RESUMO
The orbital complications of endoscopic sinus surgery, including diplopia and ocular motility restriction, are mainly caused by direct injury to the orbital structures. These complications are rare, but can have catastrophic consequences. Symptoms occur immediately after surgery in most cases. The authors encountered an unusual case of delayed ocular motility restriction after endoscopic sinus surgery in a patient with old medial wall fracture, without direct orbital injury during the procedure. A 77-year-old man with an old medial wall fracture of the right orbit underwent endoscopic sinus surgery for chronic pansinusitis. He complained mild diplopia on right lateral gaze after 2 weeks, which gradually worsened. After 2 months, he exhibited severe lateral gaze movement impairment in the right eye and finally underwent surgical exploration. His symptoms improved after adhesiolysis of the overgrown ethmoid sinus mucosa and periorbital tissue. The authors reported this unusual case and discussed the possible mechanism underlying ocular motility restriction.
Assuntos
Fraturas Orbitárias/cirurgia , Sinusite/complicações , Idoso , Diplopia/etiologia , Seio Etmoidal , Humanos , Masculino , Transtornos da Motilidade Ocular/etiologia , Fraturas Orbitárias/complicações , Fraturas Orbitárias/diagnóstico por imagem , Tomografia Computadorizada por Raios XRESUMO
Upper airway collapse can be effectively dealt with positive airway pressure (PAP), and patient adherence is considered as a major determining factor for success of PAP therapy. This study was performed to determine the potential factors affecting the adherence to PAP in patients with OSA by using polysomnography (PSG) parameters recorded for diagnosis of OSA. The data of 158 patients between December 2018 and July 2021 were collected. They were prescribed with PAP and used the device during the adaptation period for 90 days. They were categorized into adherent and non-adherent group according to the criteria of good adherence as use of PAP ≥ 4 h per night on 70% of nights. Demographic, clinical characteristics, and PSG results were reviewed. Among 158 patients engaged in PAP therapy, 121 patients (76.6%) met the criteria of good adherence. No significant differences were found in good adherence rate regarding demographic and clinical characteristics. None of the polysomnographic factors showed significant differences between adherent and non-adherent groups. However, the percentage of sleep time on back in the adherent group was significantly higher than non-adherent group (p = 0.041). The cut-off value was determined to be 41.45% (95% confidence interval 0.43 to 0.79) by receiver operating characteristic curve analysis and the odds ratio was calculated as 2.97. Only the percentage of sleep time on back appeared to be polysomnographic predictor for identifying good adherence to PAP therapy in OSA patients. However, the conclusions may be limited in generalization due to the small sample size.