Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 39(23): 8091-8099, 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37267477

RESUMO

Increased gas adsorption in a series of post-synthetically modified metal-organic frameworks (MOFs) of the type HKUST-1 was achieved by the partial cation exchange process. Manipulation of post-synthetic conditions demonstrates high tunability in the site substitution and gas adsorption properties during the dynamic equilibrium process. In this work, post-synthetic modification of Cu3(BTC)2 is carried on by exposure to TM2+ solutions (TM = Mn, Fe, Co, Ni) at different time intervals. The crystal structure, composition, and morphology were studied by powder X-ray diffraction, Fourier-transform infrared spectroscopy, inductively coupled plasma optical emission spectroscopy, and scanning electron microscopy. Structural analysis supports the retention of the crystal structure and partial substitution of the Cu metal nodes within the framework. A linear increase in the transmetalation process is observed with Fe and Co with a maximum percentage of 39 and 18%, respectively. Conversely, relatively low cation exchange is observed with Mn having a maximum percentage of 2.40% and Ni with only 2.02%. Gas adsorption measurements and surface area analysis were determined for each species. Interestingly, (Cu/Mn)3(BTC)2 revealed the highest CO2 adsorption capacity of 5.47 mmol/g, compared to 3.08 mmol/g for Cu3(BTC)2. The overall increased gas adsorption can be attributed to the formation of defects in the crystal structure during the cation exchange process. These results demonstrate the outstanding potential of post-synthetic ion exchange as a general approach to fine-tuning the physical properties of existing MOF architectures.

2.
Minim Invasive Ther Allied Technol ; 23(3): 144-51, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24359311

RESUMO

INTRODUCTION: LigaSure™ was developed as an alternative to suture ligatures, hemoclips and staplers for ligating vessels and tissue bundles. The aim of the present study was to determine whether LigaSure can be used as a welding instrument in the performance of laparoscopic sleeve gastrectomy. MATERIAL AND METHODS: Gastric specimens were assigned into four groups. Group 1 - specimens remained with the staple line intact. Group 2 - the staple line was oversewn. Group 3 - the staple line was resected with LigaSure. Group 4 - staple line was resected with LigaSure and the seal was oversewn. In all specimens the pressure tolerance was assessed using a portable sensor. RESULTS: In group 1 the leak pressure was 34.7 ± 11.7 whereas in group 2 specimens the pressure increased three-fold (101.9 ± 21.4). The LigaSure seal alone (group 3) achieved a mean pressure of 13.7 mmHg. However, in group 4 there was an exponential increase on their burst strength up to 142 mmHg (p = 0.0005). CONCLUSION: According to our results, LigaSure could be used to perform laparoscopic sleeve gastrectomy with reduction of staple-line bleeding and, when reinforced with a running suture, it achieves a strength that approaches that of staples plus oversewing.


Assuntos
Gastrectomia/métodos , Laparoscopia/métodos , Grampeamento Cirúrgico/métodos , Desenho de Equipamento , Gastrectomia/instrumentação , Humanos , Laparoscopia/instrumentação , Pressão , Suturas , Resistência à Tração
3.
Trauma Case Rep ; 42: 100718, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36281425

RESUMO

Nowadays, massive segmental bone defects represent a surgical challenge for trauma surgeons. Most of these injuries appear in the context of high-energy trauma, not only significantly affecting the bones, but also involving severe injuries of the adjacent soft tissues. For these reasons, their treatment requires complex reconstruction surgeries. There are multiple techniques to treat bone defects, bone transport being one of the most widely used. Historically, external fixators (monolateral and circular) have been and still are the gold standard for performing this technique, although they are not exempt from complications. By means of specific intramedullary nails for bone transport, it is possible to minimize the complications of external fixation, allowing large tibial bone defects to be treated through distraction osteogenesis (all-internal system), which is favoured by early weight bearing.

4.
Rev. méd. IMSS ; 32(2): 179-82, mar.-abr. 1994.
Artigo em Espanhol | LILACS | ID: lil-176870

RESUMO

La relación médico-paciente es uno de los instrumentos más útiles con los que cuenta el médico en su tarea de mantener o restablecer la salud, desafortunadamente su uso adecuado ha quedado poco a poco olvidado, con la consecuente deshumanización de la atención médica. Se propone un abordaje basado en la teoría de la comunicación humana para retomar los aspectos esenciales que nos permitan establecer una relación adecuada que satisfaga los objetivos tanto del paciente como del médico


Assuntos
Qualidade da Assistência à Saúde/tendências , Relações Médico-Paciente , Satisfação do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA