Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acad Radiol ; 25(8): 1075-1086, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29398436

RESUMO

RATIONALE AND OBJECTIVES: This study aims to determine the optimal photon energy for image quality of the pulmonary arteries (PAs) on dual-energy computed tomography (CT) pulmonary angiography (CTPA) utilizing low volumes of iodinated contrast. MATERIALS AND METHODS: The study received institutional review board exemption and was Health Insurance Portability and Accountability Act compliant. Adults (n = 56) who underwent dual-energy CTPA with 50-60 cc of iodinated contrast on a third-generation dual-source multidetector CT were retrospectively and consecutively identified. Twelve virtual monoenergetic kiloelectron volt (keV) image data sets (40-150 keV, 10-keV increments) were generated with a second-generation noise-reducing algorithm. Standard regions of interest were placed on main, right, left, and right interlobar pulmonary arteries; pectoralis muscle; and extrathoracic air. Attenuation [mean CT number (Hounsfield unit, HU)], noise [standard deviation (HU)], signal to noise (SNR), and contrast to noise ratio were evaluated. Three blinded chest radiologists rated (from 1 to 5, with 5 being the best) randomized monoenergetic and weighted-average images for attenuation and noise. P <.05 was considered significant. RESULTS: Region of interest mean CT number increased as keV decreased, with 40 keV having the highest value (P < .001). Mean SNR was highest for 40-60 keV (P <.05) (14.5-14.7) and was higher (P <.05) than all remaining energies (90-150 keV) for all vessel regions combined. Contrast to noise ratio was highest for 40 keV (P <.001) and decreased as keV increased. SNR was highest at 60 and 70 keV, only slightly higher than 40-50 keV (P <.05). Reader scores for 40-50 keV were greater than other energies and weighted-average images (P <.05). CONCLUSIONS: Kiloelectron volt images of 40-50 keV from the second-generation algorithm optimize attenuation on dual-energy CTPA and can potentially aid in interpretation and avoiding nondiagnostic examinations.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Tomografia Computadorizada Multidetectores/normas , Artéria Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Músculos Peitorais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA