Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Surg Endosc ; 36(10): 7647-7651, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36076102

RESUMO

INTRODUCTION: Genetic contributions to hernia development are incompletely understood. This study performed the first comprehensive genome-wide association study (GWAS) for diaphragmatic hernia using a large population-based cohort in the UK Biobank (UKB). METHODS AND PROCEDURES: Two-stage GWAS (discovery and confirmation) was performed for diaphragmatic hernia in the UKB. Briefly, 275,549 and 91,850 subjects were randomly selected for association tests in Stages 1 and 2, respectively. Association tests between 8,568,156 SNPs (genotyped or imputed with MAF > 0.01) in the autosomal genome and diaphragmatic hernia were performed in Stage 1. SNPs with P < 1 × 10-5 were selected for confirmation in Stage 2, and those with P < 0.05 and the same direction of association as Stage 1 were selected for combined association testing; SNPs with combined P < 5 × 10-8 were considered GWAS-significant. LD clumping analysis identified genetically independent chromosomal regions (loci). A genetic risk score (GRS) measured the cumulative risk of independent SNPs in 91,849 additional subjects using odds ratios (ORs) from Stages 1 and 2. RESULTS: 36,351 patients were identified with diaphragmatic hernia (ICD-10 K44). In Stage 1 analysis, 2654 SNPs were associated (P < 1 × 10-5) with diaphragmatic hernia. Stage 2 analysis confirmed 338 SNPs (P < 0.05). In combined analysis, 245 SNPs reached GWAS significance (P < 5 × 10-8). LD clumping analysis revealed 14 independent loci associated with diaphragmatic hernia. Two loci have been previously associated with inguinal hernia at 2p16 (rs181661155) and 11p13 (rs5030123). eQTL analysis suggested genes CRLF1, UBA52, and CALD1 are also significantly associated with these loci. GRS showed significant increase in cases compared to controls (P < 1 × 10-16) and is associated with increased risk of diaphragmatic hernia (P < 1 × 10-7). CONCLUSIONS: We identified 245 SNPs at 14 susceptibility loci associated with diaphragmatic hernia in a large population-based cohort. These results offer insight into pathogenetic mechanisms of diaphragmatic hernia development and may be used in genetic risk scores for pre-operative risk-stratification and clinical prediction models.


Assuntos
Estudo de Associação Genômica Ampla , Hérnia Diafragmática , Bancos de Espécimes Biológicos , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla/métodos , Humanos , Polimorfismo de Nucleotídeo Único , Reino Unido
2.
Surg Endosc ; 36(12): 9410-9415, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35505258

RESUMO

BACKGROUND: Numerous studies show changes in functional lumen imaging probe (FLIP) measurements after myotomy during peroral endoscopic myotomy (POEM), but few report on FLIP measurements at follow-up esophagogastroduodenoscopy (EGD). The purpose of this study was to compare perioperative FLIP measurements to those at follow-up EGD. METHODS: Patients who underwent POEM with FLIP in the operating room and POEM patients who had EGD with FLIP at follow-up were included. FLIP measurements, including diameter (Dmin), pressure, cross-sectional area (CSA), and distensibility index (DI), were analyzed at a 30-mL balloon fill. Differences between measurements at different timepoints were assessed using a two-tailed Wilcoxon signed-rank test. RESULTS: A total of 97 patients who underwent POEM and 28 who underwent EGD with FLIP were analyzed. The average age was 63 ± 18 years and 46.4% of the patients were male. Mean preoperative Eckardt score was 6.5 ± 4.8, decreasing to 1.6 ± 2.0 at follow-up. EGDs were performed at a median of 15 months after surgery. When compared to mean measurements obtained post-myotomy, at the time of EGD, pressure was found to be significantly lower (p = 0.007) and DI significantly higher (p = 0.045). Of the patients who underwent EGD, 70.8% had an increase in DI, 55.6% had evidence of reflux esophagitis, and 81.0% met diagnostic criteria for reflux on esophageal pH monitoring. However, there was no correlation with the development of esophagitis or reflux and increase or decrease in DI at follow-up. CONCLUSIONS: There are significant changes in FLIP measurements between the time of surgery and at follow-up EGD. These results suggest that esophageal remodeling may cause changes in lower esophageal sphincter geometry after POEM and postoperative FLIP targets immediately post-myotomy may need to be adjusted to account for these changes.


Assuntos
Acalasia Esofágica , Esofagite Péptica , Refluxo Gastroesofágico , Miotomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Acalasia Esofágica/diagnóstico , Acalasia Esofágica/cirurgia , Esofagoscopia/métodos , Impedância Elétrica , Seguimentos , Esfíncter Esofágico Inferior/cirurgia , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/etiologia , Refluxo Gastroesofágico/cirurgia , Cirurgia Endoscópica por Orifício Natural/métodos , Resultado do Tratamento
3.
Surg Endosc ; 36(9): 6859-6867, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35102426

RESUMO

BACKGROUND: Flexible endoscopy is a valuable tool for the gastrointestinal (GI) surgeon, creating a need for effective and efficient training curricula in therapeutic endoscopic techniques for trainees and practicing providers. Here, we present a simulation-based modular curriculum using an "into the fire" approach with hands-on pre- and post-testing to teach endoscopic stenting to practicing surgeons. METHODS: Three advanced flexible endoscopy courses were taught by expert surgical endoscopists from 2018 to 2019. The stenting module involved using self-expandable metal stents to manage simulated esophageal and gastroduodenal strictures on a non-tissue GI model. Based on the educational theories of inquiry-based learning, the simulation curriculum was designed with a series of pre-tests, didactics, mentored hands-on instructions, and post-tests. Assessments included a confidence survey, knowledge-based written test, and evaluation form specific to the hands-on performance of endoscopic stenting. RESULTS: Twenty-eight practicing surgeons with varying endoscopic experiences participated in the course. Most of the participants (67.9%) had completed over 100 upper endoscopic procedures and 57.1% were certified in Fundamentals of Endoscopic Surgery. After completing the modular curriculum, participant confidence survey scores improved from 11.4 ± 4.2 to 20.7 ± 4.0 (p < 0.001). Knowledge-based written test scores also improved from 7.1 ± 1.2 to 8.4 ± 0.9 (p < 0.001). In terms of technical performance, overall hands-on performance scores improved from 21.3 ± 2.7 to 28.9 ± 1.2 (p < 0.001) with significant improvement in each individual component of the assessment (all p values < 0.01) and the greatest improvement seen in equipment handling (88%) and flow of procedure (54%). CONCLUSION: Our modular simulation curriculum using an "into the fire" approach to teach endoscopic stenting is effective in improving learner knowledge, confidence, and hands-on performance of endoscopic stenting. This approach to simulation is effective, efficient, and adaptable to teaching practicing surgeons with varying levels of experience.


Assuntos
Treinamento por Simulação , Cirurgiões , Competência Clínica , Simulação por Computador , Currículo , Endoscopia/educação , Humanos , Treinamento por Simulação/métodos , Stents
4.
Surg Endosc ; 36(9): 6801-6808, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35015103

RESUMO

INTRODUCTION: Compliance is the ability of a hollow organ to dilate and increase volume with an increase in pressure, an accurate representation of food bolus transit through the gastroesophageal junction (GEJ). Impedance planimetry system can calculate compliance (change in volume over pressure) and distensibility (cross-sectional area over pressure) of the GEJ. We aim to describe the changes in compliance during anti-reflux surgery and hypothesize that compliance is a better predictor of patient outcomes than distensibility (DI). METHODS AND PROCEDURES: A review of a prospectively maintained quality database was performed. Patients with FLIP measurements during laparoscopic fundoplication between August 2018 and June 2021 were included. GEJ compliance and DI were measured after hernia reduction, cruroplasty, and fundoplication. Patient-reported outcomes were collected through standardized surveys up to 2 years after surgery. A scatter plot was used to identify a correlation between compliance and DI. Comparisons of measurements between time points were made using paired t-tests. Spearman's correlation coefficients (ρ), Wilcoxon rank-sum, and chi-square tests were used to evaluate associations between measurements and outcomes. RESULTS: One hundred and forty-four patients underwent laparoscopic fundoplication. Compliance is strongly associated with DI (r = 0.96), and a comparison of measurements showed similar trends at specific time points during the operation. After hernia reduction, compliance at the GEJ was 168 ± 74 mm3/mmHg, cruroplasty 79 ± 39 mm3/mmHg, and fundoplication 90 ± 33 mm3/mmHg (all comparisons p < 0.05). GEJ compliance of 80-92 mm3/mmHg after fundoplication was associated with the best patient-reported outcome scores. A compliance of ≤ 79 mm3/mmHg had the highest percentage of patients who reported dysphagia. CONCLUSIONS: Compliance and DI are strongly associated displaying the same directional change during anti-reflux surgery. GEJ compliance of 80-92 mm3/mmHg revealed the best patient-reported outcome scores, and avoiding a compliance ≤ 79 mm3/mmHg may prevent postoperative dysphagia. Therefore, GEJ compliance is an underutilized FLIP measurement warranting further investigation.


Assuntos
Transtornos de Deglutição , Refluxo Gastroesofágico , Laparoscopia , Transtornos de Deglutição/cirurgia , Impedância Elétrica , Junção Esofagogástrica/cirurgia , Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Hérnia , Humanos , Laparoscopia/métodos , Resultado do Tratamento
5.
Surg Endosc ; 36(10): 7709-7716, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35169878

RESUMO

INTRODUCTION: Functional luminal imaging probe (FLIP) use during laparoscopic fundoplication (LF) for gastroesophageal reflux disease is well described. However, there is a lack of data on FLIP measurements during magnetic sphincter augmentation (MSA). This study aims to report our institutional experience in performing FLIP during MSA and to compare these measurements to those obtained during Nissen and Toupet fundoplication. METHODS AND PROCEDURES: A retrospective review of a prospectively maintained quality database was performed. Patients who underwent MSA or LF and had FLIP measurements between April 2018 and June 2021 were included. FLIP measurements at the gastroesophageal junction (GEJ) were recorded without pneumoperitoneum at 40 mL balloon fill after hernia reduction, cruroplasty, and MSA or fundoplication. Reflux symptom index (RSI), GERD-HRQL, and dysphagia score were collected up to 2 years. Group comparisons were made using two-tailed Wilcoxon rank-sum and χ2 tests, with statistical significance of p < 0.05. RESULTS: Twenty-seven patients underwent MSA and 100 patients underwent LF (66% Toupet, 34% Nissen). Type III hiatal hernia was present in 3.7% of MSA patients versus over 50% for fundoplication patients. Minimum diameter, cross-sectional area, and distensibility index (DI) were lower after MSA device placement compared to Nissen or Toupet fundoplication (p < 0.05). Postoperative follow-up showed no differences in RSI, GERD-HRQL, and dysphagia score between MSA and Nissen fundoplication (p > 0.05). CONCLUSION: Intraoperative impedance planimetry provided objective information regarding the geometry of the GEJ during MSA. The ring of magnetic beads restores the anti-reflux barrier and transiently opens with food bolus and belching. The magnetic force of the beads may explain why the DI after MSA is lower yet postoperative quality of life is no different than Nissen fundoplication.


Assuntos
Transtornos de Deglutição , Refluxo Gastroesofágico , Laparoscopia , Transtornos de Deglutição/cirurgia , Impedância Elétrica , Esfíncter Esofágico Inferior/cirurgia , Fundoplicatura/métodos , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/cirurgia , Humanos , Laparoscopia/métodos , Qualidade de Vida , Resultado do Tratamento
6.
Surg Endosc ; 36(2): 1536-1543, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33742274

RESUMO

BACKGROUND: The endoluminal functional lumen imaging probe (FLIP) can be used to obtain real-time measurements of the diameter (Dmin), cross-sectional area (CSA), and distensibility of the pylorus before and after peroral pyloromyotomy (POP), an emerging endoscopic treatment for delayed gastric emptying. Our study aims to report our single-center experience in performing POP with FLIP measurements before and after pyloromyotomy. METHODS: A retrospective review of a prospectively maintained gastroesophageal database was performed. Demographic and perioperative data, including intraoperative FLIP measurements of the pylorus before and after POP, were analyzed. Measurements were compared using paired t tests. RESULTS: Thirty-four patients underwent POP between February 2017 and July 2020. Twenty-three (67.7%) patients were male and the average age was 59 years. The etiology of delayed gastric emptying was post-vagotomy in 22 patients, idiopathic gastroparesis in 7 patients, and diabetic gastroparesis in 5 patients. There were no significant differences in pre-myotomy or post-myotomy FLIP measurements when comparing the post-vagotomy versus the gastroparesis groups. There were significant increases in Dmin, CSA, and distensibility index when comparing pre-myotomy and post-myotomy readings for all patients (all p < 0.001). At follow-up, 64.7% of patients reported resolution of all symptoms. CONCLUSION: POP is an effective intervention in patients with delayed gastric emptying. Significant changes in FLIP measurements before and after POP suggest that FLIP may be a useful adjunct in guiding the management of delayed gastric emptying.


Assuntos
Gastroparesia , Miotomia , Piloromiotomia , Impedância Elétrica , Esvaziamento Gástrico , Gastroparesia/diagnóstico por imagem , Gastroparesia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Miotomia/efeitos adversos , Piloromiotomia/métodos , Piloro/cirurgia , Resultado do Tratamento
7.
Surg Endosc ; 36(2): 1609-1618, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33763744

RESUMO

BACKGROUND: There is substantial media and patient interest in the safety of mesh for hernia repair. However, there is a lack of data regarding health-related quality of life (HRQOL) outcomes in patients who undergo inguinal hernia repair (IHR) with mesh. The purpose of this study is report short and long-term postoperative quality of life outcomes in patients following IHR with mesh. METHODS: We analyzed outcomes of 1720 patients who underwent IHR with mesh between 2008 and 2019 at a single institution from a prospectively maintained quality database. All surgeries were performed by four board-certified surgeons. HRQOL outcomes were measured using the Surgical Outcomes Measurement System (SOMS) and Carolinas Comfort Scale (CCS) surveys that were administered preoperatively, 3 weeks, 6 months, 1, 2, and 5 years postoperatively. Survey responses were summarized as mean with standard deviation or frequency with percentage. Postoperative SOMS scores were compared to preoperative scores using the two-tailed paired t test with a significance level of p < 0.05. RESULTS: One (0.1%) patient experienced a mesh infection postoperatively. In terms of complications, 159 (9.2%) developed a seroma, 31 (1.8%) a hematoma, and 36 (2.1%) patients experienced a recurrence. SOMS Pain Impact, SOMS Pain Quality, and SOMS Pain visual analog scale at 3 weeks, 6 months, 1 year, 2 years, and 5 years were all improved from preoperative (all p < 0.05). At 5 years postoperatively, only 3.9%, 3.2%, and 3.1% of patients reported severe or disabling sensation of mesh, pain, and movement limitations, respectively. CONCLUSION: Inguinal hernia repair with mesh results in a low rate of complications. A minority of patients had severe or disabling symptoms at 5-year follow-up and generally reported improvements in pain impact and quality in long-term follow-up.


Assuntos
Hérnia Inguinal , Hérnia Inguinal/complicações , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Humanos , Dor Pós-Operatória/etiologia , Qualidade de Vida , Recidiva , Telas Cirúrgicas/efeitos adversos , Inquéritos e Questionários , Resultado do Tratamento
8.
Surg Endosc ; 36(6): 3893-3901, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34463870

RESUMO

INTRODUCTION: The esophagogastric junction (EGJ) is a complex anti-reflux barrier whose integrity relies on both the intrinsic lower esophageal sphincter (LES) and extrinsic crural diaphragm. During hiatal hernia repair, it is unclear whether the crural closure or the fundoplication is more important to restore the anti-reflux barrier. The objective of this study is to analyze changes in LES minimum diameter (Dmin) and distensibility index (DI) using the endoluminal functional lumen imaging probe (FLIP) during hiatal hernia repair. METHODS: Following implementation of a standardized operative FLIP protocol, all data were collected prospectively and entered into a quality database. This data were reviewed retrospectively for all patients undergoing hiatal hernia repair. FLIP measurements were collected prior to hernia dissection, after hernia reduction, after cruroplasty, and after fundoplication. Additionally, subjective assessment of the tightness of crural closure was rated by the primary surgeon on a scale of 1 to 5, 1 being the loosest and 5 being the tightest. RESULTS: Between August 2018 and February 2020, 97 hiatal hernia repairs were performed by a single surgeon. FLIP measurements collected using a 40-mL volume fill without pneumoperitoneum demonstrated a significant decrease in LES Dmin (13.84 ± 2.59 to 10.27 ± 2.09) and DI (6.81 ± 3.03 to 2.85 ± 1.23 mm2/mmHg) after crural closure (both p < 0.0001). Following fundoplication, there was a small, but also statistically significant, increase in both Dmin and DI (both p < 0.0001). Additionally, subjective assessment of crural tightness after cruroplasty correlated well with DI (r = - 0.466, p < 0.001) and all patients with a crural tightness rating ≥ 4.5 (N = 13) had a DI < 2.0 mm2/mmHg. CONCLUSION: Cruroplasty results in a significant decrease in LES distensibility and may be more important than fundoplication in restoring EGJ competency. Additionally, subjective estimation of crural tightness correlates well with objective FLIP evaluation, suggesting surgeon assessment of cruroplasty is reliable.


Assuntos
Refluxo Gastroesofágico , Hérnia Hiatal , Esfíncter Esofágico Inferior/cirurgia , Junção Esofagogástrica/cirurgia , Fundoplicatura/métodos , Refluxo Gastroesofágico/cirurgia , Hérnia , Hérnia Hiatal/cirurgia , Humanos , Estudos Retrospectivos
9.
Surg Endosc ; 36(9): 6896-6902, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35132450

RESUMO

INTRODUCTION: This study aims to assess the effect of bariatric surgery on patient-reported outcomes of bowel and bladder function. We hypothesized that bariatric surgery does not worsen bowel and bladder function. METHODS AND PROCEDURES: A retrospective review was conducted of a prospectively maintained surgical quality database. We included patients who underwent primary bariatric surgery at a single institution between 2012 and 2020, excluding revisional procedures. Patient-reported outcomes were assessed using Surgical Outcomes Measurement System (SOMS) bowel and bladder function questionnaires at time of pre-operative consult and routine post-operative follow-up visits through 2 years. Data were analyzed using a statistical mixed effects model. RESULTS: 573 patients (80.6% female) were identified with completed SOMS questionnaire data on bowel and bladder function. Of these, 370 (64.6%) underwent gastric bypass, 190 (33.2%) underwent sleeve gastrectomy, and 13 (2.3%) underwent either gastric banding or duodenal switch. Compared to pre-operative baseline scores, patients reported a transient worsening of bowel function at 2-weeks post-op (p = 0.009). However, by 3-months post-op, bowel function improved and was significantly better than baseline (p = 0.006); this improvement was sustained at every point through 2-year follow-up (p = 0.026). Bladder function scores improved immediately at 2-weeks post-op (p = 0.026) and showed sustained improvement through 1-year follow-up. On subgroup analysis, sleeve patients showed greater improvement in bowel function than bypass patients at 1-year (p = 0.031). Multivariable analysis showed significant improvement in bowel function associated with greater total body weight loss (TBWL) (p = 0.002). CONCLUSIONS: Bariatric surgery does not worsen patient-reported bowel or bladder function. In fact, there is overall improvement from pre-operative scores for both bowel and bladder function by 3-months post-op which is sustained through 2-year and 1-year follow-up, respectively. Most encouragingly, a greater TBWL is significantly associated with improved bowel function after bariatric surgery.


Assuntos
Cirurgia Bariátrica , Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Cirurgia Bariátrica/métodos , Feminino , Gastrectomia/métodos , Derivação Gástrica/métodos , Humanos , Laparoscopia/métodos , Masculino , Obesidade Mórbida/complicações , Obesidade Mórbida/cirurgia , Medidas de Resultados Relatados pelo Paciente , Estudos Retrospectivos , Resultado do Tratamento , Bexiga Urinária/cirurgia , Redução de Peso
10.
Surg Innov ; 29(2): 241-248, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34403287

RESUMO

Background. There are growing interests from practicing endoscopists to implement the functional lumen imaging probe (FLIP) impedance planimetry system. We present a simulation-based curriculum using an "into the fire" approach with hands-on pre- and post-tests to teach the use of this technology. Methods. The curriculum consists of a series of pre-tests, didactic content, mentored hands-on instructions, and post-tests. Pre- and post-testing included a knowledge-based written test, a confidence survey, and an assessment form specific to the hands-on performance of FLIP. Result. Twenty-two practicing physicians completed the curriculum. After course completion, participants had improved knowledge-based written test scores from 6.8±1.7 to 8.9±0.9 (P<0.001), confidence scores from 10.0±5.9 to 22.1±2.6 (P<0.001), and hands-on performance score from 11.4±3.4 to 23.1±2.0 (P<0.001) with significant improvement in all components of the hands-on skills. Conclusion. Our simulation curriculum is effective in improving confidence, knowledge, and technical proficiency when teaching the use of FLIP to practicing physicians.


Assuntos
Currículo , Médicos , Competência Clínica , Impedância Elétrica , Humanos
11.
Endoscopy ; 53(7): 722-726, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33096576

RESUMO

BACKGROUND: Zenker's peroral endoscopic myotomy (Z-POEM) is a novel procedure for the management of symptomatic Zenker's diverticulum. This study aims to report the technical feasibility and outcomes of Z-POEM in the management of Zenker's diverticulum after prior failed interventions. METHODS: Patients with persistent or recurrent symptoms after prior endoscopic and/or surgical intervention for Zenker's diverticulum were retrospectively included. The primary outcome was clinical success, defined as complete or near complete resolution of dysphagia (dysphagia score of 0 or 1) without the need for repeat endoscopic or surgical intervention during follow-up. RESULTS: Z-POEM was technically successful in 30/32 patients (93.8 %). Clinical success was achieved in 29/30 patients (96.7 %), and Z-POEM significantly reduced the median (interquartile range [IQR]) dysphagia score of patients from 2 (1 - 2) to 0 (0) (P < 0.001) over a median duration of follow up of 166 days (IQR 39 - 566). Four patients (12.5 %) had adverse events (two inadvertent mucosotomies and two leaks found on post-procedural esophagrams). CONCLUSION: Z-POEM is feasible, safe, and effective in the majority of patients with recurrent symptoms after prior surgical or endoscopic interventions.


Assuntos
Miotomia , Divertículo de Zenker , Estudos de Viabilidade , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Divertículo de Zenker/cirurgia
12.
Surg Endosc ; 35(12): 7174-7182, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33237465

RESUMO

BACKGROUND: Anti-reflux mucosectomy (ARMS) is a new endoscopic procedure involving a hemi-circumferential endoscopic mucosal resection (EMR) around the gastroesophageal junction. We aim to compare perioperative and quality of life outcomes of patients with reflux who underwent ARMS to a comparable group who underwent laparoscopic Nissen fundoplication (NF). METHODS: A retrospective review of a prospectively maintained quality database was performed. All patients who underwent ARMS (n = 33) were matched with patients who underwent NF (n = 67). Clinical and quality of life (QOL) outcomes were collected preoperatively and up to two years postoperatively, measured by the Reflux Symptom Index (RSI), Gastroesophageal Reflux Disease-Health Related Quality of Life (GERD-HRQL), and Dysphagia Score. Outcomes were compared using the Wilcoxon rank-sum and Fisher's exact test. RESULTS: While 10 patients (30.3%) who underwent ARMS required additional laparoscopic anti-reflux operations, the ARMS group had shorter OR time (p<0.001), less estimated blood loss (p<0.001), shorter hospital stay (p<0.001), less pain at discharge (p = 0.007), earlier narcotic discontinuation (p<0.001), and earlier return to activities of daily living (p<0.001) compared to the NF group. There was no difference in 30-day complication rates, emergency room visits, or readmission rates between the groups. There was no difference between ARMS and NF groups in terms of GERD-HRQL, RSI, or Dysphagia scores at 3 weeks, 6 months, 1 year, or 2 years postoperatively. However, the ARMS group reported less symptoms of gas and bloating postoperatively at all time points (all p<0.05). Both groups reported increased dysphagia at 3 weeks postoperatively (p<0.01) but this did not persist at 6 months, 1 year, or 2 years. CONCLUSION: While ARMS had better perioperative outcomes compared to NF, reflux quality of life outcomes were comparable. ARMS can be an effective endoscopic intervention for GERD when performed on appropriately selected patients without limiting future laparoscopic anti-reflux interventions.


Assuntos
Refluxo Gastroesofágico , Laparoscopia , Atividades Cotidianas , Fundoplicatura , Refluxo Gastroesofágico/cirurgia , Humanos , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
13.
Surg Endosc ; 35(7): 3971-3980, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32780244

RESUMO

BACKGROUND: Although peroral endoscopic myotomy (POEM) has emerged as a highly efficacious procedure in the treatment of a variety of esophageal motility disorders, currently no standard pathway for postprocedural care exists. Our study aims to report institutional outcomes in performing POEM as an outpatient procedure with same-day discharge. Additionally, we seek to determine factors associated with admission. METHODS: Demographic, perioperative, and postoperative outcome data of 115 patients who underwent POEM between June 2014 and January 2020 on a same-day discharge pathway were analyzed. Cohorts were compared using the t test, Wilcoxon rank-sum, or chi-square test. Multivariable logistic regression with a manual backward selection method was used to identify factors associated with admission. RESULTS: Fifty-five patients (48%) were successfully discharged same-day. The most common primary reasons for admission were delay in obtaining an esophagram (25%), intraoperative complication (13.3%), and pain (10%). There were no differences in 30-day ED visit rate (12.7% vs 15.0%, p = 0.725) or 30-day readmission rate (9.1% vs 16.7%, p = 0.373) between patients who were discharged same-day versus patients who were admitted. Patients discharged same-day had fewer intraoperative complications (1 vs 9, p = 0.017), shorter OR time (69 vs 100 min, p < 0.001), and earlier cessation of narcotic use (day 0 vs day 1, p = 0.001). On multivariable analysis, intraoperative complication (p = 0.048) was associated with overnight admission. CONCLUSION: Patients did not experience additional morbidity with same-day discharge after POEM. A delay in obtaining an esophagram was the most common reason that patients were admitted and those who suffered an intraoperative complication are more likely to require admission.


Assuntos
Acalasia Esofágica , Transtornos da Motilidade Esofágica , Miotomia , Cirurgia Endoscópica por Orifício Natural , Acalasia Esofágica/cirurgia , Esfíncter Esofágico Inferior , Esofagoscopia , Hospitalização , Humanos , Alta do Paciente , Estudos Retrospectivos , Resultado do Tratamento
14.
Surg Endosc ; 35(6): 2781-2788, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32720173

RESUMO

BACKGROUND: Outcomes of incisional hernia repair (IHR) include recurrence and quality of life (QOL). Operative approaches include laparoscopic, open, and robotic approaches. Data regarding comparative QOL outcomes among these repair types are unknown. Our study evaluates quality of life after three approaches to IHR. STUDY DESIGN: Patients undergoing open (OHR), laparoscopic (LIHR), and robotic extra-peritoneal (RIHR) at a single institution from 2009 to 2019 were reviewed from a prospectively managed quality database. Short-term QOL was compared among the three procedures using the Surgical Outcomes Measurement System (SOMS) and Carolinas Comfort Scale (CCS), objective pain scores and postoperative narcotic use. Data regarding length of stay (LOS), emergency department (ED) visits, readmission, reoperations and surgical site infection (SSI) were also collected. RESULTS: A total of 795 patients undergoing IHR were analyzed (418 open, 300 laparoscopic and 77 robotic). Patient were similar in age, gender and co-morbidities. LIHR patients had higher BMI and RIHR patients had larger hernia and mesh size. LOS was longer and rate of SSI was higher for OIHR compared to laparoscopic and RIHR. Patients undergoing LIHR reported increased narcotic use, Visual Analogue Scale (VAS) and CCS pain scores compared to open and robotic repair. Return to daily activity was 4 days shorter for robotic than open and laparoscopic repair; ED visits, readmissions, reoperations, and other QOL domains were similar. CONCLUSION: Our data suggests that short-term quality of life after robotic extra-peritoneal IHR is improved compared to open and laparoscopic repair. Additional follow up is required to determine differences in long-term QOL after IHR.


Assuntos
Hérnia Inguinal , Hérnia Incisional , Laparoscopia , Qualidade de Vida , Procedimentos Cirúrgicos Robóticos , Hérnia Inguinal/cirurgia , Herniorrafia/efeitos adversos , Humanos , Hérnia Incisional/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos
15.
Surg Endosc ; 35(8): 4555-4562, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32789722

RESUMO

INTRODUCTION: Peroral endoscopic myotomy (POEM) is a minimally invasive treatment for achalasia. Considerable evidence demonstrates a high incidence of gastroesophageal reflux disease (GERD) after POEM. The endoluminal functional lumen imaging probe (FLIP) uses impedance planimetry to obtain objective measurements of the gastroesophageal junction. This study aims to determine whether FLIP measurements collected at the time of POEM are associated with the development of reflux esophagitis postoperatively. METHODS: Patients who underwent POEM between 2012 and 2019 who subsequently had esophagogastroduodenoscopy (EGD) were included. Intraoperative FLIP measurements before and after myotomy, clinical data from EGD, and reflux specific quality of life questionnaires were collected. Comparisons between groups were made using the Wilcoxon rank-sum and Fisher's exact tests. Receiver operating characteristic (ROC) curves were used to determine optimal cutoffs of measurements to classify patients into those with high risk of postoperative esophagitis and those with lower risk. RESULTS: A total of 43 patients were included. Of those, 25 (58.1%) were found to have esophagitis on postoperative EGD: four patients (16%) with LA Grade A, five (20%) with LA Grade B, 11 (44%) with LA Grade C and two (8%) with LA grade D esophagitis. Patients with a final distensibility index ≥ 2.7 and a final cross-sectional area ≥ 83 were significantly more likely to develop esophagitis on postoperative EGD (p = 0.016 and p = 0.008, respectively). Gastroesophageal reflux disease health-related quality of life (GERD-HRQL) and reflux symptom index (RSI) scores were not significantly different in patients who developed esophagitis and those who did not. CONCLUSION: Reflux affects some patients after POEM. We show that FLIP measurements collected during POEM may help predict which patients are more likely to develop reflux esophagitis postoperatively. Subjective symptoms on quality of life questionnaires are not reliable in determining which patients are at risk for esophagitis.


Assuntos
Acalasia Esofágica , Esofagite Péptica , Miotomia , Cirurgia Endoscópica por Orifício Natural , Impedância Elétrica , Acalasia Esofágica/cirurgia , Esofagite Péptica/diagnóstico , Esofagite Péptica/epidemiologia , Esofagite Péptica/etiologia , Esofagoscopia , Humanos , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Qualidade de Vida , Resultado do Tratamento
16.
Surg Endosc ; 35(10): 5717-5723, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32970210

RESUMO

INTRODUCTION: The Endoluminal Functional Lumen Imaging Probe (Endoflip) can be used to provide objective measurements of the gastroesophageal junction during fundoplication, and recent publications have suggested that this device could improve surgical outcomes. However, the impact of operative variables has not been clearly reported. The aim of this study is to determine the effect of these variables on functional lumen imaging probe (FLIP) measurements. METHODS: Following implementation of a standardized operative FLIP protocol, all data were collected prospectively and entered into a quality database. This database was queried for patients undergoing hiatal hernia repair and fundoplication. The protocol utilized various balloon volumes (30 and 40 ml), patient positions (flat and reverse Trendelenburg) and amounts of insufflation (15 mmHg pneumoperitoneum and no pneumoperitoneum). RESULTS: Between August 2018 and February 2020, 97 fundoplications were performed by a single surgeon. Multivariable analysis without interactions demonstrated that a 40 ml volume fill resulted in significantly higher minimum diameter (Dmin), cross-sectional area (CSA), intra-balloon pressure (IBP) and distensibility index (DI) compared to a 30 ml volume fill (p < 0.001). While reverse Trendelenburg positioning resulted in a significantly higher Dmin, IBP and CSA compared to the flat position (all p < 0.05), there was little impact of positioning on DI. Lastly, pneumoperitoneum significantly increased IBP (p < 0.001) but did not affect Dmin (p = 0.697) or CSA (p = 0.757), which resulted in a significant decrease in DI (p < 0.001) when compared to measurements without pneumoperitoneum. Multivariable analysis allowing for interactions demonstrated significant two-way interactions between balloon volume and pneumoperitoneum (p = 0.047), as well as patient position and pneumoperitoneum (p < 0.001). CONCLUSION: Surgeons should consider balloon volume and the presence or absence of pneumoperitoneum when interpreting distensibility during or after fundoplication. Additionally, we suggest a formal standardized protocol for FLIP measurements to utilize a 40 ml volume fill in reverse Trendelenburg without pneumoperitoneum.


Assuntos
Esofagoplastia , Insuflação , Junção Esofagogástrica , Esôfago , Fundoplicatura , Humanos
17.
Surg Endosc ; 35(7): 3961-3970, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32749611

RESUMO

BACKGROUND: The purpose of this study was to analyze non-dysplastic Barrett's esophagus (NDBE) biopsy tissue and compare the rate of somatic DNA copy number alterations (CNAs) in patients who subsequently progressed to high-grade dysplasia (HGD) or esophageal adenocarcinoma (EAC) to those patients who did not. METHODS: A retrospectively collected database of Barrett's esophagus (BE) patients spanning a 16-year period was queried. Patients who progressed from NDBE to HGD or EAC were identified and compared to patients who did not. Initial biopsy specimens were microdissected and extracted DNA underwent Multiplex Ligation-dependent Probe Amplification (MLPA) for CNAs. Comparisons between progressors and non-progressors were made with Fisher's exact and two-sample t tests. Logistic regression assessed factors associated with progression. RESULTS: Of the 2459 patients in the BE database, 36 patients progressed from NDBE to either HGD or EAC. There were eight progressors who had biopsy specimens with adequate DNA for analysis. The progressor and non-progressor cohort had similar demographic information and medical history. The progressor group trended towards being older at diagnosis (72 ± 10 vs. 64 ± 13 years, p = 0.097) and fewer progressors reported reflux symptoms (50 vs. 94.7%, p < 0.001). Progressor specimens had more overall CNAs (75% vs. 33.6%, p = 0.026). On univariable analysis, there was an association between progression and absence of GERD symptoms (OR 16.54 [3.42-80.03], p = 0.001), any CNA (OR 5.10 [1.18-23.30], p = 0.035), and CNA in GATA6 or ERBB2 (OR 6.72 [1.18-38.22], p = 0.032). CONCLUSIONS: Patients who progressed from NDBE to HGD or EAC were older at first diagnosis of BE and fewer of the progressors reported symptoms of reflux when compared to non-progressors. Progression was associated with the presence of any CNA and specific CNAs in GATA6 or ERBB2.


Assuntos
Esôfago de Barrett , Esôfago de Barrett/genética , DNA , Variações do Número de Cópias de DNA , Progressão da Doença , Humanos , Estudos Retrospectivos
18.
J Gastrointest Surg ; 27(8): 1531-1538, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37052876

RESUMO

BACKGROUND: Endoscopic sleeve gastroplasty is an example of endoscopic sutured plications being used to remodel a gastrointestinal organ. With per-oral plication of the esophagus (POPE), similar plications are used to remodel the dilated and redundant megaesophagus of end-stage achalasia. Redundancies and dilations can also develop in the neoesophagus of a patient with prior esophagectomy. Megaesophagus and a redundant neoesophagus can both lead to debilitating dysphagia, regurgitation, and recurrent aspiration pneumonia. Traditionally, this anatomic problem requires complex revisional or excisional surgery, to which POPE offers an incisionless alternative. METHODS: This is a dynamic manuscript with video demonstration of POPE, as well as review of five cases performed in 1 year. Data were collected in a prospectively maintained database, and the institutional review board approved retrospective review for this publication. The procedure is performed using a dual-channel upper endoscope fixed with an endoscopic suturing device, with the patient supine under general anesthesia. RESULTS: POPE was technically completed in all cases with no serious complications, and patients either went home the same day or spent one night for observation. Most patients reported immediate and substantial symptomatic improvement. Objective pre- and post-measures include esophagram and nuclear gastric emptying studies. CONCLUSION: This article discusses early experience at one institution with POPE, with detailed description of the procedure and technical considerations. An accompanying video reviews two cases, one with megaesophagus and one with a gastric conduit. While this novel procedure has limited and rare indications, it offers a low-morbidity solution to a challenging anatomic problem that traditionally requires invasive surgery.


Assuntos
Acalasia Esofágica , Gastroplastia , Humanos , Acalasia Esofágica/cirurgia , Estudos de Viabilidade , Estômago/cirurgia , Gastroplastia/métodos , Resultado do Tratamento
19.
Am J Surg ; 225(2): 252-257, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36058753

RESUMO

BACKGROUND: The ideal approach to inguinal hernia repair (IHR) after prior pelvic or low abdominal surgery is not agreed upon. We compared safety and outcomes of IHR between open, laparoscopic, and robotic approaches. METHODS: This retrospective review of a prospective database analyzed demographic, perioperative, and quality of life data for patients who underwent IHR after pelvic or low abdominal surgery. RESULTS: 286 qualifying patients underwent IHR between 2008 and 2020; 119 open, 147 laparoscopic, and 20 robotic. Laparoscopic repair led to faster cessation of narcotics and return to ADLs than open repair (all p <0.05). Post-operative complications, 30-day readmission, recurrences, and quality of life outcomes were equivalent, except less pain at 3-weeks post-op in the minimally invasive groups, p < 0.01. CONCLUSION: Minimally invasive IHR after prior pelvic or low abdominal surgery is safe compared to an open approach. Laparoscopic repair provides faster recovery, yet patient satisfaction is equivalent regardless of surgical approach.


Assuntos
Hérnia Inguinal , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Hérnia Inguinal/cirurgia , Qualidade de Vida , Herniorrafia , Estudos Retrospectivos
20.
J Gastrointest Surg ; 26(1): 21-29, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34647227

RESUMO

INTRODUCTION: A short floppy fundoplication has been the surgical dogma to prevent dysphagia and gas-bloat after laparoscopic fundoplication while adequately addressing gastroesophageal reflux disease. The literature on the ideal length of narrowing (LON) of the gastroesophageal junction after fundoplication is sparse. The functional luminal imaging probe (FLIP) can be used during anti-reflux surgery to produce a visual representation of the LON. We hypothesize that a longer LON provides relief of GERD symptoms, however worse dysphagia and gas-bloat. METHODS AND PROCEDURES: Prospectively collected data was analyzed. Patients with FLIP measurements during laparoscopic fundoplication between August 2018 and December 2020 were included. FLIP measurements at the gastroesophageal junction were recorded without pneumoperitoneum at 40-mL balloon fill after fundoplication. Reflux Symptom Index (RSI), Gastroesophageal Reflux Disease-Health Related Quality of Life Questionnaire (GERD-HRQL), gas-bloat score, and Dysphagia Score were collected. Comparisons were made using Spearman correlation coefficients (r) and two-tailed Wilcoxon rank-sum tests, with statistical significance set at p < 0.05. RESULTS: One hundred and eleven patients underwent laparoscopic fundoplication (26% Nissen, 74% Toupet) and had FLIP measurements. Mean LON in this cohort was 2.7 ± 0.8 cm and mean DI was 3.5 ± 1.3 mm2/mmHg. LON is inversely associated with RSI (r = - 0.29, p = 0.04) and gas-bloat (r = - 0.30, p = 0.04). There was no association with Dysphagia Score. Patients with a LON of 2.5-4.5 cm and DI of 2.5-3.6 mm2/mmHg after fundoplication reported lower RSI (p = 0.03) and GERD-HRQL (p = 0.04) compared to patients outside of these ranges. There were no significant differences in patient-reported dysphagia or gas-bloat scores at 1 year between these groups. CONCLUSIONS: Impedance planimetry provides objective real-time measurements and images during anti-reflux surgery, which allows surgeons to measure the length of narrowing after fundoplication. A LON of 2.5-4.5 cm and DI of 2.5-3.6 mm2/mmHg after fundoplication led to better postoperative quality of life at 1 year without an increase in postoperative dysphagia or gas-bloat.


Assuntos
Transtornos de Deglutição , Laparoscopia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/prevenção & controle , Impedância Elétrica , Fundoplicatura , Humanos , Qualidade de Vida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA