Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(18)2022 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-36146308

RESUMO

Efficient, adaptive, locomotor function is critically important for maintaining our health and independence, but falls-related injuries when walking are a significant risk factor, particularly for more vulnerable populations such as older people and post-stroke individuals. Tripping is the leading cause of falls, and the swing-phase event Minimum Foot Clearance (MFC) is recognised as the key biomechanical determinant of tripping probability. MFC is defined as the minimum swing foot clearance, which is seen approximately mid-swing, and it is routinely measured in gait biomechanics laboratories using precise, high-speed, camera-based 3D motion capture systems. For practical intervention strategies designed to predict, and possibly assist, swing foot trajectory to prevent tripping, identification of the MFC event is essential; however, no technique is currently available to determine MFC timing in real-life settings outside the laboratory. One strategy has been to use wearable sensors, such as Inertial Measurement Units (IMUs), but these data are limited to primarily providing only tri-axial linear acceleration and angular velocity. The aim of this study was to develop Machine Learning (ML) algorithms to predict MFC timing based on the preceding toe-off gait event. The ML algorithms were trained using 13 young adults' foot trajectory data recorded from an Optotrak 3D motion capture system. A Deep Learning configuration was developed based on a Recurrent Neural Network with a Long Short-Term Memory (LSTM) architecture and Huber loss-functions to minimise MFC-timing prediction error. We succeeded in predicting MFC timing from toe-off characteristics with a mean absolute error of 0.07 s. Although further algorithm training using population-specific inputs are needed. The ML algorithms designed here can be used for real-time actuation of wearable active devices to increase foot clearance at critical MFC and reduce devastating tripping falls. Further developments in ML-guided actuation for active exoskeletons could prove highly effective in developing technologies to reduce tripping-related falls across a range of gait impaired populations.


Assuntos
Aprendizado Profundo , Idoso , Fenômenos Biomecânicos , , Marcha , Humanos , Dedos do Pé , Caminhada , Adulto Jovem
2.
IEEE Trans Biomed Eng ; 63(6): 1239-47, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26485354

RESUMO

Changes in human body hydration leading to excess fluid losses or overload affects the body fluid's ability to provide the necessary support for healthy living. We propose a time-dependent circuit model of real-time human body hydration, which models the human body tissue as a signal transmission medium. The circuit model predicts the attenuation of a propagating electrical signal. Hydration rates are modeled by a time constant τ, which characterizes the individual specific metabolic function of the body part measured. We define a surrogate human body anthropometric parameter θ by the muscle-fat ratio and comparing it with the body mass index (BMI), we find theoretically, the rate of hydration varying from 1.73 dB/min, for high θ and low τ to 0.05 dB/min for low θ and high τ. We compare these theoretical values with empirical measurements and show that real-time changes in human body hydration can be observed by measuring signal attenuation. We took empirical measurements using a vector network analyzer and obtained different hydration rates for various BMI, ranging from 0.6 dB/min for 22.7 [Formula: see text] down to 0.04 dB/min for 41.2 [Formula: see text]. We conclude that the galvanic coupling circuit model can predict changes in the volume of the body fluid, which are essential in diagnosing and monitoring treatment of body fluid disorder. Individuals with high BMI would have higher time-dependent biological characteristic, lower metabolic rate, and lower rate of hydration.


Assuntos
Água Corporal/fisiologia , Condutividade Elétrica , Modelos Biológicos , Processamento de Sinais Assistido por Computador , Tecido Adiposo/fisiologia , Braço/fisiologia , Composição Corporal/fisiologia , Índice de Massa Corporal , Humanos , Músculo Esquelético/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA