Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Indian Pacing Electrophysiol J ; 24(5): 295-297, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38945297

RESUMO

Speech induced atrial tachycardia is peculiar and an extremely uncommon clinical situation. Though the exact patho-mechanism for such an association cannot be ascertained. It is postulated to be caused by cardiac autonomic modulation by vagal innervation around the ganglionated plexus (GP) of the heart. We hereby present a unique case of atrial tachycardia which could be induced only by speech and was successfully mapped and ablated on to the floor of left atrium (LA), which is a possible site of posteromedial left atrial ganglionated plexus.

2.
Catheter Cardiovasc Interv ; 102(7): 1364-1375, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37698335

RESUMO

BACKGROUND: Extremely large aortic valve anatomy is one of the remaining limitations leading to exclusion of patients for transcatheter aortic valve replacement (TAVR). AIMS: The newly approved Myval 32 mm device is designed for use in aortic annulus areas up to 840 mm2 . Here we want to share the initial worldwide experience with the device. METHODS AND RESULTS: Retrospective data were collected from 10 patients with aortic stenosis and very large annular anatomy (mean area 765.5 mm2 ), who underwent implantation with 32 mm Myval transcatheter heart valve at eight centers. Valve Academic Research Consortium-2 device success was achieved in all cases. Mild paravalvular leak was observed in three patients and two patients required new pacemaker implantation. One patient experienced retroperitoneal hemorrhage caused by the contralateral 6 F sheath and required surgical revision. No device-related complications, stroke, or death from any cause occurred within the 30-day follow-up period. In a studied cohort of 2219 consecutive TAVR-screened patients from a central European site, only 0.27% of patients showed larger anatomy than covered by the 32 mm Myval device by instructions for use without off-label use of overexpansion. This rate was significantly higher for the 34 mm Evolut Pro (1.8%) and 29 mm Sapien 3 (2.1%) devices. CONCLUSIONS: The Myval 32 mm prosthesis showed promising initial results in a cohort of patients who previously had to be excluded from TAVR. It is desirable that all future TAVR systems accommodate larger anatomy to allow optimal treatment of all patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos
3.
Cardiol Young ; 33(9): 1506-1516, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37518865

RESUMO

INTRODUCTION: Double-orifice mitral valve or left atrioventricular valve is a rare congenital cardiac anomaly that may be associated with an atrioventricular septal defect. The surgical management of double-orifice mitral valve/double-orifice left atrioventricular valve with atrioventricular septal defect is highly challenging with acceptable clinical outcomes. This meta-analysis is aimed to evaluate the surgical outcomes of double-orifice mitral valve/double-orifice left atrioventricular valve repair in patients with atrioventricular septal defect. METHODS AND RESULTS: A total of eight studies were retrieved from the literature by searching through PubMed, Google Scholar, Embase, and Cochrane databases. Using Bayesian hierarchical models, we estimated the pooled proportion of incidence of double-orifice mitral valve/double-orifice left atrioventricular valve with atrioventricular septal defect as 4.88% in patients who underwent surgical repair (7 studies; 3295 patients; 95% credible interval [CI] 4.2-5.7%). As compared to pre-operative regurgitation, the pooled proportions of post-operative regurgitation were significantly low in patients with moderate status: 5.1 versus 26.39% and severe status: 5.7 versus 29.38% [8 studies; 171 patients]. Moreover, the heterogeneity test revealed consistency in the data (p < 0.05). Lastly, the pooled estimated proportions of early and late mortality following surgical interventions were low, that is, 5 and 7.4%, respectively. CONCLUSION: The surgical management of moderate to severe regurgitation showed corrective benefits post-operatively and was associated with low incidence of early mortality and re-operation.


Assuntos
Cardiopatias Congênitas , Defeitos dos Septos Cardíacos , Insuficiência da Valva Mitral , Humanos , Lactente , Valva Mitral/cirurgia , Valva Mitral/anormalidades , Teorema de Bayes , Defeitos dos Septos Cardíacos/cirurgia , Cardiopatias Congênitas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Reoperação , Resultado do Tratamento
5.
J Vasc Bras ; 21: e20210223, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35911476

RESUMO

Internal thoracic artery aneurysms (ITAAs) are rare with wide variation in clinical presentation and a high risk of rupture. Endovascular techniques are increasingly being used for treatment of such aneurysms over surgical repair in recent times. A 34-year-old male presented with progressive swelling of the right anterior chest wall for 2 weeks and was diagnosed with right internal thoracic artery aneurysm with contained rupture. He underwent successful endovascular repair with coil embolization of ruptured right ITAA. Post intervention computed tomography (CT) angiography confirmed sealing of the ruptured aneurysm with no residual filling of the sac. At six months follow-up he is doing well with complete resolution of hematoma. This case demonstrates that an endovascular approach with coil embolization is a feasible and safe option for treating the rare ruptured ITAAs.


Os aneurismas da artéria torácica interna (ITAAs) são raros, com ampla variação na apresentação clínica e alto risco de ruptura. As técnicas endovasculares têm sido cada vez mais utilizadas para o tratamento desses aneurismas em relação ao reparo cirúrgico. Um homem de 34 anos de idade apresentou edema progressivo da parede torácica anterior direita por 2 semanas e foi diagnosticado com aneurisma da artéria mamária interna direita com ruptura contida. Ele foi submetido a reparo endovascular bem-sucedido, com embolização de ITAA direito roto. A angiotomografia computadorizada (angioTC) pós-intervenção confirmou o selamento do aneurisma rompido, sem enchimento residual do saco. No seguimento de 6 meses, ele estava bem, com resolução completa do hematoma. Este caso demonstra que a abordagem endovascular com embolização com molas é uma opção viável e segura no tratamento dos raros ITAAs rotos.

6.
J Cardiovasc Electrophysiol ; 32(4): 1065-1074, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33570234

RESUMO

BACKGROUND: Cardiac sympathetic denervation (CSD) is a useful therapeutic option in patients with structural heart disease (SHD) and ventricular tachycardia (VT) who are otherwise refractory to standard antiarrhythmic drug (AAD) therapy or catheter ablation (CA). In this study, we sought to retrospectively analyze the long-term outcomes of CSD in patients with refractory VT and/or VT storm with a majority of the patients being taken up for CSD ahead of CA. METHODS: We included consecutive patients with SHD who underwent CBD from 2010 to 2019 owing to refractory VT. A complete response to CSD was defined as a greater than 75% reduction in the frequency of ICD shocks for VT. RESULTS: A total of 65 patients (50 male, 15 female) were included. The underlying VT substrate was ischemic heart disease (IHD) in 30 (46.2%) patients while the remaining 35 (53.8%) patients had other nonischemic causes. The mean duration of follow-up was 27 ± 24 months. A complete response to CSD was achieved in 47 (72.3%) patients. There was a significant decline in the number of implantable cardioverter-defibrillator (ICD) or external defibrillator shocks post-CSD (24 ± 37 vs. 2 ± 4, p < .01). Freedom from a combined endpoint of ICD shock or death at 2 years was 51.5%. An advanced New York Heart Association class (III and IV) was the only parameter found to be associated with this combined endpoint. CONCLUSION: The current retrospective analysis re-emphasizes the role of surgical CSD and explores its role ahead of CA in the treatment of patients with refractory VT or VT storm.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Simpatectomia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
7.
Med J Armed Forces India ; 77(4): 413-418, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34594069

RESUMO

BACKGROUND: At our tertiary care cardiology center, we are receiving soldiers who sustained acute ST-Elevation Myocardial Infarction (STEMI) during the strenuous Battle Field Efficiency Test (BPET) and other such activities. METHODS: This was a single-center observational study to assimilate and analyze the precipitating causes, risk factors, symptoms, and the efficacy of the management protocols in soldiers sustaining STEMI during the BPET or other forms of strenuous military training. RESULTS: All 25 soldiers with documented STEMI following strenuous military training presented with chest pain as the primary symptom. 88% had symptoms either during or within 1st hour of the strenuous activity. 76% underwent thrombolysis with an angiographic success rate of 95%. Primary PCI was possible in only 3/25 (12%) of the cases, of which 2 (66%) did not require stenting after thrombus aspiration; 88% of soldiers reported "training for the event" for less than four times/week. CONCLUSION: STEMI precipitated by strenuous unaccustomed military training have exclusively single vessel affection with an excellent response to thrombolysis and thrombus aspiration. Thus, the timely institution of pharmacological or mechanical revascularization therapy has dramatic results in the preservation of ventricular function. The lack of training for the strenuous event provides strong evidence for comprehensive, graded, physical training prior to strenuous military activities to prevent acute coronary syndromes.

8.
J Card Surg ; 35(11): 3160-3165, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32939805

RESUMO

Ebstein's anomaly of the tricuspid valve is infrequently associated with left heart anomalies. The association of aortic stenosis in Ebstein's anomaly has been reported to be extremely rare and the association of coarctation of aorta is even rarer especially in adults. The combination of all three of these lesions is virtually unknown without any references in literature. We report here an unusual case of Ebstein's anomaly of the tricuspid valve and severe aortic stenosis with coarctation of aorta in an adult who presented to us with exertional dyspnoea in the third decade and underwent a successful single-stage intracardiac repair.


Assuntos
Coartação Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/métodos , Anomalia de Ebstein/cirurgia , Doenças Raras/cirurgia , Valva Tricúspide/anormalidades , Valva Tricúspide/cirurgia , Adulto , Coartação Aórtica/complicações , Estenose da Valva Aórtica/complicações , Dispneia/etiologia , Anomalia de Ebstein/complicações , Humanos , Masculino , Índice de Gravidade de Doença , Resultado do Tratamento , Adulto Jovem
9.
J Card Surg ; 35(8): 2059-2063, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32652648

RESUMO

Iatrogenic aortocoronary dissection is a rare but potentially fatal complication of coronary catheterizations. Although the incidence is comparatively low, dissection often leads to procedure failure with increased risk of myocardial infarction and death. Iatrogenic aortocoronary dissection is principally caused by disruption of intima at the ostia of the right or left coronary artery during interventional procedures and appears as luminal filling defects, the persistence of contrast or intimal tear outside the coronary lumen. We present a case of right coronary artery dissection leading to type-A aortic dissection suffered during diagnostic coronary catheterization. This required emergency supracoronary replacement of the ascending aorta with an aortic interposition tube graft and venous grafts to coronary arteries.


Assuntos
Aorta/cirurgia , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Valva Aórtica , Implante de Prótese Vascular/métodos , Cateterismo Cardíaco/efeitos adversos , Doença Iatrogênica , Tratamentos com Preservação do Órgão/métodos , Vasos Coronários , Feminino , Humanos , Pessoa de Meia-Idade
11.
Natl Med J India ; 29(1): 18-21, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27492031

RESUMO

Healthcare provider institutions in India now offer structured health check-up 'packages' for routine screening of common diseases. While some tests included within their ambit are in keeping with international and Indian recommendations, some are entirely unwarranted. Unnecessary and inappropriate screening tests may cause more harm than benefit. Besides financial and resource burden, there may be over-diagnosis and over-treatment, psychological distress due to false-positive test results, harm from invasive follow-up tests, and false reassurance due to false-negative test results. Clinicians must ensure a net benefit from tests and interventions in order to efficiently deliver preventive services. We reviewed current screening guidelines for cardiovascular disease and common cancers, and surveyed multiple 'packages' provided at 8 centres in Mumbai, India. We put forth our recommendations for routine health screening in asymptomatic adults in India.


Assuntos
Programas de Rastreamento , Adulto , Doenças Cardiovasculares/diagnóstico , Feminino , Humanos , Índia , Masculino , Programas de Rastreamento/economia , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Neoplasias/diagnóstico , Valor Preditivo dos Testes , Medição de Risco
12.
Am Heart J ; 169(1): 170-4, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25497263

RESUMO

BACKGROUND: Left-sided prosthetic valve thrombosis (PVT) is a serious complication of valve replacement. In developing countries, fibrinolysis with streptokinase (SK) is often used as the first line of treatment. Anti-streptokinase (anti-SK) antibodies are widely prevalent in the general population, but their effect on the efficacy and outcome of fibrinolysis with SK in patients with PVT is not known. METHODS: Patients with rheumatic heart disease and prosthetic valve replacement presenting with a first episode of left-sided PVT were enrolled. All patients underwent fibrinolysis with SK. An indirect enzyme-linked immunosorbent assay was used to detect anti-SK antibodies before fibrinolysis. Relationship of these antibodies to the outcome of fibrinolysis was evaluated. RESULTS: Forty-four patients treated for left-sided PVT were included. Thrombosis affected 33 mitral and 11 aortic prosthetic valves. On fibrinolysis with SK, 32 (73%) patients achieved complete success, whereas it was unsuccessful in the remaining 12 patients. There were 3 bleeding events, 1 stroke, and 3 deaths. Mean anti-SK antibody levels were not significantly different between patients who had complete success and those who did not (8.81 ± 2.43 vs 7.67 ± 1.26 Au/mL; P = .13) and did not correlate with the outcome after adjustment with other variables. Patients in New York Heart Association class III or IV had a greater chance of failed fibrinolytic therapy, even after adjustment for other prognostic variables (odds ratio 9.0; 95% CI 1.29-63.02; P = .027). CONCLUSION: Anti-SK antibody titers are not associated with success of fibrinolytic therapy using SK in patients with left-sided PVT.


Assuntos
Anticorpos/análise , Fibrinolíticos/uso terapêutico , Estreptoquinase/imunologia , Estreptoquinase/uso terapêutico , Adulto , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Terapia Trombolítica , Resultado do Tratamento , Adulto Jovem
13.
Indian Heart J ; 2024 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-39393567

RESUMO

INTRODUCTION: Difficult coronary sinus (CS) anatomy may lead to difficulty in optimal left ventricular (LV) lead placement and lead displacements leading to nonresponse to cardiac resynchronization therapy (CRT). METHODS: In this retrospective study, we studied the CRT parameters of devices implanted by single operator during the time period from January 2014 till December 2021, where different off-label techniques were used to place/stabilize LV lead. The technique used to stabilize LV lead, CRT parameters at baseline and follow up were noted for each patient. RESULTS: Out of 133 CRTs implanted during the study period, 23 patients (17.29 %) required off-label techniques. Stylet and guidewire retaining techniques were used in 11/23 (47.82 %) and 7/23 (30.43 %) patients respectively. In two patients, LV lead was jailed using coronary stent to prevent displacement. Two patients had CS stenosis and required balloon dilation while one patient had tortuous posterolateral vein which was straightened using a coronary stent. There was technical failure of 6/23 LV leads (26.08 %) with loss of capture, at a median follow up of 44 months (Range: 06-114 months). Out of these 6 patients, stylet and guidewire retaining techniques were used in 4 and 2 patients respectively. CONCLUSION: Despite having acceptable parameters at implantation, these techniques particularly stylet and guidewire retention, may lead to non-capture of LV lead on long term follow ups. Better LV leads like active fixation leads and conduction system pacing (His Bundle/left bundle branch pacing) should be preferred in difficult CS anatomy.

14.
Cureus ; 15(9): e45269, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37846270

RESUMO

The surgical treatment options for pediatric aortic valve disease are limited and have debatable long-term durability. In the current situation, the Ross procedure is considered in children for aortic valve disease(s). It is a complex surgical procedure with the risk of neo-aortic dilatation, converting a single valve disease into double valve disease, and associated with future re-interventions. Conversely, the Ozaki procedure has shown promising results in adults. Thus, the present study aimed to provide comparative evidence on the effectiveness and safety of the Ozaki versus Ross procedure for pediatric patients by performing a meta-analytic comparison of reporting outcomes. A total of 15 relevant articles were downloaded and among them, seven articles (one prospective study, five retrospective studies, and one case series) were used in the analysis. Primary outcomes such as physiological laminar flow pattern and hemodynamic parameters, and secondary outcomes such as hospital stays, adverse effects, mortality, and numbers of re-intervention(s) were measured in the meta-analysis. There were no significant differences in the age of patients between children who underwent the Ozaki procedure and those who underwent the Ross procedure at the time of surgeries. The Ozaki procedure is a good solution to an aortic problem(s) similar to the Ross procedure. Unlike the Ross procedure, the Ozaki procedure has restored a physiological laminar flow pattern in the short-term follow-up without the bi-valvular disease. Mean hospital stays (p = 0.048), mean follow-up (p = 0.02), adverse effects (p = 0.02), death, and numbers of re-intervention(s) of children who underwent the Ozaki procedure were fewer than those who underwent the Ross procedure. The time required for re-intervention(s) is higher for children who underwent the Ozaki procedure than those who underwent the Ross procedure. None of the procedures, including the Ozaki procedure for aortic valve disease(s), has significant effects on hemodynamic parameters and the frequent death rate of children after surgeries. Based on our analysis, we may suggest the Ozaki procedure for aortic valve disease surgery in children.

15.
Cureus ; 15(8): e44135, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37752999

RESUMO

Ventricular septal defect (VSD) is a catastrophic acute myocardial infarction (MI) complication. Despite a significant reduction in the prevalence of post-MI VSD with the advancement of surgical techniques, it is still considered fatal with a high mortality rate. The trends in the clinical outcomes of patients with post-MI VSD show discretion due to the complexity of the disease. Therefore, the present analysis aimed to evaluate the surgical outcomes and associated risks in the patients of post-MI VSD. A thorough literature survey resulted in 40 studies of our interest. The pooled proportion of differential variables, including the incidence of cardiogenic shock, 30-day survival, and overall mortality, were estimated using Bayesian hierarchical models. The risk difference was estimated for the location of MI and VSD and mortality in patients with coronary artery bypass graft (CABG). In addition, the heterogeneity tests for inconsistency and publication biases using Egger's and Begg's tests were also estimated. The analysis revealed a significant risk difference of 0.23 and 0.27 for the anterior vs. posterior location of MI and VSD, respectively. Further, the pooled proportion of 30-day survival and mortality was found to be 54.43% (95% credible interval (CI): 52.88-55.98%) and 48.22% (95% CI: 4-12.3%), respectively. Moreover, the heterogeneity test revealed significant inconsistencies in all the datasets with an I2 index of >90% (p<0.0001). Lastly, the publication bias results suggested no evidence of asymmetry and small-study effects. Conclusively, the surgical management of post-MI VSD patients is considered beneficial; however, the outcomes signify its fatal behavior.

16.
Indian Heart J ; 64(6): 588-90, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23253412

RESUMO

A 55 year old male patient with a diagnosis of hypertrophic cardiomyopathy was admitted with features of sepsis related to cholangitis. Initial management with intravenous (i.v.) fluids and antibiotics did not cause any change in his general condition mandating an emergency endoscopic retrograde cholangio-pancreatography (ERCP). After successful retrieval of CBD stone on ERCP, patient had massive upper gastrointestinal bleed leading to hypotension and shock. Addition of inotropes had led to further deterioration in his clinical status with a mean arterial BP falling to 44 mm of Hg. His echocardiography showed a resting left ventricular outflow tract (LVOT) gradient of 90 mm of Hg and thus was taken up for emergency alcohol septal ablation (ASA). Immediately after ASA, patient had significant decrease in LVOT obstruction and rise of systemic arterial pressures. After 10 days of antibiotic therapy patient was discharged with a residual LVOT obstruction of 28 mm of Hg.


Assuntos
Técnicas de Ablação/métodos , Cardiomiopatia Hipertrófica/tratamento farmacológico , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangite/complicações , Etanol/uso terapêutico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Insuficiência de Múltiplos Órgãos/etiologia , Sepse/etiologia , Obstrução do Fluxo Ventricular Externo/tratamento farmacológico , Obstrução do Fluxo Ventricular Externo/etiologia , Antibacterianos/uso terapêutico , Colangite/cirurgia , Ecocardiografia , Septos Cardíacos/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade
17.
J Invasive Cardiol ; 34(4): E346, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35366231

RESUMO

Ortner's syndrome is hoarseness of the voice caused by enlarged cardiac structures compressing the left recurrent laryngeal nerve (LRLN). The LRLN is vulnerable for impingement by cardiac structures due to its anatomical course. LRLN is longer and it hooks below the arch of the aorta, posterior to the ligamentum arteriosum before ascending toward the tracheo- esophageal groove. Ortner's syndrome has been commonly described with left atrial enlargement due to mitral stenosis; however, other causes like aortic aneurysm, pulmonary artery aneurysm, and aortic dissection have been described. Although rare, hoarseness of the voice could be the only presenting complaint in aortic aneurysms as in the case described herein.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Dissecção Aórtica , Paralisia das Pregas Vocais , Dissecção Aórtica/complicações , Aneurisma Aórtico/complicações , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico , Rouquidão/complicações , Rouquidão/etiologia , Humanos , Paralisia das Pregas Vocais/diagnóstico , Paralisia das Pregas Vocais/etiologia
18.
JACC Case Rep ; 4(8): 460-463, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35493797

RESUMO

A 74-year-old man presented with failure of a bioprosthetic aortic valve implanted 7 years earlier, with a mean gradient of 44 mm Hg across the aortic valve. During valve-in-valve transcatheter aortic valve replacement, we came across an unusual complication of strut inversion at the lower end of the valve. (Level of Difficulty: Advanced.).

19.
J Tehran Heart Cent ; 17(3): 147-151, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37252085

RESUMO

Inadvertent deployment of stent grafts into the false lumen during thoracic endovascular aortic repair (TEVAR) is rare and is associated with catastrophic consequences. We present a case of accidental stent-graft deployment from the true lumen into the false lumen during TEVAR, resulting in hemodynamic collapse and visceral malperfusion. We successfully performed a bailout using the Brockenbrough needle to create new access from the true lumen to the false lumen and implanted another overlapping stent graft.

20.
Indian Heart J ; 74(6): 500-504, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36460054

RESUMO

Atrial high rate episodes (AHRE) confers increased morbidity and mortality amongst patients with permanent pacemaker implantation (PPI). The incidence of AHREs and it's clinical predictors in Indian patients without prior history of atrial fibrillation (AF) are not well understood. A total of 100 dual-chamber PPI patients, who had no prior history of AF, underwent pacemaker interrogation starting from a minimum of 1 month after implantation to detect any AHREs. The incidence of AHREs was 17% at a mean follow up 15.2 ± 7.5 months. Only right ventricular apical lead position was found to have an independent association with AHREs (OR: 3.50, 95% CI: 1.02-12.03; p = 0.04).


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico , Incidência , Marca-Passo Artificial/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA