Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
J Endovasc Ther ; : 15266028241255533, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38804508

RESUMO

PURPOSE: In some cases of endovascular thoracoabdominal or juxtarenal aortic aneurysm repair, a thoracic endograft in combination with a fenestrated renovisceral device may be needed in order to create a sufficient proximal landing zone. This study aimed to evaluate the technical aspects and postoperative morbidity of a single- or 2-stage approach. METHODS: Eighty-seven consecutive patients undergoing thoracic endovascular aortic repair (TEVAR) in combination with elective fenestrated repair (fenestrated endovascular aortic repair [FEVAR]; fenestrated Anaconda device) from 2015 to 2022 were included in this retrospective bicentric study. Underlying pathologies, aortic morphology, technical details, and postoperative morbidity were recorded. RESULTS: Single-staged ("1S," n=61) and 2-staged ("2S," n=26) interventions were compared. Indications were thoracoabdominal aneurysms (TAAAs) (Crawford I-IV) (n=56, 64%) and juxtarenal aneurysms (n=31, 36%). In 2S, the proportion of TAAA was higher than in 1S (2S: 77%, 1S: 59%; p=0.001). In 2S, the covered length of the descending aorta was longer (1S: 128±60 mm, 2S: 202±64 mm; p=0.003). Temporary aneurysm sack perfusion (TASP) was established in 11 (18%) of 1S and 1 (4%) of 2S patients (p=0.079), as well as cerebrospinal fluid (CSF) drainage catheter in 48 (79%) of 1S and 19 (73%) of 2S. The rate of spinal cord ischemia (SCI) and the severity of SCI were not different in both groups, with a total of 3 cases of persisting paraplegia. The rate of access complications was higher in 2S (n=6, 23%) than in 1S (n=4, 7%; p=0.027). Postoperative 30 day morbidity did not significantly differ in both groups and neither did 30 day mortality (4.6% in 1S vs 3.8% in 2S; p=0.083). CONCLUSION: The combination of TEVAR and FEVAR using a fenestrated endograft is feasible and safe. Aortic morphology does not change significantly after endovascular repair. A single-staged strategy is feasible with excellent results, especially in Crawford IV, Crawford V, or juxtarenal aneurysms. Two-staged repair is recommended in cases with long aortic coverage and a higher American Society of Anesthesiologists (ASA) class. Follow-up data are needed to evaluate the long-term stability of the TEVAR/FEVAR interconnection. CLINICAL IMPACT: Our study has revealed the safety and efficacy of the combination of TEVAR and FEVAR in the treatment of TAAAs and juxtarenal aneurysms with compromised supravisceral landing zones. A single-staged concept is not necessary in all cases. Staged procedures may reduce postoperative morbidity in cases with long aortic coverage and higher ASA class.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38857878

RESUMO

OBJECTIVE: The decision to convert from catheter to arteriovenous access is difficult yet very important. The ability to accurately predict fistula survival prior to surgery would significantly improve the decision making process. Many previously investigated demographic and clinical features have been associated with fistula failure. However, it is not conclusively understood how reliable predictions based on these parameters are at an individual level. The aim of this study was to investigate the probability of arteriovenous fistula maturation and survival after conversion using machine learning workflows. METHODS: A retrospective cohort study on multicentre data from a large North American dialysis organisation was conducted. The study population comprised 73 031 chronic in centre haemodialysis patients. The dataset included 49 variables including demographic and clinical features. Two distinct feature selection and prediction pipelines were used: LASSO regression and Boruta followed by a random forest classifier. Predictions were facilitated for re-conversion to catheter within one year. Additionally, all cause mortality predictions were conducted to serve as a comparator. RESULTS: In total, 38 151 patients (52.2%) had complete data and made up the main cohort. Sensitivity analyses were conducted in 67 421 patients (92.3%) after eliminating variables with a high proportion of missing data points. Selected features diverged between datasets and workflows. A previously failed arteriovenous access appeared to be the most stable predictor for subsequent failure. Prediction of re-conversion based on the demographic and clinical information resulted in an area under the receiver operating characteristic curve (ROCAUC) between 0.541 and 0.571, whereas models predicting all cause mortality performed considerably better (ROCAUC 0.662 - 0.683). CONCLUSION: While group level depiction of major adverse outcomes after catheter to arteriovenous fistula or graft conversion is possible using the included variables, patient level predictions are associated with limited performance. Factors during and after fistula creation as well as biomolecular and genetic biomarkers might be more relevant predictors of fistula survival than baseline clinical conditions.

3.
J Ultrasound Med ; 43(3): 429-437, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37972197

RESUMO

OBJECTIVES: Several imaging modalities have been suggested for surveillance after fenestrated endovascular aortic repair in general and endoleak detection in specific. In the present project a coded excitation-based ultrasound (B-Flow) was investigated for endoleak detection after complex endovascular aortic repair. METHODS: Patients post complex endovascular aortic repair (FEVAR or T/FEVAR) undergoing follow-up appointments including ultrasonography of the aorta at a vascular and endovascular surgery outpatient center were included in the study. B-Flow was compared with computed tomography angiography (CTA), Duplex ultrasound (DUS), and contrast-enhanced ultrasound (CEUS) regarding agreement and reliability for endoleak detection and characterization. RESULTS: In total, 47 follow-ups were included. They accumulated in a total of 149 imaging investigations. Endoleaks were discovered in 44.7% of B-Flow studies and a majority of these endoleaks were classified as type II. Agreement between B-Flow and other imaging modalities was good (>80.0%) in general. However, with B-Flow 6 and 2 endoleaks would have been missed compared with CEUS and CTA, respectively. Regarding endoleak classification, B-Flow had a strong agreement (94.5%) with CEUS in detected cases. Furthermore, in a limited subset analysis, imaging findings were externally validated using findings from angiography. CONCLUSIONS: Ultrasonography allows for endoleak detection and characterization without an invasive procedure or the use of potentially nephrotoxic contrast medium and can reduce radiation exposure. While CEUS mitigates issues of radiation and nephrotoxicity it still requires the intravenous application of contrast enhancers. Ultrasound coded-excitation imaging such as B-Flow could therefore further simplify endoleak surveillance after fenestrated endovascular aortic repair.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Meios de Contraste , Endoleak/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Reprodutibilidade dos Testes , Ultrassonografia , Resultado do Tratamento
4.
J Surg Res ; 289: 164-170, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37119618

RESUMO

INTRODUCTION: Acute kidney injury (AKI) is a common complication following endovascular aortic repair (EVAR). An association of AKI with patient survival after fenestrated EVAR (FEVAR) is currently under investigation. METHODS: Patients undergoing FEVAR between April 2013 and June 2020 were included in the study. AKI was defined according to acute kidney injury network criteria. Demographic and perioperative data, complications, and survival are reported for the study cohort. The data were analyzed to identify possible predictors of AKI. RESULTS: Two hundred and seventeen patients underwent FEVAR during the study period. Survival at last follow-up (20.4 ± 20.1 mo) was 75.1%. Thirty patients experienced AKI (13.8%). Six of 30 patients with AKI (20%) died within 30 days or in-hospital and 1 (3.3%) progressed to hemodialysis. Within 1 y, renal function had recovered in 23 patients (76.7%). In-hospital mortality was higher in patients with AKI (20% versus 4.3%, P = 0.006). A higher rate of AKI was seen in patients in whom an intraoperative technical complication had been documented (38.5% versus 8.4%, P = 0.001). CONCLUSIONS: Patients undergoing FEVAR are at risk of developing AKI, especially if they experience technical intraoperative complications. Most patients see recovery of renal function within the first 30 days to 1 y, but AKI remains associated with significantly increased in-hospital mortality.


Assuntos
Injúria Renal Aguda , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Abdominal/cirurgia , Fatores de Risco , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia
5.
J Endovasc Ther ; : 15266028231174113, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37154408

RESUMO

PURPOSE: Fenestrated endovascular aortic repair (FEVAR) is technically more challenging when performed after a failing EVAR procedure (FEVAR after EVAR). This study aims to assess the technical outcome of FEVAR after EVAR and to identify factors that may influence complication rates. METHODS: A retrospective observational study was conducted at a single department of vascular and endovascular surgery. The rate of FEVAR after EVAR compared to primary FEVAR is reported. Complication and primary unconnected fenestration (PUF) rates as well as survival were assessed for the FEVAR after EVAR cohort. PUF rates and operating time were also compared to all primary FEVAR patients. Patient characteristics and technical factors such as number of fenestrations or use of a steerable sheath were assessed as possible influencers on technical success when performing FEVAR after EVAR. RESULTS: Two hundred and nine fenestrated devices were implanted during the study period (2013 to April 2020). Thirty-five patients (16.7% of all FEVAR patients) had undergone FEVAR after EVAR and were included in the study. Overall survival at last follow-up (20.2±19.1 months) was 82.9% in FEVAR after EVAR patients. Rates of technical failure dropped significantly after 14 procedures (42.9% vs. 9.5%; p=0.03). Primary unconnected fenestrations were seen in 3 cases of FEVAR after EVAR (8.6%) and 14 of 174 primary FEVAR cases (8.0%; p>0.99). Operating time for FEVAR after EVAR was significantly higher than for primary FEVAR (301.1±110.5 minutes vs. 253.9±103.4 minutes; p=0.02). The availability of a steerable sheath was a significant predictor of reduced risk of PUFs, whereas age and gender, number of fenestrations or suprarenal fixation of the failed EVAR did not significantly influence PUF rates. CONCLUSION: Fewer technical complications were seen over the study period in FEVAR after EVAR patients. While rates of PUFs were not different from primary FEVAR, operating time was significantly longer in patients undergoing FEVAR for failed EVAR. Fenestrated EVAR can be a valuable and safe tool to treat patients with progression of aortic disease or type Ia endoleak after EVAR but may be more complex to achieve than primary FEVAR. CLINICAL IMPACT: This retrospective study assesses the technical outcome of fenestrated endovascular aortic repair (fenestrated EVAR; FEVAR) after prior EVAR. While rates of primary unconnected fenestrations were not different from primary FEVAR, operating time was significantly longer in patients undergoing FEVAR for failed EVAR. Fenestrated EVAR after prior EVAR may be technically more challenging than primary FEVAR procedures, but could be performed with equally good results in this patient cohort. FEVAR offers a feasible treatment option for patients with progression of aortic disease or type Ia endoleak after EVAR.

6.
J Vasc Surg ; 75(1): 99-108.e2, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34425192

RESUMO

OBJECTIVE: A crucial step in designing fenestrated stent grafts for treatment of complex aortic abdominal aneurysms is the accurate positioning of the fenestrations. The deployment of a fenestrated stent graft prototype in a patient-specific rigid aortic model can be used for design verification in vitro, but is time and human resources consuming. Numerical simulation (NS) of fenestrated stent graft deployment using the finite element analysis has recently been developed; the aim of this study was to compare the accuracy of fenestration positioning by NS and in vitro. METHODS: All consecutive cases of complex aortic abdominal aneurysm treated with the Fenestrated Anaconda (Terumo Aortic) in six European centers were included in a prospective, observational study. To compare fenestration positioning, the distance from the center of the fenestration to the proximal end of the stent graft (L) and the angular distance from the 0° position (C) were measured and compared between in vitro testing (L1, C1) and NS (L2, C2). The primary hypothesis was that ΔL (|L2 - L1|) and ΔC (|C2 - C1|) would be 2.5 or less mm in more than 80% of the cases. The duration of both processes was also compared. RESULTS: Between May 2018 and January 2019, 50 patients with complex aortic abdominal aneurysms received a fenestrated stent graft with a total of 176 fenestrations. The ΔL and ΔC was 2.5 mm or less for 173 (98%) and 174 (99%) fenestrations, respectively. The NS process duration was significantly shorter than the in vitro (2.1 days [range, 1.0-5.2 days] vs 20.6 days [range, 9-82 days]; P < .001). CONCLUSIONS: Positioning of fenestrations using NS is as accurate as in vitro and could significantly decrease delivery time of fenestrated stent grafts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Modelos Cardiovasculares , Complicações Pós-Operatórias/epidemiologia , Stents/efeitos adversos , Aorta Abdominal/anatomia & histologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Simulação por Computador , Humanos , Modelos Anatômicos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
7.
Ann Vasc Surg ; 66: 160-170, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31978487

RESUMO

BACKGROUND: Although recent data on the treatment of thoracoabdominal aortic aneurysms (TAAAs) are promising, in some cases, the paravisceral segment of the aorta may not be suitable for a branched endograft due to space restrictions. A combination of a fenestrated aneurysm repair (FEVAR) with a thoracic aneurysm repair (TEVAR) may represent a feasible treatment option. The current investigation was performed to assess the stability of a fenestrated Anaconda device implanted into a set of thoracic endografts from different manufacturers. We then assessed our clinical results with the FEVAR/TEVAR combination. METHODS: Pull-out forces were measured in vitro after docking a fenestrated Anaconda graft within the distal end of different TEVAR devices. Anaconda devices were implanted in 28- or 30-mm thoracic tube grafts (oversizing of at least 2 mm: 13.3-21.4; minimum overlap of 15 mm). Continuously increasing longitudinal pull forces of up to 100 N were applied on an Instron Tensile Tester. Initial break point and damage to the endografts were documented. Clinical results of patients treated with such an FEVAR/TEVAR combination at our institution are presented as a second part of this study. RESULTS: Median pull-out forces ranged from 2.38 N to 55.0 N. The highest stability was achieved with 34-mm Anaconda devices in 28-mm thoracic tube grafts. Grafts with either thinner Dacron material or those featuring a polytetrafluorethylene membrane seemed especially vulnerable to punctures and tears caused by the downward-looking hooks of the Anaconda device. Between April 1, 2013 and December 31, 2018, in 28 of 172 patients treated with a fenestrated Anaconda device, prior implantation of a thoracic tube graft was necessary to create a sufficient proximal landing zone. In 25 cases (89.3%), the aneurysm was successfully treated. Although the 30-day reintervention rate in this subgroup was relatively high at 28.6%, none of these was due to a failure of the FEVAR/TEVAR combination. Upon an average follow-up of 15 months, no failure of the graft connection and no type III endoleak due to membrane damage were observed. CONCLUSIONS: The combination of a thoracic tube graft and a fenestrated Anaconda device is a viable option for the treatment of patients with Extent I or IV TAAAs with no adequate landing zone above the celiac trunk. Although pull-out testing has shown good stability with most assessed grafts, the thoracic devices with thicker Dacron membranes seemed to be especially suitable.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Endoleak/etiologia , Endoleak/prevenção & controle , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Feminino , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Polietilenotereftalatos , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Estresse Mecânico , Resistência à Tração , Resultado do Tratamento
8.
J Vasc Surg ; 70(4): 1107-1114, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31147136

RESUMO

OBJECTIVE: Internal iliac artery aneurysm (IIAA) is a rare entity. Its treatment can be technically challenging. The aim of this study was to evaluate the treatment possibilities in an era of advanced endovascular techniques and their potential to preserve iliac blood flow while reliably excluding the aneurysm. METHODS: A retrospective analysis of 46 consecutive patients with endovascularly treated IIAA was performed. Data were collected from a single-institution aortoiliac database. The following end points were recorded: technique of aneurysm exclusion, technical success rates, perioperative morbidity and mortality, primary patency, and midterm follow-up. RESULTS: Between September 2009 and May 2016, a total of 46 patients with 55 IIAAs were identified. The majority of patients (n = 39 [84.8%]) had aortoiliac aneurysms and seven had isolated IIAAs (15.2%). The following surgical techniques were used: implantation of iliac branch devices (IBDs; n = 29), occlusion of the internal iliac artery (IIA) by ostium coverage with or without prior coil embolization (n = 23), and other endovascular techniques (n = 3). Primary assisted technical success was achieved in 93.1% of IBD implantations and in 100% of occlusions by ostium coverage and other techniques. Overall 30-day mortality was 4.3% (n = 2) and 0% in electively treated patients. Assisted midterm patency after IBD implantation was 93.1%. Gluteal claudication occurred in seven patients (15.2%) who had undergone intentional or accidental occlusion of the IIA or the superior gluteal artery. Reintervention rates within the midterm follow-up were 13.8% (n = 4) after IBD implantation and 4.3% (n = 1) after coverage of the IIA ostium. No ruptures were observed during follow-up, and no complications occurred during reinterventions. CONCLUSIONS: Implantation of IBD devices for the treatment of hypogastric artery aneurysms shows good technical results with a high primary patency and a low rate of perioperative complications. Although successful aneurysm exclusion while preserving pelvic blood flow is associated with a higher rate of reinterventions during midterm follow-up, it should be taken into consideration, especially in complex endovascular aortoiliac aneurysm repair.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Embolização Terapêutica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
10.
Eur J Vasc Endovasc Surg ; 58(6): 831-838, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31615695

RESUMO

OBJECTIVES: At 12 months follow up of the PLIANT study, clinical success and efficacy of the E-liac Stent Graft System (JOTEC GmbH, Hechingen, Germany) were evaluated. Clinical success was defined as aneurysm exclusion (no type I, III, IV endoleak) with primary patency of the internal iliac artery (IIA) and external iliac artery (EIA) on the E-liac implantation side. METHODS: In this prospective multicentre European observational study, clinical and morphological data of 45 patients (93% male, mean age 72 y) were prospectively collected in 11 European centres between July 2014 and June 2016. Forty patients underwent an aorto-iliac (three patients bilaterally) treatment and five an isolated iliac treatment. RESULTS: At 12 months follow up, data were available for 42 patients. Overall clinical success at 12 months was 90%, with a survival rate of 100%. Four patients (10%) did not achieve clinical success, one with an internal iliac artery (IIA) occlusion on the E-liac implantation side, one with an infrarenal type Ia endoleak, and two with type Ib endoleaks in IIA. At 12 months the primary patency rate in the internal iliac artery on the iliac side branch implantation side was 98%. Two patients (5%) received E-liac related re-interventions: one caused by an edge stenosis at the distal end of the graft limb in the external iliac artery (EIA) and one caused by thrombo-embolism in the external iliac artery. Thus, for the EIA, primary and secondary patency rates were 98% and 100%, respectively. CONCLUSIONS: The low device related re-intervention rate of 5%, the high survival rate of 100%, and the high primary patency rates of 98% for the IIA and EIA at 12 month follow up demonstrate the safety and efficacy of the E-liac Stent Graft System. Long term 36 month results are awaited to confirm the efficacy and durability.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Endoleak/epidemiologia , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/epidemiologia , Aneurisma Ilíaco/cirurgia , Stents Metálicos Autoexpansíveis/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/estatística & dados numéricos , Resultado do Tratamento
11.
Vascular ; 27(1): 46-50, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30205778

RESUMO

OBJECTIVE: Custom-made fenestrated aortic endografts allow exclusion of pararenal aortic aneurysms while maintaining blood flow to aortic branches. Meticulous device planning and precise deployment of the main body are essential to allow successful cannulation of the fenestrations. This study investigates whether a learning curve can be observed with more reliable cannulation and connection of fenestrations over time at a single department of vascular and endovascular surgery with multiple surgeons trained to use the device. METHODS: A retrospective analysis of data from all patients undergoing primary fenestrated endovascular aneurysm repair during the study period was performed. Outcome measures included case volume and average number of fenestrations over time, average fluoroscopy dose area product per calendar year and primary unconnected fenestration and 30-day mortality rates. RESULTS: Between 1 January 2013 and 31 December 2016, 89 patients with no history of endovascular aneurysm repair underwent fenestrated endovascular aneurysm repair at our institution. The number of fenestrations per case increased over time, averaging 2.6 in 2013 and 3.3 in 2016. Primary unconnected fenestration and 30-day mortality rates were 5.6%. Primary-assisted technical success was 93.3%, secondary-assisted technical success was 94.4%. Fluoroscopy dose area product declined over the study period. Thirty-day mortality and primary unconnected fenestration rates did not significantly change over the study period. CONCLUSION: Albeit the reduction in lethal complications and primary technical success rates were not statistically significant, a lower percentage of unconnected fenestrations and 30-day mortality per calendar year were observed over time. At the same time, an increasing complexity of performed cases, as reflected by an increasing number of fenestrations per case, was observed. Complications associated with this complex endovascular procedure are potentially lethal and remain an unfortunate reality and may not be entirely dependent on overcoming a learning curve. A higher volume of cases performed over the study period and a reduction in fluoroscopy use can be considered a representation of the institutional development and learning curve for the Anaconda fenestrated endograft at a department with prior complex endovascular aortic repair experience, but due to limitations of the current retrospective observation, deserve further consideration in future trials, ideally designed in a prospective fashion.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Competência Clínica , Procedimentos Endovasculares/instrumentação , Curva de Aprendizado , Desenho de Prótese , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
J Stroke Cerebrovasc Dis ; 28(6): 1540-1545, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30952532

RESUMO

BACKGROUND: Stroke is one of the leading causes of morbidity and mortality. Thromboembolism, as a major cause of carotid artery-related stroke, can be caused by plaque rupture which is associated with neoangiogenesis within the carotid plaque. AIM: We sought to investigate a possible correlation between angiogenesis-related factors and preoperative neurological manifestations in patients with internal carotid artery stenosis, for a better understanding of thromboembolism in internal carotid artery stenosis-related stroke. METHODS: This study included 54 patients (asymptomatic, n = 20 and symptomatic, n = 34) undergoing carotid endarterectomy for high-grade internal carotid artery stenosis. In the retrieved carotid plaques, angiogenesis-related factors (vascular endothelial growth factor [VEGF], hypoxia inducible factor-1 alpha [HIF-1α], and Clusterin) were measured by immunohistochemistry and quantified by real-time polymerase chain reaction. RESULTS: We demonstrated the expression of VEGF, HIF-1α, and Clusterin by endothelial cells and smooth muscle cells in the carotid plaques. Noteworthy, mRNA VEGF levels were .7-fold higher in symptomatic patients (P = .017) compared to asymptomatic patients. In contrast, mRNA Clusterin levels were 1.8-fold lower (P = .021). Levels of mRNA HIF-1α were 1.5-fold higher in asymptomatic patients, but no statistical significance was reached between the 2 groups. CONCLUSIONS: Our results show an association between VEGF and Clusterin and neurological symptoms of patients with high-grade carotid artery stenosis.


Assuntos
Artéria Carótida Interna/química , Estenose das Carótidas/metabolismo , Clusterina/análise , Subunidade alfa do Fator 1 Induzível por Hipóxia/análise , Placa Aterosclerótica , Fator A de Crescimento do Endotélio Vascular/análise , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Artéria Carótida Interna/patologia , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/complicações , Estenose das Carótidas/patologia , Estenose das Carótidas/cirurgia , Clusterina/genética , Feminino , Regulação da Expressão Gênica , Humanos , Subunidade alfa do Fator 1 Induzível por Hipóxia/genética , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica , Estudos Prospectivos , RNA Mensageiro/genética , Ruptura Espontânea , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Fator A de Crescimento do Endotélio Vascular/genética
13.
J Vasc Surg ; 68(2): 384-391, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29526378

RESUMO

OBJECTIVE: Because of its minimally invasive nature, percutaneous femoral access for endovascular aneurysm repair (pEVAR) is currently undergoing rapid popularization. Compared with surgical cutdown for femoral access (cEVAR), it offers the advantage of faster recovery after surgery as well as a reduction in wound complications. Despite proposed advantages, the method is largely considered uneconomical because of its reliance on costly closure devices. METHODS: There were 50 patients undergoing EVAR who were enrolled in this randomized prospective single-center trial. Each patient randomly received percutaneous access in one groin and surgical access in the other. The primary end points were access duration and cost. Secondary end points were wound complications and the postoperative pain levels. RESULTS: Surgery was performed per protocol in 44 patients. Mean access times for pEVAR and cEVAR were 11.5 ± 3.4 minutes and 24.8 ± 12.1 minutes (P < .001), respectively. Total access costs were €559.65 ± €112.69 for pEVAR and €674.85 ± €289.55 for cEVAR (P = .016). Eight complications in six patients were attributed to cutdown, none to pEVAR (P = .02). The percutaneously accessed groin was significantly less painful at day 1 and day 5 after surgery (P < .001). An intention-to-treat analysis (N = 50 patients) included six cases of pEVAR conversion due to technical failure in three patients (6%) and change of the operative strategy in another three patients (eg, aortouni-iliac stent graft followed by crossover bypass). The intention-to-treat analysis showed shorter mean overall access time for pEVAR (pEVAR, 14.65 ± 10.20 minutes; cEVAR, 25.12 ± 11.77 minutes; P < .001) and no cost difference between the two methods (pEVAR, €651.29 ± €313.49; cEVAR, €625.53 ± €238.29; P = .65). CONCLUSIONS: Our data confirm proposed potential benefits attributable to the minimally invasive nature of pEVAR while demonstrating cost-effectiveness despite the additional cost of closure devices. Taking into account pEVAR failures still does not increase pEVAR costs over cEVAR. Further considering reduced postoperative pain and wound complications, the technique deserves consideration in suitable patients.


Assuntos
Aneurisma/economia , Aneurisma/cirurgia , Implante de Prótese Vascular/economia , Cateterismo Periférico/economia , Procedimentos Endovasculares/economia , Artéria Femoral/cirurgia , Custos Hospitalares , Idoso , Idoso de 80 Anos ou mais , Aneurisma/diagnóstico por imagem , Áustria , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Redução de Custos , Análise Custo-Benefício , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Artéria Femoral/diagnóstico por imagem , Hematoma/economia , Hematoma/etiologia , Hematoma/terapia , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Dor Pós-Operatória/economia , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/terapia , Hemorragia Pós-Operatória/economia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/terapia , Estudos Prospectivos , Punções , Instrumentos Cirúrgicos/economia , Fatores de Tempo , Resultado do Tratamento , Cicatrização
14.
Vascular ; 26(6): 647-656, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30037302

RESUMO

OBJECTIVES: To study the safety and feasibility of the E-liac Stent Graft System® in patients with aorto/iliac aneurysms. METHODS: A prospective multicentric European registry of patients receiving the E-liac Stent Graft System® was conducted. Endpoints of the study included the technical success as well as periprocedural events and 30-day endoleaks, reinterventions, internal and external iliac artery patency and mortality. RESULTS: Between July 2014 and June 2016, a total of 45 patients (93% men, mean age 72 years, range 53-90 years) were enrolled at 11 sites in four European countries. Five patients received an isolated iliac treatment. Thirty-seven patients were treated with a combination of an abdominal stent graft and a unilateral E-liac and three in combination with bilateral E-liac. All E-liac Stent Grafts (48) were implanted in the intended position and the internal iliac arteries were successfully bridged. Two patients did not receive clinical success, due to endoleak type Ia of the aortic stent graft. At 30-day follow-up, clinical success rate was 96%. Three successful endovascular reinterventions were performed within the 30-day follow-up: one due to a type Ia endoleak in the common iliac artery, one due to type Ia endoleak of the aortic stent graft, and one due to bilateral lower limb claudication provoked by stent graft limb stenosis. At 30-day, a 100% survival rate and complete absence of pelvic or buttock ischemia/claudication were reported. Primary patency at 30 days was 100% for the internal iliac artery and 98% for the external iliac artery with an assisted patency of 100% in the latter. CONCLUSIONS: The high clinical success rate, low rates of device-related reinterventions (2%), and excellent patency rate demonstrate the safety and feasibility of the E-liac Stent Graft System. Long-term results are awaited to state efficacy and durability. Clinical Trials.gov. Identifier no. NCT02209194.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
15.
J Vasc Surg ; 65(6): 1591-1597, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28216360

RESUMO

OBJECTIVE: The fenestrated Anaconda endograft (Vascutek/Terumo, Inchinnan, UK) is intended for the treatment of abdominal aortic aneurysms with an insufficient infrarenal landing zone. The endografts are custom-made with use of high-resolution, 1-mm-slice computed tomography angiography images. For every case, a nonsterile prototype and a three-dimensional (3D) model of the patient's aorta are constructed to allow the engineers as well as the physician to test-implant the device and to review the fit of the graft. The aim of this investigation was to assess the impact of 3D model construction and prototype testing on the design of the final sterile endograft. METHODS: A prospectively held database on fenestrated endovascular aortic repair patients treated at a single institution was completed with data from the Vascutek engineers' prototype test results as well as the product request forms. Changes to endograft design based on prototype testing were assessed and are reported for all procedures. RESULTS: Between April 1, 2013, and August 18, 2015, 60 fenestrated Anaconda devices were implanted. Through prototype testing, engineers were able to identify and report potential risks to technical success related to use of the custom device for the respective patient. Theoretical concerns about endograft fit in the rigid model were expressed in 51 cases (85.0%), and the engineers suggested potential changes to the design of 21 grafts (35.0%). Thirteen cases (21.7%) were eventually modified after the surgeon's testing of the prototype. A second prototype was ordered in three cases (5.0%) because of extensive changes to endograft design, such as inclusion of an additional fenestration. Technical success rates were comparable for grafts that showed a perfect fit from the beginning and cases in which prototype testing resulted in a modification of graft design. CONCLUSIONS: Planning and construction of fenestrated endografts for complex aortic anatomies where exact fit and positioning of the graft are paramount to allow cannulation of the aortic branches are challenging. In the current series, approximately one in five endografts was modified after prototype testing in an aortic model. Eventually, success rates were comparable between the groups of patients with a good primary prototype fit and those in which the endograft design was altered. Prototype testing in 3D aortic models is a valuable tool to test the fit of a custom-made endograft before implantation. This may help avoid potentially debilitating adverse events associated with misaligned fenestrations and unconnected aortic branches.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Stents , Idoso , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Áustria , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Desenho Assistido por Computador , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Modelos Anatômicos , Modelos Cardiovasculares , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Valor Preditivo dos Testes , Impressão Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
16.
J Vasc Surg ; 66(5): 1334-1339, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28559175

RESUMO

OBJECTIVE: Endovascular aortic aneurysm repair (EVAR) with a fenestrated device (FEVAR) allows an extension of the proximal sealing zone above the renal arteries to an adequate, healthier segment of the aorta. This feature makes FEVAR an option to treat patients with a diseased aortic neck or type Ia endoleak after EVAR. The aim of this investigation was to present a single-center experience with FEVAR for patients with an abdominal aortic endograft in situ compared with primary FEVAR. METHODS: A prospectively held database on FEVAR patients treated with the fenestrated Anaconda device (Vascutek/Terumo, Inchinnan, Scotland, United Kingdom) at our institution was screened for individuals who had previously undergone EVAR. RESULTS: Between April 1, 2013, and July 31, 2016, 94 fenestrated Anaconda devices were implanted at our institution. Twelve patients with prior EVAR were treated for pathology of the proximal neck: type I endoleak (n = 7), for stent migration with aneurysm progression but no visible endoleak (n = 2), and progressive aortic disease at the level of the visceral segment (n = 3). When redo cases and primary FEVARs were compared, primary technical success rates were 58.3% and 87.8% (P = .02) and primary functional success rates were 91.7% and 95.1%, respectively (P = .62). Perioperative rate of major deployment-related (14.6% and 16.7%) and systemic complications (8.5% and 8.3%) as well as 30-day mortality (6.1% and 0%; P = .5) were comparable between groups. After an average follow-up interval of 10 months (range, 0-43 months), no late occlusions of connecting stents were observed. The late reintervention rates were 11.0% and 16.7%, respectively (P = .57). CONCLUSIONS: The risk of a failure to cannulate one or more visceral arteries through the respective fenestrations was increased in patients who had previously undergone EVAR. This is most likely caused by increased friction between the fenestrated endograft and the failing graft in situ, which may impair the adaption of the unsupported Anaconda device to the aortic wall. As a consequence, fenestrations may not line up perfectly at the respective openings of the visceral or renal arteries, and folding of the fabric may be increased, making cannulation of the fenestrations more difficult.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/cirurgia , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Bases de Dados Factuais , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
17.
J Vasc Surg ; 63(1): 82-8.e2, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26409844

RESUMO

OBJECTIVE: The benefit of carotid surgery in asymptomatic patients with high-grade internal carotid artery stenosis (ICAS) is subject of intense debate, and thus improved preoperative risk stratification is mandatory. This study aimed to investigate the predictive value of contralateral ICAS (cl-ICAS) for the preoperative clinical presentation of patients with ipsilateral ICAS (primary outcome). METHODS: This study was a post hoc analysis of a prospective cohort comprising 485 consecutive patients undergoing carotid endarterectomy for high-grade ICAS. Patients were classified by their clinical presentation, ie, asymptomatic (n = 213) or symptomatic (within 6 months of surgery; n = 272, comprising both transient ischemic attack [TIA; n = 163] and stroke [n = 109]). We investigated the association of cl-ICAS with the primary outcome in adjusted regression models. RESULTS: Mean ipsilateral degrees of ICAS were similar in both groups (84% ± 10% vs 84% ± 11%; P = .92), whereas contralateral degrees were significantly higher in the symptomatic group (29% ± 34% vs 38% ± 39%; P = .008). After multivariable regression analysis, cl-ICAS >60% conferred a three times higher preoperative stroke risk (odds ratio, 3.31; 95% confidence interval, 1.98-5.54; P < .001). Inclusion of cl-ICAS significantly improved (P = .001) ipsilateral combined TIA and stroke risk prediction based on established risk factors (area under the curve, 0.66; 95% confidence interval, 0.60-0.72; P < .001). CONCLUSIONS: Our study identifies a high contralateral degree of ICAS as an independent predictor of preoperative ipsilateral TIA and stroke in patients with ipsilateral high-grade ICAS. Therefore, such patients might rather benefit from elective carotid surgery and intensive postoperative medical care.


Assuntos
Artéria Carótida Interna/cirurgia , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Ataque Isquêmico Transitório/etiologia , Acidente Vascular Cerebral/etiologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Área Sob a Curva , Doenças Assintomáticas , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Distribuição de Qui-Quadrado , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Estudos Prospectivos , Curva ROC , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler Dupla
18.
J Endovasc Ther ; 23(4): 661-5, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27193307

RESUMO

PURPOSE: To present the off-label use of an iliac side branch device to connect an accessory right renal artery to a bifurcated endograft in infrarenal aortic aneurysm repair. CASE REPORT: An 83-year-old woman with a 54-mm infrarenal abdominal aortic aneurysm underwent endovascular repair using an iliac side branch device for accessory renal artery salvage. The procedure was technically successful, and no immediate perioperative adverse events were encountered. The creatinine level increased slightly. Six-month follow-up imaging revealed no endoleaks or occlusion. CONCLUSION: Considering the higher perioperative risk associated with open or hybrid procedures for similar cases, this off-label application of a well-recognized endovascular device deserves consideration as an alternative treatment option.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Artéria Renal/cirurgia , Stents , Malformações Vasculares/complicações , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Tomografia Computadorizada Multidetectores , Artéria Renal/anormalidades , Artéria Renal/diagnóstico por imagem , Resultado do Tratamento , Malformações Vasculares/diagnóstico por imagem
19.
Wound Repair Regen ; 24(5): 928-935, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27313054

RESUMO

Negative pressure wound therapy (NPWT) is the treatment of choice for chronic wounds; yet, it is associated with considerable workload. Prompted by its nonadhesive and wound-healing properties, this study investigated the effect of an additional polymeric membrane interface dressing (PMD; PolyMem WIC) in NPWT. From October 2011 to April 2013, 60 consecutive patients with chronic leg wounds or surgical site infections after revascularization of lower extremities were randomly allocated to either treatment with conventional NPWT (control arm) or NPWT with an additional PMD (intervention arm). The primary outcome was wound healing achieved within 30 days, the secondary endpoints included: number of days between dressing changes, wound-related pain, cost efficiency, and occurrence of adverse events (ClinTrials.gov Identifier: NCT02399722). Forty-seven patients completed follow-up. No difference in wound healing was observed (p > 0.05) between both study arms. The additional PMD allowed significantly longer wearing times (days) between dressing changes (intervention: 8.8 ± 0.5, control: 4.8 ± 0.2; p < 0.001). Pain was slightly higher in patients randomized to NPWT alone (VAS score: 4.8 ± 2.9) compared to NPWT + PMD (VAS score: 3.0 ± 2.9, p = 0.063). No wound infections were observed. Costs were reduced by 34% per patient in the intervention arm. These results suggest that the combination of NPWT and an additional interface PMD is a safe and economic method for the treatment of chronic wounds, which requires significantly fewer dressing changes for a comparable wound healing.

20.
J Stroke Cerebrovasc Dis ; 25(5): 1235-1243, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26935113

RESUMO

BACKGROUND: Both deficiency and, according to recent reports, excess of vitamin B12 (B12) are associated with increased mortality. Thus, it is difficult to estimate the effect of B12 on overall survival, which also depends on folate (FA) in homocysteine lowering. This study aimed to assess FA and B12 serum concentrations associated with long-term survival of vascular surgery patients by means of a prognostic index (PI). METHODS: This single-center, prospective cohort study comprised 485 consecutive carotid surgery patients. B-vitamin baseline concentrations of B12 and FA were used to compute a PI for postoperative overall survival from January 2003 to January 2012 (mean observation period 102.3 months). RESULTS: Increasing B12 serum concentrations showed a nonlinear association with overall survival (P = .033). A B vitamin-based PI significantly predicted overall (hazard ratio [HR] per standard deviation = 1.97, confidence interval [CI] 1.37-2.82; P < .001), cardiovascular (HR = 3.03, CI 1.78-5.14; P < .001), and stroke-free survival (HR = 2.20, CI 1.22-3.98; P = .009), and revealed that the highest adverse event-free survival was predicted by high FA (16.3 ± 12.9 ng/mL) but only moderate B12 (360.3 ± 156.0 pmol/L) baseline concentrations. CONCLUSIONS: Prediction of increased long-term overall, cardiovascular, and stroke-free survival is based on high FA but only moderate B12 serum concentrations. Excessive B12 concentrations might harbor a potential harm and are no requisite for low homocysteine concentrations. The association between B vitamins and survival might serve either as a tool for risk stratification or, if causative, as effective therapy, if optimal dosing of B vitamins is provided and on-treatment concentrations, including homocysteine and renal functions, are closely monitored.


Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Deficiência de Ácido Fólico/complicações , Ácido Fólico/sangue , Acidente Vascular Cerebral/prevenção & controle , Deficiência de Vitamina B 12/complicações , Vitamina B 12/sangue , Idoso , Áustria , Biomarcadores/sangue , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/mortalidade , Intervalo Livre de Doença , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Feminino , Ácido Fólico/efeitos adversos , Deficiência de Ácido Fólico/sangue , Deficiência de Ácido Fólico/diagnóstico , Deficiência de Ácido Fólico/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Dinâmica não Linear , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento , Vitamina B 12/efeitos adversos , Deficiência de Vitamina B 12/sangue , Deficiência de Vitamina B 12/diagnóstico , Deficiência de Vitamina B 12/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA