1.
J Refract Surg ; 27(5): 383-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21162473

RESUMO

PURPOSE: To report an unusual case of interface fluid syndrome after refractive surgery. METHODS: A 37-year-old man with high myopia underwent a planned bioptics procedure including creation of a corneal flap using a mechanical microkeratome and concurrent anterior chamber phakic intraocular lens implantation; excimer laser ablation was not performed at this time. RESULTS: Postoperatively, the patient developed corneal edema and was referred to our department. Interface fluid syndrome was confirmed using optical coherence tomography; the mechanism was due to endothelial cell pump dysfunction. CONCLUSIONS: This is the first report to document interface fluid syndrome following a planned bioptics procedure.


Assuntos
Córnea/cirurgia , Edema da Córnea/etiologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Lentes Intraoculares/efeitos adversos , Miopia/cirurgia , Adulto , Humanos , Masculino , Complicações Pós-Operatórias , Desenho de Prótese , Refração Ocular , Síndrome , Acuidade Visual