue yield of a perinatal incisionless ultrasound-guided biopsy procedure, the INcisionless Targeted Core Tissue (INTACT) technique, in the context of minimally invasive autopsy. METHODS: Cases of perinatal death in which the parents consented for minimally invasive autopsy underwent postmortem magnetic resonance imaging and an INTACT biopsy procedure, defined as needle biopsy of organs via the umbilical cord, performed under ultrasound guidance. In each case, three cores of tissue were obtained from seven target organs (both lungs, both kidneys, heart, spleen and liver). Biopsy success was predefined as an adequate volume of the intended target organ for pathological analysis, as judged by a pathologist blinded to the case and biopsy procedure. RESULTS: Thirty fetuses underwent organ sampling. Mean gestational age was 30 weeks (range, 18-40 weeks) and mean delivery-to-biopsy interval was 12 days (range, 6-22 days). The overall biopsy success rate was 153/201 (76.1%) samples, with the success rates in individual organs being highest for the heart and lungs (93% and 91%, respectively) and lowest for the spleen (11%). Excluding splenic samples, the biopsy success rate was 150/173 (86.7%). Histological abnormalities were found in 4/201 (2%) samples, all of which occurred in the lungs and kidneys of a fetus with pulmonary hypoplasia and multicystic kidney disease. CONCLUSIONS: Incisionless ultrasound-guided organ biopsy using the INTACT procedure is feasible, with an overall biopsy success rate of over 75%. This novel technique offers the ideal combination of an imaging-led autopsy with organ sampling for parents who decline the conventional invasive approach. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Autopsia/métodos , Feto/diagnóstico por imagem , Biópsia Guiada por Imagem/métodos , Ultrassonografia Pré-Natal/métodos , Estudos de Viabilidade , Feminino , Feto/patologia , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Morte Perinatal/etiologia , Gravidez
7.
Clin Radiol ; 75(7): 561.e25-561.e34, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32252991

RESUMO

AIM: To determine whether the presence of internal calcifications on perinatal post-mortem skeletal surveys (PMSS) are associated with certain diagnoses of fetal loss. METHODS AND MATERIALS: A 6-month retrospective, single-centre, cohort study was conducted on PMSS performed for perinatal death assessment. One reader re-reviewed all PMSS images for the presence and location of internal calcifications, and noted whether these were included within the original radiology report. Findings at autopsy were then reviewed independently by a second researcher and cause of fetal loss or main diagnosis recorded. Chi-squared tests were conducted to identify differences between those with and without internal calcifications at PMSS. RESULTS: Two hundred and thirty perinatal deaths (mean gestational age 18 weeks; average 12-35 weeks) were included in the study, of which 42 (18.3%) demonstrated intra-abdominal calcifications, and 16/42 (38.1%) were mentioned in the radiology reports. Most calcifications were found to be within the lumen of the gastrointestinal tract, and in the left upper quadrant of the abdomen. There was no statistical difference between identifiable causes for fetal loss at autopsy in cases with and without calcification at PMSS (59.5% versus 58.5% respectively, p=0.904). Nevertheless, where calcification and a cause for fetal loss were found, the aetiology was more likely to be due a fetal rather than placental issue. CONCLUSION: The presence of internal calcifications on PMSS was not associated with an increased likelihood of explainable fetal loss or particular diagnosis at autopsy.


Assuntos
Calcinose/diagnóstico por imagem , Morte Fetal , Autopsia , Calcinose/embriologia , Diagnóstico , Feminino , Morte Fetal/etiologia , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética , Masculino , Radiografia , Estudos Retrospectivos , Microtomografia por Raio-X
8.
BJOG ; 126(6): 745-753, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30576088

RESUMO

OBJECTIVE: To investigate whether less invasive methods of autopsy would be acceptable to bereaved parents and likely to increase uptake. DESIGN: Mixed methods study. SETTING: Bereaved parents recruited prospectively across seven hospitals in England and retrospectively through four parent support organisations. SAMPLE: Eight hundred and fifty-nine surveys and 20 interviews with bereaved parents. METHODS: Cross-sectional survey and qualitative semi-structured telephone interviews. MAIN OUTCOME MEASURES: Likely uptake, preferences, factors impacting decision-making, views on different autopsy methods. RESULTS: Overall, 90.5% of participants indicated that they would consent to some form of less invasive autopsy [either minimally invasive autopsy (MIA), non-invasive autopsy (NIA) or both]; 53.8% would consent to standard autopsy, 74.3% to MIA and 77.3% to NIA. Regarding parental preferences, 45.5% preferred MIA, 30.8% preferred NIA and 14.3% preferred standard autopsy. Participants who indicated they would decline standard autopsy but would consent to a less invasive option were significantly more likely to have a lower educational level (odds ratio 0.49; 95% CI 0.35-0.70; P = 0.000062). Qualitative findings suggest that parents value NIA because of the lack of any incision and MIA is considered a good compromise as it enables tissue sampling while easing the parental burden associated with consenting to standard autopsy. CONCLUSION: Less invasive methods of autopsy are acceptable alternatives for bereaved parents, and if offered, are likely to increase uptake and improve parental experience. Further health economic, validation and implementation studies are now required to assess the viability of offering these in routine widespread clinical care. TWEETABLE ABSTRACT: Mixed methods UK study finds less invasive methods of autopsy are acceptable alternatives for bereaved parents, and if offered, are likely to increase uptake and improve parental experience.


Assuntos
Feto Abortado/patologia , Autopsia/métodos , Anormalidades Congênitas , Morte Fetal/etiologia , Pais/psicologia , Morte Perinatal/etiologia , Natimorto , Luto , Anormalidades Congênitas/diagnóstico , Anormalidades Congênitas/patologia , Aconselhamento/métodos , Estudos Transversais , Tomada de Decisões , Inglaterra , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Gravidez , Complicações na Gravidez/psicologia , Pesquisa Qualitativa , Natimorto/psicologia
9.
Ultrasound Obstet Gynecol ; 54(6): 791-799, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30644623

RESUMO

OBJECTIVE: To compare the diagnostic rate and accuracy of 3-Tesla (T) postmortem magnetic resonance imaging (PM-MRI) and postmortem ultrasound (PM-US) in an unselected fetal population. METHODS: We performed prospectively, in a blinded manner, 3-T PM-MRI and PM-US on 160 unselected fetuses at 13-41 weeks of gestation. All imaging was reported according to a prespecified template, for five anatomical regions: brain, thorax, heart, abdomen and spine. The rates of non-diagnostic results for PM-US and PM-MRI were compared and, for results that were diagnostic, we calculated sensitivity, specificity and concordance rates for each anatomical region, using conventional autopsy as the reference standard. RESULTS: 3-T PM-MRI performed significantly better than did PM-US overall and in particular for fetuses ≥ 20 weeks' gestation. Specifically, the non-diagnostic rates for PM-MRI vs PM-US were 4.4% vs 26.9% (7/160 vs 43/160; P < 0.001) for the brain, 5.2% vs 17.4% (8/155 vs 27/155; P < 0.001) for the thorax, 3.8% vs 30.6% (6/157 vs 48/157; P < 0.001) for the heart and 3.2% vs 23.6% (5/157 vs 37/157; P < 0.001) for the abdomen. For the spine, both techniques showed an equally low non-diagnostic rate. When both postmortem imaging techniques were diagnostic, they had similar accuracy, with no difference in sensitivity or specificity, and similar concordance with autopsy (PM-US, 79.5-96.5%; PM-MRI, 81.6-99.1%). CONCLUSIONS: PM-MRI performed significantly better than PM-US in this unselected population, due mainly to a lower non-diagnostic rate. PM-MRI should remain the first-line imaging investigation for perinatal autopsy, but PM-US could be considered if MRI is not available, albeit with a higher non-diagnostic rate. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Morte Fetal/etiologia , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos , Abdome/diagnóstico por imagem , Aborto Induzido/estatística & dados numéricos , Autopsia/estatística & dados numéricos , Autopsia/tendências , Bélgica/epidemiologia , Encéfalo/diagnóstico por imagem , Causas de Morte , Feminino , Feto/patologia , Idade Gestacional , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade , Coluna Vertebral/diagnóstico por imagem , Tórax/diagnóstico por imagem , Ultrassonografia/estatística & dados numéricos
10.
Ultrasound Obstet Gynecol ; 54(5): 661-669, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30620444

RESUMO

OBJECTIVE: Less invasive autopsy techniques in cases of fetal or infant death have good acceptability among parents, but the published sampling adequacy in needle biopsy studies is generally poor. Minimally Invasive Autopsy with Laparoscopically assisted sampling (MinImAL) has the potential to increase the diagnostic yield of less invasive autopsy by improving the quality and quantity of tissue samples obtained, whilst permitting visualization, extraction and examination of internal organs through a small incision. The aim of this study was to present the findings of our experience with the MinImAL procedure in cases of fetal, neonatal and pediatric death. METHODS: This was a retrospective analysis of 103 prospectively recruited unselected cases of fetal, neonatal or pediatric death that underwent the MinImAL procedure at a tertiary referral center over a 5-year period. Following preprocedure 1.5-T whole-body postmortem magnetic resonance imaging, MinImAL autopsy was performed. Procedure duration, sampling adequacy and cause of death were assessed. Chi-square analysis was used to compare the 'unexplained' rate of intrauterine deaths in the cohort with that in a previously published cohort of > 1000 cases of intrauterine death examined by standard autopsy. RESULTS: MinImAL autopsy was performed successfully in 97.8% (91/93) of the cases undergoing a complete procedure. There was a satisfactory rate of adequate histological sampling in most major organs; heart (100%, 91 cases), lung (100%, 91 cases), kidney (100%, 91 cases), liver (96.7%, 88 cases), spleen (94.5%, 86 cases), adrenal glands (89.0%, 81 cases), pancreas (82.4%, 75 cases) and thymus (56.0%, 51 cases). Procedure duration was similar to that of standard autopsy in a previously published cohort of intrauterine deaths. The unexplained rate in stillbirths and intrauterine fetal deaths that underwent MinImAL autopsy was not significantly different from that following standard autopsy. CONCLUSIONS: The MinImAL procedure provides good histological yield from major organs with minimal cosmetic damage and can be learned by an autopsy practitioner. The MinImAL procedure is an appropriate minimally invasive alternative for the investigation of perinatal and pediatric deaths in which consent to full autopsy is withheld, and may have applications in both high- and low/middle-income settings. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Laparoscopia/métodos , Adolescente , Causas de Morte , Criança , Pré-Escolar , Estudos de Viabilidade , Morte Fetal/etiologia , Humanos , Lactente , Morte do Lactente/etiologia , Recém-Nascido , Estudos Retrospectivos , Imagem Corporal Total
11.
Ultrasound Obstet Gynecol ; 53(2): 229-238, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-28782198

RESUMO

OBJECTIVE: To assess the diagnostic accuracy of postmortem ultrasound performed by operators blinded to prenatal findings and to invasive autopsy results in fetuses at different gestational ages and to investigate the effect of various parameters on its diagnostic success. METHODS: We performed postmortem two-dimensional ultrasound examination, blinded to clinical details, on 163 fetuses at 13-42 weeks' gestation. Logistic regression analysis was used to investigate the effect of: (i) gestational age at postmortem ultrasound, (ii) presence of maceration and (iii) mode of death, on whether the exam succeeded or failed to reach a diagnosis. In 123 cases in which invasive autopsy was available, the diagnostic accuracy of ultrasound in detecting major organ abnormalities was evaluated, using invasive autopsy as the gold standard. RESULTS: For the fetal brain, postmortem ultrasound exam was non-diagnostic in significantly more fetuses with maceration (39.5%; 17/43) vs those without maceration (20.0%; 24/120) (P = 0.013). For the fetal thorax, the exam was non-diagnostic in 34.1% (15/44) of fetuses < 20 weeks of gestation and in 10.9% (13/119) of fetuses ≥ 20 weeks (P < 0.001). For the heart and abdominal organs, there was no association between non-diagnostic postmortem ultrasound and the variables tested. For fetuses < 20 weeks, specificity of postmortem ultrasound examination was 83.3% for detection of anomalies of the brain, 68.6% for the thorax and 77.4% for the heart. For fetuses ≥ 20 weeks, sensitivity and specificity were, respectively, 61.9% and 74.2% for detection of anomalies of the brain, 29.5% and 87.0% for the thorax and 65.0% and 83.1% for the heart. For the fetal abdominal organs, sensitivity was 60.7% and specificity 75.8%, and postmortem ultrasound was particularly useful for detection of abnormalities of the kidneys, irrespective of gestational age. CONCLUSION: Although maceration may lead to failure of postmortem ultrasound examination in some cases, this technique achieves diagnostically acceptable levels of accuracy for fetal brain and abdominal organs, compared with conventional autopsy. It may therefore play a role as a first-line examination before other virtual autopsy techniques are indicated. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Autopsia/métodos , Morte Fetal/etiologia , Feto/diagnóstico por imagem , Ultrassonografia/métodos , Aborto Espontâneo/etiologia , Feminino , Idade Gestacional , Humanos , Gravidez , Estudos Prospectivos , Análise de Regressão , Sensibilidade e Especificidade , Método Simples-Cego
12.
Clin Radiol ; 74(9): 733.e11-733.e18, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31160039

RESUMO

AIM: To determine local departmental adherence to the paediatric post-mortem magnetic resonance imaging (MRI) protocols, using a customised automated computational approach. MATERIALS AND METHODS: A retrospective review of 460 whole-body post-mortem MRI examinations performed at Great Ormond Street Hospital for Children over a 5.5-year period was assessed for adherence to a full or abbreviated imaging sequence protocol. A simple computer program was developed to batch process DICOM (digital imaging and communications in medicine) files, extracting imaging sequence details, followed by natural language processing (NLP) of authorised reports to automate information extraction of diagnostic image quality. RESULTS: The program was able to extract study parameters from the entire dataset (approximately 80 GB of data) in a few hours, and retrieve information on diagnostic image quality using NLP with an overall diagnostic accuracy for data extraction of 96.7% (445/460, 95% confidence interval [CI]: 94.7-98%). The full imaging protocol was adhered to in 305/460 (66.3%) cases, and an abbreviated protocol in 140/460 (30.4%) cases. Overall, 423/460 (91.9%) of studies were of diagnostic quality. These included 298/305 (97.7%) of the full protocol, 111/140 (79.3%) of the abbreviated protocol. In only five cases were the examinations non-diagnostic for all body systems, all of whom weighed <100 g (24.7-72 g) and imaged using the abbreviated protocol. CONCLUSION: The present study demonstrated a successful application of an automated approach for data collection for audit and quality assessment purposes using paediatric post-mortem imaging as a specific example. Re-audit of these data following change implementation will be straightforward now that the automated workflow is clearly established.


Assuntos
Autopsia/métodos , Armazenamento e Recuperação da Informação , Imageamento por Ressonância Magnética , Automação , Criança , Pré-Escolar , Auditoria Clínica , Inglaterra , Feto , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Imagem Corporal Total , Fluxo de Trabalho
13.
Clin Radiol ; 74(7): 496-502, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31126587

RESUMO

One of the most challenging areas of radiological imaging in children is the diagnosis of physical abuse. There is a dearth of paediatric radiologists willing to act as expert witnesses, particularly in the family courts. There are a number of reasons why radiologists may not be interested or willing to put themselves forward to work as expert witnesses in this field. A group of imaging experts recently formed the "British Society of Paediatric Radiology (BSPR) Working Group on Imaging in Suspected Physical Abuse (SPA)". The group comprises radiologists and neuroradiologists with current or previous experience of providing expert witness reports to the court in cases of SPA. The group met in January 2019 to explore pragmatic solutions to the chronic inefficiencies in both medical and legal practices and the challenges that arise from working in a legal arena with different structures, goals, and assessment criteria. Key issues concerned organisational inefficiencies, variable support from National Health Service Trusts and the Royal College of Radiologists to conduct this work, and the risk/benefit of involvement. This work is important for the patient, parents, and society in general, and highly rewarding for clinical practitioners who are involved, but there are several issues with current practices that discourage active participation. With several members of the group either retired or close to retirement, the shortage of experts is becoming a pressing issue within the UK, which requires an engaged multidisciplinary group to come up with creative solutions. Here, the group provide a consensus opinion highlighting the current barriers and potential facilitators to increasing the number of radiologists willing to provide opinions to the court.


Assuntos
Maus-Tratos Infantis/legislação & jurisprudência , Prova Pericial/legislação & jurisprudência , Mão de Obra em Saúde , Pediatria/legislação & jurisprudência , Radiologistas/legislação & jurisprudência , Criança , Humanos , Sociedades Médicas , Reino Unido
14.
Neuropathol Appl Neurobiol ; 44(7): 663-672, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29533475

RESUMO

AIMS: To develop an expert consensus statement regarding appropriate clinical and forensic post mortem neurological imaging. METHODS: An expert panel of clinicians were recruited from registered members of the British Neuropathological Society (BNS) and the International Society of Forensic Radiology and Imaging (ISFRI) with post mortem expertise. Following a focus group meeting, 16 core statements were incorporated into an online modified Delphi survey and each panellist was asked to score their level of agreement. Following the first iteration, two statements that failed to reach consensus were modified and re-rated. Consensus was predefined as 75% agreement across responders. RESULTS: Seventeen experts joined the panel and 12 (70.6%) attended the focus group meeting; 14 (82%) completed both iterations of the survey. Consensus was reached for need of adequate clinical history, multidisciplinary discussion, establishment of special interest groups to discuss cases, gathering further evidence to inform imaging choices, establishment of methods for quality assessment in reporting standards and adequate funding for imaging services. The panel agreed that pathologists should be responsible for neuroimaging referrals, collating results of ancillary tests, and producing the final post mortem report. Areas requiring further discussion include the impact of double reporting, indications for neuroimaging and utilities of three-dimensional printing. CONCLUSION: The BNS/ISFRI statement represents current views of an expert panel of health professionals engaged in post-mortem neuroimaging. We hope this provides a working guideline for less experienced operators, stimulates discussion and highlights the most pressing clinical and research questions.


Assuntos
Autopsia/métodos , Encéfalo/diagnóstico por imagem , Neuroimagem , Encéfalo/patologia , Consenso , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
15.
BJOG ; 125(2): 172-181, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28190300

RESUMO

BACKGROUND: Postmortem examination is the single most useful investigation in providing information to parents about why their baby or child died. Despite this, uptake remains well below the recommended 75%. OBJECTIVE: To address the question 'what are the barriers and motivators to perinatal, prenatal and paediatric PM examination?' SEARCH STRATEGY: Key databases including Pubmed and CINAHL; Cochrane library, websites of relevant patient organisations, hand search of key journals, first and last authors and references. SELECTION CRITERIA: Peer-reviewed qualitative, quantitative or mixed methods research examining factors affecting uptake or decline of perinatal or paediatric postmortem examination. DATA COLLECTION AND ANALYSIS: Narrative synthesis; findings were compared across studies to examine interrelations. MAIN RESULTS: Seven major themes describing barriers to postmortem uptake were identified: dislike of invasiveness, practicalities of the procedure, organ retention issues, protective parenting, communication and understanding, religion and culture and professional or organisational barriers. Six major themes related to factors which facilitated parental consent were identified: desire for information, contributing to research, coping and well-being, respectful care, minimally invasive options, and policy and practice. There were a number of themes in the literature that reflected best practice. CONCLUSION: Findings highlight the need for better health professional education and the fact some concerns may be mitigated if less invasive methods of postmortem were routinely available. New consent packages and codes of practice may have a positive impact on perception of examination after death. The landscape is changing; further research is necessary to assess the impact on postmortem uptake rates. TWEETABLE ABSTRACT: Systematic review to explore the barriers and motivators to perinatal, prenatal and paediatric postmortem examination.


Assuntos
Autopsia/estatística & dados numéricos , Causas de Morte , Acessibilidade aos Serviços de Saúde , Natimorto , Feminino , Humanos , Gravidez
17.
Ultrasound Obstet Gynecol ; 50(1): 79-87, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27706859

RESUMO

OBJECTIVE: Diffusion-weighted magnetic resonance imaging (DWI) is a sensitive method for assessing brain maturation and detecting brain lesions, providing apparent diffusion coefficient (ADC) values as a measure of water diffusion. Abnormal ADC values are seen in ischemic brain lesions, such as those associated with acute or chronic hypoxia. The aim of this study was to assess whether ADC values in the fetal brain were different in fetuses with severe intrauterine growth restriction (IUGR) compared with normal controls. METHODS: Brain magnetic resonance imaging (MRI) with single-shot axial DWI (b = 0 and b = 700 s/mm2 ) was performed in 30 fetuses with severe IUGR (estimated fetal weight < 3rd centile with absent or reversed umbilical artery Doppler flow) and in 24 normal controls of similar gestational age. Brain morphology and biometry were analyzed. ADC values were measured in frontal and occipital white matter, centrum semiovale, thalami, cerebellar hemisphere and pons. Frontal-occipital and frontal-cerebellar ADC ratios were calculated, and values were compared between IUGR fetuses and controls. RESULTS: There was no difference in gestational age at MRI between IUGR and control fetuses (IUGR, 30.2 ± 1.6 weeks vs controls, 30.7 ± 1.4 weeks). Fetal brain morphology and signals were normal in all fetuses. Brain dimensions (supratentorial ± infratentorial) were decreased (Z-score, < -2) in 20 (66.7%) IUGR fetuses. Compared with controls, IUGR fetuses had significantly lower ADC values in frontal white matter (1.97 ± 0.23 vs 2.17 ± 0.22 × 10-3 mm2 /s; P < 0.0001), thalami (1.04 ± 0.15 vs 1.13 ± 0.10 ×10-3 mm2 /s; P = 0.0002), centrum semiovale (1.86 ± 0.22 vs 1.97 ± 0.23 ×10-3 mm2 /s; P = 0.01) and pons (0.85 ± 0.19 vs 0.94 ± 0.12 ×10-3 mm2 /s; P = 0.043). IUGR fetuses had a lower frontal-occipital ADC ratio than did normal fetuses (1.00 ± 0.11 vs 1.08 ± 0.05; P = 0.003). CONCLUSIONS: ADC values in IUGR fetuses were significantly lower than in normal controls in the frontal white matter, thalami, centrum semiovale and pons, suggesting abnormal maturation in these regions. However, the prognostic value of these ADC changes is still unknown. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Diagnóstico Pré-Natal , Adulto , Estudos de Casos e Controles , Imagem de Difusão por Ressonância Magnética , Feminino , Idade Gestacional , Humanos , Gravidez , Resultado da Gravidez , Estudos Retrospectivos
19.
Clin Radiol ; 72(12): 1025-1037, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28821323

RESUMO

Post-mortem magnetic resonance (PMMR) imaging is rapidly emerging as an alternative, "less invasive", and more widely accepted investigative approach for perinatal deaths in the UK. PMMR has a high diagnostic accuracy for congenital and acquired fetal neuropathological anomalies compared to conventional autopsy, and is particularly useful when autopsy is non-diagnostic. The main objectives of this review are to describe and illustrate the range of common normal and abnormal central nervous system (CNS) findings encountered during PMMR investigation. This article covers the standard PMMR sequences used at our institution, normal physiological post-mortem findings, and a range of abnormal developmental and acquired conditions. The abnormal findings include diseases ranging from neural tube defects, posterior fossa malformations, those of forebrain and commissural development as well as neoplastic, haemorrhagic, and infectious aetiologies. Neuropathological findings at conventional autopsy accompany many of the conditions we describe, allowing readers to better understand the underlying disease processes and imaging appearances.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neuroimagem , Encéfalo/anormalidades , Encéfalo/embriologia , Encéfalo/patologia , Diagnóstico , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Mudanças Depois da Morte
20.
Int J Legal Med ; 130(4): 1003-1010, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26846767

RESUMO

OBJECTIVES: The aim of this preliminary study is to evaluate whether pleural fluid accumulates following death in a predictable manner, in particular whether such collections are related to post-mortem interval. METHODS: Images acquired by post-mortem magnetic resonance imaging (PMMR) were both subjectively and objectively assessed for extent of pleural fluid accumulation. Total thoracic volume and pleural fluid volume were calculated using segmentation functions on OSIRIX software. The percentage of pleural fluid as a percentage of thoracic volume was calculated, to account for variation in subject size. The cause of death as per the final autopsy report and the interval from death to imaging were also recorded. RESULTS: Twelve perinatal deaths/stillbirths (mean gestation 38 weeks, range 24-48 weeks, male/female 5:7) and 11 childhood deaths (mean age 1 year, range 1 day-4 years, male/female 3:8) were assessed. The mean interval from death to imaging for all cases was 7.5 days (range 1-23 days). Pleural fluid was present in almost all cases, and the mean percentage pleural effusion as a proportion of thoracic volume was 3.3 % (range 0.2-9.5 %). There was a significant correlation between the post-mortem interval and the amount of pleural fluid in childhood deaths (p < 0.05) but no significant relationship for perinatal deaths. CONCLUSION: The accumulation of pleural fluid detectable on PMMR in children is related to post-mortem interval. If this holds for a larger population, it may therefore be a useful marker for estimating time of death. A similar relationship was not found for perinatal deaths and stillbirths, the reasons for which remain uncertain.


Assuntos
Imageamento por Ressonância Magnética , Derrame Pleural/diagnóstico por imagem , Mudanças Depois da Morte , Biomarcadores , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Natimorto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA