Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(3)2024 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-38542551

RESUMO

Micro-machining is a widespread finishing process for fabricating accurate parts as biomedical devices. The continuous effort in reducing the gap between the micro- and macro-domains is connected to the transition from conventional to micro-scale machining. This process generates several undesired issues, which complicate the process's optimization, and tool run-out is one of the most difficult phenomena to experimentally investigate. This work focuses on its analytical description; in particular, a new method to calibrate the model parameters based on cutting force signal elaboration is described. Today, run-out prevision requires time-consuming geometrical measurements, and the main aim of our innovative model is to make the analysis completely free from dimensional measurements. The procedure was tested on data extrapolated from the micro-machining of additively manufactured AlSi10Mg specimens. The strategy appears promising because it is built on a strong mathematical basis, and it may be developed in further studies.

2.
Micromachines (Basel) ; 12(11)2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34832705

RESUMO

Ultraprecision micromachining is a technology suitable to fabricate miniaturized and complicated 3-dimensional microstructures and micromechanisms. High geometrical precision and elevated surface finishing are both key requirements in several manufacturing sectors. Electronics, biomedicals, optics and watchmaking industries are some of the fields where micromachining finds applications. In the last years, the integration between product functions, the miniaturization of the features and the increasing of geometrical complexity are trends which are shared by all the cited industrial sectors. These tendencies implicate higher requirements and stricter geometrical and dimensional tolerances in machining. From this perspective, the optimization of the micromachining process parameters assumes a crucial role in order to increase the efficiency and effectiveness of the process. An interesting example is offered by the high-end horology field. The optimization of micro machining is indispensable to achieve excellent surface finishing combined with high precision. The cost-saving objective can be pursued by limiting manual post-finishing and by complying the very strict quality standards directly in micromachining. A micro-machining optimization technique is presented in this a paper. The procedure was applied to manufacturing of main-plates and bridges of a wristwatch movement. Cutting speed, feed rate and depth of cut were varied in an experimental factorial plan in order to investigate their correlation with some fundamental properties of the machined features. The dimensions, the geometry and the surface finishing of holes, pins and pockets were evaluated as results of the micromachining optimization. The identified correlations allow to manufacture a wristwatch movement in conformity with the required technical characteristics and by considering the cost and time constraints.

3.
Materials (Basel) ; 13(4)2020 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-32093226

RESUMO

The change from a consolidated manufacturing practice to a new solution is often a complex problem because of the operative limits of technologies and the strict constraints of industrial parts. Moreover, the new process must reflect or enhance the characteristics of the product and, overall, it must be more competitive in performances and costs. Accordingly, the development of a new process is a multilevel and multivariate problem that requires a systematic and hierarchical approach. The present paper focuses on the development of a Tube Hydroforming process capable to replace the current practice for production of T-Joint parts made of AISI 316L for the water pipes market. In particular, the problem must withstand many process and product constraints. Therefore, it was split in three steps focused on specific aspects of the process: identification of process parameters and configuration, numerical optimization of the blank tube dimensions (length and thickness), experimental tests and final improvements. In particular, two numerical methods were implemented in the optimization step: the line-search method to approach to the optimum point and Bisection method to refine the search. These approaches allowed us to identify the optimum process configuration and, in particular, the optimal dimensions of the blank tube that allows one to achieve the product requirements with the minimum cost of material.

4.
Materials (Basel) ; 12(13)2019 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-31323945

RESUMO

Cobalt-chromium-molybdenum (Co-Cr-Mo) alloys are very promising materials, in particular, in the biomedical field where their unique properties of biocompatibility and wear resistance can be exploited for surgery applications, prostheses, and many other medical devices. While Additive Manufacturing is a key technology in this field, micro-milling can be used for the creation of micro-scale details on the printed parts, not obtainable with Additive Manufacturing techniques. In particular, there is a lack of scientific research in the field of the fundamental material removal mechanisms involving micro-milling of Co-Cr-Mo alloys. Therefore, this paper presents a micro-milling characterization of Co-Cr-Mo samples produced by Additive Manufacturing with the Selective Laser Melting (SLM) technique. In particular, microchannels with different depths were made in order to evaluate the material behavior, including the chip formation mechanism, in micro-milling. In addition, the resulting surface roughness (Ra and Sa) and hardness were analyzed. Finally, the cutting forces were acquired and analyzed in order to ascertain the minimum uncut chip thickness for the material. The results of the characterization studies can be used as a basis for the identification of a machining window for micro-milling of biomedical grade cobalt-chromium-molybdenum (Co-Cr-Mo) alloys.

5.
Micromachines (Basel) ; 8(7)2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-30400420

RESUMO

The interest in micro manufacturing processes is increasing because of the need for components characterized by small dimensions and micro features. As a result, researchers are studying the limitations and advantages of these processes. This paper deals with tool run-out measurement in micro milling. Among the effects of the scale reduction from macro to micro, tool run-out plays an important role, affecting cutting force, tool life, and the surface integrity of the produced part. The aim of this research is to develop an easy and reliable method to measure tool run-out in micro milling. This measuring strategy, from an Industry 4.0 perspective, can be integrated into an adaptive model for controlling cutting force, with the aim of improving the production quality and the process stability, while at the same time reducing tool wear and machining costs. The proposed procedure deduces tool run-out from the actual tool diameter, the channel width, and the cutting edge's phase, which is estimated by analyzing the cutting force signal. In order to automate the cutting edge phase measurement, the suitability of two functions approximating the force signal was evaluated. The developed procedure was tested on data from experimental tests. A Ti6Al4V sample was machined using two coated micro end mill flutes made by SECO setting different run-out values. The results showed that the developed procedure can be used for tool run-out estimation.

6.
Materials (Basel) ; 6(9): 4268-4283, 2013 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-28788331

RESUMO

In the most recent decades the introduction of unconventional machining processes allowed the development of micromachining techniques. In this work, the influence of material microstructures on the micromilling process was investigated. Ti6Al4V alloy was selected as workpiece material since it is a very common material for micro applications and because its duplex microstructure can be easily changed by proper thermal treatments. Four different microstructures (namely bimodal, fully equiaxed, fully lamellar and mill annealed) were obtained through recrystallization annealing treatments carried out at different times and temperatures. The mechanical properties of the samples were assessed by microhardness measurements. Nano-indentations were also performed on single grains to understand how the different hardness of phases and structures present in the Ti6Al4V alloy can affect the micromilling process. Microchannels using two flute flat end mills with a diameter equal to 200 µm were realized on the treated samples. Two different feed-per-tooth values were used during the tests. Cutting force, channel shape and burr dimension were investigated. Morphological and energy dispersive spectroscopy (EDS) analyses were performed on tools by means of a scanning electron microscope (SEM): in this way the phenomena mainly influencing the tool status were also identified. Lower cutting forces and reduced tool wear were observed when working fully lamellar microstructures compared to the other ones.

7.
Materials (Basel) ; 6(4): 1434-1451, 2013 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-28809219

RESUMO

Miniaturization encourages the development of new manufacturing processes capable of fabricating features, like micro-channels, in order to use them for different applications, such as in fuel cells, heat exchangers, microfluidic devices and micro-electromechanical systems (MEMS). Many studies have been conducted on heat and fluid transfer in micro-channels, and they appeared significantly deviated from conventional theory, due to measurement errors and fabrication methods. The present research, in order to deal with this opportunity, is focused on a set of experiments in the micro-milling of channels made of aluminum, titanium alloys and stainless steel, varying parameters, such as spindle speed, depth of cut per pass (ap), channel depth (d), feed per tooth (fz) and coolant application. The experimental results were analyzed in terms of dimensional error, channel profile shape deviation from rectangular and surface quality (burr and roughness). The micro-milling process was capable of offering quality features required on the micro-channeled devices. Critical phenomena, like run-out, ploughing, minimum chip thickness and tool wear, were encountered as an explanation for the deviations in shape and for the surface quality of the micro-channels. The application of coolant and a low depth of cut per pass were significant to obtain better superficial quality features and a smaller dimensional error. In conclusion, the integration of superficial and geometrical features on the study of the quality of micro-channeled devices made of different metallic materials contributes to the understanding of the impact of calibrated cutting conditions in MEMS applications.