Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Endovasc Ther ; : 15266028231209247, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37933445

RESUMO

CLINICAL IMPACT: With endovascular therapy becoming the first-line treatment for symptomatic chronic mesenteric ischemia, acute pancreatitis within the context of abdominal ischemia-reperfusion injury may be seen more often in cross-sectional imaging following this kind of interventions and should therefore be kept in mind by the reading physician.

2.
BMC Med Imaging ; 22(1): 90, 2022 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-35578260

RESUMO

BACKGROUND: Endovascular revascularization has become the first-line treatment of chronic mesenteric ischemia (CMI). The qualitative visual analysis of digital subtraction angiography (DSA) is dependent on observer experience and prone to interpretation errors. We evaluate the feasibility of 2D-Perfusion Angiography (2D-PA) for objective, quantitative treatment response assessment in CMI. METHODS: 49 revascularizations in 39 patients with imaging based evidence of mesenteric vascular occlusive disease and clinical signs of CMI were included in this retrospective study. To assess perfusion changes by 2D-PA, DSA-series were post-processed using a dedicated, commercially available software. Regions of interest (ROI) were placed in the pre- and post-stenotic artery segment. In aorto-ostial disease, the inflow ROI was positioned at the mesenteric artery orifice. The ratios outflow to inflow ROI for peak density (PD), time to peak and area-under-the-curve (AUC) were computed and compared pre- and post-interventionally. We graded motion artifacts by means of a four-point scale. Feasibility of 2D-PA and changes of flow parameters were evaluated. RESULTS: Motion artifacts due to a mobile vessel location beneath the diaphragm or within the mesenteric root, branch vessel superimposition and inadequate contrast enhancement at the inflow ROI during manually conducted DSA-series via selective catheters owing to steep vessel angulation, necessitated exclusion of 26 measurements from quantitative flow evaluation. The feasibility rate was 47%. In 23 technically feasible assessments, PDoutflow/PDinflow increased by 65% (p < 0.001) and AUCoutflow/AUCinflow increased by 85% (p < 0.001). The time to peak density values in the outflow ROI accelerated only minimally without reaching statistical significance. Age, BMI, target vessel (celiac trunk, SMA or IMA), stenosis location (ostial or truncal), calcification severity, plaque composition or the presence of a complex stenosis did not reach statistical significance in their distribution among the feasible and non-feasible group (p > 0.05). CONCLUSIONS: Compared to other vascular territories and indications, the feasibility of 2D-PA in mesenteric revascularization for CMI was limited. Unfavorable anatomic conditions contributed to a high rate of inconclusive 2D-PA results.


Assuntos
Isquemia Mesentérica , Angiografia Digital/métodos , Doença Crônica , Constrição Patológica , Estudos de Viabilidade , Humanos , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/cirurgia , Perfusão , Estudos Retrospectivos , Resultado do Tratamento
3.
BMC Med Imaging ; 22(1): 19, 2022 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-35120493

RESUMO

BACKGROUND: To analyze the benefit of color-coded summation images in the assessment of target lumen perfusion in patients with aortic dissection and malperfusion syndrome before and after fluoroscopy-guided aortic fenestration. METHODS: Between December 2011 and April 2020 25 patients with Stanford type A (n = 13) or type B dissection (n = 12) and malperfusion syndromes were treated with fluoroscopy-guided fenestration of the dissection flap using a re-entry catheter. The procedure was technically successful in 100% of the cases and included additional iliofemoral stent implantation in four patients. Intraprocedural systolic blood pressure measurements for gradient evaluation were performed in 19 cases. Post-processed color-coded DSA images were obtained from all DSA series before and following fenestration. Differences in time to peak (dTTP) values in the compromised aortic lumen and transluminal systolic blood pressure gradients were analyzed retrospectively. Correlation analysis between dTTP and changes in blood pressure gradients was performed. RESULTS: Mean TTP prior to dissection flap fenestration was 6.85 ± 1.35 s. After fenestration, mean TTP decreased significantly to 4.96 ± 0.94 s (p < 0.001). Available systolic blood pressure gradients between the true and the false lumen were reduced by a median of 4.0 mmHg following fenestration (p = 0.031), with significant reductions in Stanford type B dissections (p = 0.013) and minor reductions in type A dissections (p = 0.530). A moderate correlation with no statistical significance was found between dTTP and the difference in systolic blood pressure (r = 0.226; p = 0.351). CONCLUSIONS: Hemodynamic parameters obtained from color-coded DSA confirmed a significant reduction of TTP values in the aortic target lumen in terms of an improved perfusion in the compromised aortic region. Color-coded DSA might thus be a suitable complementary tool in the assessment of complex vascular patterns prevailing in aortic dissections, especially when blood pressure measurements are not conclusive or feasible.


Assuntos
Angiografia Digital/métodos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares , Procedimentos Endovasculares/métodos , Feminino , Fluoroscopia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Acta Radiol ; 63(9): 1196-1204, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34323588

RESUMO

BACKGROUND: Despite improved shunt patency, transjugular intrahepatic portosystemic shunt (TIPS) occlusion remains a serious complication, and effective debulking of the existing tract is needed to restore sufficient blood flow. PURPOSE: To evaluate the technical and clinical success of percutaneous mechanical thrombectomy in restoring patency of acutely and chronically thrombosed covered TIPS using the Aspirex®S and Rotarex®S system. MATERIAL AND METHODS: We evaluated mechanical thrombectomy-assisted revisions in five patients between January 2012 and April 2021. Two patients had to be revised twice due to recurrent occlusion. We designated thrombosis within 10 days after shunt creation or revision as acute. Insidious deterioration of portal hypertension related symptoms for at least 6-8 weeks was recorded in chronic cases. We treated four acute and three chronic occlusions. After transjugular lesion crossing, we performed two mechanical thrombectomy device passages. If indicated, balloon dilatation, covered stent placement, or variceal embolization were added. RESULTS: The technical success rate was 100%. No procedure-related complications occurred. In one patient with acute decompensation of Budd-Chiari syndrome and acute-on-chronic liver failure, early re-thrombosis occurred twice with patency intervals of up to eight days. In contrast, stable patency was achieved in the other four patients with documented patency intervals of at least five months and improvement of portal hypertension-related symptoms, resulting in a patient based clinical success rate of 80%. CONCLUSION: In five patients, percutaneous mechanical thrombectomy assisted TIPS recanalization of four acute and three chronic occlusions proved to be technically feasible and safe with a high clinical success rate.


Assuntos
Hipertensão Portal , Derivação Portossistêmica Transjugular Intra-Hepática , Trombose , Estudos de Viabilidade , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Trombectomia/métodos , Trombose/complicações , Resultado do Tratamento
5.
Pediatr Radiol ; 52(8): 1550-1558, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35368211

RESUMO

BACKGROUND: Children with different underlying malignant diseases require long-term central venous access. As for port systems in a pectoral position, peripherally implanted port systems in the forearm revealed high levels of technical and clinical success in adult cohorts. OBJECTIVE: To investigate the technical and clinical outcomes of percutaneous central venous port implantation in the forearm in adolescents. MATERIALS AND METHODS: Between April 2010 and August 2020, 32 children ages 9 to 17 years with underlying malignancy received 35 totally implantable venous access ports (TIVAPs) in the forearm. All venous port systems were peripherally inserted under ultrasound guidance. Correct catheter placement was controlled by fluoroscopy. As primary endpoints, the technical success, rate of complications and catheter maintenance were analyzed. Secondary endpoints were the side of implantation, vein of catheter access, laboratory results on the day of the procedure, procedural radiation exposure, amount of contrast agent and reasons for port device removal. RESULTS: Percutaneous TIVAP placement under sonographic guidance was technically successful in 34 of 35 procedures (97.1%). Procedure-related complications did not occur. During the follow-up, 13,684 catheter days were analyzed, revealing 11 complications (0.8 per 1,000 catheter-duration days), Of these 11 complications, 7 were major and 10 occurred late. In seven cases, the port device had to be removed; removal-related complications did not occur. CONCLUSION: Peripheral TIVAP placement in the forearms of children is a feasible, effective and safe technique with good midterm outcome. As results are comparable with standard access routes, this technique may be offered as an alternative when intermittent venous access is required.


Assuntos
Cateterismo Venoso Central , Neoplasias , Dispositivos de Acesso Vascular , Adolescente , Adulto , Cateterismo Venoso Central/métodos , Cateteres de Demora , Criança , Antebraço/irrigação sanguínea , Antebraço/diagnóstico por imagem , Humanos , Estudos Retrospectivos
6.
BMC Med Imaging ; 21(1): 21, 2021 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-33568089

RESUMO

BACKGROUND: Endovascular therapy is the gold standard in patients with hemodynamic relevant renal artery stenosis (RAS) resistant to medical therapy. The severity grading of the stenosis as well as the result assessment after endovascular approach is predominantly based on visible estimations of the anatomic appearance. We aim to investigate the application of color-coded DSA parameters to gain hemodynamic information during endovascular renal artery interventions and for the assessment of the procedures´ technical success. METHODS: We retrospectively evaluated 32 patients who underwent endovascular renal artery revascularization and applied color-coded summation imaging on selected monochromatic DSA images. The differences in time to peak (dTTP) of contrast enhancement in predefined anatomical measuring points were analyzed. Furthermore, differences in systolic blood pressure values (SBP) and serum creatinine were obtained. The value of underlying diabetes mellitus as a predictor for clinical outcome was assessed. Correlation analysis between the patients´ gender as well as the presence of diabetes mellitus and dTTP was performed. RESULTS: Endovascular revascularization resulted in statistically significant improvement in 4/7 regions of interest. Highly significant improvement of perfusion in terms of shortened TTP values could be found at the segmental artery level and in the intrastenotical segment (p < 0.001), significant improvement prestenotical and in the apical renal parenchyma (p < 0.05). In the other anatomic regions, differences revealed not to be significant. Differences between SBP and serum creatinine levels before and after the procedure were significant (p = 0.004 and 0.0004). Patients´ gender as well as the presence of diabetes mellitus did not reveal to be predictors for the clinical success of the procedure. Furthermore, diabetes and gender did not show relevant correlation with dTTP in the parenchymal measuring points. CONCLUSIONS: The supplementary use of color-coding DSA and the data gained from parametric images may provide helpful information in the evaluation of the procedures´ technical success. The segmental artery might be a particularly suitable vascular territory for analyzing differences in blood flow characteristics. Further studies with larger cohorts are needed to further confirm the diagnostic value of this technique.


Assuntos
Angiografia Digital/métodos , Angioplastia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Cor , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução da Artéria Renal/fisiopatologia , Estudos Retrospectivos , Adulto Jovem
7.
Vasa ; 50(3): 193-201, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33140697

RESUMO

Background: Arterioureteral fistulas (AUFs) are severe pathologies of different origin and with increasing incidence frequently appear in patients with underlying extensive malignancy and after pelvic surgery. AUF therapy is challenging since symptoms are frequently non-specific and patients are often unsuitable surgical candidates due to comorbidities. Since experiences with endovascular treatment strategies are limited, the feasibility, effectiveness, and safety were evaluated in a consecutive case series. Patients and methods: A retrospective analysis of five patients with endovascular AUF exclusion was performed. Probable predisposing factors for an AUF included history of pelvic malignancy with oncologic surgery in four patients, radiotherapy in four patients, and indwelling ureteral stents in four patients. Clinical presentation, diagnostic management, and site of fistula were assessed. Furthermore, technical and clinical success as well as complications were evaluated. Results: All patients presented with gross haematuria. In four patients, haematuria occurred during endoscopic ureteral stent manipulation. Affected vessels were the internal pudendal artery in one, intrarenal segmental artery and external iliac artery in two, and internal iliac artery in another two patients. Treatment included coil embolisation (n = 2), plug embolisation (n = 3), particulate embolisation (n = 1), and covered stent implantation (n = 2). Technical success was achieved in all procedures. In two cases, re-intervention was necessary due to AUF recurrence, resulting in a clinical success rate of 60.0%. One major complication class D was documented. Conclusions: AUFs can be treated effectively and safely using endovascular techniques. Diagnostic and therapeutic management of this rare entity requires a high level of awareness for potential risk factors as well as an optimal multidisciplinary coordination.


Assuntos
Procedimentos Endovasculares , Doenças Ureterais , Fístula Urinária , Fístula Vascular , Procedimentos Endovasculares/efeitos adversos , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Estudos Retrospectivos , Stents , Resultado do Tratamento , Doenças Ureterais/diagnóstico por imagem , Doenças Ureterais/cirurgia , Fístula Urinária/diagnóstico por imagem , Fístula Urinária/etiologia , Fístula Urinária/cirurgia , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/cirurgia
8.
BMC Med Imaging ; 20(1): 67, 2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32552680

RESUMO

BACKGROUND: Percutaneous transluminal angioplasty (PTA) is increasingly requested in the therapy of peripheral arterial occlusive disease. The evaluation of the technical result after balloon angioplasty with regard to bailout stenting is highly dependent on the operators´ subjective assessment and mainly based on the monochromatic digital subtraction angiography (DSA) images. The aim of this study was to compare color-coded single image as a novel diagnostic tool with monochromatic DSA for the analysis of flow limitation and need for stent implantation after PTA of superficial femoral artery (SFA) stenoses. METHODS: During a period of 18 months, 213 SFA lesions were treated by PTA with a standard balloon in 170 patients, resulting in a total of 193 endovascular procedures. The median age of the patients was 77 years (range, 35-96 years). Median length of the treated lesions was 10.5 cm (range, 1.0-50 cm). Three interventional radiologists retrospectively evaluated the results of balloon angioplasty with monochromatic as well as post-processed color-coded DSA images for flow limitations to decide if subsequent stent implantation was necessary. Consensus reading of two experienced interventional radiologists 2 months after the initial review served as reference standard to perform a receiver operating characteristics (ROC) analysis. RESULTS: ROC analysis for readers A, B and C showed area under the curve (AUC) values of 0.797, 0.865 and 0.804 for color-coded DSA and AUC values of 0.792, 0.843 and 0.872 for monochromatic DSA: a significant advantage of color-coded over conventional monochromatic DSA was not found for readers A and B (p > 0.05). Results of reader C were significantly better in the assessment of monochromatic images (p = 0.023). Diagnostic confidence using color-coded images was slightly higher than in monochromatic images (κ = 0.486 vs. κ = 0.459). CONCLUSIONS: In this study, color coded DSA did not reveal to be superior to conventional monochromatic DSA when evaluating results of PTA and when deciding whether stent implantation is necessary or not. This technology, however, requires further experiences with special regard to homogeneously trained radiologists and to the time requirement.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/terapia , Artéria Femoral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão , Arteriopatias Oclusivas/diagnóstico por imagem , Cor , Feminino , Artéria Femoral/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Resultado do Tratamento
9.
J Mol Cell Cardiol ; 129: 13-26, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30771306

RESUMO

Cardiac functionality is dependent on a balanced protein turnover. Accordingly, regulated protein decay is critical to maintain cardiac function. Here we demonstrate that deficiency of SPRED2, an intracellular repressor of ERK-MAPK signaling markedly expressed in human heart, resulted in impaired autophagy, heart failure, and shortened lifespan. SPRED2-/- mice showed cardiomyocyte hypertrophy, cardiac fibrosis, impaired electrical excitability, and severe arrhythmias. Mechanistically, cardiomyocyte dysfunction resulted from ERK hyperactivation and dysregulated autophagy, observed as accumulation of vesicles, vacuolar structures, and degenerated mitochondria. The diminished autophagic flux in SPRED2-/- hearts was reflected by a reduced LC3-II/LC3-I ratio and by decreased Atg7, Atg4B and Atg16L expression. Furthermore, the autophagosomal adaptors p62/SQSTM1 and NBR1 and lysosomal Cathepsin D accumulated in SPRED2-/- hearts. In wild-type hearts, SPRED2 interacted physically with p62/SQSTM1, NBR1, and Cathepsin D, indicating that SPRED2 is required for autophagolysosome formation in regular autophagy. Restored inhibition of MAPK signaling by selumetinib led to an increase in autophagic flux in vivo. Therefore, our study identifies SPRED2 as a novel, indispensable regulator of cardiac autophagy. Vice versa, SPRED2 deficiency impairs autophagy, leading to cardiac dysfunction and life-threatening arrhythmias.


Assuntos
Arritmias Cardíacas/metabolismo , Autofagia , Mortalidade Prematura , Proteínas Repressoras/deficiência , Adulto , Aldosterona/farmacologia , Animais , Arritmias Cardíacas/complicações , Arritmias Cardíacas/patologia , Arritmias Cardíacas/fisiopatologia , Autofagossomos/metabolismo , Autofagossomos/ultraestrutura , Biomarcadores/metabolismo , Pressão Sanguínea , Cardiomegalia/complicações , Cardiomegalia/metabolismo , Cardiomegalia/patologia , Cardiomegalia/fisiopatologia , Catepsina D/metabolismo , Colágeno/metabolismo , Fenômenos Eletrofisiológicos , MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Sistema de Condução Cardíaco/fisiopatologia , Hemodinâmica , Humanos , Lisossomos/metabolismo , Lisossomos/ultraestrutura , Camundongos Endogâmicos C57BL , Camundongos Knockout , Miocárdio/metabolismo , Miocárdio/patologia , Miocárdio/ultraestrutura , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/ultraestrutura , Fosforilação/efeitos dos fármacos , Fosfotreonina/metabolismo , Proteínas Repressoras/metabolismo , Vacúolos/metabolismo , Vacúolos/ultraestrutura
12.
Invest Radiol ; 59(4): 320-327, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812470

RESUMO

BACKGROUND AND AIMS: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff. METHODS: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty. Radiation dose-equivalent CT angiographies (high-/medium-/low-dose: 10/5/3 mGy) with constant tube voltage of 120 kVp, matching iterative reconstruction algorithm levels, and convolution kernels were used both with PCD-CT and EID-CT. In-stent lumen visibility, luminal and in-stent attenuation as well as contrast-to-noise ratio (CNR) were assessed via region of interest and diameter measurements. Results were compared using analyses of variance and regression analyses. RESULTS: Maximum in-stent lumen visibility achieved with PCD-CT was 94.48% ± 2.62%. The PCD-CT protocol with the lowest lumen visibility (BV40: 78.93% ± 4.67%) performed equal to the EID-CT protocol with the best lumen visibility (BV59: 79.49% ± 2.64%, P > 0.999). Photon-counting detector CT yielded superior CNR compared with EID-CT regardless of kernel and dose level ( P < 0.001). Maximum CNR was 48.8 ± 17.4 in PCD-CT versus 31.28 ± 5.7 in EID-CT (both BV40, high-dose). The theoretical dose reduction potential of PCD-CT over EID-CT was established at 88% (BV40), 83% (BV48/49), and 73% (BV59/60), respectively. In-stent attenuation was not significantly different from luminal attenuation outside stents in any protocol. CONCLUSIONS: With superior lumen visibility and CNR, PCD-CT allowed for noticeable dose reduction over EID-CT while maintaining image quality in a continuously perfused human cadaveric model.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Stents , Cadáver
13.
Acad Radiol ; 31(7): 2973-2986, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38403477

RESUMO

RATIONALE AND OBJECTIVES: This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS: In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed. RESULTS: The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56. CONCLUSION: In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.


Assuntos
Angiografia Digital , Angiografia por Tomografia Computadorizada , Doença Arterial Periférica , Sensibilidade e Especificidade , Humanos , Angiografia Digital/métodos , Feminino , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/métodos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Fótons , Adulto
14.
PLoS One ; 19(2): e0297800, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38330071

RESUMO

PURPOSE: The aim of this study was to evaluate the usability of a recently developed extracorporeally-perfused cadaver model for training the angiographic management of acute arterial diseases and periprocedural complications that may occur during endovascular therapy of the lower extremity arterial runoff. MATERIALS AND METHODS: Continuous extracorporeal perfusion was established in three fresh-frozen body donors via inguinal and infragenicular access. Using digital subtraction angiography for guidance, both arterial embolization (e.g., embolization using coils, vascular plugs, particles, and liquid embolic agents) and endovascular recanalization procedures (e.g., manual aspiration or balloon-assisted embolectomy) as well as various embolism protection devices were tested. Furthermore, the management of complications during percutaneous transluminal angioplasty, such as vessel dissection and rupture, were exercised by implantation of endovascular dissection repair system or covered stents. Interventions were performed by two board-certified interventional radiologists and one resident with only limited angiographic experience. RESULTS: Stable extracorporeal perfusion was successfully established on both thighs of all three body donors. Digital subtraction angiography could be performed reliably and resulted in realistic artery depiction. The model allowed for repeatable training of endovascular recanalization and arterial embolization procedures with typical tactile feedback in a controlled environment. Furthermore, the handling of more complex angiographic devices could be exercised. Whereas procedural success was be ascertained for most endovascular interventions, thrombectomies procedures were not feasible in some cases due to the lack of inherent coagulation. CONCLUSION: The presented perfusion model is suitable for practicing time-critical endovascular interventions in the lower extremity runoff under realistic but controlled conditions.


Assuntos
Procedimentos Endovasculares , Doenças Vasculares , Humanos , Procedimentos Endovasculares/métodos , Artérias , Angioplastia/métodos , Stents , Cadáver , Resultado do Tratamento , Estudos Retrospectivos
15.
Rofo ; 195(11): 1009-1017, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37224864

RESUMO

PURPOSE: To assess radiation exposure and diagnostic performance of bilateral inferior petrosal sinus sampling for the distinction of pituitary and ectopic adrenocorticotropin-dependent Cushing's syndrome. MATERIALS AND METHODS: Procedural data of bilateral inferior petrosal sinus procedures were retrospectively evaluated. The analysis included the patients' clinical and demographic data, procedural radiation exposure, and complication rates, sampling results, clinical course of the patients, and calculation of diagnostic performance data. RESULTS: The cases of 46 patients diagnosed with adrenocorticotropin-dependent Cushing's syndrome were evaluated. Bilateral inferior petrosal sinus sampling was successfully performed in 97.8 % of the cases. The overall median procedure-related fluoroscopy time was 7.8 min. (range 3.2-36.2 min.), and the median procedural dose area product was 11.9 Gy*cm2 (range 2.1-73.7 Gy*cm2). Radiation doses due to digital subtraction angiography series for visualization of the inferior petrosal sinus were 3.6 Gy*cm2 (range 1.0-18.1 Gy*cm2). Radiation doses due to fluoroscopy had a higher impact on the overall radiation exposure and were significantly influenced by the patients' habitus. The sensitivity, specificity, and positive and negative predictive values were 84 %, 100 %, 100 %, and 72 % before stimulation with corticotropin-releasing hormone, and 97 %, 100 %, 100 %, and 93 % after stimulation. Concordance between magnetic resonance imaging studies and bilateral inferior petrosal sinus sampling results was only found in 35.6 % of the cases. The periprocedural complication rate was 2.2 %, with one patient experiencing vasovagal syncope during catheterization. CONCLUSION: Bilateral inferior petrosal sinus sampling is a safe procedure with high technical success rates und excellent diagnostic performance. The procedure-related radiation exposure shows large variations and depends on the complexity of cannulation as well as the patients' habitus. Fluoroscopy accounted for the largest proportion of radiation exposure. Acquisition of digital subtraction angiography series for the verification of correct catheter placement appears justified. KEY POINTS: · Bilateral inferior petrosal sinus sampling with CRH stimulation provides high diagnostic performance in the distinction of pituitary and ectopic Cushing's syndrome.. · The associated radiation exposure is not negligible and is significantly influenced by the use of fluoroscopy and the patients' habitus.. · Digital subtraction angiography contributes less to the overall radiation dose and appears justified for the verification of correct catheter placement.. CITATION FORMAT: · Augustin A, Detomas M, Hartung V et al. Bilateral inferior petrosal sinus sampling: Procedural data from a German single-center study. Fortschr Röntgenstr 2023; 195: 1009 - 1017.


Assuntos
Síndrome de ACTH Ectópico , Síndrome de Cushing , Humanos , Síndrome de Cushing/diagnóstico , Estudos Retrospectivos , Diagnóstico Diferencial , Hormônio Adrenocorticotrópico , Hormônio Liberador da Corticotropina , Síndrome de ACTH Ectópico/diagnóstico
16.
PLoS One ; 18(5): e0285810, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37220113

RESUMO

OBJECTIVES: We developed a novel human cadaveric perfusion model with continuous extracorporeal femoral perfusion suitable for performing intra-individual comparison studies, training of interventional procedures and preclinical testing of endovascular devices. Objective of this study was to introduce the techniques and evaluate the feasibility for realistic computed tomography angiography (CTA), digital subtraction angiography (DSA) including vascular interventions, and intravascular ultrasound (IVUS). METHODS: The establishment of the extracorporeal perfusion was attempted using one formalin-fixed and five fresh-frozen human cadavers. In all specimens, the common femoral and popliteal arteries were prepared, introducer sheaths inserted, and perfusion established by a peristaltic pump. Subsequently, we performed CTA and bilateral DSA in five cadavers and IVUS on both legs of four donors. Examination time without unintentional interruption was measured both with and without non-contrast planning CT. Percutaneous transluminal angioplasty and stenting was performed by two interventional radiologists on nine extremities (five donors) using a broad spectrum of different intravascular devices. RESULTS: The perfusion of the upper leg arteries was successfully established in all fresh-frozen but not in the formalin-fixed cadaver. The experimental setup generated a stable circulation in each procedure (ten upper legs) for a period of more than six hours. Images acquired with CT, DSA and IVUS offered a realistic impression and enabled the sufficient visualization of all examined vessel segments. Arterial cannulating, percutaneous transluminal angioplasty as well as stent deployment were feasible in a way that is comparable to a vascular intervention in vivo. The perfusion model allowed for introduction and testing of previously not used devices. CONCLUSIONS: The continuous femoral perfusion model can be established with moderate effort, works stable, and is utilizable for medical imaging of the peripheral arterial system using CTA, DSA and IVUS. Therefore, it appears suitable for research studies, developing skills in interventional procedures and testing of new or unfamiliar vascular devices.


Assuntos
Perna (Membro) , Tomografia Computadorizada por Raios X , Humanos , Angiografia Digital , Perfusão , Cadáver , Formaldeído , Ultrassonografia de Intervenção
17.
Sci Rep ; 13(1): 12109, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37495759

RESUMO

This study evaluated the influence of different vascular reconstruction kernels on the image quality of CT angiographies of the lower extremity runoff using a 1st-generation photon-counting-detector CT (PCD-CT) compared with dose-matched examinations on a 3rd-generation energy-integrating-detector CT (EID-CT). Inducing continuous extracorporeal perfusion in a human cadaveric model, we performed CT angiographies of eight upper leg arterial runoffs with radiation dose-equivalent 120 kVp acquisition protocols (CTDIvol 5 mGy). Reconstructions were executed with different vascular kernels, matching the individual modulation transfer functions between scanners. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were computed to assess objective image quality. Six radiologists evaluated image quality subjectively using a forced-choice pairwise comparison tool. Interrater agreement was determined by calculating Kendall's concordance coefficient (W). The intraluminal attenuation of PCD-CT images was significantly higher than of EID-CT (414.7 ± 27.3 HU vs. 329.3 ± 24.5 HU; p < 0.001). Using comparable kernels, image noise with PCD-CT was significantly lower than with EID-CT (p ≤ 0.044). Correspondingly, SNR and CNR were approximately twofold higher for PCD-CT (p < 0.001). Increasing the spatial frequency for PCD-CT reconstructions by one level resulted in similar metrics compared to EID-CT (CNRfat; EID-CT Bv49: 21.7 ± 3.7 versus PCD-CT Bv60: 21.4 ± 3.5). Overall image quality of PCD-CTA achieved ratings superior to EID-CTA irrespective of the used reconstruction kernels (best: PCD-CT Bv60; worst: EID-CT Bv40; p < 0.001). Interrater agreement was good (W = 0.78). Concluding, PCD-CT offers superior intraluminal attenuation, SNR, and CNR compared to EID-CT in angiographies of the upper leg arterial runoff. Combined with improved subjective image quality, PCD-CT facilitates the use of sharper convolution kernels and ultimately bears the potential of improved vascular structure assessability.


Assuntos
Angiografia por Tomografia Computadorizada , Perna (Membro) , Humanos , Angiografia por Tomografia Computadorizada/métodos , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X/métodos , Angiografia
18.
Diagnostics (Basel) ; 13(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38132229

RESUMO

This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images. For image quality assessment, contrast-to-noise ratios (CNRs) were calculated, and subjective evaluation (overall quality, luminal contrast, vessel sharpness, blooming, and beam hardening) was performed independently by three radiologists. Fifty-seven patients (12 women, 45 men) were included with a median interval between examinations of 12.7 months (interquartile range 11.1 months). Using manufacturer-recommended scan protocols resulted in a substantially lower radiation dose in PCD-CT (size-specific dose estimate: 4.88 ± 0.48 versus 6.28 ± 0.50 mGy, p < 0.001), while CNR was approximately 50% higher (41.11 ± 8.68 versus 27.05 ± 6.73, p < 0.001). Overall image quality and luminal contrast were deemed superior in PCD-CT (p < 0.001). Notably, EID-CT allowed for comparable vessel sharpness (p = 0.439) and less pronounced blooming and beam hardening (p < 0.001). Inter-rater agreement was good to excellent (0.58-0.87). Concluding, aortic PCD-CTAs facilitate increased image quality with significantly lower radiation dose compared to EID-CTAs.

19.
Eur Radiol Exp ; 7(1): 83, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110729

RESUMO

BACKGROUND: With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies. METHODS: After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode. Images were reconstructed with dedicated convolution kernels (soft: Body-vascular (Bv)48; sharp: Bv60; ultrasharp: Bv76). Six radiologists evaluated the image quality by means of a pairwise forced-choice comparison tool. Kendall's concordance coefficient (W) was calculated to quantify interrater agreement. Image quality was further assessed by measuring intraluminal attenuation and image noise as well as by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR). RESULTS: UHR yielded lower noise than SR for identical reconstructions with kernels ≥ Bv60 (p < 0.001). UHR scans exhibited lower intraluminal attenuation compared to SR (Bv60: 406.4 ± 25.1 versus 418.1 ± 30.1 HU; p < 0.001). Irrespective of scan mode, SNR and CNR decreased while noise increased with sharper kernels but UHR scans were objectively superior to SR nonetheless (Bv60: SNR 25.9 ± 6.4 versus 20.9 ± 5.3; CNR 22.7 ± 5.8 versus 18.4 ± 4.8; p < 0.001). Notably, UHR scans were preferred in subjective assessment when images were reconstructed with the ultrasharp Bv76 kernel, whereas SR was rated superior for Bv60. Interrater agreement was high (W = 0.935). CONCLUSIONS: Combinations of UHR scan mode and ultrasharp convolution kernel are able to exploit the full image quality potential in photon-counting CT angiography of the femoral arteries. RELEVANCE STATEMENT: The UHR scan mode offers improved image quality and may increase diagnostic accuracy in CT angiography of the peripheral arterial runoff when optimized reconstruction parameters are chosen. KEY POINTS: • UHR photon-counting CT improves image quality in combination with ultrasharp convolution kernels. • UHR datasets display lower image noise compared with identically reconstructed standard resolution scans. • Scans in UHR mode show decreased intraluminal attenuation compared with standard resolution imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Artéria Femoral , Humanos , Angiografia por Tomografia Computadorizada/métodos , Artéria Femoral/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Angiografia
20.
Abdom Radiol (NY) ; 47(10): 3604-3614, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35790568

RESUMO

PURPOSE: To evaluate the technical and clinical outcome of Sinus-XL stent placement in patients with malignant obstruction syndrome of the inferior vena cava. METHODS: Between October 2010 and January 2021, 21 patients with different malignant primary disease causing inferior vena cava obstruction were treated with Sinus-XL stent implantation. Procedural data, technical and clinical outcome parameters were retrospectively analyzed. RESULTS: Technical success was 100%. Analysis of available manometry data revealed a significant reduction of the mean translesional pressure gradient following the procedure (p = 0.008). Reintervention rate was 4.8% (1/21). The available follow-up imaging studies showed primary and primary-assisted stent patency rates of 93% (13/14) and 100% (14/14), respectively. Major complications did not occur. The clinical success regarding lower extremity edema was 82.4% (14/17) for the first and 85.7% (18/21) for the last follow-up. Longer lengths of IVC obstruction were associated with reduced clinical improvement after the procedure (p = 0.025). Improvement of intraprocedural manometry results and lower extremity edema revealed only minor correlation. Ascites and anasarca were not significantly positively affected by the procedure. CONCLUSION: Sinus-XL stent placement in patients with malignant inferior vena cava obstruction showed high technical success and low complication rates. Regarding the clinical outcome, significant symptom improvement could be achieved in lower extremity edema, whereas ascites and anasarca lacked satisfying symptom relief. Based on our results, this procedure should be considered as a suitable therapy in a palliative care setting for patients with advanced malignant disease.


Assuntos
Procedimentos Endovasculares , Neoplasias , Doenças Vasculares , Ascite/complicações , Edema/complicações , Procedimentos Endovasculares/métodos , Humanos , Neoplasias/patologia , Estudos Retrospectivos , Stents/efeitos adversos , Síndrome , Resultado do Tratamento , Doenças Vasculares/complicações , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA