Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Nucl Med Commun ; 25(5): 527-32, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15100514

RESUMO

AIM: To analyse the role played by bone scintigraphy in the diagnosis of infected joint prostheses. METHODS: The study included 77 patients, aged 32-77 years, in whom infection of a joint prosthesis (48 hip, 29 knee) was suspected. In all patients the following examinations were performed consecutively: a two-phase Tc methylene diphosphonate (Tc-MDP) bone scan, a Tc hexamethylproplyene amine oxime (Tc-HMPAO) labelled white blood cell (WBC) scan, and a Tc microcolloid bone marrow (BM) scan. The minimum interval between examinations was 48 h. The diagnoses were based on data obtained from bacteriological cultures. RESULTS: The bone scan was positive in all patients and 28 of them had an infection (sensitivity 100%, specificity 0%). The WBC scan was positive in 61 patients but only 27 had an infection. The WBC scan was negative in 16 patients, and the possibility of infection was discarded in 15 of these cases (sensitivity 96%, specificity 30%). The results of the bone marrow scan were not compatible with those of the WBC scan (suggestive of infection) in 27 patients: 26 of them had prosthesis infection. The results of both examinations were compatible in the other 34 patients and the possibility of infection was discarded in 33 of these patients (sensitivity 92.8%, specificity 98%). The addition of a BM scan to a WBC scan decreased the sensitivity from 96% to 92.8% but increased specificity from 30% to 98%. The addition of a bone scan to this dual combination did not alter the results. CONCLUSIONS: When infection of a prosthesis is suspected the diagnostic procedure should start with a WBC scan followed, if positive, by a BM scan. This procedure reduces the cost, the time required for a diagnosis, and the dose of radiation received by the patient.


Assuntos
Prótese Articular/efeitos adversos , Leucócitos/diagnóstico por imagem , Osteíte/diagnóstico por imagem , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos de Tecnécio , Tecnécio Tc 99m Exametazima , Medronato de Tecnécio Tc 99m , Compostos de Estanho , Adulto , Idoso , Osso e Ossos/diagnóstico por imagem , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Osteíte/etiologia , Infecções Relacionadas à Prótese/etiologia , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA