Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Echocardiography ; 36(4): 800-802, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30693549

RESUMO

Restrictive atrial communication is rarely reported in tricuspid atresia but when present it can lead to important morbidity. We describe two fetuses with tricuspid atresia with restrictive foramen ovale who were found to have fetal growth failure. Fetal echocardiography detected a restrictive atrial communication by flow acceleration on color Doppler and significant right atrial dilation in one patient; the atrial septum was not well interrogated in the other patient. Restrictive foramen ovale in tricuspid atresia may be associated with fetal growth failure. Color Doppler interrogation of the atrial septum on fetal echocardiogram may help identify this condition prenatally.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Retardo do Crescimento Fetal/etiologia , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Atresia Tricúspide/complicações , Ultrassonografia Pré-Natal/métodos , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Forame Oval/diagnóstico por imagem , Humanos , Gravidez , Atresia Tricúspide/diagnóstico por imagem
2.
Echocardiography ; 36(1): 142-149, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30506599

RESUMO

OBJECTIVES: Echocardiography is used to quantitatively characterize cardiovascular function in fetuses with cardiac abnormalities and inform decisions for fetal or perinatal interventions. It is clinically important to understand the reproducibility of these measures, particularly between testers. While studies have reported intra-observer variability and inter-observer variability, little is known about test-retest variability for these measures. We hypothesized that even in a high volume echocardiography laboratory, quantitative measurements will demonstrate higher test-retest variability compared with inter-observer variability and intra-observer variability of the same measurements. METHODS: Prospective study of uncomplicated, singleton pregnancies to evaluate fetal measures of cardiovascular function obtained by echocardiography. One sonographer obtained predefined variables, and then, a second sonographer obtained the same variables 15 minutes after the first sonographer. Separate data acquisitions were obtained by the two sonographers to evaluate test-retest variability. Intra-observer variability and inter-observer variability were also evaluated. RESULTS: Thirty fetuses between 17- and 36-week gestation were enrolled. Time-based variables had the best intra-observer agreement and inter-observer agreement (1.2%-7.4%), while 2D (7.5%-10%), M-mode (4.9%-10.1%), and velocity-time integral (VTI; 2.6%-13.8%) measurements had poorer agreement. For all variables, test-retest agreement was worse (3%-32.1%), particularly for measurement of myocardial performance index (MPI; 19.7%-21.1%), cardiac output estimation (27.2%-27.9%), and VTI-based indices (14.7%-32.1%). CONCLUSIONS: In a laboratory highly experienced in quantitative fetal echocardiography, intra-observer agreement and inter-observer agreement are good for most quantitative parameters. However, test-retest agreement is fair or poor for several variables, notably the MPI, cardiac output estimation, and VTI-based indices. Understanding how these measures vary between separate acquisitions is important for clinical interpretation and decision making.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Estudos de Avaliação como Assunto , Feminino , Humanos , Variações Dependentes do Observador , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA