RESUMO
BACKGROUND: Stroke and transient ischemic attack after transcatheter aortic valve replacement results in significantly higher morbidity and mortality. Severe carotid artery disease may be a contributing factor to this increased risk. We report our technique and outcomes of combined carotid endarterectomy (CEA) with transcatheter aortic valve replacement (TAVR). METHODS: From March 2013 to November 2017 a total of 753 TAVRs were performed at our institution for symptomatic severe aortic stenosis. Of this group, 16 patients underwent concomitant TAVR and CEA. A retrospective review was performed to assess risk, outcomes, and short-term survival. RESULTS: Sixteen patients underwent concomitant CEA/TAVR procedures for severe carotid and severe aortic stenosis. The mean Society of Thoracic Surgeons (STS) Risk Score was 7.0 ± 4.7. All patients had severe carotid artery stenosis and aortic stenosis. Nine patients had a transfemoral TAVR approach and eight patients had a transapical TAVR approach. The mean length of stay was 6.4 ± 3.7 days. At 30 days there were no cerebrovascular events and no mortalities. CONCLUSIONS: The use of concomitant CEA and TAVR in patients with severe aortic stenosis and severe carotid stenosis can be done safely without increased risk of complications. This approach may reduce the risk of stroke associated with TAVR in appropriately selected patients.
Assuntos
Estenose da Valva Aórtica/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Ataque Isquêmico Transitório/prevenção & controle , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Tempo de Internação , Masculino , Estudos Retrospectivos , Risco , Medição de Risco , Índice de Gravidade de Doença , Sobrevida , Resultado do TratamentoRESUMO
Ventricular tachycardia (VT) in the setting of left ventricular assist device (LVAD) therapy has been well described. We present a case of incessant ventricular tachycardia resulting in severe right ventricular (RV) failure and subsequent left ventricular (LV) cavity obliteration, which in turn diminished the feasibility of initial attempt at VT ablation.
Assuntos
Ablação por Cateter , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Taquicardia Ventricular/terapia , Idoso , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Taquicardia Ventricular/complicações , Falha de TratamentoRESUMO
BACKGROUND: Left heart mechanical circulatory support (MCS) through the left chest via the pulmonary vein and descending thoracic aorta is a good option for patients with an inaccessible anterior mediastinum and/or poor peripheral access. MATERIALS AND METHODS: We report the case of a 19-year-old small female with a newly discovered bulky primary mediastinal diffuse large B-cell lymphoma (PMBL) who developed refractory inverted Takotsubo cardiomyopathy (TC) with cardiogenic shock. RESULTS: Temporary MCS was implemented in order to stabilize the patient and proceed with a chemotherapy treatment. Given the patient's oncologic "frozen" mediastinum and the presence of poor peripheral arterial access, the left heart temporary MCS was successfully implanted through a left mini-thoracotomy via the left inferior pulmonary vein and descending thoracic aorta. CONCLUSIONS: This is the first report of temporary MCS to treat inverted TC and diffuse PMBL.
Assuntos
Derivação Cardíaca Esquerda , Linfoma Difuso de Grandes Células B/complicações , Neoplasias do Mediastino/complicações , Cardiomiopatia de Takotsubo/cirurgia , Feminino , Derivação Cardíaca Esquerda/métodos , Humanos , Cardiomiopatia de Takotsubo/etiologia , Toracotomia , Adulto JovemRESUMO
OBJECTIVES: Acute refractory cardiogenic shock with early multisystem organ failure has a poor outcome without mechanical circulatory support. We review our experience with emergent peripheral cardiopulmonary support as a bridge to decision in these patients. METHODS: A retrospective review from January 2009 through December 2010 was conducted of 26 consecutive adult patients at a single institution with acute refractory cardiogenic shock who underwent salvage peripheral cardiopulmonary support. RESULTS: There were 18 men and 8 women with a mean age of 54 years (range 18 to 76). Indications for support: acute myocardial infarction (n = 16), decompensated chronic heart failure (n = 2), refractory arrhythmic arrest (n = 3), acute valvular pathology (n = 4), and unknown (n = 1). Patients with primary postcardiotomy shock were excluded. Median duration of support was 3 days (range 1 to 14). Decisions included: withdraw of support (n = 4), recovery (n = 5), and bridge to a procedure (n = 17). The procedures were percutaneous coronary intervention (n = 4), left ventricular assist device (n = 9), heart transplantation (n = 1), and miscellaneous cardiac surgery (n = 3). Overall survival to discharge was 65%. In the recovery and bridge to a procedure group, 78% were discharged from the hospital and survival at three months was 72%. CONCLUSIONS: Salvage peripheral cardiopulmonary support is a useful tool to rapidly stabilize acute refractory cardiogenic shock permitting an assessment of neurologic and end-organ viability.
Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Terapia de Salvação/métodos , Choque Cardiogênico/terapia , Adolescente , Adulto , Idoso , Algoritmos , Técnicas de Apoio para a Decisão , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxigenadores de Membrana , Estudos Retrospectivos , Terapia de Salvação/instrumentação , Terapia de Salvação/mortalidade , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Taxa de Sobrevida , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Jehovah's Witnesses (JW) are a Christian faith, with an estimated 1.1 million members in the United States, well recognized for their refusal of blood and blood products. JW may not be considered for cardiac surgery due to perceived higher risks of morbidity and mortality. This study reviews our contemporary strategies and experience with JW undergoing routine and complex cardiac surgery. METHODS: From November 2001 to April 2010, 40 JW were referred for cardiac surgery at a single quaternary referral institution. A retrospective analysis of demographic data, perioperative management, and clinical outcomes was examined. Published validated clinical risk calculator and model for prediction of transfusion were used to identify high-risk patients (risk of mortality >6% or probability of transfusion >0.80). RESULTS: The mean age was 70 (± 9.5) years with 21 men and 19 women. Patients were classified as high risk (45%, n = 18) and low risk (55%, n = 22) with demographics and comorbidities listed in Table 2. Operative procedures included: isolated coronary artery bypass grafting (CABG) (n = 19), isolated valve replacement/repair (n = 7), valve/CABG (n = 7), reoperative valve replacement (n = 4), reoperative CABG (n = 2), valve/ascending aorta replacement (n = 1), and CABG/ascending aorta replacement (n = 1). All JW were evaluated by The Department of Bloodless Medicine to individually define acceptable blood management strategies. The mean preoperative hemoglobin was 14.1 g/dL (±1.6). Overall mortality was 5% (n = 2) all of which were in the high-risk group. DISCUSSION: Using a multidisciplinary approach to blood management, JW can safely undergo routine and complex cardiac surgery with minimal morbidity and mortality.
Assuntos
Procedimentos Cirúrgicos Cardíacos/psicologia , Cardiopatias/cirurgia , Testemunhas de Jeová/psicologia , Guias de Prática Clínica como Assunto , Idoso , Transfusão de Sangue , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Seguimentos , Cardiopatias/psicologia , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Estados UnidosRESUMO
Left ventricular assist devices (LVADs) have consistently and successfully improved mortality associated with end-stage heart failure. However, the definition of an "optimal" outcome post LVAD as a benchmark remains debatable. We retrospectively examined patients in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) between 2012 and 2016 to assess 1 year post-LVAD "optimal outcome" defined as a patient who was alive on device or transplanted, New York Heart Association functional class I/II, had no more than 2 hospitalizations at year 1, and no major adverse event. We identified the features predicting a nonoptimal outcome at 1 year. Finally, we focused on 3 years outcomes in patients implanted as destination therapy. Of the 12,566 patients in INTERMACS who received an LVAD, only 3,495 (27.8%) met our definition of optimal LVAD outcome at 1 year. These patients tended to be younger, male, and were four times more likely to be supported as bridge to transplantation. For those with optimal outcome at year 1, their chances of long-term survival were better than those who were alive at year 1, but did not meet criteria for an optimal outcome. In the destination therapy population, only 14% of patients met the definition of an optimal outcome at 3 years. Despite significantly improved survival in patients with end-stage heart failure treated with LVAD therapy, majority patients had nonoptimal outcomes at 1 and 3 years post implant, by our definition. There is a pressing need to create a benchmark to define optimal outcomes post LVAD, both in our clinical trials and practice.
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Resultado do Tratamento , Adulto , Feminino , Insuficiência Cardíaca/mortalidade , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de RiscoRESUMO
Severe aortic stenosis (AS) is associated with left ventricular (LV) hypertrophy and diastolic dysfunction (LVDD). Due to positive impact on transvalvular hemodynamics, transcatheter aortic valve replacement (TAVR) is expected to improve LV remodeling, LVDD and heart failure (HF)-related quality-of-life (QoL). We identified patients with severe AS and LV ejection fraction (LVEF) ≥ 50% who underwent TAVR. We reviewed pre-procedure, 1-month and 1-year post-TAVR transthoracic echocardiograms to assess LV volumetric changes and diastolic function. QoL was assessed by the Kansas City Cardiomyopathy Questionnaire (KCCQ). In 171 patients studied, we found significant improvement in LV mass index (LVMI), LV end-systolic diameter and LV end-diastolic diameter from baseline to 1-month to 1-year post-TAVR. Predictors of LVMI regression included greater change from baseline in mean aortic valve (AV) gradient, peak AV velocity, and improvements in septal and lateral e' velocities and E/e' post-TAVR. The percentage of patients with ≥ grade 2 LVDD decreased from 65% to 53% at 1-month and 49% at 1-year. A significant improvement in symptomatology, as reported by KCCQ score was also noted. There is conceivable reverse LV remodeling post-TAVR, impacted by improvements in mean AV gradient, peak AV velocity, E/e', medial and lateral e' velocities, which occurs immediately post-TAVR and persists up to 1-year post-operatively. This is associated with concomitant improvement in LVDD and HF-related QoL as demonstrated by KCCQ scores.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Hipertrofia Ventricular Esquerda/fisiopatologia , Qualidade de Vida , Volume Sistólico , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Diástole , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Recuperação de Função Fisiológica , Estudos Retrospectivos , Índice de Gravidade de Doença , Inquéritos e Questionários , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: The use of valve-in-valvetranscatheter aortic valve replacement (VIV-TAVR) in degenerated aortic bioprosthesis has been increasing, but the Food and Drug Administration approval is limited to high-risk patients. We analyzed the real-world experience of SAPIEN 3 VIV-TAVR, especially in lower-risk patients, based on the Society of Thoracic Surgeons (STS) score. METHODS: All transfemoral VIV-TAVR with the SAPIEN 3 and Ultra valves between June 2015 and January 2020 were identified using the STS/American College of Cardiology Transcatheter Valve Therapies Registry. Patients were grouped based on STS score (low score: <4%, intermediate score: 4%≤ and≤8%, high score: >8%). Propensity-matched (1:3) analysis was conducted to compare to patients undergoing native TAVR. RESULTS: Of 145 917 SAPIEN 3 TAVR patients, 4460 (3%) underwent transfemoral VIV-TAVR with available baseline STS data in 4276 patients. Average age was 73.9±11.2, 66.4% were male, and the mean STS score was 6.9±6.0%. Overall 30-day mortality was 2.4% (observed to expected ratio, 0.33), and 1-year mortality was 10.8%. 30-day mortality and observed to expected ratio were 0.9% and 0.32 in low-score, 2.2% and 0.38 in the intermediate-score, and 4.3% and 0.31 in the high-score group. Based on propensity-matched analysis, 30-day mortality was similar and 1-year mortality was lower in VIV compared to native TAVR among all risk groups. When the groups were analyzed based on the Heart Team risk stratification using high-risk and nonhigh risk, the findings remained consistent. CONCLUSIONS: In this real-world study, VIV-TAVR had excellent 30-day and 1-year outcomes, especially in lower-risk patients. These findings may suggest the feasibility and expansion of VIV-TAVR in lower-risk patients. However, long-term follow-up continues to be crucial.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Cirurgiões , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Aberrant right subclavian artery (ARSA) is the most common congenital arch anomaly, which can be complicated by aneursymal dilation at its ostium. We describe a successful repair of an ARSA with a three-stage operative procedure using a left carotid to subclavian bypass, coiling of the ARSA, and thoracic endovascular aortic repair with long-term clinical and radiographic follow-up.
Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Artéria Subclávia/cirurgia , Idoso , Angiografia , Aorta Torácica/patologia , Implante de Prótese Vascular/instrumentação , Artéria Braquial , Feminino , Humanos , Artéria Subclávia/anormalidades , Artéria Subclávia/patologia , Fatores de Tempo , Resultado do Tratamento , Malformações Vasculares/patologia , Malformações Vasculares/cirurgiaRESUMO
BACKGROUND: Less invasive techniques for left ventricular assist device implantation have been increasingly prevalent over past years and have been associated with improved clinical outcomes. The procedural economic impact of these techniques remains unknown. We sought to study and report economic outcomes associated with the thoracotomy implantation approach. METHODS: The LATERAL clinical trial evaluated the safety and efficacy of the thoracotomy approach for implantation of the HeartWare centrifugal-flow ventricular assist device system (HVAD). We collected UB-04 forms in parallel to the trial, allowing analysis of index hospitalization costs. All charges were converted to costs using hospital-specific cost-to-charge ratios and were subsequently compared with Medicare cost data for the same period (2015-2016). Because thoracotomy implants were off-label for all left ventricular assist devices during that period, the Medicare cohort was assumed to consist predominately of traditional sternotomy patients. RESULTS: Thoracotomy patients demonstrated decreased costs compared with sternotomy patients during the index hospitalization. Mean total index hospitalization costs for thoracotomy were $204,107 per patient, corresponding to 21.6% reduction (P < .001) and $56,385 savings per procedure compared with sternotomy. Across almost all cost categories, thoracotomy implants were less costly. CONCLUSIONS: In LATERAL, a clinical trial evaluating the safety and efficacy of the thoracotomy approach for HVAD, costs were lower than those reported in Medicare patient claims occurring over the same period. Because Medicare data can be presumed to consist of predominately sternotomy procedures, thoracotomy appears less expensive than traditional sternotomy.
Assuntos
Custos e Análise de Custo , Coração Auxiliar , Implantação de Prótese/economia , Implantação de Prótese/métodos , Esternotomia/economia , Toracotomia/economia , Adulto , Idoso , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Medicare , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Estados UnidosRESUMO
BACKGROUND: In a randomized controlled trial (MOMENTUM 3), the HeartMate 3 (HM3) fully magnetically levitated centrifugal-flow left ventricular assist device (LVAD) demonstrated superiority over the HeartMate II (HMII) axial-flow LVAD. These findings were driven by hemocompatibility-related outcomes, but infection-related outcomes were not altered by device choice. In this trial-level analysis, we analyzed the clinical patterns of infection-related outcomes over 2 years of support. METHODS: In MOMENTUM 3, 1,020 patients were implanted with either the HM3 (nâ¯=â¯515) or HMII (nâ¯=â¯505) pump. Clinical characteristics and morbidity- and mortality-related outcomes were evaluated to identify predictors associated with major infectious complications, using univariable and multivariable models. RESULTS: The cumulative number of infections at 2 years was 1,213 (634 HM3 and 579 HMII), and major infection occurred in 58% of patients with the HM3 and 56% of patients with the HMII (pâ¯=â¯0.57). Infections of a local nature unrelated to pump components were most common (nâ¯=â¯681/1,213; 56%), followed by driveline-associated infection (nâ¯=â¯329/1,213; 27%), sepsis (nâ¯=â¯194/1,213; 16%), and other events (nâ¯=â¯9/1,213; 0.7%). Bacterial pathogens were implicated in 806 of 1,213 events (66%); significant predictors of infection included sex (women vs men; hazard ratio [HR]: 1.38, pâ¯=â¯0.003), pre-implant use of intra-aortic balloon pump (HR: 1.33, pâ¯=â¯0.02), pre-implant history of cardiac surgery (HR: 1.28, pâ¯=â¯0.01), and body mass index ≥ 30 (HR: 1.40, p < 0.0001). Most deaths in those with infection occurred owing to non-infectious causes. CONCLUSION: Infection is the most common adverse effect in patients implanted with contemporary continuous-flow LVADs, with most such events unrelated to the pump or its peripheral components. Whether chronic mechanical circulatory devices confer an immunomodulatory effect pre-disposing to infection warrants closer scrutiny to understand and ameliorate this morbidity.
Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/etiologia , Fatores de Risco , Fatores de Tempo , Estados Unidos/epidemiologia , Função Ventricular EsquerdaRESUMO
Bloodstream infection (BSI) is a common complication of left ventricular assist device (LVAD) support and particularly difficult to treat. The presentation is often variable because of altered physiology and augmentation of cardiac output by the device. We studied LVAD recipients at a single institution. Multivariate logistic and Cox (with time-varying parameters) regression were implemented. Of 212 patients, 58% experienced infections. Driveline infection (DLI) affected 31%, with 60% of them having deep-tissue involvement. Sixty-six patients (31%) suffered from 135 BSIs. Systemic inflammatory response syndrome (SIRS) was present in 47% of BSIs at presentation and associated with increased mortality. Right heart failure, destination therapy, Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile, morbid obesity, and deep-DLI were independent risk factors for BSI. The BSI was independently associated with mortality. Bridge-to-transplantation (BTT) patients were more likely to receive transplant if they did not have BSIs. Among 104 BTT patients who received heart transplantation, development of BSI was associated with shorter time-to-transplantation. Diagnosis of BSI poses diagnostic and prognostic challenges because of the hemodynamic profile of LVAD patients who may not mount the expected physiologic response to sepsis. Although SIRS criteria lack sensitivity in the LVAD population, SIRS signifies increased risk for death. Deep DLI was the strongest predictor of BSI. Despite the upgrade in listing status of BTT-LVADs with BSIs and shorter time-to-transplantation, BSI remain a major cause of mortality. BSIs are associated with significant mortality and should be regarded as a serious complication, similar to pump thrombosis and stroke.
Assuntos
Coração Auxiliar/efeitos adversos , Sepse/diagnóstico , Sepse/etiologia , Adulto , Feminino , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Sepse/mortalidadeRESUMO
Current risk stratification models to predict outcomes after a left ventricular assist device (LVAD) are limited in scope. We assessed the performance of Bayesian models to stratify post-LVAD mortality across various International Registry for Mechanically Assisted Circulatory Support (INTERMACS or IM) Profiles, device types, and implant strategies. We performed a retrospective analysis of 10,206 LVAD patients recorded in the IM registry from 2012 to 2016. Using derived Bayesian algorithms from 8,222 patients (derivation cohort), we applied the risk-prediction algorithms to the remaining 2,055 patients (validation cohort). Risk of mortality was assessed at 1, 3, and 12 months post implant according to disease severity (IM profiles), device type (axial versus centrifugal) and strategy (bridge to transplantation or destination therapy). Fifteen percentage (n = 308) were categorized as IM profile 1, 36% (n = 752) as profile 2, 33% (n = 672) as profile 3, and 15% (n = 311) as profile 4-7 in the validation cohort. The Bayesian algorithms showed good discrimination for both short-term (1 and 3 months) and long-term (1 year) mortality for patients with severe HF (Profiles 1-3), with the receiver operating characteristic area under the curve (AUC) between 0.63 and 0.74. The algorithms performed reasonably well in both axial and centrifugal devices (AUC, 0.68-0.74), as well as bridge to transplantation or destination therapy indication (AUC, 0.66-0.73). The performance of the Bayesian models at 1 year was superior to the existing risk models. Bayesian algorithms allow for risk stratification after LVAD implantation across different IM profiles, device types, and implant strategies.
Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Medição de Risco/métodos , Algoritmos , Área Sob a Curva , Teorema de Bayes , Bases de Dados Factuais , Desenho de Equipamento , Feminino , Humanos , Cooperação Internacional , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Curva ROC , Sistema de Registros , Estudos Retrospectivos , Estados UnidosRESUMO
BACKGROUND: Despite improvements in pump design and durability, left ventricular assist device patients still suffer from life-threatening complications such as pump thrombosis (PT) and infection, often necessitating device exchange. Surgical exchange from HeartMate II (HM2; Abbott, Pleasanton, CA) to another HM2 is safe and associated with low mortality, but recurrent device thrombosis rates are high. Switching from axial-flow to centrifugal-flow pump, such as the HeartWare ventricular assist device (HVAD; Medtronic, Framingham, MA) may offer certain advantages due to it being a smaller, newer generation device, although there are limited data to support this strategy. Herein, we aimed to assess the surgical approach and feasibility, safety, and outcomes of surgical exchange from HM2 to HVAD. METHODS: We evaluated HM2 patients who underwent device exchange to HVAD due to PT or infection at 4 large-volume left ventricular assist device implant centers. RESULTS: Twenty-four patients underwent HM2 to HVAD exchange due to PT (92%) and refractory infection (8%). Patients were male (75%), white (88%), with ischemic cardiomyopathy (54%), Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) scale level 1-3 (90%), and destination therapy (62%). The majority underwent redo-sternotomy (79%) and the remainder underwent minimally invasive thoracotomy with subcostal approach. The existing HM2 outflow graft was maintained in 79% of cases. Recurrent PT was noted in 9% of patients. Mortality was 8% at 30 days and 33% at 1 year. CONCLUSIONS: The surgical exchange from a HM2 to HVAD is safe and feasible, despite the differences in device specifications and surgical adaptation required. Newer-generation pumps are increasingly considered for exchange in the setting of HM2 device complication, and increasing experience with modified surgical approaches may be valuable in the current era.
Assuntos
Remoção de Dispositivo , Falha de Equipamento , Insuficiência Cardíaca/terapia , Coração Auxiliar , Complicações Pós-Operatórias/cirurgia , Adulto , Idoso , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Reoperação , Estudos RetrospectivosRESUMO
OBJECTIVES: This study investigates the use of a Bayesian statistical models to predict survival at various time points in patients undergoing left ventricular assist device (LVAD) implantation. BACKGROUND: LVADs are being increasingly used in patients with end-stage heart failure. Appropriate patient selection continues to be key in optimizing post-LVAD outcomes. METHODS: Data used for this study were derived from 10,277 adult patients from the INTERMACS (Inter-Agency Registry for Mechanically Assisted Circulatory Support) who had a primary LVAD implanted between January 2012 and December 2015. Risk for mortality was calculated retrospectively for various time points (1, 3, and 12 months) after LVAD implantation, using multiple pre-implantation variables. For each of these endpoints, a separate tree-augmented naïve Bayes model was constructed using the most predictive variables. RESULTS: A set of 29, 26, and 31 pre-LVAD variables were found to be predictive at 1, 3, and 12 months, respectively. Predictors of 1-month mortality included low Inter-Agency Registry for Mechanically Assisted Circulatory Support profile, number of acute events in the 48 h before surgery, temporary mechanical circulatory support, and renal and hepatic dysfunction. Variables predicting 12-month mortality included advanced age, frailty, device strategy, and chronic renal disease. The accuracy of all Bayesian models was between 76% and 87%, with an area under the receiver operative characteristics curve of between 0.70 and 0.71. CONCLUSIONS: A Bayesian prognostic model for predicting survival based on the comprehensive INTERMACS registry provided highly accurate predictions of mortality based on pre-operative variables. These models may facilitate clinical decision-making while screening candidates for LVAD therapy.
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese , Taxa de Sobrevida , Idoso , Teorema de Bayes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos RetrospectivosRESUMO
Increasing evidence suggests that tight glycemic control improves clinical outcomes after coronary artery bypass grafting (CABG). However, the risk for hypoglycemia with insulin often results in less aggressive glycemic control. Glucagon-like peptide-1 (GLP-1) is a naturally occurring peptide whose insulinotropic effects are predicated on the glucose concentration, minimizing the risk for hypoglycemia. This study was conducted to examine whether perioperative treatment with GLP-1 would affect glycemic control and improve hemodynamic recovery after CABG. Twenty patients with coronary heart disease and preserved left ventricular function who were scheduled to undergo CABG were randomized to receive standard therapy at the discretion of the surgeon or treatment with GLP-1 (1.5 pmol/kg/min) as a continuous infusion beginning 12 hours before CABG and continuing for 48 hours. Perioperative hemodynamics, the left ventricular ejection fraction, plasma glucose, and requirements for insulin drips and inotropic support were monitored. There were no differences between groups in the preoperative, postoperative, or 7-day left ventricular ejection fraction (GLP-1 61 +/- 4%, control 59 +/- 3%) or cardiac index at 18 hours (GLP-1 3.0 +/- 0.2 L/min/m(2), control 3.3 +/- 0.4 L/min/m(2)). However, the control group required greater use of inotropic and vasoactive infusions during the 48 hours after the operation to achieve the same hemodynamic result. There were also more frequent arrhythmias requiring antiarrhythmic agents in the control group. GLP-1 resulted in better glycemic control in the pre- and perioperative periods (GLP-1 95 +/- 3 mg/dl, control 140 +/- 10 mg/dl, p =0.02), with 45% less insulin requirements to achieve the same glycemic control in the postoperative period (GLP-1 139 +/- 4 mg/dl, control 140 +/- 3 mg/dl). In conclusion, the perioperative use of GLP-1 achieves better glycemic control and comparable hemodynamic recovery without the requirements for high-dose insulin or inotropes.
Assuntos
Glicemia/análise , Ponte de Artéria Coronária , Peptídeo 1 Semelhante ao Glucagon/uso terapêutico , Hipoglicemiantes/uso terapêutico , Função Ventricular Esquerda/efeitos dos fármacos , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/etiologia , Pressão Sanguínea/efeitos dos fármacos , Cardiotônicos/uso terapêutico , Método Duplo-Cego , Feminino , Peptídeo 1 Semelhante ao Glucagon/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Placebos , Pré-Medicação , Volume Sistólico/efeitos dos fármacos , Resultado do TratamentoRESUMO
Selection is a key determinant of clinical outcomes after left ventricular assist device (LVAD) placement in patients with end-stage heart failure. The HeartMate II risk score (HMRS) has been proposed to facilitate risk stratification and patient selection for continuous flow pumps. This study retrospectively assessed the performance of HMRS in predicting 90 day and 1 year mortality in patients within the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS). A total of 11,523 INTERMACS patients who received a continuous flow LVAD between 2010 and 2015 were retrospectively categorized per their calculated HMRS to predict their 90 day and 1 year risk of mortality. The performance of the score was evaluated by the area under curve (AUC) of the receiver operator characteristic. We also performed multiple regression analysis using variables from the HMRS calculation on the INTERMACS data. The HMRS model showed moderate discrimination for both 90 day and 1 year mortality prediction with AUCs of 61% and 59%, respectively. The predictions had similar accuracy irrespective of whether the pump was axial or centrifugal flow. Multivariable analysis using independent variables used in the original HMRS analysis revealed different set of variables to be predictive of 90 day mortality than those used to calculate HMRS. HMRS predicts both 90 day and 1 year mortality with poor discrimination when applied to a large cohort of LVAD patients. Newer risk prediction models are therefore needed to optimize the therapeutic application of LVAD therapy. Patient selection for appropriate use of LVADs is critical. Currently available risk stratification tools (HMRS) continue to be limited in their ability to accurately predict mortality after LVAD. This study highlights these limitations when applied to a large, comprehensive, multicenter database. HMRS predicts mortality with only modest discrimination when applied to a large cohort of LVAD patients. Better risk stratification tools are needed to optimize outcomes.
Assuntos
Coração Auxiliar/efeitos adversos , Sistema de Registros , Adulto , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Retrospectivos , RiscoRESUMO
OBJECTIVES: This study hypothesized that the presence of residual mitral regurgitation (MR) post-continuous flow (CF) left ventricular assist device (LVAD) implantation based on quantitative assessment would be negatively associated with right ventricular (RV) size and function and clinical outcomes. BACKGROUND: MR is associated with elevated left atrial pressure, secondary pulmonary hypertension and RV dysfunction. Implantation of a LVAD leads to mechanical unloading of the left ventricle and generally improves MR. The clinical significance of residual MR in patients supported with CF LVADs is uncertain. Most studies evaluating the presence of MR in LVAD patients have utilized predominantly qualitative assessments of MR. METHODS: We retrospectively identified patients implanted with CF LVADs at our institution from 2007 to 2013 who had a pre-operative transthoracic echocardiogram (TTE) within 3 months of LVAD implant and who had a post-operative TTE at least 1 month post-LVAD. MR was assessed quantitatively using the ratio of MR color jet area (CJA)/left atrial area (LAA) in apical views. We also compared quantitative RV metrics, hospitalizations, and mortality in patients with and without significant residual MR (defined as MR CJA/LAA >0.2) on post-implantation TTE. RESULTS: Sixty-nine patients were included in this study. Post-LVAD implantation, 55 patients (80%) had mild or less MR (mean MR CJA/LAA 0.08) but 14 (20%) had significant residual MR (mean MR CJA/LAA 0.34). Patients with residual MR had significantly larger RV size (right ventricular end diastolic dimension 49 mm vs. 45 mm; p = 0.04) and worse RV function (tricuspid annular plane systolic excursion 10 mm vs. 12 mm; p = 0.02; and right ventricular fractional area change 29% vs. 34%; p = 0.02). Post-implantation pulmonary artery pressures were higher in patients with residual MR (pulmonary artery systolic 43 mm Hg vs. 35 mm Hg; p = 0.05). In patients with residual MR there was slightly greater posterior displacement of the mitral coaptation point on pre-operative TTE (28 mm vs. 26 mm; p = 0.16) but this difference was not significant. Time from LVAD implantation to first hospitalization was shorter in patients with residual MR (62 days vs. 103 days; p = 0.05) as was time from LVAD implantation to death (80 days vs. 421 days; p = 0.03). CONCLUSIONS: Significant residual MR post-LVAD implantation assessed by a quantitative measure is associated with persistent pulmonary hypertension, worse RV function, and significantly shorter time to hospitalization and death. MR post-LVAD implantation may serve as a surrogate for adverse outcomes post-LVAD implantation.
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Hipertensão Pulmonar/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/patologia , Humanos , Hipertensão Pulmonar/epidemiologia , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/epidemiologia , Tamanho do Órgão , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Direita/epidemiologiaRESUMO
Management for continuous flow left ventricular assist device (LVAD) thrombosis often relies on speculation of individual clinical risk factors and integration of indirect evidence for device dysfunction. There are no comprehensive guidelines for treatment of this serious complication, and most of our current knowledge comes from anecdotal experience or observational study. More data on effective treatment, both with aggressive pharmacologic and device-based interventions, are needed for improving our understanding of mechanisms driving device thrombosis and for preventing future events. We present a case of LVAD thrombosis with emphasis on recognition and treatment of acute pump thrombosis, and discuss a potentially novel strategy using percutaneous mechanical circulatory support for pump salvage.
Assuntos
Coração Auxiliar/efeitos adversos , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Terapia Trombolítica , Trombose/etiologia , Trombose/terapia , Adulto , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Falha de Prótese , Choque Cardiogênico/tratamento farmacológico , Trombose/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêuticoRESUMO
BACKGROUND: The Department of Veterans Affairs National Surgical Quality Improvement Program is a unique resource to prospectively analyze surgical outcomes from a cross-section of surgical services nationally. We used this database to assess risk factors for morbidity and mortality after esophagectomy in Veterans Affairs Medical Centers from 1991 to 2001. METHODS: A total of 1,777 patients underwent an esophagectomy at 109 Veterans Affairs hospitals with complete in-hospital and 30-day outcomes recorded. Bivariate and multivariable analyses were completed. RESULTS: Thirty-day mortality was 9.8% (174/1,777) and the incidence of one or more of 20 predefined complications was 49.5% (880/1,777). The most frequent postoperative complications were pneumonia in 21% (380/1,777), respiratory failure in 16% (288/1,777), and ventilator support more than 48 hours in 22% (387/1,777). Preoperative predictors of mortality based on multivariable analysis included neoadjuvant therapy, blood urea nitrogen level of more than 40 mg/dL, alkaline phosphatase level of more than 125 U/L, diabetes mellitus, alcohol abuse, decreased functional status, ascites, and increasing age. Preoperative factors impacting morbidity were increasing age, dyspnea, diabetes mellitus, chronic obstructive pulmonary disease, alkaline phosphatase level of more than 125 U/L, lower serum albumin concentration, increased complexity score, and decreased functional status. Intraoperative risk factors for mortality included the need for transfusion; intraoperative risk factors for morbidity included the need for transfusion and longer operative time. CONCLUSIONS: These data constitute the largest prospective outcomes cohort in the literature and document a near 50% morbidity rate and 10% mortality rate after esophagectomy. Data from this study can be used to better stratify patients before esophagectomy.