Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
JACC Cardiovasc Imaging ; 17(3): 314-329, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38448131

RESUMO

The advent of high-frame rate imaging in ultrasound allowed the development of shear wave elastography as a noninvasive alternative for myocardial stiffness assessment. It measures mechanical waves propagating along the cardiac wall with speeds that are related to stiffness. The use of cardiac shear wave elastography in clinical studies is increasing, but a proper understanding of the different factors that affect wave propagation is required to correctly interpret results because of the heart's thin-walled geometry and intricate material properties. The aims of this review are to give an overview of the general concepts in cardiac shear wave elastography and to discuss in depth the effects of age, hemodynamic loading, cardiac morphology, fiber architecture, contractility, viscoelasticity, and system-dependent factors on the measurements, with a focus on clinical application. It also describes how these factors should be considered during acquisition, analysis, and reporting to ensure an accurate, robust, and reproducible measurement of the shear wave.


Assuntos
Cardiologia , Técnicas de Imagem por Elasticidade , Humanos , Valor Preditivo dos Testes , Ultrassonografia , Miocárdio
3.
Artigo em Inglês | MEDLINE | ID: mdl-39002706

RESUMO

BACKGROUND: Myocardial diastolic function assessment in children by conventional echocardiography is challenging. Recent high frame rate (HFR) echocardiography facilitates the assessment of myocardial stiffness (MS) -a key factor of diastolic function- by measuring the propagation velocities of myocardial shear waves (SWs). However, normal values of natural SWs in children are currently lacking. OBJECTIVES: To explore the behavior of natural SW among children and adolescents, their reproducibility, and the factors affecting SW velocities from childhood into adulthood. METHODS: 106 healthy children (2-18 years) and 62 adults (19-80 years) were recruited. HFR images were acquired using a modified commercial scanner. An anatomical M-mode was drawn along the ventricular septum, and propagation velocities of natural SWs after mitral valve closure (MVC) were measured in the tissue acceleration coded M-mode display. RESULTS: Throughout life, SW velocities after MVC exhibited pronounced age dependency (r= 0.73; P<0.001). Among the pediatric population, SW velocities correlated significantly with measures of cardiac geometry (septal thickness and left ventricular end-diastolic dimension), local hemodynamics (systolic blood pressure), as well as with echocardiographic parameters of systolic and diastolic function (global longitudinal strain (GLS), mitral E/e', isovolumetric relaxation time and mitral deceleration time) (P <0.001). In a multivariate analysis including all these factors, the predictors of SW velocities were age, mitral E/e', and GLS (r= 0.81). CONCLUSIONS: Natural myocardial SW velocities in children can be detected and measured. SW velocities showed significant dependence on age and diastolic function. Natural SWs could be a promising additive tool for assessment of diastolic function among children.

4.
J Appl Physiol (1985) ; 136(3): 606-617, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38328825

RESUMO

We aimed to develop a large animal model of subcoronary aortic stenosis (AS) to study intracoronary and microcirculatory hemodynamics. A total of three surgical techniques inducing AS were evaluated in 12 sheep. Suturing the leaflets together around a dilator (n = 2) did not result in severe AS. Suturing of a pericardial patch with a variable opening just below the aortic valve (n = 5) created an AS which was poorly tolerated if the aortic valve area (AVA) was too small (0.38-1.02 cm2), but was feasible with an AVA of 1.2 cm2. However, standardization of aortic regurgitation (AR) with this technique is difficult. Therefore, we opted for implantation of an undersized AV-bioprosthesis with narrowing sutures on the leaflets (n = 5). Overall, five sheep survived the immediate postoperative period of which three had severe AS (one patch and two bioprostheses). The surviving sheep with severe AS developed left ventricular hypertrophy and signs of increased filling-pressures. Intracoronary assessment of physiological indices in these AS sheep pointed toward the development of functional microvascular dysfunction, with a significant increase in coronary resting flow and hyperemic coronary resistance, resulting in a significantly higher index of microvascular resistance (IMR) and lower myocardial resistance reserve (MRR). Microscopic analysis showed myocardial hypertrophy and signs of fibrosis without evidence of capillary rarefaction. In a large animal model of AS, microvascular changes are characterized by increased resting coronary flow and hyperemic coronary resistance resulting in increased IMR and decreased MRR. These physiological changes can influence the interpretation of regularly used coronary indices.NEW & NOTEWORTHY In an animal model of aortic valve stenosis (AS), coronary physiological changes are characterized by increased resting coronary flow and hyperemic coronary resistance. These changes can impact coronary indices frequently used to assess concomitant coronary artery disease (CAD). At this point, the best way to assess and treat CAD in AS remains unclear. Our data suggest that fractional flow reserve may underestimate CAD, and nonhyperemic pressure ratios may overestimate CAD severity before aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Animais , Ovinos , Microcirculação , Circulação Coronária , Hemodinâmica , Estenose da Valva Aórtica/cirurgia , Estenose Coronária/cirurgia , Estenose Coronária/diagnóstico
5.
Echo Res Pract ; 11(1): 14, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825684

RESUMO

BACKGROUND: Echocardiography is widely used to evaluate left ventricular (LV) diastolic function in patients suspected of heart failure. For patients in sinus rhythm, a combination of several echocardiographic parameters can differentiate between normal and elevated LV filling pressure with good accuracy. However, there is no established echocardiographic approach for the evaluation of LV filling pressure in patients with atrial fibrillation. The objective of the present study was to determine if a combination of several echocardiographic and clinical parameters may be used to evaluate LV filling pressure in patients with atrial fibrillation. RESULTS: In a multicentre study of 148 atrial fibrillation patients, several echocardiographic parameters were tested against invasively measured LV filling pressure as the reference method. No single parameter had sufficiently strong association with LV filling pressure to be recommended for clinical use. Based on univariate regression analysis in the present study, and evidence from existing literature, we developed a two-step algorithm for differentiation between normal and elevated LV filling pressure, defining values ≥ 15 mmHg as elevated. The parameters in the first step included the ratio between mitral early flow velocity and septal mitral annular velocity (septal E/e'), mitral E velocity, deceleration time of E, and peak tricuspid regurgitation velocity. Patients who could not be classified in the first step were tested in a second step by applying supplementary parameters, which included left atrial reservoir strain, pulmonary venous systolic/diastolic velocity ratio, and body mass index. This two-step algorithm classified patients as having either normal or elevated LV filling pressure with 75% accuracy and with 85% feasibility. Accuracy in EF ≥ 50% and EF < 50% was similar (75% and 76%). CONCLUSIONS: In patients with atrial fibrillation, no single echocardiographic parameter was sufficiently reliable to be used clinically to identify elevated LV filling pressure. An algorithm that combined several echocardiographic parameters and body mass index, however, was able to classify patients as having normal or elevated LV filling pressure with moderate accuracy and high feasibility.

6.
IEEE Trans Biomed Eng ; 70(1): 259-270, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35788461

RESUMO

BACKGROUND: Shear wave elastography (SWE) is a promising technique to non-invasively assess myocardial stiffness based on the propagation speed of mechanical waves. However, a high wave propagation speed can either be attributed to an elevated intrinsic myocardial stiffness or to a preload-induced increase in operational stiffness. OBJECTIVE: Our objective was to find a way to discriminate intrinsic myocardial stiffening from stiffening caused by an increased pressure in SWE. METHODS: We used the finite element method to study the shear wave propagation patterns when stiffness and/or pressure is elevated, compared to normal stiffness and pressure. Numerical findings were verified in a few human subjects. RESULTS: The transmural wave speed gradient was able to distinguish changes in intrinsic stiffness from those induced by differing hemodynamic load (a speed of ±3.2 m/s in parasternal short-axis (PSAX) view was associated with a wave speed gradient of -0.17 ± 0.15 m/s/mm when pressure was elevated compared to 0.04 ± 0.05 m/s/mm when stiffness was elevated). The gradient however decreased when stiffness increased (decrease with a factor 3 in PSAX when stiffness doubled at 20 mmHg). The human data analysis confirmed the presence of a wave speed gradient in a patient with elevated ventricular pressure. CONCLUSION: Cardiac SWE modeling is a useful tool to gain additional insights into the complex wave physics and to guide post-processing. The transmural differences in wave speed may help to distinguish loading-induced stiffening from intrinsic stiffness changes. SIGNIFICANCE: The transmural wave speed gradient has potential as a new diagnostic parameter for future clinical studies.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Coração/diagnóstico por imagem , Miocárdio , Microcirurgia
7.
Eur Heart J Cardiovasc Imaging ; 24(5): 635-642, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-35852912

RESUMO

AIMS: In pulmonary arterial hypertension (PAH), the right ventricle (RV) is exposed to an increased afterload. In response, RV mechanics are altered. Markers which would relate RV function and afterload could therefore aid to understand this complex response system and could be of prognostic value. The aim of our study was to (i) assess the RV-arterial coupling using ratio between RV strain and systolic pulmonary artery pressure (sPAP), in patients with PAH, and (ii) investigate the prognostic value of this new parameter over other echocardiographic parameters. METHODS AND RESULTS: Echocardiograms of 65 pre-capillary PAH patients (45 females, age 61 ± 15 years) were retrospectively analysed. Fractional area change (FAC), sPAP, tricuspid annular plane systolic excursion, and RV free-wall (FW) longitudinal strain (LS) were measured. A primary endpoint of death or heart/lung transplantation described clinical endpoint. Patients who reached a clinical endpoint had worse functional capacity (New York Heart Association), reduced RV function, and higher sPAP. Left ventricle function was similar in both groups. Only RVFW LS/sPAP ratio was found as an independent predictor of clinical endpoint in multivariable analysis (hazard ratio 8.3, 95% confidence interval 3.2-21.6, P < 0.001). The RWFW LS/sPAP (cut-off 0.19) demonstrated a good accuracy for the prediction of reaching the clinical endpoint, with a sensitivity of 92% and specificity of 82.5%. CONCLUSION: RVFW LS/sPAP ratio significantly predicts all-cause mortality and heart-lung transplantation, and was superior to other well-established parameters, in patients with pre-capillary PAH. We therefore propose RVFW LS/sPAP as a new prognostic echocardiographic marker.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Disfunção Ventricular Direita , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Ventrículos do Coração/diagnóstico por imagem , Hipertensão Arterial Pulmonar/complicações , Artéria Pulmonar , Estudos Retrospectivos , Ecocardiografia/métodos , Função Ventricular Direita
8.
Sci Rep ; 13(1): 17660, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37848474

RESUMO

Ultrasound-based shear wave elastography is a promising technique to non-invasively assess the dynamic stiffness variations of the heart. The technique is based on tracking the propagation of acoustically induced shear waves in the myocardium of which the propagation speed is linked to tissue stiffness. This measurement is repeated multiple times across the cardiac cycle to assess the natural variations in wave propagation speed. The interpretation of these measurements remains however complex, as factors such as loading and contractility affect wave propagation. We therefore applied transthoracic shear wave elastography in 13 pigs to investigate the dependencies of wave speed on pressure-volume derived indices of loading, myocardial stiffness, and contractility, while altering loading and inducing myocardial ischemia/reperfusion injury. Our results show that diastolic wave speed correlates to a pressure-volume derived index of operational myocardial stiffness (R = 0.75, p < 0.001), suggesting that both loading and intrinsic properties can affect diastolic wave speed. Additionally, the wave speed ratio, i.e. the ratio of systolic and diastolic speed, correlates to a pressure-volume derived index of contractility, i.e. preload-recruitable stroke work (R = 0.67, p < 0.001). Measuring wave speed ratio might thus provide a non-invasive index of contractility during ischemia/reperfusion injury.


Assuntos
Técnicas de Imagem por Elasticidade , Coração , Animais , Suínos , Coração/diagnóstico por imagem , Miocárdio , Diástole , Técnicas de Imagem por Elasticidade/métodos , Tórax
9.
J Clin Med ; 12(18)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37763048

RESUMO

Background and aim: The presence of mechanical dyssynchrony on echocardiography is associated with reverse remodelling and decreased mortality after cardiac resynchronization therapy (CRT). Contrarily, myocardial scar reduces the effect of CRT. This study investigated how well a combined assessment of different markers of mechanical dyssynchrony and scarring identifies CRT responders. Methods: In a prospective multicentre study of 170 CRT recipients, septal flash (SF), apical rocking (ApRock), systolic stretch index (SSI), and lateral-to-septal (LW-S) work differences were assessed using echocardiography. Myocardial scarring was quantified using cardiac magnetic resonance imaging (CMR) or excluded based on a coronary angiogram and clinical history. The primary endpoint was a CRT response, defined as a ≥15% reduction in LV end-systolic volume 12 months after implantation. The secondary endpoint was time-to-death. Results: The combined assessment of mechanical dyssynchrony and septal scarring showed AUCs ranging between 0.81 (95%CI: 0.74-0.88) and 0.86 (95%CI: 0.79-0.91) for predicting a CRT response, without significant differences between the markers, but significantly higher than mechanical dyssynchrony alone. QRS morphology, QRS duration, and LV ejection fraction were not superior in their prediction. Predictive power was similar in the subgroups of patients with ischemic cardiomyopathy. The combined assessments significantly predicted all-cause mortality at 44 ± 13 months after CRT with a hazard ratio ranging from 0.28 (95%CI: 0.12-0.67) to 0.20 (95%CI: 0.08-0.49). Conclusions: The combined assessment of mechanical dyssynchrony and septal scarring identified CRT responders with high predictive power. Both visual and quantitative markers were highly feasible and demonstrated similar results. This work demonstrates the value of imaging LV mechanics and scarring in CRT candidates, which can already be achieved in a clinical routine.

10.
Ultrasound Med Biol ; 48(8): 1644-1651, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35637027

RESUMO

Stress echocardiography helps to diagnose cardiac diseases that cannot easily be detected or do not even manifest at rest. In clinical practice, assessment of the stress test is usually performed visually and, therefore, in a qualitative and subjective way. Although speckle tracking echocardiography (STE) has been proposed for the quantification of function during stress, its time resolution is inadequate at high heart rates. Recently, high-frame-rate (HFR) imaging approaches have been proposed together with dedicated STE algorithms capable of handling small interframe displacements. The aim of this study was to determine if HFR STE is effective in assessing strain and strain rate parameters during echocardiographic stress testing. Specifically, stress echocardiography, at four different workload intensities, was performed in 25 healthy volunteers. At each stress level, HFR images from the apical four-chamber view were recorded using the ULA-OP 256 experimental scanner. Then, the myocardium was tracked with HFR STE, and strain and strain rate biomarkers were extracted to further analyze systolic and diastolic (early and late) peaks, as well as a short-lived isovolumic relaxation peak during stress testing. The global systolic strain response was monophasic, revealing a significant (p < 0.001) increase at low stress but then reaching a plateau. In contrast, all strain rate indices linearly increased (p < 0.001) with increasing stress level. These findings are in line with those reported using tissue Doppler imaging and, thus, indicate that HFR STE can be a useful tool in assessing cardiac function during stress echocardiography.


Assuntos
Ecocardiografia , Teste de Esforço , Diástole , Ecocardiografia/métodos , Frequência Cardíaca/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Sístole/fisiologia
11.
Ultrasound Med Biol ; 48(11): 2207-2216, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35963827

RESUMO

Shear wave elastography (SWE) is a promising technique used to assess cardiac function through the evaluation of cardiac stiffness non-invasively. However, in the literature, SWE varies in terms of tissue motion data (displacement, velocity or acceleration); method used to characterize mechanical wave propagation (time domain [TD] vs. frequency domain [FD]); and the metric reported (wave speed [WS], shear or Young's modulus). This variety of reported methodologies complicates comparison of reported findings and sheds doubt on which methodology better approximates the true myocardial properties. We therefore conducted a simulation study to investigate the accuracy of various SWE data analysis approaches while varying cardiac geometry and stiffness. Lower WS values were obtained by the TD method compared with the FD method. Acceleration-based WS estimates in the TD were systematically larger than those based on velocity (∼10% difference). These observations were confirmed by TD analysis of 32 in vivo SWE mechanical wave measurements. In vivo data quality is typically too low for accurate FD analysis. Therefore, our study suggests using acceleration-based TD analysis for in vivo SWE to minimize underestimation of the true WS and, thus, to maximize the sensitivity of SWE to detect stiffness changes resulting from pathology.


Assuntos
Técnicas de Imagem por Elasticidade , Aceleração , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Coração/diagnóstico por imagem , Movimento (Física)
12.
JACC Cardiovasc Imaging ; 15(12): 2023-2034, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36163339

RESUMO

BACKGROUND: Shear wave elastography (SWE) has been proposed as a novel noninvasive method for the assessment of myocardial stiffness, a relevant determinant of diastolic function. It is based on tracking the propagation of shear waves, induced, for instance, by mitral valve closure (MVC), in the myocardium. The speed of propagation is directly related to myocardial stiffness, which is defined by the local slope of the nonlinear stress-strain relation. Therefore, the operating myocardial stiffness can be altered by both changes in loading and myocardial mechanical properties. OBJECTIVES: This study sought to evaluate the capability of SWE to quantify myocardial stiffness changes in vivo by varying loading and myocardial tissue properties and to compare SWE against pressure-volume loop analysis, a gold standard reference method. METHODS: In 15 pigs, conventional and high-frame rate echocardiographic data sets were acquired simultaneously with pressure-volume loop data after acutely changing preload and afterload and after inducting an ischemia/reperfusion (I/R) injury. RESULTS: Shear wave speed after MVC significantly increased by augmenting preload and afterload (3.2 ± 0.8 m/s vs 4.6 ± 1.2 m/s and 4.6 ± 1.0 m/s, respectively; P = 0.001). Preload reduction had no significant effect on shear wave speed compared to baseline (P = 0.118). I/R injury resulted in significantly higher shear wave speed after MVC (6.1 ± 1.2 m/s; P < 0.001). Shear wave speed after MVC had a strong correlation with the chamber stiffness constant ß (r = 0.63; P < 0.001) and operating chamber stiffness dP/dV before induction of an I/R injury (r = 0.78; P < 0.001) and after (r = 0.83; P < 0.001). CONCLUSIONS: Shear wave speed after MVC was influenced by both acute changes in loading and myocardial mechanical properties, reflecting changes in operating myocardial stiffness, and was strongly related to chamber stiffness, invasively derived by pressure-volume loop analysis. SWE provides a novel noninvasive method for the assessment of left ventricular myocardial properties.


Assuntos
Técnicas de Imagem por Elasticidade , Valva Mitral , Animais , Valor Preditivo dos Testes , Suínos
13.
Artigo em Inglês | MEDLINE | ID: mdl-33170777

RESUMO

High-frame-rate (HFR) speckle-tracking echocardiography (STE) assesses myocardial function by quantifying motion and deformation at high temporal resolution. Among the proposed HFR techniques, multiline transmission (MLT) and diverging wave (DW) imaging have been used in this context both being characterized by specific advantages and disadvantages. Therefore, in this article, we directly contrast both approaches in an in vivo setting while operating at the same frame rate (FR). First, images were recorded at baseline (resting condition) from healthy volunteers and patients. Next, additional acquisitions during stress echocardiography were performed on volunteers. Each scan was contoured and processed by a previously proposed 2-D HFR STE algorithm based on cross correlation. Then, strain curves and their end-systolic (ES) values were extracted for all myocardial segments for further statistical analysis. The baseline acquisitions did not reveal differences in estimated strain between the acquisition modes ( ); myocardial segments ( ); or an interaction between imaging mode and depth ( ). Similarly, during stress testing, no difference ( p = 0.7 ) was observed for the two scan sequences, stress levels or an interaction sequence-stress level ( p = 0.94 ). Overall, our findings show that MLT and DW compoundings give comparable HFR STE strain values and that the choice for using one method or the other may thus rather be based on other factors, for example, system requirements or computational cost.


Assuntos
Ecocardiografia sob Estresse , Ecocardiografia , Algoritmos , Humanos , Reprodutibilidade dos Testes
14.
Int J Cardiovasc Imaging ; 37(5): 1689-1697, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33454899

RESUMO

Despite standardization efforts, vendors still use specific proprietary software algorithms for echocardiographic strain measurements, which result in high inter-vendor variability. Using vendor-independent software could be one solution. Little is known, however, how vendor specific image characteristics can influence tracking results of such software. We therefore investigated the reproducibility, accuracy, and scar detection ability of strain measurements on images from different vendors by using a vendor-independent software. A vendor-independent software (TomTec Image Arena) was used to analyse datasets of 63 patients which were obtained on machines from four different ultrasound machine vendors (GE, Philips, Siemens, Toshiba). We measured the tracking feasibility, inter-vendor bias, the relative test-re-test variability and scar discrimination ability of strain measurements. Cardiac magnetic resonance delayed enhancement images were used as the reference standard of scar definition. Tracking feasibility on vendor datasets were significantly different (p < 0.001). Variability of global longitudinal strain (GLS) measurements was similar among the vendors whereas variability of segmental longitudinal strain (SLS) showed modest difference. Relative test-re-test variability of GLS and SLS showed no relevant differences. No significant difference in scar detection capability was observed. Average GLS and SLS values were similar among vendors. Reproducibility of GLS measurements showed no difference among vendors and was in acceptable range. SLS reproducibility was high but similar for all vendors. No relevant difference was found for identifying regional dysfunction. Tracking feasibility showed a substantial difference among images from different vendors. Our findings demonstrate that tracking results depend mainly on the software used and show little influence from vendor specific image characteristics.


Assuntos
Ecocardiografia , Software , Algoritmos , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
15.
Artigo em Inglês | MEDLINE | ID: mdl-32286969

RESUMO

Speckle tracking echocardiography (STE) is a clinical tool to noninvasively assess regional myocardial function through the quantification of regional motion and deformation. Even if the time resolution of STE can be improved by high-frame-rate (HFR) imaging, dedicated HFR STE algorithms have to be developed to detect very small interframe motions. Therefore, in this article, we propose a novel 2-D STE method, purposely developed for HFR echocardiography. The 2-D motion estimator consists of a two-step algorithm based on the 1-D cross correlations to separately estimate the axial and lateral displacements. The method was first optimized and validated on simulated data giving an accuracy of ~3.3% and ~10.5% for the axial and lateral estimates, respectively. Then, it was preliminarily tested in vivo on ten healthy volunteers showing its clinical applicability and feasibility. Moreover, the extracted clinical markers were in the same range as those reported in the literature. Also, the estimated peak global longitudinal strain was compared with that measured with a clinical scanner showing good correlation and negligible differences (-20.94% versus -20.31%, p -value = 0.44). In conclusion, a novel algorithm for STE was developed: the radio frequency (RF) signals were preferred for the axial motion estimation, while envelope data were preferred for the lateral motion. Furthermore, using 2-D kernels, even for 1-D cross correlation, makes the method less sensitive to noise.


Assuntos
Ecocardiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Adulto , Algoritmos , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino
16.
Artigo em Inglês | MEDLINE | ID: mdl-31514130

RESUMO

Major cardiovascular diseases (CVDs) are associated with (regional) dysfunction of the left ventricle. Despite the 3-D nature of the heart and its dynamics, the assessment of myocardial function is still largely based on 2-D ultrasound imaging, thereby making diagnosis heavily susceptible to the operator's expertise. Unfortunately, to date, 3-D echocardiography cannot provide adequate spatiotemporal resolution in real-time. Hence, tri-plane imaging has been introduced as a compromise between 2-D and true volumetric ultrasound imaging. However, tri-plane imaging typically requires high-end ultrasound systems equipped with fully populated matrix array probes embedded with expensive and little flexible electronics for two-stage beamforming. This article presents an advanced ultrasound system for real-time, high frame rate (HFR), and tri-plane echocardiography based on low element count sparse arrays, i.e., the so-called spiral arrays. The system was simulated, experimentally validated, and implemented for real-time operation on the ULA-OP 256 system. Five different array configurations were tested together with four different scan sequences, including multi-line and planar diverging wave transmission. In particular, the former can be exploited to achieve, in tri-plane imaging, the same temporal resolution currently used in clinical 2-D echocardiography, at the expenses of contrast (-3.5 dB) and signal-to-noise ratio (SNR) (-8.7 dB). On the other hand, the transmission of planar diverging waves boosts the frame rate up to 250 Hz, but further compromises contrast (-10.5 dB), SNR (-9.7 dB), and lateral resolution (+46%). In conclusion, despite an unavoidable loss in image quality and sensitivity due to the limited number of elements, HFR tri-plane imaging with spiral arrays is shown to be feasible in real-time and may enable real-time functional analysis of all left ventricular segments of the heart.


Assuntos
Ecocardiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Simulação por Computador , Coração/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
17.
Eur Heart J Cardiovasc Imaging ; 21(3): 337-343, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31361311

RESUMO

AIMS: Foreshortening of apical views is a common problem in echocardiography. It results in an abnormally thick false apex and a shortened left ventricular (LV) long axis. We sought to evaluate the impact of foreshortened (FS) on LV ejection fraction (LVEF) and layer-specific 2D speckle tracking based segmental (S) and global (G) longitudinal strain (LS) measurements. METHODS AND RESULTS: We examined 72 participants using a GE Vivid E9 system. FS apical views were collected from an imaging window one rib-space higher than the optimal images. Ejection fraction as well as layer-specific GLS and SLS measurements were analysed by GE EchoPAC v201 and TomTec Image Arena 4.6 and compared between optimal and FS images. On average, LV long axis was 10% shorter in FS images than in optimal images. FS induced a relative change in LVEF of 3.3% and 6.9% for GE and TomTec, respectively (both, P < 0.001). Endocardial GLS was 9.0% higher with GE and 23.2% with TomTec (P < 0.001). Midwall GLS measurements were less affected (7.8% for GE and 14.1% for TomTec, respectively, both P < 0.001). Segmental strain analysis revealed that the mid-ventricular and apical segments were more affected by foreshortening, and endocardial measurements were more affected than midwall. CONCLUSION: Optimal image geometry is crucial for accurate LV function assessment. Foreshorhening of apical views has a substantial impact on longitudinal strain measurements, predominantly in the apex and in the endocardial layer. Our data suggest that measuring midwall strain might therefore be the more robust approach for clinical routine use.


Assuntos
Ecocardiografia , Disfunção Ventricular Esquerda , Ventrículos do Coração/diagnóstico por imagem , Humanos , Padrões de Referência , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
18.
Eur Heart J Cardiovasc Imaging ; 21(6): 664-672, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31377789

RESUMO

AIMS: To determine myocardial stiffness by means of measuring the velocity of naturally occurring myocardial shear waves (SWs) at mitral valve closure (MVC) and investigate their changes with myocardial remodelling in patients with hypertensive heart disease. METHODS AND RESULTS: Thirty-three treated arterial hypertension (HT) patients with hypertrophic left ventricular (LV) remodelling (59 ± 14 years, 55% male) and 26 aged matched healthy controls (55±15 years, 77% male) were included. HT patients were further divided into a concentric remodelling (HT1) group (13 patients) and a concentric hypertrophy (HT2) group (20 patients). LV parasternal long-axis views were acquired with an experimental ultrasound scanner at 1266 ± 317 frames per seconds. The SW velocity induced by MVC was measured from myocardial acceleration maps. SW velocities differed significantly between HT patients and controls (5.83 ± 1.20 m/s vs. 4.04 ± 0.96 m/s; P < 0.001). In addition, the HT2 group had the highest SW velocities (P < 0.001), whereas values between controls and the HT1 group were comparable (P = 0.075). Significant positive correlations were found between SW velocity and LV remodelling (interventricular septum thickness: r = 0.786, P < 0.001; LV mass index: r = 0.761, P < 0.001). SW velocity normalized for wall stress indicated that myocardial stiffness in the HT2 group was twice as high as in controls (P < 0.001), whereas values of the HT1 group overlapped with the controls (P = 1.00). CONCLUSIONS: SW velocity as measure of myocardial stiffness is higher in HT patients compared with healthy controls, particularly in advanced hypertensive heart disease. Patients with concentric remodelling have still normal myocardial properties whereas patients with concentric hypertrophy show significant stiffening.


Assuntos
Cardiopatias , Hipertensão , Disfunção Ventricular Esquerda , Idoso , Ecocardiografia , Feminino , Humanos , Hipertensão/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Remodelação Ventricular
19.
JACC Cardiovasc Imaging ; 13(11): 2304-2313, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33004291

RESUMO

OBJECTIVES: The purpose of this study was to investigate whether propagation velocities of naturally occurring shear waves (SWs) at mitral valve closure (MVC) increase with the degree of diffuse myocardial injury (DMI) and with invasively determined LV filling pressures as a reflection of an increase in myocardial stiffness in heart transplantation (HTx) recipients. BACKGROUND: After orthotopic HTx, allografts undergo DMI that contributes to functional impairment, especially to increased passive myocardial stiffness, which is an important pathophysiological determinant of left ventricular (LV) diastolic dysfunction. Echocardiographic SW elastography is an emerging approach for measuring myocardial stiffness in vivo. Natural SWs occur after mechanical excitation of the myocardium, for example, after MVC, and their propagation velocity is directly related to myocardial stiffness, thus providing an opportunity to assess myocardial stiffness at end-diastole. METHODS: A total of 52 HTx recipients who underwent right heart catheterization (all) and cardiac magnetic resonance (CMR) (n = 23) during their annual check-up were prospectively enrolled. Echocardiographic SW elastography was performed in parasternal long axis views of the LV using an experimental scanner at 1,135 ± 270 frames per second. The degree of DMI was quantified with T1 mapping. RESULTS: SW velocity at MVC correlated best with native myocardial T1 values (r = 0.75; p < 0.0001) and was the best noninvasive parameter that correlated with pulmonary capillary wedge pressures (PCWP) (r = 0.54; p < 0.001). Standard echocardiographic parameters of LV diastolic function correlated poorly with both native T1 and PCWP values. CONCLUSIONS: End-diastolic SW propagation velocities, as measure of myocardial stiffness, showed a good correlation with CMR-defined diffuse myocardial injury and with invasively determined LV filling pressures in patients with HTx. Thus, these findings suggest that SW elastography has the potential to become a valuable noninvasive method for the assessment of diastolic myocardial properties in HTx recipients.


Assuntos
Técnicas de Imagem por Elasticidade , Transplante de Coração , Disfunção Ventricular Esquerda , Diástole , Seguimentos , Humanos , Valor Preditivo dos Testes , Função Ventricular Esquerda
20.
Eur Heart J Cardiovasc Imaging ; 21(6): 619-628, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32031587

RESUMO

AIMS: Investigating the acute impact of cardiac resynchronization therapy (CRT) on regional myocardial work distribution in the left ventricle (LV) and to which extent it is related to long-term reverse remodelling. METHODS AND RESULTS: One hundred and thirty heart failure patients, referred for CRT implantation, were recruited in our prospective multicentre study. Regional myocardial work was calculated from non-invasive segmental stress-strain loop area before and immediately after CRT. The magnitude of volumetric reverse remodelling was determined from the change in LV end-systolic volume, 11 ± 2 months after implantation. CRT caused acute redistribution of myocardial work across the LV, with an increase in septal work, and decrease in LV lateral wall work (all P < 0.05). Amongst all LV walls, the acute change in work in the septum and lateral wall of the four-chamber view correlated best and significantly with volumetric reverse remodelling (r = 0.62, P < 0.0001), with largest change seen in patients with most volumetric reverse remodelling. In multivariate linear regression analysis, including conventional parameters, such as pre-implant QRS morphology and duration, LV ejection fraction, ischaemic origin of cardiomyopathy, and the redistribution of work across the septal and lateral walls, the latter appeared as the strongest determinant of volumetric reverse remodelling after CRT (model R2 = 0.414, P < 0.0001). CONCLUSION: The acute redistribution of regional myocardial work between the septal and lateral wall of the LV is an important determinant of reverse remodelling after CRT implantation. Our data suggest that the treatment of the loading imbalance should, therefore, be the main aim of CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA