Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta Oncol ; 61(1): 64-72, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34586938

RESUMO

BACKGROUND: Re-irradiation (reRT) is a promising technique for patients with localized recurrence in a previously irradiated area but presents major challenges. These include how to deal with anatomical change between two courses of radiotherapy and integration of radiobiology when summating original and re-irradiation doses. The Support Tool for Re-Irradiation Decisions guided by Radiobiology (STRIDeR) project aims to develop a software tool for use in a commercial treatment planning system to facilitate more informed reRT by accounting for anatomical changes and incorporating radiobiology. We evaluated three approaches to dose summation, incorporating anatomical change and radiobiology to differing extents. METHODS: In a cohort of 21 patients who previously received pelvic re-irradiation the following dose summation strategies were compared: (1) Rigid registration (RIR) and physical dose summation, to reflect the current clinical approach, (2) RIR and radiobiological dose summation in equivalent dose in 2 Gy fractions (EQD2), and (3) Patient-specific deformable image registration (DIR) with EQD2 dose summation. RESULTS: RIR and physical dose summation (Strategy 1) resulted in high cumulative organ at risk (OAR) doses being 'missed' in 14% of cases, which were highlighted by EQD2 dose summation (Strategy 2). DIR (with EQD2 dose summation; Strategy 3) resulted in improved OAR overlap and distance to agreement metrics compared to RIR (with EQD2 dose summation; Strategy 2) and was consistently preferred in terms of clinical utility. DIR was considered to have a clinically important impact on dose summation in 38% of cases. CONCLUSION: Re-irradiation cases require individualized assessment when considering dose summation with the previous treatment plan. Fractionation correction is necessary to meaningfully assess cumulative doses and reduce the risk of unintentional OAR overdose. DIR can add clinically relevant information in selected cases, especially for significant anatomical change. Robust solutions for cumulative dose assessment offer the potential for future improved understanding of cumulative OAR tolerances.


Assuntos
Reirradiação , Fracionamento da Dose de Radiação , Humanos , Pelve , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
2.
Radiother Oncol ; 182: 109545, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36813170

RESUMO

BACKGROUND: The STRIDeR (Support Tool for Re-Irradiation Decisions guided by Radiobiology) project aims to create a clinically viable re-irradiation planning pathway within a commercial treatment planning system (TPS). Such a pathway should account for previously delivered dose, voxel-by-voxel, taking fractionation effects, tissue recovery and anatomical changes into account. This work presents the workflow and technical solutions in the STRIDeR pathway. METHODS: The pathway was implemented in RayStation (version 9B DTK) to allow an original dose distribution to be used as background dose to guide optimisation of re-irradiation plans. Organ at risk (OAR) planning objectives in equivalent dose in 2 Gy fractions (EQD2) were applied cumulatively across the original and re-irradiation treatments, with optimisation of the re-irradiation plan performed voxel-by-voxel in EQD2. Different approaches to image registration were employed to account for anatomical change. Data from 21 patients who received pelvic Stereotactic Ablative Radiotherapy (SABR) re-irradiation were used to illustrate the use of the STRIDeR workflow. STRIDeR plans were compared to those produced using a standard manual method. RESULTS: The STRIDeR pathway resulted in clinically acceptable plans in 20/21 cases. Compared to plans produced using the laborious manual method, less constraint relaxation was required or higher re-irradiation doses could be prescribed in 3/21. CONCLUSION: The STRIDeR pathway used background dose to guide radiobiologically meaningful, anatomically-appropriate re-irradiation treatment planning within a commercial TPS. This provides a standardised and transparent approach, offering more informed re-irradiation and improved cumulative OAR dose evaluation.


Assuntos
Radioterapia de Intensidade Modulada , Reirradiação , Humanos , Dosagem Radioterapêutica , Reirradiação/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Fracionamento da Dose de Radiação , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA