RESUMO
To determine whether 2 readily available indicators predicted survival among patients with Ebola virus disease in Sierra Leone, we evaluated information for 216 of the 227 patients in Bo District during a 4-month period. The indicators were time from symptom onset to healthcare facility admission and quantitative real-time reverse transcription PCR cycle threshold (Ct), a surrogate for viral load, in first Ebola virus-positive blood sample tested. Of these patients, 151 were alive when detected and had reported healthcare facility admission dates and Ct values available. Time from symptom onset to healthcare facility admission was not associated with survival, but viral load in the first Ebola virus-positive blood sample was inversely associated with survival: 52 (87%) of 60 patients with a Ct of >24 survived and 20 (22%) of 91 with a Ct of <24 survived. Ct values may be useful for clinicians making treatment decisions or managing patient or family expectations.
Assuntos
Ebolavirus , Doença pelo Vírus Ebola/mortalidade , Doença pelo Vírus Ebola/virologia , Adolescente , Adulto , Feminino , Doença pelo Vírus Ebola/epidemiologia , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Vigilância da População , Prognóstico , Serra Leoa/epidemiologia , Adulto JovemRESUMO
Yellow fever (YF), an arboviral disease, affects an estimated 200,000 people and causes 30,000 deaths per year and recently has caused major epidemics in Africa and South America. Timely and accurate diagnosis of YF is critical for managing outbreaks and implementing vaccination campaigns. A YF immunoglobulin M (IgM) antibody-capture (MAC) enzyme-linked immunosorbent assay (ELISA) kit, the YF MAC-HD, was successfully introduced starting in 2018 to laboratories in Africa and South America. The YF MAC-HD kit can be performed in 3.5 hours, test up to 24 samples, and includes all reagents necessary to perform the test, except for water used to dilute wash buffer. In 2018 and 2019, a total of 56 laboratory personnel from 39 countries in Africa and South America were trained to use the kit during workshops, followed by take-home YF IgM proficiency testing (PT) exercises. Participants received either a 10- or 20-sample YF PT panel and performed testing using the YF MAC-HD kit. All countries obtained 90% or higher correct results. These results verified the technical viability and transferability of YF MAC-HD kit use for laboratories in YF-endemic countries.
Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Febre Amarela/diagnóstico , Febre Amarela/epidemiologia , África Subsaariana/epidemiologia , Doenças Endêmicas , Humanos , Laboratórios , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , América do Sul/epidemiologiaRESUMO
BACKGROUND: Heartland virus (HRTV), a recently reclassified member of the genus Bandavirus, family Phenuiviridae, was first isolated in 2009 from a Missouri farmer exhibiting leukopenia and thrombocytopenia with suspected ehrlichiosis. Since then, more HRTV cases have been diagnosed, and firstline laboratory diagnostic assays are needed to identify future infections Objectives. We sought to develop rapid and reliable IgM and IgG microsphere immunoassays (MIAs) to test sera of patients suspected of having HRTV infection, and to distinguish between recent and past infections. STUDY DESIGN: Heartland virus antigen was captured by an anti-HRTV monoclonal antibody covalently bound to microspheres. Antibodies in human sera from confirmed HRTV-positive and negative cases were reacted with the microsphere complexes and detected using a BioPlex® 200 instrument. Assay cutoffs were determined by receiver operator characteristic analysis of the normalized test output values, equivocal zones for each assay were defined, and sensitivities, specificities, accuracies, and imprecision values were calculated. RESULTS: Sensitivities, specificities and accuracies of the IgM and IgG MIAs were all >95 %. Both tests were precise within and between assay plates, and cross-reactivity with other arboviruses was not observed. CONCLUSIONS: HRTV IgM and IgG MIAs are accurate and rapid first-line methods to serologically identify recent and past HRTV infections.
Assuntos
Phlebovirus , Anticorpos Antivirais , Antígenos Virais , Reações Cruzadas , Humanos , Imunoensaio , Imunoglobulina M , MicroesferasRESUMO
INTRODUCTION: accurate and timely laboratory diagnosis of yellow fever (YF) is critical to the Eliminate Yellow Fever Epidemics (EYE) strategy. Gavi, the Vaccine Alliance recognized the need to support and build capacity in the national and regional laboratories in the Global YF Laboratory Network (GYFLN) as part of this strategy. METHODS: to better understand current capacity, gaps and needs of the GYFLN laboratories in Africa, assessments were carried out in national and regional reference laboratories in the 25 African countries at high risk for YF outbreaks that were eligible for new financial support from Gavi. RESULTS: the assessments found that the GYFLN in Africa has high capacity but 21% of specimens were not tested due to lack of testing kits or reagents and approximately 50% of presumptive YF cases were not confirmed at the regional reference laboratory due to problems with shipping. CONCLUSION: the laboratory assessments helped to document the baseline capacities of these laboratories prior to Gavi funding to support strengthening YF laboratories.
Assuntos
Surtos de Doenças , Laboratórios/estatística & dados numéricos , Febre Amarela/diagnóstico , África/epidemiologia , Fortalecimento Institucional , Epidemias , Humanos , Febre Amarela/epidemiologiaRESUMO
ZIKV Detect™ 2.0 IgM Capture ELISA (InBios International, Seattle, WA) recently replaced the ZIKV Detect™ IgM Capture ELISA and a number of significant changes have been made to the original version. This study compares data generated from the ZIKV Detect™ 2.0 IgM Capture ELISA, to data generated using the original version of the kit. The same sample sets were used in this comparison, and reference test results for these samples were used to assess sensitivity, specificity, accuracy and concordance of results across two laboratories. Average sensitivity increased from 90.4% to 92.5% with the updated kit where the increase was not statistically different, and specificity increased from 79.5% to 97.4%, a statistically-significant difference. Accuracy of the ZIKV Detect™ 2.0 IgM Capture ELISA was 89% compared to 63.9% for the original version of the kit, and agreement across the laboratories increased from 79.5% to 97.4%. With secondary dengue virus infections, specificity increased from 9.3% to 82.6% with the updated kit, primarily due to the change in interpretation criteria that no longer includes "Possible Zika positive."
Assuntos
Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/normas , Imunoglobulina M/sangue , Kit de Reagentes para Diagnóstico/normas , Infecção por Zika virus/diagnóstico , Zika virus/isolamento & purificação , Técnicas de Laboratório Clínico , Ensaio de Imunoadsorção Enzimática/instrumentação , Humanos , Padrões de Referência , Sensibilidade e Especificidade , Infecção por Zika virus/sangueRESUMO
We report the case of an Ebola virus (EBOV) RNA-negative pregnant woman who delivered an EBOV RNA-positive stillborn infant at a community health center in rural Sierra Leone, 1 month after the mother's last possible exposure. The mother was later found to be immunoglobulins M and G positive indicating previous infection. The apparent absence of Ebola symptoms and not recognizing that the woman had previous contact with an Ebola patient led health workers performing the delivery to wear only minimal personal protection, potentially exposing them to a high risk of EBOV infection. This case emphasizes the importance of screening for epidemiological risk factors as well as classic and atypical symptoms of Ebola when caring for pregnant women, even once they have passed the typical time frame for exposure and incubation expected in nonpregnant adults. It also illustrates the need for health-care workers to use appropriate personal protection equipment when caring for pregnant women in an Ebola setting.
Assuntos
Ebolavirus/isolamento & purificação , Doença pelo Vírus Ebola/epidemiologia , Complicações Infecciosas na Gravidez/virologia , RNA Viral/isolamento & purificação , Natimorto , Agentes Comunitários de Saúde , Feminino , Humanos , Tocologia , Gravidez , Complicações Infecciosas na Gravidez/patologia , Serviços de Saúde Rural , Serra Leoa/epidemiologia , Carga Viral , Adulto JovemRESUMO
Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas.
Assuntos
Anticorpos Antivirais/sangue , Imunoglobulina M/sangue , Kit de Reagentes para Diagnóstico , Testes Sorológicos/métodos , Febre Amarela/diagnóstico , Vírus da Febre Amarela/imunologia , África , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , TemperaturaAssuntos
Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática , Imunoglobulina M/sangue , Proteínas não Estruturais Virais/imunologia , Infecção por Zika virus/diagnóstico , Zika virus/imunologia , Animais , Anticorpos Antivirais/imunologia , Chlorocebus aethiops , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Masculino , Sensibilidade e Especificidade , Células Vero , Infecção por Zika virus/virologiaRESUMO
Serum antibodies from myriad species, particularly birds, can provide key information regarding the transmission and the expansion of the territory of emerging pathogens. Expedient antibody analysis is constrained by a lack of species-specific reagents, a deficiency potentially highlighted by the recent swine-origin influenza A virus (H1N1) outbreak. Available methodologies present difficulties that discourage thorough serologic monitoring of potential disease vectors or hosts. Rapid high-throughput procedures that combined serum amine labeling via biotinylation, contaminant removal, and microsphere-based immunoassays for antibodies to three arboviruses were developed. Agent-specific adaptations of this simple format should facilitate expanded surveillance and diagnostic capabilities regarding pathogens of human and veterinary importance.