Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Phys Rev Lett ; 132(15): 151001, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38682982

RESUMO

We report on a measurement of astrophysical tau neutrinos with 9.7 yr of IceCube data. Using convolutional neural networks trained on images derived from simulated events, seven candidate ν_{τ} events were found with visible energies ranging from roughly 20 TeV to 1 PeV and a median expected parent ν_{τ} energy of about 200 TeV. Considering backgrounds from astrophysical and atmospheric neutrinos, and muons from π^{±}/K^{±} decays in atmospheric air showers, we obtain a total estimated background of about 0.5 events, dominated by non-ν_{τ} astrophysical neutrinos. Thus, we rule out the absence of astrophysical ν_{τ} at the 5σ level. The measured astrophysical ν_{τ} flux is consistent with expectations based on previously published IceCube astrophysical neutrino flux measurements and neutrino oscillations.

2.
Eur Radiol ; 33(5): 3775-3784, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36472701

RESUMO

OBJECTIVE: To compare unenhanced versus enhanced knee joint magnetic resonance imaging (MRI) to assess disease activity of juvenile idiopathic arthritis (JIA). METHODS: Fifty-three knee joint MRI examinations were performed on a 3-Tesla system in 27 patients (age: 11.40 ± 3.61 years; 21 females, 6 males). MRI protocols comprised PD-weighted sequences in addition to the widely used standard protocol. JIA subgroups comprised oligoarticular arthritis (n = 16), extended oligoarthritis (n = 6), rheumatoid factor-negative polyarticular arthritis (n = 3), enthesitis-related arthritis (n = 1), and psoriatic arthritis (n = 1). MR images were retrospectively analyzed by 3 experienced radiologists in two readings, using JAMRIS (juvenile arthritis MRI scoring) system and a modified IPSG (international prophylaxis study group) classification. In the first reading session, only unenhanced MR images were evaluated. In a second reading session, all images before and after contrast medium application were included. In order to avoid bias, an interval of at least 2 weeks was set between the two readings. The clinical JADAS10 (juvenile arthritis disease activity score) was calculated including clinical assessment and laboratory workup and correlated with MRI scores. Statistical analysis comprised Pearson's correlation for correlating two scoring results of unenhanced and the enhanced MRI, intra-class correlation coefficient (ICC) for inter- and intra-reader agreement. Diagnostic accuracy was calculated using ROC (receiver operating characteristics) curve analysis. RESULTS: Inter-reader agreement determined by ICC for unenhanced and enhanced MRI scores for IPSG was moderate (0.65, 95% CI 0.51-0.76, and 0.62, 95% CI 0.48-0.75) and high for JAMRIS (0.83, 95% CI 0.75-0.89, and 0.82, 95% CI 0.74-0.89). Intra-reader agreement was good to very good for JAMRIS (0.85 95% CI 0.81-0.88, 0.87 95% CI 0.83-0.89 and 0.96 95% CI 0.92-0.98) and IPSG (0.76 95% CI 0.62-0.86, 0.86 95% CI 0.77-0.92 and 0.92 95% CI 0.86-0.96). Scores of unenhanced MRI correlated with contrast-enhanced MRI: JAMRIS (r = 0.97, R2 = 0.93, p < 0.01), modified IPSG (r = 0.95, R2 = 0.91, p < 0.01). When using JADAS10 as a reference standard, moderate accuracy for both unenhanced and enhanced MRI scores was noted: JAMRIS (AUC = 0.68, 95% CI 0.51-0.85, and AUC = 0.66, 95% 0.49-0.82), IPSG score (AUC = 0.68, 95% 0.50-0.86, and AUC = 0.61, 95% 0.41-0.81). CONCLUSIONS: Our results suggest that contrast agent application could be omitted in JIA patients with an augmented knee MRI protocol comprising PD-weighted sequence. KEY POINTS: • Unenhanced MRI can detect disease activity of the knee joint in patients with JIA with equally high accuracy compared to contrast-enhanced MRI. • The intra- and inter-reader agreement was high for unenhanced and enhanced MRI JAMRIS scores, which indicate relatively good applicability of the scoring system, even for less experienced readers. • When using the clinical JADAS10 as a reference standard for the detection of disease activity, moderate accuracy for both unenhanced and enhanced MRI scores, both JAMRIS and IPSG, was noted, which might be caused by the fact that the majority of patients had either no or minimal clinical disease activity.


Assuntos
Artrite Juvenil , Masculino , Feminino , Humanos , Criança , Adolescente , Artrite Juvenil/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Articulação do Joelho/diagnóstico por imagem , Curva ROC , Meios de Contraste/farmacologia
3.
Phys Rev Lett ; 128(5): 051101, 2022 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35179913

RESUMO

We present an all-sky 90% confidence level upper limit on the cosmic flux of relativistic magnetic monopoles using 2886 days of IceCube data. The analysis was optimized for monopole speeds between 0.750c and 0.995c, without any explicit restriction on the monopole mass. We constrain the flux of relativistic cosmic magnetic monopoles to a level below 2.0×10^{-19} cm^{-2} s^{-1} sr^{-1} over the majority of the targeted speed range. This result constitutes the most strict upper limit to date for magnetic monopoles with ß≳0.8 and up to ß∼0.995 and fills the gap between existing limits on the cosmic flux of nonrelativistic and ultrarelativistic magnetic monopoles.

4.
Phys Rev Lett ; 129(15): 151801, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36269964

RESUMO

We present a search for an unstable sterile neutrino by looking for a resonant signal in eight years of atmospheric ν_{µ} data collected from 2011 to 2019 at the IceCube Neutrino Observatory. Both the (stable) three-neutrino and the 3+1 sterile neutrino models are disfavored relative to the unstable sterile neutrino model, though with p values of 2.8% and 0.81%, respectively, we do not observe evidence for 3+1 neutrinos with neutrino decay. The best-fit parameters for the sterile neutrino with decay model from this study are Δm_{41}^{2}=6.7_{-2.5}^{+3.9} eV^{2}, sin^{2}2θ_{24}=0.33_{-0.17}^{+0.20}, and g^{2}=2.5π±1.5π, where g is the decay-mediating coupling. The preferred regions of the 3+1+decay model from short-baseline oscillation searches are excluded at 90% C.L.

5.
Phys Rev Lett ; 129(1): 011804, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35841552

RESUMO

We report a search for nonstandard neutrino interactions (NSI) using eight years of TeV-scale atmospheric muon neutrino data from the IceCube Neutrino Observatory. By reconstructing incident energies and zenith angles for atmospheric neutrino events, this analysis presents unified confidence intervals for the NSI parameter ε_{µτ}. The best-fit value is consistent with no NSI at a p value of 25.2%. With a 90% confidence interval of -0.0041≤ε_{µτ}≤0.0031 along the real axis and similar strength in the complex plane, this result is the strongest constraint on any NSI parameter from any oscillation channel to date.

6.
Phys Rev Lett ; 125(12): 121104, 2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-33016752

RESUMO

We report on the first measurement of the astrophysical neutrino flux using particle showers (cascades) in IceCube data from 2010-2015. Assuming standard oscillations, the astrophysical neutrinos in this dedicated cascade sample are dominated (∼90%) by electron and tau flavors. The flux, observed in the sensitive energy range from 16 TeV to 2.6 PeV, is consistent with a single power-law model as expected from Fermi-type acceleration of high energy particles at astrophysical sources. We find the flux spectral index to be γ=2.53±0.07 and a flux normalization for each neutrino flavor of ϕ_{astro}=1.66_{-0.27}^{+0.25} at E_{0}=100 TeV, in agreement with IceCube's complementary muon neutrino results and with all-neutrino flavor fit results. In the measured energy range we reject spectral indices γ≤2.28 at ≥3σ significance level. Because of high neutrino energy resolution and low atmospheric neutrino backgrounds, this analysis provides the most detailed characterization of the neutrino flux at energies below ∼100 TeV compared to previous IceCube results. Results from fits assuming more complex neutrino flux models suggest a flux softening at high energies and a flux hardening at low energies (p value ≥0.06). The sizable and smooth flux measured below ∼100 TeV remains a puzzle. In order to not violate the isotropic diffuse gamma-ray background as measured by the Fermi Large Area Telescope, it suggests the existence of astrophysical neutrino sources characterized by dense environments which are opaque to gamma rays.

7.
Phys Rev Lett ; 125(14): 141801, 2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33064514

RESUMO

The results of a 3+1 sterile neutrino search using eight years of data from the IceCube Neutrino Observatory are presented. A total of 305 735 muon neutrino events are analyzed in reconstructed energy-zenith space to test for signatures of a matter-enhanced oscillation that would occur given a sterile neutrino state with a mass-squared differences between 0.01 and 100 eV^{2}. The best-fit point is found to be at sin^{2}(2θ_{24})=0.10 and Δm_{41}^{2}=4.5 eV^{2}, which is consistent with the no sterile neutrino hypothesis with a p value of 8.0%.

8.
Phys Rev Lett ; 124(5): 051103, 2020 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-32083934

RESUMO

This Letter presents the results from pointlike neutrino source searches using ten years of IceCube data collected between April 6, 2008 and July 10, 2018. We evaluate the significance of an astrophysical signal from a pointlike source looking for an excess of clustered neutrino events with energies typically above ∼1 TeV among the background of atmospheric muons and neutrinos. We perform a full-sky scan, a search within a selected source catalog, a catalog population study, and three stacked Galactic catalog searches. The most significant point in the northern hemisphere from scanning the sky is coincident with the Seyfert II galaxy NGC 1068, which was included in the source catalog search. The excess at the coordinates of NGC 1068 is inconsistent with background expectations at the level of 2.9σ after accounting for statistical trials from the entire catalog. The combination of this result along with excesses observed at the coordinates of three other sources, including TXS 0506+056, suggests that, collectively, correlations with sources in the northern catalog are inconsistent with background at 3.3σ significance. The southern catalog is consistent with background. These results, all based on searches for a cumulative neutrino signal integrated over the 10 years of available data, motivate further study of these and similar sources, including time-dependent analyses, multimessenger correlations, and the possibility of stronger evidence with coming upgrades to the detector.

9.
Z Rheumatol ; 79(2): 160-167, 2020 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-31388735

RESUMO

BACKGROUND: The initial presentation of patients with symptoms indicative of a rheumatic disease is in most cases not directly to a rheumatologist. This study evaluated the following questions: I. Which medical specialists refer patients to a department of rheumatology? II. Evaluation of the accordance of the presumptive referral diagnosis and the final diagnosis by a rheumatologist. METHODS: A total of 947 patients (279 men and 668 women) who initially presented to a university hospital for rheumatological diagnostics were included in the study. The referring medical specialist fields were identified. Furthermore, a kappa analysis was performed to evaluate the accordance of the presumptive referral diagnosis and the final diagnosis generated after a rheumatological evaluation of the patients. RESULTS: Of the referrals 73% were initiated by general practitioners or internists functioning as general practitioners. The other referrers were 5% specialists in internal medicine (excluding rheumatology), 4% orthopedic/trauma surgeons, 1% other surgeons and 4% other specialist fields. A rheumatological diagnosis was made in 58% of the patients and rheumatological inflammatory joint diseases (26%), collagenosis (14%) and vasculitides (5%) were the most frequently diagnoses. The accordance of the presumptive diagnosis of the general practitioners and the final diagnosis after rheumatological evaluation was a kappa coefficient of κ = 0.304. Lower kappa values were evaluated for orthopedic surgeons (κ = 0.277) and other specialists (κ = 0.200). CONCLUSION: The referrals to a rheumatology institution were frequently initiated by general practitioners and internists functioning as general practitioners. In this context the presumptive diagnosis of general practitioners showed a low accordance with the final rheumatological diagnosis. In contrast, a detailed presumptive diagnosis is desirable for optimal use of the limited resources for rheumatological care.


Assuntos
Encaminhamento e Consulta , Doenças Reumáticas , Reumatologia , Feminino , Humanos , Medicina Interna , Masculino , Encaminhamento e Consulta/estatística & dados numéricos , Doenças Reumáticas/diagnóstico , Reumatologistas
10.
Clin Radiol ; 72(9): 754-763, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28545684

RESUMO

AIM: To evaluate different magnetic resonance imaging (MRI) sequences for diagnosis of pulmonary manifestations of cystic fibrosis (CF) in comparison to chest computed tomography (CT), including an extended outcome analysis. MATERIALS AND METHODS: Twenty-eight patients with CF (15 male, 13 female, mean age 30.5±9.4 years) underwent CT and MRI of the lung. MRI (1.5 T) included different T2- and T1-weighted sequences: breath-hold HASTE (half Fourier acquisition single shot turbo spin echo) and VIBE (volumetric interpolated breath-hold examination, before and after contrast medium administration) sequences and respiratory-triggered PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) sequences with and without fat signal suppression, and perfusion imaging. CT and MRI images were evaluated by the modified Helbich and the Eichinger scoring systems. The clinical follow-up analysis assessed pulmonary exacerbations within 24 months. RESULTS: The highest concordance to CT was achieved for the PROPELLER sequences without fat signal suppression (concordance correlation coefficient CCC of the overall modified Helbich score 0.93 and of the overall Eichinger score 0.93). The other sequences had the following concordance: PROPELLER with fat signal suppression (CCCs 0.91 and 0.92), HASTE (CCCs 0.87 and 0.89), VIBE (CCCs 0.84 and 0.85) sequences. In the outcome analysis, the combined MRI analysis of all five sequences and a specific MRI protocol (PROPELLER without fast signal suppression, VIBE sequences, perfusion imaging) reached similar correlations to the number of pulmonary exacerbations as the CT examinations. CONCLUSION: An optimum lung MRI protocol in patients with CF consists of PROPELLER sequences without fat signal suppression, VIBE sequences, and lung perfusion analysis to enable high diagnostic efficacy and outcome prediction.


Assuntos
Fibrose Cística/diagnóstico por imagem , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Science ; 380(6652): 1338-1343, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37384687

RESUMO

The origin of high-energy cosmic rays, atomic nuclei that continuously impact Earth's atmosphere, is unknown. Because of deflection by interstellar magnetic fields, cosmic rays produced within the Milky Way arrive at Earth from random directions. However, cosmic rays interact with matter near their sources and during propagation, which produces high-energy neutrinos. We searched for neutrino emission using machine learning techniques applied to 10 years of data from the IceCube Neutrino Observatory. By comparing diffuse emission models to a background-only hypothesis, we identified neutrino emission from the Galactic plane at the 4.5σ level of significance. The signal is consistent with diffuse emission of neutrinos from the Milky Way but could also arise from a population of unresolved point sources.

12.
J Environ Qual ; 41(4): 1253-62, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22751069

RESUMO

The German insignificance thresholds (GFS) for groundwater, derived with an added risk approach, will soon be adopted as trigger values for percolation water entering groundwater. The physicochemical properties of the vadose zone differ considerably from those of groundwater, which may lead to difficulties in the applicability of groundwater-derived GFS to percolation water. To test the applicability of the GFS to percolation water regarding the concentration level and the field-scale variability, 46 sites in Northern Germany were sampled, including arable land, grassland, and forest, situated on three spatially dominant parent materials: sand, glacial loam, and loess. Concentrations of As, Ba, Cd, Co, Cr, Cu, Mo, Ni, Pb, Sb, Sn, V, Zn, and F were analyzed in percolation water from the transition between the unsaturated to the saturated zone. We compared median and 90th percentile values of the background concentrations with the GFS. In more than 10% of all samples, background concentrations of Cd, Co, Ni, V, or Zn exceeded the GFS. We evaluated the applicability of the GFS on field-scale medians of background concentrations taking field-scale interquartile distance and the bootstrap percentile confidence interval of the field scale median of trace element background concentrations into consideration. Statements about exceedance or nonexceedance of GFS values could only be made with acceptable statistical uncertainty (α ≤ 0.1) when operational median concentrations were about one third higher or lower than the corresponding GFS.


Assuntos
Monitoramento Ambiental , Água Subterrânea/química , Oligoelementos/química , Ecossistema , Alemanha , Solo/química
13.
Radiologe ; 52(4): 366-72, 2012 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-22526116

RESUMO

BACKGROUND: A recently developed CAD software which highlights intravascular thrombotic structures from multislice computed tomography (MSCT) data was tested regarding feasibility, interobserver reliability and effect on radiology reports. MATERIAL AND METHODS: The CAD system ImageChecker® CT-Lung was tested in a randomized double-blinded study on 160 MSCT datasets (standardized technical conditions) performed for suspected pulmonary embolism (PE). The CAD data and images were analyzed by three radiologists in an independent and blinded fashion. RESULTS: The data from all 160 cases could be analyzed and 604 CAD prompts were set. Using the CAD analysis significantly more PEs were found in the peripheral pulmonary arterial circulation than described in the initial report. In 38 cases the 3 radiologists in consensus scored the images with the CAD adjunct as PE positive in peripheral vessels, which were initially reported as negative. Despite differences in the evaluation between two radiologists the amended assessment of the imaging data using the CAD softwear was reliable. There was a significant correlation between D-dimer values and the number of embolic structures detected by the CAD analysis. CONCLUSION: The recently developed CAD system is a useful adjunct as second reader to detect subtle emboli in peripheral vessels of MSCT datasets.


Assuntos
Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Adulto Jovem
14.
Science ; 378(6619): 538-543, 2022 11 04.
Artigo em Inglês | MEDLINE | ID: mdl-36378962

RESUMO

A supermassive black hole, obscured by cosmic dust, powers the nearby active galaxy NGC 1068. Neutrinos, which rarely interact with matter, could provide information on the galaxy's active core. We searched for neutrino emission from astrophysical objects using data recorded with the IceCube neutrino detector between 2011 and 2020. The positions of 110 known gamma-ray sources were individually searched for neutrino detections above atmospheric and cosmic backgrounds. We found that NGC 1068 has an excess of [Formula: see text] neutrinos at tera-electron volt energies, with a global significance of 4.2σ, which we interpret as associated with the active galaxy. The flux of high-energy neutrinos that we measured from NGC 1068 is more than an order of magnitude higher than the upper limit on emissions of tera-electron volt gamma rays from this source.

15.
Opt Express ; 18(3): 2296-301, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20174058

RESUMO

Mesa-structuring of InGaAs/InAlAs photoconductive layers is performed employing a chemical assisted ion beam etching (CAIBE) process. Terahertz photoconductive antennas for 1.5 microm operation are fabricated and evaluated in a time domain spectrometer. Order-of-magnitude improvements versus planar antennas are demonstrated in terms of emitter power, dark current and receiver sensitivity.

16.
Opt Express ; 16(13): 9565-70, 2008 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-18575523

RESUMO

The worldwide first all-fiber THz time-domain spectrometer for operation at 1.5 microm is presented. Applications up to 3 THz are demonstrated. Key devices are photoconductive antennas based on novel LT InGaAs/InAlAs multi-layer structures.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Modelos Teóricos , Espectrofotometria Infravermelho/instrumentação , Telecomunicações/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Micro-Ondas , Espalhamento de Radiação , Espectrofotometria Infravermelho/métodos
17.
Osteoporos Int ; 19(9): 1291-9, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18299786

RESUMO

UNLABELLED: Osteopenia of the cortical and trabecular bone partition is a common finding after immobilisation. Digital X-ray radiogrammetry (DXR) seems to quantify cortical demineralisation caused by circular saw amputation already few days after accident. INTRODUCTION: The study analyses the extent of demineralisation caused by immobilisation in patients with digital amputation after a circular saw injury, and elucidates the period of time which discloses a significant deprivation of bone mineral density estimated at the metacarpalia II-IV using DXR. METHODS: Twenty-eight patients with digital amputations underwent measurements of bone mineral density, cortical thickness, bone width and metacarpal index using DXR-technology in a follow-up up to 902 days. RESULTS: The data showed a significant decline of bone mineral density (-10.47%), the metacarpal index (-4.38%), the bone width (-12.06%) and the cortical thickness (-7.04%) after trauma-related amputation. The cortical demineralisation of the metacarpals could already be revealed in two patients after the second day, according to the amputation of phalanges (-3.65%). CONCLUSIONS: The inhibition of the periosteal bone formation detected by DXR-technique seems to be a specific finding caused by amputation, which thus differs from normal age-related (i.e., endosteal) bone loss and from demineralisation following acute immobilisation (i.e., trabecular osteopenia).


Assuntos
Amputação Traumática/complicações , Densidade Óssea , Doenças Ósseas Metabólicas/etiologia , Traumatismos dos Dedos/complicações , Falanges dos Dedos da Mão/fisiopatologia , Absorciometria de Fóton/métodos , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Amputação Traumática/diagnóstico por imagem , Amputação Traumática/fisiopatologia , Doenças Ósseas Metabólicas/diagnóstico por imagem , Doenças Ósseas Metabólicas/fisiopatologia , Traumatismos dos Dedos/diagnóstico por imagem , Traumatismos dos Dedos/fisiopatologia , Falanges dos Dedos da Mão/diagnóstico por imagem , Humanos , Imobilização/fisiologia , Estudos Longitudinais , Pessoa de Meia-Idade , Adulto Jovem
18.
Nat Commun ; 8: 15197, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28504268

RESUMO

The electrodynamics of topological insulators (TIs) is described by modified Maxwell's equations, which contain additional terms that couple an electric field to a magnetization and a magnetic field to a polarization of the medium, such that the coupling coefficient is quantized in odd multiples of α/4π per surface. Here we report on the observation of this so-called topological magnetoelectric effect. We use monochromatic terahertz (THz) spectroscopy of TI structures equipped with a semitransparent gate to selectively address surface states. In high external magnetic fields, we observe a universal Faraday rotation angle equal to the fine structure constant α=e2/2hc (in SI units) when a linearly polarized THz radiation of a certain frequency passes through the two surfaces of a strained HgTe 3D TI. These experiments give insight into axion electrodynamics of TIs and may potentially be used for a metrological definition of the three basic physical constants.

20.
Stroke ; 36(3): e20-2, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15692119

RESUMO

BACKGROUND AND PURPOSE: The pathophysiology of hypoglycemia shares a common mechanism with cerebral ischemia, but so far, little is known regarding MRI of humans with hypoglycemia. METHODS: We report a patient with left hemiparesis and dysarthria associated with a blood glucose level of 1.7 mmol/L. The patient recovered completely after glucose infusion. RESULTS: The initial diffusion-weighted imaging (DWI) showed increased signal intensities and a reduction of apparent diffusion coefficient (ADC) values localized in the corpus callosum (splenium) and asymmetrically in the corona radiata. After 48 hours, follow-up revealed complete recovery of DWI and ADC signal abnormalities. CONCLUSIONS: To our knowledge, this is the first presentation of a case with transient hypoglycemia-induced focal neurological deficits revealing completely reversible MRI changes in terms of disturbed DWI and ADC with a peculiar as yet undescribed topography.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Hipoglicemia/complicações , Paresia/sangue , Paresia/etiologia , Idoso , Glicemia/metabolismo , Glicemia/fisiologia , Disartria/sangue , Disartria/etiologia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA