Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Magn Reson Med ; 70(2): 466-78, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23042686

RESUMO

The main obstacle to high-resolution (<1.5 mm isotropic) 3D diffusion-weighted MRI is the differential motion-induced phase error from shot-to-shot. In this work, the phase error is addressed with a hybrid 3D navigator approach that corrects motion-induced phase in two ways. In the first, rigid-body motion is corrected for every shot. In the second, repeatable nonrigid-body pulsation is corrected for each portion of the cardiac cycle. These phase error corrections were implemented with a 3D diffusion-weighted steady- state free precession pulse sequence and were shown to mitigate signal dropouts caused by shot-to-shot phase inconsistencies compared to a standard gridding reconstruction in healthy volunteers. The proposed approach resulted in diffusion contrast more similar to the contrast observed in the reference echo-planer imaging scans than reconstruction of the same data without correction. Fractional anisotropy and Color fractional anisotropy maps generated with phase-corrected data were also shown to be more similar to echo-planer imaging reference scans than those generated without phase correction.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Adulto , Algoritmos , Anisotropia , Feminino , Humanos , Masculino , Movimento (Física) , Movimento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Magn Reson Med ; 68(2): 430-40, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22213138

RESUMO

In diffusion-weighted imaging, multishot acquisitions are problematic due to intershot inconsistencies of the phase caused by motion during the diffusion-encoding gradients. A model for the motion-induced phase errors in diffusion-weighted-MRI of the brain is presented, in which rigid-body and nonrigid-body motion are separated. In the model, it is assumed that nonrigid-body motion is due to cardiac pulsation, and that the motion patterns are repeatable from beat-to-beat. To test the validity of this assumption, the repeatability of nonrigid-body motion-induced phase errors is quantified in three healthy volunteers. Nonrigid-body motion-induced phase was found to significantly correlate (P < 0.05) with pulse-oximeter waveforms in ~83% of the pixels tested across all slices and subjects.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Técnicas de Imagem de Sincronização Cardíaca/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Biológicos , Adulto , Algoritmos , Encéfalo/fisiologia , Movimentos da Cabeça/fisiologia , Humanos , Masculino , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
AJNR Am J Neuroradiol ; 43(7): 944-950, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35649725

RESUMO

A recent coronavirus disease 2019-related shutdown of the main production facility of iohexol in China has led to massive shortages of iodinated contrast material across the globe. This shortage has also jeopardized neuroimaging. In this article, we describe remedies to reduce iodinated contrast material use for stroke imaging, which is its primary use in neuroimaging, that we have implemented in our hospital network.


Assuntos
COVID-19 , Meios de Contraste , Humanos , Inteligência , Iohexol , Neuroimagem
4.
Psychol Med ; 41(5): 959-69, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20663254

RESUMO

BACKGROUND: Patients with schizophrenia (SZ) characteristically exhibit supranormal levels of cortical activity to self-induced sensory stimuli, ostensibly because of abnormalities in the neural signals (corollary discharges, CDs) normatively involved in suppressing the sensory consequences of self-generated actions. The nature of these abnormalities is unknown. This study investigated whether SZ patients experience CDs that are abnormally delayed in their arrival at the sensory cortex. METHOD: Twenty-one patients with SZ and 25 matched control participants underwent electroencephalography (EEG). Participants' level of cortical suppression was calculated as the amplitude of the N1 component evoked by a button press-elicited auditory stimulus, subtracted from the N1 amplitude evoked by the same stimulus presented passively. In the three experimental conditions, the auditory stimulus was delivered 0, 50 or 100 ms subsequent to the button-press. Fifteen SZ patients and 17 healthy controls (HCs) also underwent diffusion tensor imaging (DTI), and the fractional anisotropy (FA) of participants' arcuate fasciculus was used to predict their level of cortical suppression in the three conditions. RESULTS: While the SZ patients exhibited subnormal N1 suppression to undelayed, self-generated auditory stimuli, these deficits were eliminated by imposing a 50-ms, but not a 100-ms, delay between the button-press and the evoked stimulus. Furthermore, the extent to which the 50-ms delay normalized a patient's level of N1 suppression was linearly related to the FA of their arcuate fasciculus. CONCLUSIONS: These data suggest that SZ patients experience temporally delayed CDs to self-generated auditory stimuli, putatively because of structural damage to the white-matter (WM) fasciculus connecting the sites of discharge initiation and destination.


Assuntos
Imagem de Tensor de Difusão , Eletroencefalografia , Retroalimentação Sensorial , Alucinações/fisiopatologia , Vias Neurais , Esquizofrenia/fisiopatologia , Adulto , Idoso , Córtex Auditivo/fisiopatologia , Estudos de Casos e Controles , Feminino , Lobo Frontal/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Neurológicos , Inibição Neural , Percepção da Fala
5.
AJNR Am J Neuroradiol ; 42(1): 65-72, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33431503

RESUMO

BACKGROUND AND PURPOSE: Detecting intracranial distal arterial occlusions on CTA is challenging but increasingly relevant to clinical decision-making. Our purpose was to determine whether the use of CTP-derived time-to-maximum of the tissue residue function maps improves diagnostic performance for detecting these occlusions. MATERIALS AND METHODS: Seventy consecutive patients with a distal arterial occlusion and 70 randomly selected controls who underwent multimodal CT with CTA and CTP for a suspected acute ischemic stroke were included in this retrospective study. Four readers with different levels of experience independently read the CTAs in 2 separate sessions, with and without time-to-maximum of the tissue residue function maps, recording the presence or absence of an occlusion, diagnostic confidence, and interpretation time. Accuracy for detecting distal occlusions was assessed using receiver operating characteristic analysis, and areas under curves were compared to assess whether accuracy improved with use of time-to-maximum of the tissue residue function. Changes in diagnostic confidence and interpretation time were assessed using the Wilcoxon signed rank test. RESULTS: Mean sensitivity for detecting occlusions on CTA increased from 70.7% to 90.4% with use of time-to-maximum of the tissue residue function maps. Diagnostic accuracy improved significantly for the 4 readers (P < .001), with areas under the receiver operating characteristic curves increasing by 0.186, 0.136, 0.114, and 0.121, respectively. Diagnostic confidence and speed also significantly increased. CONCLUSIONS: All assessed metrics of diagnostic performance for detecting distal arterial occlusions improved with the use of time-to-maximum of the tissue residue function maps, encouraging their use to aid in interpretation of CTA by both experienced and inexperienced readers. These findings show the added diagnostic value of including CTP in the acute stroke imaging protocol.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Assistida por Computador/métodos , AVC Isquêmico/diagnóstico por imagem , Idoso , Arteriopatias Oclusivas/complicações , Feminino , Humanos , AVC Isquêmico/etiologia , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
7.
AJNR Am J Neuroradiol ; 39(4): 669-677, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29545245

RESUMO

BACKGROUND AND PURPOSE: Intracranial dural arteriovenous fistulas carry a risk of substantial neurologic complications but can be difficult to detect on structural MR imaging and TOF-MRA. The purpose of this study was to assess the accuracy and added value of 3D pseudocontinuous arterial spin-labeling MR imaging for the detection of these lesions. MATERIALS AND METHODS: This retrospective study included 39 patients with a dural arteriovenous fistula and 117 controls who had undergone both DSA and MR imaging with pseudocontinuous arterial spin-labeling. Two neuroradiologists blinded to the DSA results independently assessed MR imaging with and without pseudocontinuous arterial spin-labeling. They recorded specific signs, including venous arterial spin-labeling signal, and the likelihood of a dural arteriovenous fistula using a 5-point Likert scale. Logistic regression and receiver operating characteristic analyses were performed to determine the accuracy of specific signs and the added value of pseudocontinuous arterial spin-labeling. Interobserver agreement was determined by using κ statistics. RESULTS: Identification of the venous arterial spin-labeling signal had a high sensitivity (94%) and specificity (88%) for the presence a dural arteriovenous fistula. Receiver operating characteristic analysis showed significant improvement in diagnostic performance with the addition of pseudocontinuous arterial spin-labeling in comparison with structural MR imaging (Δarea under the receiver operating characteristic curve = 0.179) and a trend toward significant improvement in comparison with structural MR imaging with time-of-flight MRA (Δarea under the receiver operating characteristic curve = 0.043). Interobserver agreement for the presence of a dural arteriovenous fistula improved substantially and was almost perfect with the addition of pseudocontinuous arterial spin-labeling (κ = 0.92). CONCLUSIONS: Venous arterial spin-labeling signal has high sensitivity and specificity for the presence of a dural arteriovenous fistula, and the addition of pseudocontinuous arterial spin-labeling increases confidence in the diagnosis of this entity on MR imaging.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Marcadores de Spin
8.
AJNR Am J Neuroradiol ; 28(3): 411-20, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17353305

RESUMO

SUMMARY: Diffusion tensor (DT) MR imaging has frequently been applied in multiple sclerosis (MS) because of its ability to detect and quantify disease-related changes of the tissue microstructure within and outside T2-visible lesions. DT MR imaging data collection places high demands on scanner hardware and, though the acquisition and postprocessing can be relatively straightforward, numerous challenges remain in improving the reproducibility of this technique. Although there are some issues concerning image quality, echo-planar imaging is the most widely used acquisition scheme for diffusion imaging studies. Once the DT is estimated, indexes conveying the size, shape, and orientation of the DT can be calculated and further analyzed by using either histogram- or region-of-interest-based analyses. Because the orientation of the DT reflects the orientation of the axonal fibers of the brain, the pathways of the major white matter tracts can also be visualized. The DT model of diffusion, however, is not sufficient to characterize the diffusion properties of the brain when complex populations of fibers are present in a single voxel, and new ways to address this issue have been proposed. Two developments have enabled considerable improvements in the application of DT MR imaging: high magnetic field strengths and multicoil receiver arrays with parallel imaging. This review critically discusses models, acquisition, and postprocessing approaches that are currently available for DT MR imaging, as well as their limitations and possible improvements, to provide a better understanding of the strengths and weaknesses of this technique and a background for designing diffusion studies in MS.


Assuntos
Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Humanos
10.
AJNR Am J Neuroradiol ; 37(8): 1399-404, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26965466

RESUMO

BACKGROUND AND PURPOSE: Endovascular trials suggest that revascularization benefits a subset of acute ischemic stroke patients with large-artery occlusion and small-core infarct volumes. The objective of our study was to identify thresholds of noncontrast CT-ASPECTS and collateral scores on CT angiography that best predict ischemic core volume thresholds quantified by CT perfusion among patients with acute ischemic stroke. MATERIALS AND METHODS: Fifty-four patients with acute ischemic stroke (<12 hours) and MCA/intracranial ICA occlusion underwent NCCT/CTP during their initial evaluation. CTP analysis was performed on a user-independent platform (RApid processing of PerfusIon and Diffusion), computing core infarct (defined as CBF of <30% normal). A target mismatch profile consisting of infarction core of ≤50 mL was selected to define candidates with acute ischemic stroke likely to benefit from revascularization. RESULTS: NCCT-ASPECTS of ≥9 with a CTA collateral score of 3 had 100% specificity for identifying patients with a CBF core volume of ≤50 mL. NCCT-ASPECTS of ≤6 had 100% specificity for identifying patients with a CBF core volume of >50 mL. In our cohort, 44 (81%) patients had an NCCT-ASPECTS of ≥9, a CTA collateral score of 3, or an NCCT-ASPECTS of ≤6. CONCLUSIONS: Using an NCCT-ASPECTS of ≥9 or a CTA collateral score of 3 best predicts CBF core volume infarct of ≤50 mL, while an NCCT-ASPECTS of ≤6 best predicts a CBF core volume infarct of >50 mL. Together these thresholds suggest that a specific population of patients with acute ischemic stroke not meeting such profiles may benefit most from CTP imaging to determine candidacy for revascularization.


Assuntos
Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Interpretação de Imagem Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Humanos , Imagem de Perfusão , Sensibilidade e Especificidade
11.
AJNR Am J Neuroradiol ; 36(8): 1419-25, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25999410

RESUMO

BACKGROUND AND PURPOSE: Treatment strategies in acute ischemic stroke aim to curtail ischemic progression. Emerging paradigms propose patient subselection using imaging biomarkers derived from CT, CTA, and CT perfusion. We evaluated the performance of a fully-automated computational tool, hypothesizing enhancements compared with qualitative approaches. The correlation between imaging variables and clinical outcomes in a cohort of patients with acute ischemic stroke is reported. MATERIALS AND METHODS: Sixty-two patients with acute ischemic stroke and MCA or ICA occlusion undergoing multidetector CT, CTA, and CTP were retrospectively evaluated. CTP was processed on a fully operator-independent platform (RApid processing of PerfusIon and Diffusion [RAPID]) computing automated core estimates based on relative cerebral blood flow and relative cerebral blood volume and hypoperfused tissue volumes at varying thresholds of time-to-maximum. Qualitative analysis was assigned by 2 independent reviewers for each variable, including CT-ASPECTS, CBV-ASPECTS, CBF-ASPECTS, CTA collateral score, and CTA clot burden score. Performance as predictors of favorable clinical outcome and final infarct volume was established for each variable. RESULTS: Both RAPID core estimates, CT-ASPECTS, CBV-ASPECTS, and clot burden score correlated with favorable clinical outcome (P < .05); CBF-ASPECTS and collateral score were not significantly associated with favorable outcome, while hypoperfusion estimates were variably associated, depending on the selected time-to-maximum thresholds. Receiver operating characteristic analysis demonstrated disparities among tested variables, with RAPID core and hypoperfusion estimates outperforming all qualitative approaches (area under the curve, relative CBV = 0.86, relative CBF = 0.81; P < .001). CONCLUSIONS: Qualitative approaches to acute ischemic stroke imaging are subject to limitations due to their subjective nature and lack of physiologic information. These findings support the benefits of high-speed automated analysis, outperforming conventional methodologies while limiting delays in clinical management.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagem de Perfusão , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
12.
AJNR Am J Neuroradiol ; 21(9): 1596-602, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11039337

RESUMO

BACKGROUND AND PURPOSE: The importance of diffusion-weighted imaging (DWI) for delineating acute ischemic lesions has been investigated extensively; however, few studies have investigated the role of DWI in the subacute stage of stroke. Because these lesions tend to appear bright throughout the first days of ischemia, owing to restricted diffusion, we speculated that DWI could also improve the detection of subacute infarcts as compared with conventional and contrast-enhanced MR imaging. METHODS: Interleaved echo-planar DWI with phase navigation was performed on a 1.5-T MR unit in a consecutive series of 53 patients (mean age, 66 +/- 14 years) with suspected recent cerebral ischemia. The interval between onset of clinical symptoms and MR imaging ranged from 1 to 14 days (mean, 6 +/- 4 days). Contrast material was given to 28 patients in a dose of 0.1 mmol/kg. RESULTS: DWI clearly delineated recent ischemic damage in 39 patients (74%) as compared with 33 (62%) in whom lesions were identified or suspected on conventional T2-weighted images. DWI provided information not accessible with T2-weighted imaging in 17 patients when evidence of lesion multiplicity or detection of clinically unrelated recent lesions was included for comparison. Subacute ischemic lesions were also seen more frequently on DWI sequences than on contrast-enhanced images (20 versus 13 patients). DWI was more likely to make a diagnostic contribution in the first week of stroke and in patients with small lesions or preexisting ischemic cerebral damage than was conventional MR imaging. CONCLUSION: Recent ischemic damage is better shown on DWI sequences than on conventional and contrast-enhanced MR images throughout the first days after stroke and may provide further information about the origin of clinical symptoms. Adding DWI to imaging protocols for patients with subacute cerebral ischemia is recommended.


Assuntos
Isquemia Encefálica/diagnóstico , Encéfalo/patologia , Meios de Contraste , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Infarto Cerebral/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
AJNR Am J Neuroradiol ; 21(3): 587-91, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10730657

RESUMO

Diffusion-weighted MR imaging may increase the sensitivity and specificity of MR imaging for certain pathologic conditions of the spinal cord but is rarely performed because of several technical issues. We therefore tested a novel phase-navigated spin-echo diffusion-weighted interleaved echo-planar imaging sequence in seven healthy volunteers and six patients with intramedullary lesions. We performed diffusion-weighted MR imaging of the spinal cord with high spatial resolution. Different patterns of diffusion abnormalities observed in patient studies support the possible diagnostic impact of diffusion-weighted MR imaging for diseases of the spinal cord.


Assuntos
Imageamento por Ressonância Magnética/métodos , Medula Espinal/patologia , Adulto , Imagem Ecoplanar , Feminino , Humanos , Masculino , Medula Espinal/anatomia & histologia , Doenças da Medula Espinal/diagnóstico
14.
J Neural Transm Suppl ; 59: 45-52, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10961417

RESUMO

Introduction of magnetic resonance imaging (MRI) has opened new possibilities for detecting age-related brain tissue changes. The majority of these abnormalities consists of hyperintense foci in the deep and subcortical white matter probably related to microvascular disturbances and of signal hyperintensities around the lateral ventricles. It has also been suggested that these abnormalities may contribute to the development of cognitive impairment. The correlation between age-related signal abnormalities on conventional MRI and neuropsychologic dysfunction is limited, however, and a threshold beyond which such a relation may come into existence has not yet been defined. Poor tissue characterisation by conventional MRI may be one explanation. Therefore, new pulse sequences are expected not only to provide a higher lesion contrast such as the fluid attenuated inversion recovery (FLAIR) technique but also to offer new insights concerning the composition of incidental brain lesions. In this context both magnetisation transfer imaging (MTI) and diffusion weighted imaging (DWI) may serve to gain information about the integrity of cell membranes and organelles and the preservation of axons and fibre tracts. We will review the technical background of these recently developed MR sequences and their first applications to age-associated brain abnormalities.


Assuntos
Envelhecimento/fisiologia , Encéfalo/patologia , Demência Vascular/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/tendências , Humanos
15.
Magn Reson Imaging ; 22(5): 619-24, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15172054

RESUMO

In a canine model the signal dynamics of a new oligomer-based MR contrast agent (NMS60, 2158 Da) were compared to Gd-DTPA to investigate the agents' potential for magnetic resonance angiography (MRA). Twelve male mongrel dogs were imaged sequentially under anesthesia with two different MRA sequences (Tlw 3DSPGR). Initial enhancement was measured every 9 s for eight points in time. Thereafter, spatial highly resolved MRAs were obtained at 5, 10, 15, 20, 30, 45, and 60 min post-injection of two different dosages. Over the first 20 s following bolus administration the average arterial enhancement of 0.1 mmol(Gd)kg NMS60 was 44% greater than Gd-DTPA. Twenty minutes post-injection the relative signal intensity of NMS60 was as high as the peak signal intensity with Gd-DTPA at the same dosage level (0.1 mmol(Gd)/kg). In the animals that received NMS60 injections the vascular conspicuity was overly superior to those who received Gd-DTPA. No significant toxicity effects were noted for either dosage level. The intermediate weight contrast agent NMS60 offers greater vascular enhancement and retention time than Gd-DTPA. For a given set of optimized imaging parameters this offers improved spatial details, less arterial/venous overlap, and better vascular contrast.


Assuntos
Meios de Contraste , Gadolínio DTPA , Compostos Organometálicos , Animais , Meios de Contraste/química , Meios de Contraste/toxicidade , Cães , Gadolínio DTPA/química , Gadolínio DTPA/toxicidade , Dose Letal Mediana , Angiografia por Ressonância Magnética , Masculino , Compostos Organometálicos/química , Compostos Organometálicos/toxicidade , Ratos
16.
Biomed Tech (Berl) ; 46(1-2): 24-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11258138

RESUMO

We investigated the EEG beta event-related synchronization (ERS) after tactile finger stimulation in three subjects. Prior studies from our group using electrical stimulation and self-paced movement showed a beta rebound within one second after stimulation respectively movement offset. As the tactile-stimulation-data showed a similar ERS behaviour, we extracted the cortical sources for this beta rebound by the linear estimation method in order to see whether the representation areas of different fingers were distinguishable (as is possible with MEG data). Although realistic head models of two subjects were used for the calculations the fingers could not be spatially distinguished. However, regarding the whole spatio-temporal pattern of the ERS for different fingers clear differences can be observed.


Assuntos
Ritmo beta , Mapeamento Encefálico , Sincronização Cortical , Dedos/inervação , Córtex Motor/fisiologia , Córtex Somatossensorial/fisiologia , Tato/fisiologia , Adulto , Vias Aferentes/fisiologia , Eletroencefalografia , Humanos , Imageamento Tridimensional , Masculino , Valores de Referência , Processamento de Sinais Assistido por Computador
17.
AJNR Am J Neuroradiol ; 35(7): 1293-302, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24763417

RESUMO

BACKGROUND AND PURPOSE: Parallel imaging facilitates the acquisition of echo-planar images with a reduced TE, enabling the incorporation of an additional image at a later TE. Here we investigated the use of a parallel imaging-enhanced dual-echo EPI sequence to improve lesion conspicuity in diffusion-weighted imaging. MATERIALS AND METHODS: Parallel imaging-enhanced dual-echo DWI data were acquired in 50 consecutive patients suspected of stroke at 1.5T. The dual-echo acquisition included 2 EPI for 1 diffusion-preparation period (echo 1 [TE = 48 ms] and echo 2 [TE = 105 ms]). Three neuroradiologists independently reviewed the 2 echoes by using the routine DWI of our institution as a reference. Images were graded on lesion conspicuity, diagnostic confidence, and image quality. The apparent diffusion coefficient map from echo 1 was used to validate the presence of acute infarction. Relaxivity maps calculated from the 2 echoes were evaluated for potential complementary information. RESULTS: Echo 1 and 2 DWIs were rated as better than the reference DWI. While echo 1 had better image quality overall, echo 2 was unanimously favored over both echo 1 and the reference DWI for its high sensitivity in detecting acute infarcts. CONCLUSIONS: Parallel imaging-enhanced dual-echo diffusion-weighted EPI is a useful method for evaluating lesions with reduced diffusivity. The long TE of echo 2 produced DWIs that exhibited superior lesion conspicuity compared with images acquired at a shorter TE. Echo 1 provided higher SNR ADC maps for specificity to acute infarction. The relaxivity maps may serve to complement information regarding blood products and mineralization.


Assuntos
Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Multimodal/métodos , Acidente Vascular Cerebral/patologia , Doença Aguda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
AJNR Am J Neuroradiol ; 34(11): 2092-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23744690

RESUMO

BACKGROUND AND PURPOSE: 2D gradient-echo imaging is sensitive to T2* lesions (hemorrhages, mineralization, and vascular lesions), and susceptibility-weighted imaging is even more sensitive, but at the cost of additional scan time (SWI: 5-10 minutes; 2D gradient-echo: 2 minutes). The long acquisition time of SWI may pose challenges in motion-prone patients. We hypothesized that 2D SWI/phase unwrapped images processed from 2D gradient-echo imaging could improve T2* lesion detection. MATERIALS AND METHODS: 2D gradient-echo brain images of 50 consecutive pediatric patients (mean age, 8 years) acquired at 3T were retrospectively processed to generate 2D SWI/phase unwrapped images. The 2D gradient-echo and 2D SWI/phase unwrapped images were compared for various imaging parameters and were scored in a blinded fashion. RESULTS: Of 50 patients, 2D gradient-echo imaging detected T2* lesions in 29 patients and had normal findings in 21 patients. 2D SWI was more sensitive than standard 2D gradient-echo imaging in detecting T2* lesions (P < .0001). 2D SWI/phase unwrapped imaging also improved delineation of normal venous structures and nonpathologic calcifications and helped distinguish calcifications from hemorrhage. A few pitfalls of 2D SWI/phase unwrapped imaging were noted, including worsened motion and dental artifacts and challenges in detecting T2* lesions adjacent to calvaria or robust deoxygenated veins. CONCLUSIONS: 2D SWI and associated phase unwrapped images processed from standard 2D gradient-echo images were more sensitive in detecting T2* lesions and delineating normal venous structures and nonpathologic mineralization, and they also helped distinguish calcification at no additional scan time. SWI processing of 2D gradient-echo images may be a useful adjunct in cases in which longer scan times of 3D SWI are difficult to implement.


Assuntos
Algoritmos , Encefalopatias/patologia , Encéfalo/patologia , Imagem Ecoplanar/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
AJNR Am J Neuroradiol ; 33(7): 1337-42, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22403781

RESUMO

BACKGROUND AND PURPOSE: PI improves routine EPI-based DWI by enabling higher spatial resolution and reducing geometric distortion, though it remains unclear which of these is most important. We evaluated the relative contribution of these factors and assessed their ability to increase lesion conspicuity and diagnostic confidence by using a GRAPPA technique. MATERIALS AND METHODS: Four separate DWI scans were obtained at 1.5T in 48 patients with independent variation of in-plane spatial resolution (1.88 mm(2) versus 1.25 mm(2)) and/or reduction factor (R = 1 versus R = 3). A neuroradiologist with access to clinical history and additional imaging sequences provided a reference standard diagnosis for each case. Three blinded neuroradiologists assessed scans for abnormalities and also evaluated multiple imaging-quality metrics by using a 5-point ordinal scale. Logistic regression was used to determine the impact of each factor on subjective image quality and confidence. RESULTS: Reference standard diagnoses in the patient cohort were acute ischemic stroke (n = 30), ischemic stroke with hemorrhagic conversion (n = 4), intraparenchymal hemorrhage (n = 9), or no acute lesion (n = 5). While readers preferred both a higher reduction factor and a higher spatial resolution, the largest effect was due to an increased reduction factor (odds ratio, 47 ± 16). Small lesions were more confidently discriminated from artifacts on R = 3 images. The diagnosis changed in 5 of 48 scans, always toward the reference standard reading and exclusively for posterior fossa lesions. CONCLUSIONS: PI improves DWI primarily by reducing geometric distortion rather than by increasing spatial resolution. This outcome leads to a more accurate and confident diagnosis of small lesions.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Aumento da Imagem/normas , Interpretação de Imagem Assistida por Computador/normas , Acidente Vascular Cerebral/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Calibragem , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
20.
AJNR Am J Neuroradiol ; 32(7): 1274-9, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21596809

RESUMO

BACKGROUND AND PURPOSE: RS-EPI has been suggested as an alternative approach to EPI for high-resolution DWI with reduced distortions. To determine whether RS-EPI is a useful approach for routine clinical use, we implemented GRAPPA-accelerated RS-EPI DWI at our pediatric hospital and graded the images alongside standard accelerated (ASSET) EPI DWI used routinely for clinical studies. MATERIALS AND METHODS: GRAPPA-accelerated RS-EPI DWIs and ASSET EPI DWIs were acquired on 35 pediatric patients using a 3T system in 35 pediatric patients. The images were graded alongside each other by using a 7-point Likert scale as follows: 1, nondiagnostic; 2, poor; 3, acceptable; 4, standard; 5, above average; 6, good; and 7, outstanding. RESULTS: The following were the average scores for EPI and RS-EPI, respectively: resolution, 3.5/5.2; distortion level, 2.9/6.0; SNR, 3.4/4.1; lesion conspicuity, 3.3/5.9; and diagnostic confidence, 3.2/6.0. Overall, the RS-EPI had significantly improved diagnostic confidence and more reliably defined the extent and structure of several lesions. Although ASSET EPI scans had better SNR per scanning time, the higher spatial resolution as well as reduced blurring and distortions on RS-EPI scans helped to better reveal important anatomic details at the cortical-subcortical levels, brain stem, temporal and inferior frontal lobes, skull base, sinonasal cavity, cranial nerves, and orbits. CONCLUSIONS: This work shows the importance of both resolution and decreased distortions in the clinics, which can be accomplished by a combination of parallel imaging and alternative k-space trajectories such as RS-EPI.


Assuntos
Encefalopatias/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/normas , Imagem Ecoplanar/métodos , Imagem Ecoplanar/normas , Adolescente , Artefatos , Astrocitoma/diagnóstico , Neoplasias Encefálicas/diagnóstico , Criança , Pré-Escolar , Empiema Subdural/diagnóstico , Encefalomalacia/diagnóstico , Feminino , Humanos , Lactente , Recém-Nascido , Doença de Leigh/diagnóstico , Masculino , Doença de Moyamoya/diagnóstico , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA