1.
Phys Rev Lett ; 111(8): 082502, 2013 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-24010431

RESUMO

The plasma astrophysical S factor for the 3He(d,p)4He fusion reaction was measured for the first time at temperatures of few keV, using the interaction of intense ultrafast laser pulses with molecular deuterium clusters mixed with 3He atoms. Different proportions of D2 and 3He or CD4 and 3He were mixed in the gas target in order to allow the measurement of the cross section for the 3He(d,p)4He reaction. The yield of 14.7 MeV protons from the 3He(d,p)4He reaction was measured in order to extract the astrophysical S factor at low energies. Our result is in agreement with other S factor parametrizations found in the literature.

2.
Phys Rev Lett ; 111(5): 055002, 2013 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-23952411

RESUMO

Two different methods have been employed to determine the plasma temperature in a laser-cluster fusion experiment on the Texas Petawatt laser. In the first, the temperature was derived from time-of-flight data of deuterium ions ejected from exploding D(2) or CD(4) clusters. In the second, the temperature was measured from the ratio of the rates of two different nuclear fusion reactions occurring in the plasma at the same time: D(d,(3)He)n and (3)He(d,p)(4)He. The temperatures determined by these two methods agree well, which indicates that (i) the ion energy distribution is not significantly distorted when ions travel in the disassembling plasma; (ii) the kinetic energy of deuterium ions, especially the "hottest part" responsible for nuclear fusion, is well described by a near-Maxwellian distribution.

3.
Sci Rep ; 12(1): 15173, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36071154

RESUMO

Recent studies have shown that energetic laser-driven ions with some energy spread can heat small solid-density samples uniformly. The balance among the energy losses of the ions with different kinetic energies results in uniform heating. Although heating with an energetic laser-driven ion beam is completed within a nanosecond and is often considered sufficiently fast, it is not instantaneous. Here we present a theoretical study of the temporal evolution of the temperature of solid-density gold and diamond samples heated by a quasimonoenergetic aluminum ion beam. We calculate the temporal evolution of the predicted temperatures of the samples using the available stopping power data and the SESAME equation-of-state tables. We find that the temperature distribution is initially very uniform, which becomes less uniform during the heating process. Then, the temperature uniformity gradually improves, and a good temperature uniformity is obtained toward the end of the heating process.

4.
PLoS One ; 16(12): e0261574, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34919591

RESUMO

We present a time-resolved analysis of Rayleigh scattering measurements to determine the average size of methane clusters and find the optimum timing for laser-cluster fusion experiments. We measure Rayleigh scattering and determine the average size of methane clusters varying the backing pressure (P0) from 11 bar to 69 bar. Regarding the onset of clustering, we estimate that the average size of methane clusters at the onset of clustering is Nc0≅20 at 11 bar. According to our measurements, the average cluster radius r follows the power law of r∝P01.86. Our ion time-of-flight measurements indicate that we have produced energetic deuterium ions with kT = 52±2 keV after laser-cluster interaction using CD4 gas at 50 bar. We find that this ion temperature agrees with the predicted temperature from CD4 clusters at 50 bar with r = 14 nm assuming the Coulomb explosion model.


Assuntos
Deutério/química , Difusão Dinâmica da Luz/métodos , Metano/análise , Metano/química , Deutério/análise , Lasers , Temperatura
5.
J Food Prot ; 72(3): 637-43, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19343956

RESUMO

Souse is a fully cooked, ready-to-eat gelled pork product. There is a zero-tolerance policy for Listeria monocytogenes in ready-to-eat meat products. The survival and/or growth of L. monocytogenes in souse is unknown. The effectiveness of three different souse formulations (pH 4.3, 4.7, and 5.1) for controlling the growth of L. monocytogenes at two refrigerated storage temperatures (5 and 10 degrees C) was evaluated. All products were vacuum packaged. Uninoculated product was prepared as the control, and other products were artificially surface contaminated with a three-strain cocktail of L. monocytogenes (10(6) CFU/ cm2). Microbial counts were obtained on selective and nonselective media twice weekly through 8 weeks of storage. Souse did not support the growth of L. monocytogenes regardless of product formulation or storage temperature. At 5 degrees C, D-values for products with pH values of 4.7 and 5.1 were not different, but survival of L. monocytogenes in product with a lower pH (4.3) was decreased compared with survival in products with higher pH values (P < 0.05). Survival of L. monocytogenes was not impacted by storage temperatures (P > 0.05). Consumer acceptability (n = 75 souse consumers) of pH 4.3 products was not different from that for (typical) pH 4.7 products (P > 0.05). These results indicate that conventionally produced souse does not support the growth of L. monocytogenes and that inactivation of the organism is more likely in products formulated at a lower pH (< or = 4.3) without affecting consumer acceptance.


Assuntos
Embalagem de Alimentos/métodos , Conservação de Alimentos/métodos , Listeria monocytogenes/crescimento & desenvolvimento , Produtos da Carne/microbiologia , Animais , Contagem de Colônia Microbiana , Qualidade de Produtos para o Consumidor , Contaminação de Alimentos/análise , Contaminação de Alimentos/prevenção & controle , Microbiologia de Alimentos , Humanos , Concentração de Íons de Hidrogênio , Suínos , Temperatura , Fatores de Tempo , Vácuo
6.
J Food Prot ; 71(1): 191-5, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18236683

RESUMO

Staphylococcus aureus contamination and enterotoxin production is a potential food safety hazard during the drying step of production of air-dried fresh country sausage. The growth characteristics and enterotoxin production of S. aureus during the drying step of this product with and without added sodium nitrite were evaluated. Three strains of S. aureus were grown to stationary phase and inoculated (10(4) CFU/g) into sausage ingredients. Fresh pork sausages were stuffed into natural casings and allowed to dry for 10 days at 21 degrees C with 60% relative humidity (RH). In control sausage (1.76% [wt/wt] salt) with no S. aureus, aerobic plate counts increased by 5.5 log/g during the 10-day drying period, and coliforms increased by 4.8 log/g. The addition of sodium nitrite (154 ppm of nitrite, 2.24% [wt/wt] salt) or increased salt (3.64%, wt/wt) to sausage limited the growth of coliform bacteria (P < 0.05). S. aureus numbers increased approximately 2 log units during the drying step, regardless of additional salt or nitrite. Additional salt or nitrite had no effect on S. aureus growth (P > 0.05). Staphylococcal enterotoxin (SE) was not detected in air-dried fresh sausages at any time. Our results suggest that drying of fresh pork sausage under similar parameters listed in this study does not support SE production.


Assuntos
Enterotoxinas/biossíntese , Contaminação de Alimentos/análise , Manipulação de Alimentos/métodos , Produtos da Carne/microbiologia , Staphylococcus aureus , Animais , Contagem de Colônia Microbiana , Qualidade de Produtos para o Consumidor , Enterotoxinas/análise , Humanos , Sais/farmacologia , Nitrito de Sódio/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento , Staphylococcus aureus/metabolismo , Suínos , Temperatura , Fatores de Tempo
7.
Sci Rep ; 6: 29441, 2016 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-27405664

RESUMO

Recent progress in laser-driven quasi-monoenergetic ion beams enabled the production of uniformly heated warm dense matter. Matter heated rapidly with this technique is under extreme temperatures and pressures, and promptly expands outward. While the expansion speed of an ideal plasma is known to have a square-root dependence on temperature, computer simulations presented here show a linear dependence of expansion speed on initial plasma temperature in the warm dense matter regime. The expansion of uniformly heated 1-100 eV solid density gold foils was modeled with the RAGE radiation-hydrodynamics code, and the average surface expansion speed was found to increase linearly with temperature. The origin of this linear dependence is explained by comparing predictions from the SESAME equation-of-state tables with those from the ideal gas equation-of-state. These simulations offer useful insight into the expansion of warm dense matter and motivate the application of optical shadowgraphy for temperature measurement.

8.
J Dairy Sci ; 88(12): 4172-82, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16291608

RESUMO

Shelf-stable milk could benefit from sensory quality improvement. Current methods of heating cause flavor and nutrient degradation through exposure to overheated thermal exchange surfaces. Rapid heating with microwaves followed by sudden cooling could reduce or eliminate this problem. The objectives for this study were focused on designing and implementing continuous microwave thermal processing of skim fluid milks (white and chocolate) to compare sensory, microbiological, and biochemical parameters with conventionally prepared, indirect UHT milks. All test products were aseptically packaged and stored at ambient temperature for 12 mo. Every 3 mo, samples were taken for microbiological testing, reactive sulfhydryl determinations, active enzyme analysis, instrumental viscosity readings, color measurements, and descriptive sensory evaluation. Microbiological plate counts were negative on all milks at each time point. Enzymatic assays showed that plasmin was inactivated by both heat treatments. 5,5'-dithio-bis(2-nitrobenzoic acid) analysis, a measure of reactive sulfhydryl (-SH-) groups, showed that the initial thiol content was not significantly different between the microwave-processed and UHT-treated milks. However, both heating methods resulted in an increased thiol level compared with conventionally pasteurized milk samples due to the higher temperatures attained. Sulfhydryl oxidase, a milk enzyme that catalyzes disulfide bond formation using a variety of protein substrates, retained activity following microwave processing, and decreased during storage. Viscosity values were essentially equivalent in microwave- and UHT-heated white skim milks. Sensory analyses established that UHT-treated milks were visibly darker, and exhibited higher caramelized and stale/fatty flavors with increased astringency compared with the microwave samples. Sweet aromatic flavor and sweet taste decreased during storage in both UHT and microwave milk products, whereas stale/fatty flavors increased over time. Sensory effects were more apparent in white milks than in chocolate varieties. These studies suggest that microwave technology may provide a useful alternative processing method for delivery of aseptic milk products that retain a long shelf life.


Assuntos
Manipulação de Alimentos/métodos , Temperatura Alta , Micro-Ondas , Leite/química , Leite/microbiologia , Sensação , Animais , Cor , Ácido Ditionitrobenzoico/análise , Gorduras/análise , Conservação de Alimentos , Oxirredutases/metabolismo , Compostos de Sulfidrila/análise , Paladar , Fatores de Tempo , Viscosidade
9.
Artigo em Inglês | MEDLINE | ID: mdl-26274289

RESUMO

Energetic deuterium ions from large deuterium clusters (>10nm diameter) irradiated by an intense laser pulse (>10(16)W/cm(2)) produce DD fusion neutrons for a time interval determined by the geometry of the resulting fusion plasma. We present an analytical solution of this time interval, the plasma disassembly time, for deuterium plasmas that are cylindrical in shape. Assuming a symmetrically expanding deuterium plasma, we calculate the expected fusion neutron yield and compare with an independent calculation of the yield using the concept of a finite confinement time at a fixed plasma density. The calculated neutron yields agree quantitatively with the available experimental data. Our one-dimensional simulations indicate that one could expect a tenfold increase in total neutron yield by magnetically confining a 10-keV deuterium fusion plasma for 10ns.

10.
Artigo em Inglês | MEDLINE | ID: mdl-26764832

RESUMO

In a recent experiment at the Trident laser facility, a laser-driven beam of quasimonoenergetic aluminum ions was used to heat solid gold and diamond foils isochorically to 5.5 and 1.7 eV, respectively. Here theoretical calculations are presented that suggest the gold and diamond were heated uniformly by these laser-driven ion beams. According to calculations and SESAME equation-of-state tables, laser-driven aluminum ion beams achievable at Trident, with a finite energy spread of ΔE/E∼20%, are expected to heat the targets more uniformly than a beam of 140-MeV aluminum ions with zero energy spread. The robustness of the expected heating uniformity relative to the changes in the incident ion energy spectra is evaluated, and expected plasma temperatures of various target materials achievable with the current experimental platform are presented.

11.
Sci Rep ; 5: 14318, 2015 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-26392208

RESUMO

With the development of several novel heating sources, scientists can now heat a small sample isochorically above 10,000 K. Although matter at such an extreme state, known as warm dense matter, is commonly found in astrophysics (e.g., in planetary cores) as well as in high energy density physics experiments, its properties are not well understood and are difficult to predict theoretically. This is because the approximations made to describe condensed matter or high-temperature plasmas are invalid in this intermediate regime. A sufficiently large warm dense matter sample that is uniformly heated would be ideal for these studies, but has been unavailable to date. Here we have used a beam of quasi-monoenergetic aluminum ions to heat gold and diamond foils uniformly and isochorically. For the first time, we visualized directly the expanding warm dense gold and diamond with an optical streak camera. Furthermore, we present a new technique to determine the initial temperature of these heated samples from the measured expansion speeds of gold and diamond into vacuum. We anticipate the uniformly heated solid density target will allow for direct quantitative measurements of equation-of-state, conductivity, opacity, and stopping power of warm dense matter, benefiting plasma physics, astrophysics, and nuclear physics.

12.
J Food Prot ; 65(6): 975-80, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12092731

RESUMO

The effects of cold storage and starvation on the subsequent heat resistance and freeze-thaw resistance of Vibrio vulnificus were studied. Three strains of V. vulnificus were evaluated. Cold stress had no effect on freeze-thaw resistance (P > 0.05). Starvation enhanced freeze-thaw resistance for one strain compared to controls (P < 0.05). V. vulnificus was not heat resistant; control populations were inactivated within 12 min at 47 degrees C. Starvation increased heat tolerance for one strain, but differences were small from a processing perspective (P < 0.05). Cold stress had no effect on heat resistance (P > 0.05). Cold adaptation (holding 4 h at 15 degrees C) enhanced cold temperature (5 degrees C) tolerance. This information will be helpful in the development of methods to minimize V. vulnificus risk.


Assuntos
Manipulação de Alimentos/métodos , Vibrio/fisiologia , Adaptação Fisiológica , Contagem de Colônia Microbiana , Microbiologia de Alimentos , Congelamento , Temperatura Alta , Fatores de Tempo , Vibrio/crescimento & desenvolvimento
13.
J Food Prot ; 67(1): 19-26, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14717346

RESUMO

The effect of extended cold or cold-acid storage of Escherichia coli O157:H7 on subsequent acid tolerance, freeze-thaw survival, heat tolerance, and virulence factor (Shiga toxin, intimin, and hemolysin) expression was determined. Three E. coli O157:H7 strains were stressed at 4 degrees C in TSB or pH 5.5 TSB for 4 weeks. The acid (TSB [pH 2.0] or simulated gastric fluid [pH 1.5]) tolerance, freeze-thaw (-20 degrees C to 21 degrees C) survival, and heat (56 degrees C) tolerance of stressed cells were compared with those of control cells. The beta-galactosidase activities of stressed and control cells containing a lacZ gene fusion in the stx2, eaeA, or hlyA gene were determined following stress in TSB or pH 5.5 TSB at 37 degrees C and in the exponential and stationary phases. Cold and cold-acid stresses decreased acid tolerance (P < 0.05), with a larger decrease in acid tolerance being observed after cold stress than after cold-acid stress (P < 0.05). Cold stress increased freeze-thaw survival for all three strains (P < 0.05). Prior cold or cold-acid stress had no effect on virulence factor production (P > 0.05), although growth in acidic media (pH 5.5) enhanced eaeA and hlyA expression (P < 0.05). These results indicate that the prolonged storage of E. coli O157:H7 at 4 degrees C has substantial effects on freeze-thaw tolerance but does not affect subsequent virulence gene expression.


Assuntos
Adaptação Fisiológica , Escherichia coli O157/fisiologia , Regulação Bacteriana da Expressão Gênica , Sequência de Bases , Contagem de Colônia Microbiana , Escherichia coli O157/genética , Escherichia coli O157/patogenicidade , Manipulação de Alimentos/métodos , Microbiologia de Alimentos , Congelamento , Concentração de Íons de Hidrogênio , Mapeamento por Restrição , Fatores de Tempo , Virulência/genética
14.
Arch Pharm Res ; 22(2): 202-7, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10230513

RESUMO

New series of catechol ether type derivatives 5, 6 have been synthesized and applied to biological tests. Even though it is a preliminary data, some of our target molecules show the promising result against PDE IV inhibition. SAR and biological studies with synthetic compounds will be discussed in detail.


Assuntos
3',5'-AMP Cíclico Fosfodiesterases/antagonistas & inibidores , Inibidores de Fosfodiesterase/síntese química , Animais , Nucleotídeo Cíclico Fosfodiesterase do Tipo 4 , Cobaias , Masculino , Inibidores de Fosfodiesterase/farmacologia , Ratos , Ratos Sprague-Dawley , Relação Estrutura-Atividade
15.
Artigo em Inglês | MEDLINE | ID: mdl-25615207

RESUMO

We measured the average deuterium cluster size within a mixture of deuterium clusters and helium gas by detecting Rayleigh scattering signals. The average cluster size from the gas mixture was comparable to that from a pure deuterium gas when the total backing pressure and temperature of the gas mixture were the same as those of the pure deuterium gas. According to these measurements, the average size of deuterium clusters depends on the total pressure and not the partial pressure of deuterium in the gas mixture. To characterize the cluster source size further, a Faraday cup was used to measure the average kinetic energy of the ions resulting from Coulomb explosion of deuterium clusters upon irradiation by an intense ultrashort pulse. The deuterium ions indeed acquired a similar amount of energy from the mixture target, corroborating our measurements of the average cluster size. As the addition of helium atoms did not reduce the resulting ion kinetic energies, the reported results confirm the utility of using a known cluster source for beam-target-fusion experiments by introducing a secondary target gas.

16.
Artigo em Inglês | MEDLINE | ID: mdl-23496630

RESUMO

The kinetic energy of hot (multi-keV) ions from the laser-driven Coulomb explosion of deuterium clusters and the resulting fusion yield in plasmas formed from these exploding clusters has been investigated under a variety of conditions using the Texas Petawatt laser. An optimum laser intensity was found for producing neutrons in these cluster fusion plasmas with corresponding average ion energies of 14 keV. The substantial volume (1-10 mm(3)) of the laser-cluster interaction produced by the petawatt peak power laser pulse led to a fusion yield of 1.6×10(7) neutrons in a single shot with a 120 J, 170 fs laser pulse. Possible effects of prepulses are discussed.


Assuntos
Deutério/química , Deutério/efeitos da radiação , Lasers , Modelos Químicos , Nêutrons , Gases em Plasma/química , Gases em Plasma/efeitos da radiação , Simulação por Computador , Explosões , Fusão Nuclear , Eletricidade Estática
17.
Int J Impot Res ; 25(4): 149-54, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23303333

RESUMO

We evaluated the clinical efficacy and safety of the coadministration of a PDE5 inhibitor and an α-adrenergic blocker in patients with both benign prostatic hyperplasia/lower urinary tract symptoms (BPH-LUTS) and ED using mirodenafil 50 mg (Mvixx) once daily (OD) in patients already receiving stable α-blocker therapy. This study was a prospective, multicenter, open-label trial. We selected 147 patients undergoing stable (longer than 4 weeks) α-blocker therapy for BPH-LUTS as recipients of the additive mirodenafil 50 mg OD for 8 weeks. The coprimary measures were the International Prostate Symptom Score (IPSS) and the International Index of Erectile Function (IIEF-5). The key secondary measures were peak flow rate (Qmax) and postvoiding residual (PVR) volume. Safety was assessed by evaluating cardiovascular parameters and the participant-reported treatment-emergent adverse events (TEAEs). The additional administration of mirodenafil 50 mg OD significantly improved IPSS results (18.70-14.30 at 4 weeks and 18.70-13.72 at 8 weeks; P<0.001). The IIEF-5 score was improved at 8 weeks (10.94-16.16; P<0.001). There was no significant change in systolic blood pressure/diastolic blood pressure (124.8 mm Hg/78.6 mm Hg-122.0 mm Hg/79.6 mm Hg; P=0.638) and heart rates (78.8 per min to 80.2 per min; P=0.452). The most common TEAEs were hot flashes (10.9%) and headache (8.1%). The combination of mirodenafil with an α-blocker did not significantly improve PVR; however, Qmax was improved at 8 weeks (14.51-16.80 ml s(-1); P=0.026). Mirodenafil 50 mg OD in combination with an α-blocker appeared to have few adverse effects, to improve BPH-LUTS and restore sexual function.


Assuntos
Antagonistas Adrenérgicos alfa/administração & dosagem , Disfunção Erétil/tratamento farmacológico , Sintomas do Trato Urinário Inferior/tratamento farmacológico , Inibidores da Fosfodiesterase 5 , Hiperplasia Prostática/tratamento farmacológico , Pirimidinonas/administração & dosagem , Sulfonamidas/administração & dosagem , Antagonistas Adrenérgicos alfa/efeitos adversos , Adulto , Idoso , Pressão Sanguínea/efeitos dos fármacos , Disfunção Erétil/complicações , Frequência Cardíaca/efeitos dos fármacos , Humanos , Sintomas do Trato Urinário Inferior/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Hiperplasia Prostática/complicações , Pirimidinonas/efeitos adversos , Sulfonamidas/efeitos adversos
18.
Artigo em Inglês | MEDLINE | ID: mdl-24125372

RESUMO

We report on experiments in which the Texas Petawatt laser irradiated a mixture of deuterium or deuterated methane clusters and helium-3 gas, generating three types of nuclear fusion reactions: D(d,^{3}He)n, D(d,t)p, and ^{3}He(d,p)^{4}He. We measured the yields of fusion neutrons and protons from these reactions and found them to agree with yields based on a simple cylindrical plasma model using known cross sections and measured plasma parameters. Within our measurement errors, the fusion products were isotropically distributed. Plasma temperatures, important for the cross sections, were determined by two independent methods: (1) deuterium ion time of flight and (2) utilizing the ratio of neutron yield to proton yield from D(d,^{3}He)n and ^{3}He(d,p)^{4}He reactions, respectively. This experiment produced the highest ion temperature ever achieved with laser-irradiated deuterium clusters.

19.
Rev Sci Instrum ; 83(6): 063504, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22755624

RESUMO

Three types of neutron detectors (plastic scintillation detectors, indium activation detectors, and CR-39 track detectors) were calibrated for the measurement of 2.45 MeV DD fusion neutron yields from the deuterium cluster fusion experiment on the Texas Petawatt Laser. A Cf-252 neutron source and 2.45 MeV fusion neutrons generated from laser-cluster interaction were used as neutron sources. The scintillation detectors were calibrated such that they can detect up to 10(8) DD fusion neutrons per shot in current mode under high electromagnetic pulse environments. Indium activation detectors successfully measured neutron yields as low as 10(4) per shot and up to 10(11) neutrons. The use of a Cf-252 neutron source allowed cross calibration of CR-39 and indium activation detectors at high neutron yields (∼10(11)). The CR-39 detectors provided consistent measurements of the total neutron yield of Cf-252 when a modified detection efficiency of 4.6×10(-4) was used. The combined use of all three detectors allowed for a detection range of 10(4) to 10(11) neutrons per shot.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA