Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
1.
J Periodontal Res ; 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38764133

RESUMO

AIM: We investigated the in vitro effect of Limosilactobacillus reuteri DSM 17938 supernatant on the inflammatory response of human gingival fibroblasts (HGF) challenged by lipopolysaccharide (LPS) or elevated glucose levels. METHODS: HGF were exposed to LPS (1 µg/mL), glucose (5, 12 mM or 25 mM), and dilutions of supernatant prepared from L. reuteri DSM 17938 (0.5 × 107, 1.0 × 107, 2.5 × 107, and 5.0 × 107 CFU/mL). After 24 h cell viability and levels of cytokines (IL-1ß, IL-6 and IL-8) and TLR-2 were determined. RESULTS: None of the tested L. reuteri (DSM 17938) supernatant concentrations reduced the viability of HGF. Supernatant concentrations (2.5 × 107 and 5 × 107 CFU/mL) significantly (p < .05) decreased the production of IL-1ß, IL-6, IL-8, and TLR-2 in the presence of LPS. In contrast, inflammatory markers were not reduced by L. reuteri supernatant in the presence of glucose. Glucose concentrations of 12 mM and 24 mM still lead to an elevated production of the investigated biochemical mediators. CONCLUSION: While L. reuteri (DSM 17938) supernatant attenuates the inflammatory response of HGF to LPS in a dose-dependent manner, elevated glucose levels suppress this action. These in vitro results support the overall anti-inflammatory efficacy of L. reuteri supplementation in plaque-associated periodontal inflammations.

2.
Clin Oral Investig ; 23(1): 1-20, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30382412

RESUMO

OBJECTIVE: To provide a systematic overview on the efficacy of green tea catechin as an adjunct to scaling and root planing (SRP) in terms of probing pocket depth (PPD). MATERIALS AND METHODS: A systematic literature search was performed using electronic databases in PubMed, Scopus, Medline, Cochrane, CINAHL, and Web of Science on randomized clinical trials up to January 2017. The research question was posed in accordance with PRISMA guidelines. RESULTS: The search provided 234 studies. After analyzing the full texts, five studies were included, with four studies qualifying for meta-analysis. Mean PPD reduction was significantly higher (α = 0.05) when green tea catechin was used as an adjunct to SRP (test group) than with SRP alone (control group). The difference in the reduction was 0.74 mm [0.35-1.13; 95% CI]. CONCLUSION: The local application of green tea catechin as an adjunct to SRP may result in a beneficial reduction in PPD. Due to the highly heterogeneous data and some risk of bias, however, this data still needs to be interpreted with caution. CLINICAL RELEVANCE: The finding suggests that green tea catechin may be a topical adjunct to SRP without negative side effects.


Assuntos
Periodontite Crônica/terapia , Raspagem Dentária , Aplainamento Radicular , Chá , Humanos , Índice Periodontal
3.
Eur J Dent Educ ; 23(1): 1-7, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29696742

RESUMO

BACKGROUND: The Bologna reform resulted in a drastic restructuring of pre-clinical training courses at the University of Zurich. The aim of this study was to assess student pre-clinical scaling/root planning skills after just 8.5 hours of manual training. MATERIAL AND METHODS: Three consecutive classes of dental students (n = 41; n = 34; n = 48) were tasked with removing lacquer concrement from the maxillary left canine on a typodont using Gracey and universal (Deppeler M23A) curettes. At baseline (prior to instruction), a timed five-minute session of scaling/root planning was undertaken. The second scaling/root planning session was held immediately following training. Eight experienced dental hygienists and eight lay people served as positive and negative controls, using the same instruments and time limit, respectively. Instrumented teeth were collected, scanned and planimetrically analysed for the percentage of tooth surface cleaned. Statistical analyses were performed to assess the dental students' improvement after the training (Wilcoxon signed-rank test) and to compare it to that of laypeople and dental hygienists (Kruskal-Wallis rank sum test followed by Conover's post hoc test). RESULTS: At baseline, the dental students' mean scaling scores of the cleaned surfaces were not significantly different than those of laypeople (29.8%, 31.0%, 42% vs 27.9%). However, after 8.5 hours of manual training, the students' ability to clean the maxillary tooth improved significantly and they achieved mean removal values of 61.7%, 79.5% and 76% compared to the 67.4% (P < .001) of the experienced dental hygienists (Tables Tables  and ). There were no statistically significant differences between the scores achieved by students after training and those achieved by experienced dental hygienists. CONCLUSION: A shortened pre-clinical training time was sufficient for students to acquire the basic scaling/root planning skills needed in preparation for clinical training. Further research is needed to identify ways to help students consistently reach highest skill levels.


Assuntos
Competência Clínica , Raspagem Dentária , Educação em Odontologia/métodos , Periodontia/educação , Aplainamento Radicular , Estudantes de Odontologia , Humanos , Fatores de Tempo
4.
Clin Oral Investig ; 22(3): 1385-1393, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29019080

RESUMO

OBJECTIVES: The aim of this paper is to evaluate the influence of the internal anatomy on the leakage of root canals filled with the thermoplastic technique. MATERIALS AND METHODS: The upper central incisors (UCI) and mesial roots of the lower molars (MRLM) (n = 12 each) were tested regarding leakage using the gas-enhanced permeation test (GEPT) after root filling. The quality of the root fillings was assessed using micro-computed tomography (µCT) by superimposing scans before and after treatment to calculate unfilled volume. The calculated void volume was compared between the groups and correlated to the measured leakage values. Data were analyzed using t test and Pearson's correlation tests (p < 0.05). RESULTS: The mean void volume did not differ between UCI and MRLM (13.7 ± 6.2% vs. 14.2 ± 6.8%, respectively). However, significantly more leakage was evident in the MRLM (p < 0.001). While the leakage correlated highly to the void volume in the MRLM group (R 2 = 0.981, p < 0.001), no correlation was found in UCI (R 2 = 0.467, p = 0.126). CONCLUSION: MRLM showed higher leakage values, which correlated to the void volume in the root canal fillings. CLINICAL RELEVANCE: Care should always be taken while doing root canal treatments, but attention to teeth with known/expected complex root canal anatomy should be considered.


Assuntos
Infiltração Dentária , Incisivo/anatomia & histologia , Dente Molar/anatomia & histologia , Materiais Restauradores do Canal Radicular , Preparo de Canal Radicular/métodos , Humanos , Técnicas In Vitro , Incisivo/diagnóstico por imagem , Incisivo/cirurgia , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Microtomografia por Raio-X
5.
BMC Oral Health ; 18(1): 62, 2018 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-29625605

RESUMO

BACKGROUND: For periodontal treatment, the full mouth disinfection approach suggests disinfection of oral soft tissues, such as tongue and tonsils concomitant to scaling and root planning since patients might benefit from treatment of these oral niches either. Periodontopathogenes in tonsillar tissue support this hypothesis. This prospective controlled clinical study investigated the change in the oral flora of patients who underwent tonsillectomy. Pockets were tested for eleven bacterial species before and six weeks after the surgical intervention. METHODS: Fifty generally healthy adults were included in this study. The test group consisted of 25 patients with tonsillectomy. The control group included 25 patients with otorhinolarynologic surgery without involvement of the oral cavity. Clinical parameters such as probing pocket depth, bleeding-on-probing index and plaque index were registered the evening before surgery. Also bacterial samples from the gingival sulcus and dorsum linguae were taken, and an additional sample from the removed tonsils in the test group. Six weeks after the intervention microbial samples of pockets and tongue were taken again. Data were tested for significant differences using Wilcoxon rank and Whitney-u-test. RESULTS: No relevant intra- or intergroup differences were found for the change of the eleven investigated species. CONCLUSION: Based on the results of the present study, tonsillectomy does not seem to have an immediate relevant effect on the bacterial flora of tongue or periodontium. This study design was approved by the ethical committee of Zurich (KEK-ZH-Nr.2013-0419). TRIAL REGISTRATION: The trial was retrospectively registered in the German Clinical Trials Register ( DRK00014077 ) on February 20, 2018.


Assuntos
Microbiota , Bolsa Periodontal/microbiologia , Periodonto/microbiologia , Língua/microbiologia , Tonsilectomia/efeitos adversos , Adulto , Estudos de Casos e Controles , Índice de Placa Dentária , Feminino , Humanos , Masculino , Índice Periodontal , Estudos Prospectivos , Adulto Jovem
6.
Int Endod J ; 49(6): 591-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26077169

RESUMO

AIM: To assess two contemporary rotary instrumenting systems subjectively and objectively in a pre-clinical student course setting. METHODOLOGY: Undergraduate dental students (n = 44) prepared mesiolingual canals of 3D-printed mandibular molar replicas (RepliDens, Zurich, Switzerland). The HyFlex and BioRace rotary systems, both previously unknown to the students, were used according to the manufacturers' guidelines after a short theoretical introduction. For comparison, a first-generation rotary system (ProFile .04), which the students knew from their previous education, was then used in a third RepliDens. Questionnaires were issued to note subjective experiences immediately after instrumentation. Objectively, time to instrument to size 40, .04 taper and shaping outcomes were analysed. Categorical data were compared using chi-square and Fisher's exact tests, numerical data according to goodness of fit to the normal distribution, P < 0.05. RESULTS: Subjectively, the students liked the file size and sequence designation in the BioRace system significantly (P < 0.05) better than in the HyFlex counterpart, whilst they found better controllability with the HyFlex (P < 0.05), and reported no difference in cutting efficiency. They preferred both systems to the ProFile. Objectively, canal transportation was significantly less with the HyFlex (and the ProFile) systems compared to BioRace (P < 0.05). Both systems under investigation were statistically similar in terms of file fractures (nil), length control, and instrumentation time, which was considerably faster than with the ProFile control system. CONCLUSIONS: HyFlex and BioRace had perceived and quantifiable strengths and weaknesses. Both systems were equally liked by the students and preferred over the ProFile first-generation rotary system.


Assuntos
Instrumentos Odontológicos , Educação em Odontologia/métodos , Preparo de Canal Radicular/instrumentação , Adulto , Feminino , Humanos , Masculino , Estudantes de Odontologia , Inquéritos e Questionários , Adulto Jovem
7.
Clin Oral Investig ; 20(4): 721-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26250794

RESUMO

OBJECTIVES: The aim of this study was to retrospectively analyze the influence of a prophylaxis protocol of head and neck tumor (HNT) patients during and after intensity-modulated radiotherapy (IMRT). MATERIAL AND METHOD: In this 5-year retrospective study (2009-2013), 70 (m 55, f 15; age range 28-8 years; median 58.7 years) out of 248 HNT patients of the Clinic of Cranio-Maxillofacial and Oral Surgery at the University of Zurich, Switzerland, fulfilled the inclusion criteria. Parameters of investigation were the salivary flow rates, possible dental foci and the dental status, oral side effects of radiotherapy, the prophylaxis protocol, and patient's compliance to this protocol. The following time points before during and after IMRT (6 weeks) were analyzed: prior to IMRT, 2-4 weeks, 6 weeks and 3, 6, and 12 months after the onset of radiotherapy. RESULT: Unstimulated salivary flow rate, pH value of unstimulated salivary, and stimulated salivary flow rate showed a significant reduction over time (p < 0.001). One year after IMRT, both unstimulated and stimulated salivary flow showed a statistically significant lower salivary flow. The number of caries-affected sites per patient was significantly higher for patients with low compliance to the prophylaxis protocol (mean: low compliance 1.36, high compliance 0.26). Almost 75% of the evaluated patients suffered immediate gustatory change, and 47.1% showed signs of radiostomatitis through IMRT. CONCLUSIONS: High compliance to the prophylaxis protocol during and after radiotherapy is a key factor for the reduction of radiation side effects on dental hard tissue. CLINICAL RELEVANCE: High compliance to a monitored prophylaxis program is crucial for patients after head and neck surgery.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia de Intensidade Modulada , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Suíça , Xerostomia/etiologia
8.
Clin Oral Investig ; 20(8): 1935-1942, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26661895

RESUMO

OBJECTIVES: The objective of the present study is to assess the potential of bull and boar spermatozoa and fluorescent beads to be used as a surrogate cell model to determine the cell occlusive potential in vitro using membranes of standardized porosities. MATERIALS AND METHODS: A two-chamber model system consisting of upper and lower chambers, which could be separated by membranes, was constructed. Isopore polycarbonate membranes with different standardized pore diameters were used to assess the mobile cellular penetration behavior of spermatozoa or the more passive non-cellular permeability of fluorescent particles (beads) of different diameter and color. In a first experiment, spermatozoa were placed in the lower chamber, whereas semen extender only was placed in the upper chamber. After 10 min of incubation at 37 °C, the sperm number was assessed in the latter. In a second experiment, a bead solution was drawn through resorbable collagen membranes from the upper into the lower chamber by vacuum using a syringe and bead number and size was analyzed by flow cytometry. All experiments were carried out in triplicates. A non-porous polyester membrane was used as negative control to assess the overall tightness of the setup. RESULTS: Boar and bull spermatozoa had average cell body lengths and widths of 9 × 5 µm and were unable to pass through pores ≤2 µm, whereas they were detectable at pore sizes ≥3 µm. Their number increased with increasing pore diameters, i.e., from minimal concentrations of 0.1 × 106/ml for boar and 0.5 × 106/ml for bull spermatozoa at 3 µm to maximal concentrations of 2.1 × 106/ml for boar and 13.1 × 106/ml for bull spermatozoa at 8 µm. The fluorescent beads followed the expected pattern of permeability reliably correlating bead and pore diameter. CONCLUSIONS: Within the limitations of this laboratory study and the xenogeneic cell surrogate material, the model allows to easily assess cell and particle penetration through porous structures like membranes. We hope to further assess, improve, and validate this model, which we aim to use for the screening of dental membranes after being exposed to different degradation methods. CLINICAL RELEVANCE: Convenient and rapid test procedures to evaluate membranes for regenerative procedures are still warranted.


Assuntos
Membranas Artificiais , Espermatozoides/ultraestrutura , Animais , Bovinos , Sobrevivência Celular , Citometria de Fluxo , Fluorescência , Técnicas In Vitro , Masculino , Microscopia Eletrônica de Varredura , Porosidade , Suínos
9.
Int Endod J ; 48(5): 435-40, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24916092

RESUMO

AIM: To monitor chlorine consumption from nonagitated aqueous sodium hypochlorite (NaOCl) solutions in human root canals using a recently developed assay, which can determine the order of magnitude of available chlorine in small volumes of liquid. METHODOLOGY: The root canals of 80 extracted single-rooted human teeth were instrumented to ProTaper Universal F4 and irrigated using 1% NaOCl. Subsequently, canals were irrigated with copious amounts of deionized water to rinse out the residual chlorine. Subsequently, the teeth were sealed externally and placed in a water bath of 37 °C. Root canals were filled with NaOCl of 1%, 2.75%, 5.5%, or distilled water for 1, 10, 100 or 1000 min (n = 5 teeth per solution and time). Consumption of chlorine was measured using paper points pre-impregnated with 15% potassium iodide. Colour change of the paper points was determined photo-electronically, assessing their red value after absorbing solutions from root canals. Measurements were compared to a standard series of NaOCl down to 0.001% (n = 5 paper points per concentration). RESULTS: Red values of the paper points inserted into the root canal were affected by initial NaOCl concentration and time (two-way anova, P < 0.05). If NaOCl concentrations above 0.1% are considered to be clinically relevant, then 5.5% NaOCl retained its activity in the root canal for more than 100 min, whereas 1% NaOCl lost its activity between 10 and 100 min. CONCLUSIONS: Nonagitated NaOCl solutions can remain biologically active in human root canals for extended time periods.


Assuntos
Cloro/análise , Cavidade Pulpar/química , Irrigantes do Canal Radicular/análise , Hipoclorito de Sódio/análise , Humanos , Técnicas In Vitro , Irrigantes do Canal Radicular/administração & dosagem , Hipoclorito de Sódio/administração & dosagem
10.
Clin Oral Investig ; 19(4): 831-40, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25138041

RESUMO

OBJECTIVES: To evaluate the influence of irradiation time on degree of conversion (DC) and microhardness of high-viscosity bulk-fill resin composites in depths up to 6 mm. MATERIALS AND METHODS: Four bulk-fill materials (Tetric EvoCeram Bulk Fill--TECBF; x-tra fil--XF; QuixFil--QF; SonicFill-SF) and one conventional nano-hybrid resin composite (Tetric EvoCeram--TEC) were irradiated for 10, 20, or 30 s at 1,170 mW/cm(2). DC and Knoop microhardness (KHN) were recorded after 24-h dark storage at five depths: 0.1, 2, 4, 5, and 6 mm. Data were statistically analyzed using ANOVA and Bonferroni's post-hoc test (α = 0.05). RESULTS: With increasing bulk thickness, DC and KHN significantly decreased for TEC. TECBF and SF showed a significant decrease in DC and KHN at 4-mm depth after 10-s irradiation, but no decrease in DC after 30-s irradiation (p > 0.05). XF and QF demonstrated no significant DC decrease at depths up to 6 mm after irradiation of at least 20 s. At 4-mm depth, all materials tested achieved at least 80 % of their maximum DC value, irrespective of irradiation time. However, at the same depth (4 mm), only XF and QF irradiated for 30 s achieved at least 80 % of their maximum KHN value. CONCLUSIONS: Regarding DC, the tested bulk-fill resin composites can be safely used up to at least 4-mm incremental thickness. However, with respect to hardness, only XF and QF achieved acceptable results at 4-mm depth with 30 s of irradiation. CLINICAL RELEVANCE: Minimum irradiation times stated by the manufacturers cannot be recommended for placement of high-viscosity bulk-fill materials in 4-mm increments.


Assuntos
Resinas Compostas/química , Resinas Compostas/efeitos da radiação , Dureza , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo , Viscosidade
11.
Int J Dent Hyg ; 13(4): 246-53, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25421848

RESUMO

OBJECTIVE: To evaluate a novel device for its efficacy in removing experimental biofilm from root surfaces and its potential for concomitantly removing/roughening the surface substance. METHODS AND MATERIALS: A novel acrylic rotary device (biofilm remover, BR) was tested in vitro in three experiments: surface loss, surface roughness [positive controls: Perioset (PS) and Proxoshape (PR)] and biofilm removal [positive controls: ultrasonic (US) and PS]. Surface loss/surface roughness was evaluated for dentin samples instrumented for three 20 s periods. The calcium removed during instrumentation was analysed after each interval and cumulatively, using atomic absorption spectrophotometry (AAS). Surface roughness was measured using profilometric analysis. Biofilm removal was evaluated on dentin specimens coated with a 64.5 h 6-species in vitro formed biofilm, after one 20 s treatment. Surface loss was analysed using anova with Scheffé post hoc test, and surface roughness/biofilm removal was analysed using Mann-Whitney test (all P ≤ 0.05). RESULTS: Significantly less substance loss [µg (± 1 SD)] was observed with the novel device at all time points, both interval and cumulative (1.0 (± 0.5) versus 9.3 (± 3.2) PS and 9.9 (± 1.9) PR at 60 s). Surface roughness [µm (95% CI)] was significantly lower for BR than for PS and PR [0.00 (-0.01, 0.08) 0.20 (0.16, 0.27) and 0.21 (0.19, 0.24) at 60 s]. Significantly less biofilm bacteria remained after treatment with both BR 4.5 (-0.1, 16.2) and US 1.9 (-0.2, 14.3), compared to PS 52 (27.9, 82.1). CONCLUSIONS: The novel biofilm remover was less damaging to dentin surfaces, while removing biofilm at least as effectively as devices used in this study.


Assuntos
Biofilmes , Dentina/química , Higienizadores de Dentadura/química , Aplainamento Radicular/instrumentação , Raiz Dentária/química , Dentina/ultraestrutura , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Raiz Dentária/ultraestrutura , Ultrassom
12.
Caries Res ; 48(1): 45-50, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24247975

RESUMO

AIM: Determination of the potential of cerium chloride to reduce artificial carious mineral loss and lesion depth progression. METHODS: A total of 160 enamel samples were prepared from 40 bovine lower central incisors. Crowns were sectioned into four pieces, embedded in acrylic resin, ground flat and allocated to eight groups (S1-S4 and D1-D4; n = 20). Specimens of groups D1-D4 were stored (for 7 days) in a demineralizing buffer solution to induce caries-like lesions. Afterwards, samples were treated for 30 s with one of the following solutions: placebo (S1 and D1), amine fluoride (S2 and D2), cerium chloride (S3 and D3) and a combination of fluoride and cerium chloride (S4 and D4). After another 7 (D1-D4) or 14 (S1-S4) days in demineralizing buffer solution, integrated mineral loss and lesion depth were determined by transversal microradiography and compared by Scheffé's post hoc tests. RESULTS: In groups S1-S4, the highest values for integrated mineral loss and lesion depth were observed for group S1 (placebo), the lowest values for group S4. The results in groups S2-S4 were not significantly different. In groups D1-D4, the highest values for integrated mineral loss and lesion depth were observed for group D1 (placebo), the lowest values in groups D3 and D4. In group D2, integrated mineral loss and lesion depth were significantly lower as compared to D1, but significantly higher compared to groups D3 and D4. CONCLUSION: Cerium chloride and its combination with fluoride are able to significantly reduce carious mineral loss and the progression of lesion depth.


Assuntos
Cariostáticos/farmacologia , Cério/farmacologia , Esmalte Dentário/efeitos dos fármacos , Desmineralização do Dente/prevenção & controle , Animais , Bovinos , Diaminas/farmacologia , Progressão da Doença , Combinação de Medicamentos , Fluoretos/farmacologia , Microrradiografia , Minerais/análise , Placebos , Fatores de Tempo , Desmineralização do Dente/metabolismo
13.
Caries Res ; 48(2): 154-62, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24401733

RESUMO

This study aimed to analyse the impact of brushing on the protective effect of different fluoride solutions on enamel and dentin erosion. Bovine enamel and dentin specimens were rinsed once with TiF4, AmF, SnF2 (0.5 M F, 2 min) or water (control). Specimens were either left unbrushed or brushed with 10, 20, 50, 100 or 500 brushing strokes in an automatic brushing machine (2 N, non-fluoridated toothpaste slurry). Ten specimens per group were eroded with hydrochloric acid (HCl) (pH 2.3) for 60 s, and calcium release into the acid was determined by atomic absorption spectroscopy. Additionally, enamel and dentin surfaces were analysed by X-ray energy-dispersive spectroscopy (EDS) (n = 6/group) and scanning electron microscopy (SEM) (n = 2/group) before brushing and after 500 brushing strokes. Statistical analysis (p < 0.05) was performed by three- and one-way ANOVA (calcium release) or repeated measures ANOVA (EDS). TiF4, AmF and SnF2 reduced the erosive calcium loss in unbrushed specimens to 58-67% (enamel) and 23-31% (dentin) of control. Calcium release increased with increasing brushing strokes prior to erosion and amounted to 70-88% (enamel) and 45-78% (dentin) of control after 500 brushing strokes. Brushing reduced the surface concentration of fluoride (AmF), tin (SnF2) and titanium (TiF4). SEM revealed that surface precipitates were affected by long-term brushing. Brushing reduced the protective potential of TiF4, AmF and SnF2 solutions. However, considering a small number of brushing strokes, the protective effect of fluoride solutions is only slightly affected by brushing abrasion.


Assuntos
Fluoretos/uso terapêutico , Substâncias Protetoras/uso terapêutico , Abrasão Dentária/prevenção & controle , Erosão Dentária/prevenção & controle , Escovação Dentária/efeitos adversos , Aminas/uso terapêutico , Animais , Cálcio/análise , Fluoreto de Cálcio/análise , Bovinos , Precipitação Química , Esmalte Dentário/química , Esmalte Dentário/efeitos dos fármacos , Dentina/química , Dentina/efeitos dos fármacos , Ácido Clorídrico/efeitos adversos , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Espectrofotometria Atômica , Fluoretos de Estanho/uso terapêutico , Titânio/uso terapêutico
14.
Clin Oral Investig ; 18(2): 579-87, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23636610

RESUMO

OBJECTIVES: This study aims to evaluate the effect of a minimally invasive mesial-occlusal-distal (mod) preparation on the marginal adaptation of ceramic and composite inlays with the aim of saving sound dental substance. MATERIALS AND METHODS: Class II mod cavities were prepared in 50 extracted human molars and randomly allocated to five groups (n = 10). In all groups, the mesial-proximal box margins were located in the dentin, 1 mm below the cementoenamel junction (CEJ), while the distal box margins were 1 mm above the CEJ. In groups A and B, conventional standard preparations with a divergent angle of α = 6° were prepared. In groups C, D, and E, minimally invasive standard preparations with a convergent angle of α = 10° were prepared. In groups A and D, composite inlays and, in groups B and C, ceramic inlays were fabricated (chairside economical restoration of esthetic ceramics (CEREC)) and adhesively inserted. In group E, a direct composite filling using the incremental technique was placed. Replicas were taken before and after thermomechanical loading (1,200,000 cycles, 50/5 °C, max. load 49 N). Marginal integrity (tooth-luting composite, luting composite-inlay) was evaluated by scanning electron microscopy (× 200). The percentage of continuous margins in the different locations was compared between and within groups before and after cycling, using ANOVA and Scheffé post hoc test. RESULTS: After the thermomechanical loading, no significant differences were observed between the different groups with respect to the interface of luting composite-inlay. At the interface of tooth-luting composite for preparations involving the dentin, groups A and B behaved significantly better compared to the control group E, which in turn were not different to groups C and D. CONCLUSION: Composite and ceramic inlays inserted in minimally invasive prepared mod cavities result in margins not different from those of inlays placed in conventional mod preparations. Direct composite filling margins, however, were inferior to those attained by conventional indirect restorations. CLINICAL RELEVANCE: Minimally invasive preparations for mod inlays with undercuts show marginal adaptation equal to that of conventional inlay preparation design.


Assuntos
Cerâmica , Resinas Compostas , Cárie Dentária/patologia , Cimentos Dentários , Humanos , Microscopia Eletrônica de Varredura
15.
Clin Oral Investig ; 17(2): 595-600, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22526895

RESUMO

OBJECTIVE: The aim of the study was to evaluate the impact of flow velocity under laminar flow conditions of different acidic solutions on enamel erosion. MATERIAL AND METHODS: A total of 240 bovine enamel specimens were prepared and allocated to 30 groups (n = 8 each). Samples of 18 groups were superfused in a flow chamber system with laminar flow behavior using 1 ml of citric acid or hydrochloric acid (HCl) of pH 2.0, 2.6 or 3.0. Flow rates in the sample chamber were adjusted to 10, 60 or 100 µl/min. To simulate turbulent flow behavior, samples of six groups were immersed in 1 ml of the respective solution, which was vortexed (15 min, 600 rpm). For simulating non-agitated conditions, specimens of the remaining six groups were immersed in 1 ml of the respective solution without stirring. Calcium in the solutions, released from the enamel samples, was determined using Arsenazo III method. RESULTS: For acidic solutions of pH 2.6 and 3.0, erosive potential of citric acid was equivalent to that of HCl at a flow of 100 µl/min. The same observation was made for the samples subjected to turbulent conditions at pH 3. At all other conditions, citric acid induced a significantly higher calcium loss than HCl. CONCLUSION: It is concluded that under slow laminar flow conditions, flow rate variations lead to higher erosive impact of citric acid compared to hydrochloric acid at pH 2.0, but not at pH ≥ 2.6 and increasing laminar flow or turbulent conditions. CLINICAL RELEVANCE: Erosive enamel dissolution under laminar flow conditions is a complex issue influenced by flow rate and acidic substrate.


Assuntos
Cálcio/análise , Ácido Cítrico/farmacologia , Esmalte Dentário/efeitos dos fármacos , Ácido Clorídrico/farmacologia , Erosão Dentária/induzido quimicamente , Animais , Arsenazo III , Bovinos , Esmalte Dentário/química , Hidrodinâmica , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Distribuição Aleatória , Reologia , Fatores de Tempo , Erosão Dentária/metabolismo
16.
Acta Odontol Scand ; 71(2): 317-24, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23004362

RESUMO

PURPOSE: Evaluating the effect of a proximal margin elevation technique on marginal adaptation of ceramic inlays. METHODS: Class II MOD-cavities were prepared in 40 human molars and randomly distributed to four groups (n = 10). In group EN (positive control) proximal margins were located in enamel, 1 mm above the cementoenamel junction, while 2 mm below in groups DE-1In, DE-2In and DE. The groups DE-1In, DE-2In and DE simulated subgingival location of the cervical margin. In group DE-1In one 3 mm and in group DE-2In two 1.5 mm composite layers (Tetric) were placed for margin elevation of the proximal cavities using Syntac classic as an adhesive. The proximal cavities of group DE remained untreated and served as a negative control. In all groups, ceramic inlays (Cerec 3D) were adhesively inserted. Replicas were taken before and after thermomechanical loading (1.200.000 cycles, 50/5°C, max. load 49 N). Marginal integrity (tooth-composite, composite-inlay) was evaluated with scanning electron microscopy (200×). Percentage of continuous margin (% of total proximal margin length) was compared between groups before and after cycling using ANOVA and Scheffé post-hoc test. RESULTS: After thermomechanical loading, no significant differences were observed between the different groups with respect to the interface composite-inlay and tooth-composite with margins in dentin. The interface tooth-composite in enamel of group EN was significantly better compared to group DE-2In, which was not different to the negative control group DE and DE-1In. CONCLUSION: Margin elevation technique by placement of a composite filling in the proximal box before insertion of a ceramic inlay results in marginal integrities not different from margins of ceramic inlays placed in dentin.


Assuntos
Cerâmica , Restaurações Intracoronárias , Fenômenos Biomecânicos , Humanos
17.
Eur Arch Paediatr Dent ; 24(1): 55-61, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36171525

RESUMO

PURPOSE: To evaluate and compare the wear of selected resin-based fissure sealants with different compositions properties under erosive, abrasive, and erosive/abrasive conditions. METHODS: Forty-five samples of the following resin-based fissure sealants were prepared: Fissurit (fluoride free), Fissurit F (with fluoride), Fissurit FX (55 wt.% filler content), Grandio Seal (70 wt.% nano-filler content) and bovine enamel. Fifteen samples from each material were randomly allocated into three groups according to the wear condition they would be subjected to as follows: erosive condition (citric acid, 1 min, pH 2.3), abrasive condition (120 brushing strokes at 2 N, toothpaste slurry RDA value = 69), and erosive/abrasive condition (combination of both). The wear challenges were repeated six times each day for 10 days. The material wear was measured using a stylus profilometer. Kruskal-Wallis and Conover's test was applied to compare the resulting material wear between the groups. RESULTS: Under erosive conditions, Grandio Seal and Fissurit FX showed statistically significantly the least material wear. Under abrasive and erosive/abrasive conditions, Grandio Seal showed statistically significantly the least material wear. Fissurit F showed statistically significantly the highest material wear under abrasive and erosive/abrasive conditions, after dental enamel (p < 0.05). CONCLUSION: Higher filler content in sealants leads to better wear resistance. Incorporating fluoride into sealants seems to reduce their wear resistance at similar filler contents.


Assuntos
Metacrilatos , Selantes de Fossas e Fissuras , Animais , Bovinos , Ácido Cítrico , Fluoretos
18.
Oper Dent ; 48(3): E71-E80, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37079917

RESUMO

OBJECTIVE: The aim of this study was to compare the clinical efficacy of at-home, in-office, and combined bleaching regimens. METHODS: Forty-eight participants were recruited and randomly divided into four groups based on the bleaching regimen (n=12) as follows: 1) at-home bleaching using 10% carbamide peroxide (Opalescence PF 10%, Ultradent) for 14 days (HB); 2) two sessions of in-office bleaching using 40% hydrogen peroxide (Opalescence BOOST PF 40%, Ultradent) with a one-week interval (OB); 3) one session of in-office bleaching followed by at-home bleaching for seven days (OHB); and 4) at-home bleaching for seven days followed by one session of in-office bleaching (HOB). Tooth color was measured using a spectrophotometer (Easyshade, Vita ZahnFabrik) at baseline (T0), day 8 (T1), day 15 (T2), and day 43 (T3, four weeks after the end of the bleaching treatment). The color data were calculated using the CIEDE2000 (ΔE00) and whiteness index for dentistry (WID) formulas. Tooth sensitivity (TS) was recorded using a visual analogue scale (VAS) for 16 days. Data were analyzed by one-way analysis of variance (ANOVA) and the Wilcoxon signed-rank test (α=0.05). RESULTS: All bleaching regimens resulted in a significant increase in WID values (all p<0.05), while no significant differences in WID and ΔWID values were found among the different groups at each time point (all p>0.05). Significant differences in ΔE00 values were observed between T1 and T3 for all groups (all p<0.05), while no significant differences in ΔE00 values were found among the different groups at any time point (all p>0.05). Significantly lower TS values were observed in the HB group than in the OB and HOB groups (p=0.006 and p=0.001, respectively). CONCLUSIONS: All bleaching regimens resulted in great color improvement, and different regimens led to similar color changes at any of the evaluation time points. The sequence of treatments applying in-office bleaching or at-home bleaching did not affect the bleaching efficacy. The in-office bleaching and combined bleaching regimens yielded a higher intensity of TS than did at-home bleaching.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Clareamento Dental/métodos , Cor , Peróxido de Hidrogênio/uso terapêutico , Peróxido de Carbamida/uso terapêutico , Resultado do Tratamento , Clareadores Dentários/uso terapêutico
19.
J Dent Res ; 102(9): 1015-1021, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37387401

RESUMO

The aim of the study was to compare the clinical and radiographic outcomes of short dental implants (6-mm test group, TG) to longer implants (10-mm control group, CG) with single crown restorations after 10 y of loading. Patients requiring single-tooth replacement in the posterior jaws were randomly assigned to TG or CG. Implants were loaded with screw-retained single crowns after a healing period of 10 wk. Follow-up appointments were scheduled yearly and comprised patient-adapted oral hygiene reinstructions and polishing of all teeth and implants. After 10 y, clinical and radiographical parameters were assessed again. Out of initially 94 patients (47 in TG and CG, each), 70 (36 TG and 34 CG) could be reassessed. Survival rates accounted for 85.7% (TG) and 97.1% (CG), without significant intergroup difference (P = 0.072). All but 1 lost implant had been located in the lower jaw. These implants were not lost due to peri-implantitis but due to a late loss of osseointegration without signs of inflammation and with actually stable marginal bone levels (MBLs) over the investigation period. In general, MBLs were stable with medians (interquartile ranges) of 0.13 (0.78) mm and 0.08 (1.2) mm, for TG and CG, without significant intergroup differences. Crown-to-implant ratio showed a highly significant intergroup difference of 1.06 ± 0.18 mm and 0.73 ± 0.17 mm (P < 0.001). Few technical complications (i.e., screw loosening or chipping) were registered during the investigation period. In conclusion, given stringent professional maintenance, short dental implants with single-crown restorations show a slightly worse but statistically not different survival rate after 10 y, especially in the lower jaw, but can still be considered a valuable alternative, especially when vertical bone dimensions are limited (German Clinical Trials Registry: DRKS00006290).


Assuntos
Perda do Osso Alveolar , Implantes Dentários para Um Único Dente , Implantes Dentários , Peri-Implantite , Humanos , Coroas , Osseointegração , Seguimentos , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Resultado do Tratamento , Perda do Osso Alveolar/diagnóstico por imagem , Planejamento de Prótese Dentária
20.
Int Endod J ; 45(10): 942-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22506849

RESUMO

AIM: To investigate the discoloration potential of endodontic materials using a bovine tooth model. METHODOLOGY: Two hundred and 10 dentine-enamel cuboid blocks (10 × 10 × 3.5 mm) were prepared out of the middle thirds of bovine tooth crowns. Standardized cavities were prepared in the walls of the pulp chamber leaving 2 mm of enamel and dentine on the labial wall of the crown. The specimens were randomly assigned to 14 groups (n = 15). Endodontic materials were placed into the cavities as follows: group A: empty, group B: blood, group C: calcium hydroxide, group D: ApexCal, group E: Ultracal XS, group F: Ledermix, group G: triple antibiotic paste (3Mix), group H: grey MTA(GMTA), group I: GMTA + blood, group J: white MTA (WMTA), group K: WMTA + blood, group L: Portland cement (PC), group M: PC + blood and group N: AH Plus. The cavities were sealed with composite and stored in water. Standardized colour measurement (VITA Easyshade compact) was performed at the following intervals: prior to (T0) and after placement of the filling (T1), 1 week (T2), 1 month (T3), 3 months (T4), 6 months (T5) and after 1 year (T6). Colour change (ΔE) values were calculated. A two-way analysis of variance was used to assess significant differences between the endodontic materials. The mean values of all groups were compared using the Tukey multiple comparison test (α = 0.05). RESULTS: Significant differences were detected amongst the experimental groups after 12 months (P < 0.0001). The lowest colour change values were observed in the groups N (AH Plus, 3.2 ± 1.5), A (empty, 3.8 ± 1.4), L (PC, 4.1 ± 1.7), C (calcium hydroxide, 4.7 ± 1.5), E (Ultracal XS, 5.1 ± 1.9) and J (WMTA, 7.9 ± 6.7). The most discoloration was measured in groups G (3Mix, 66.2 ± 9.9) and F (Ledermix, 46.2 ± 11.6). PC showed the best colour stability amongst the Portland cement-based materials; however, when contaminated with blood (group M), a significantly higher ΔE value (13.6 ± 4.2) was detected (P = 0.032). CONCLUSION: Materials used in endodontics may stain teeth. Therefore, the choice of material should not rely solely on biological and functional criteria, but also take aesthetic considerations into account.


Assuntos
Materiais Restauradores do Canal Radicular/efeitos adversos , Coroa do Dente/efeitos dos fármacos , Descoloração de Dente/induzido quimicamente , Compostos de Alumínio/efeitos adversos , Análise de Variância , Animais , Antibacterianos/efeitos adversos , Compostos de Cálcio/efeitos adversos , Hidróxido de Cálcio/efeitos adversos , Bovinos , Demeclociclina/efeitos adversos , Cimentos Dentários/efeitos adversos , Combinação de Medicamentos , Resinas Epóxi/efeitos adversos , Óxidos/efeitos adversos , Distribuição Aleatória , Silicatos/efeitos adversos , Triancinolona Acetonida/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA