Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Neuroeng Rehabil ; 19(1): 131, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36457037

RESUMO

BACKGROUND: Exosuits have been shown to reduce metabolic cost of walking and to increase gait performance when used in clinical environment. Currently, these devices are transitioning to private use to facilitate independent training at home and in the community. However, their acceptance in unsupervised settings remains unclear. Therefore, the aim of this study was to investigate end-user perspectives and the adoption of an exosuit in domestic and community settings. METHODS: We conducted a mixed-method study to investigate the usability and user experience of an exosuit, the Myosuit. We leveraged on a cohort of seven expert users, who had the device available at home for at least 28 days. Each participant completed two standardized questionnaires (SUS and QUEST) and one personalized, custom questionnaire. Furthermore, a semi-structured interview with each participant was recorded, verbatim transcribed and analyzed using descriptive thematic analysis. Data collected from device sensors quantified the frequency of use. RESULTS: A mean SUS score of 75.4 out of 100 was reported. Five participants scored above the threshold for above-average usability. Participants also expressed high satisfaction with most of the technical features in the QUEST with an average score of 4.1 (3.86-4.71) out of 5. Participants used the Myosuit mainly for walking outside and exercising at home. However, the frequency of use did not meet the recommendations for physical activity established by the World Health Organization. Five participants used the Myosuit approximately once per week. The two other participants integrated the device in their daily life and used the Myosuit to a greater extent (approx. five times per week). Major factors that prevented an extensive use of the technology were: (i) difficulties in donning that led to (ii) lack of independence and (iii) lack of motivation in exercising. CONCLUSIONS: Although usable for various activities and well perceived, the adoption of the exosuit in domestic and community settings is yet limited. Use outside the clinic poses further challenges that should be considered when developing new wearable robots. Primarily, design should meet the users' claim for independence and increased adjustability of the device.


Assuntos
Exercício Físico , Caminhada , Humanos , Marcha , Motivação , Tecnologia
2.
Front Robot AI ; 11: 1335733, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38549947

RESUMO

Introduction: Children and adolescents with neurological impairments face reduced participation and independence in daily life activities due to walking difficulties. Existing assistive devices often offer insufficient support, potentially leading to wheelchair dependence and limiting physical activity and daily life engagement. Mobile wearable robots, such as exoskeletons and exosuits, have shown promise in supporting adults during activities of daily living but are underexplored for children. Methods: We conducted a cross-sectional study to examine the potential of a cable-driven exosuit, the Myosuit, to enhance walking efficiency in adolescents with diverse ambulatory impairments. Each participant walked a course including up-hill, down-hill, level ground walking, and stairs ascending and descending, with and without the exosuit's assistance. We monitored the time and step count to complete the course and the average heart rate and muscle activity. Additionally, we assessed the adolescents' perspective on the exosuit's utility using a visual analog scale. Results: Six adolescents completed the study. Although not statistically significant, five participants completed the course with the exosuit's assistance in reduced time (time reduction range: [-3.87, 17.42]%, p-value: 0.08, effect size: 0.88). The number of steps taken decreased significantly with the Myosuit's assistance (steps reduction range: [1.07, 15.71]%, p-value: 0.04, effect size: 0.90). Heart rate and muscle activity did not differ between Myosuit-assisted and unassisted conditions (p-value: 0.96 and 0.35, effect size: 0.02 and 0.42, respectively). Participants generally perceived reduced effort and increased safety with the Myosuit's assistance, especially during tasks involving concentric contractions (e.g., walking uphill). Three participants expressed a willingness to use the Myosuit in daily life, while the others found it heavy or too conspicuous. Discussion: Increased walking speed without increasing physical effort when performing activities of daily living could lead to higher levels of participation and increased functional independence. Despite perceiving the benefits introduced by the exosuit's assistance, adolescents reported the need for further modification of the device design before using it extensively at home and in the community.

3.
IEEE Int Conf Rehabil Robot ; 2023: 1-6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37941243

RESUMO

Exosuits typically provide limited mechanical support and rely on a user's residual functional ability. However, people with neurological impairments often suffer from both motor and sensory deficits that limit the assistance an exosuit can provide. To overcome these limitations, we developed the REINFORCE system, that complements the mechanical assistance provided by an exosuit, the Myosuit, with (1) functional electrical stimulation to enhance the activities of leg muscles, and (2) transcutaneous electrical nerve stimulation to restore somatosensory information. It consists of a fully portable and highly modular system that can be easily adapted to the level of impairment and specific need of each participant. Technical verification with three healthy participants showed reliable synchronization between all modules of the systems in all phases of walking. Additionally, we tested the system's effectiveness in one participant with multiple sclerosis who walked overground with and without functional electrical stimulation. Results showed a slight increase in self-selected walking speed (approx. 18%) and in the peak hip flexion at late swing (approx. 12%) as well as reduced step-to-step variability of step length and step time when electrical stimulation was provided. Our findings push towards a clinical trial involving more patients to validate the effectiveness of the REINFORCE system on participants' mobility.


Assuntos
Esclerose Múltipla , Caminhada , Humanos , Caminhada/fisiologia , Perna (Membro)/fisiologia , Músculo Esquelético , Atividades Cotidianas
4.
J Neural Eng ; 19(1)2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-34915454

RESUMO

Objective. Lower limb amputees suffer from a variety of functional deficits related to the absence of sensory communication between the central nervous system and the lost extremity. Indeed, they experience high risk of falls, asymmetric walking and balance, and low prosthesis embodiment, that significantly decrease their quality of life. Presently, there are no commercially available devices able to provide sensory feedback to leg amputees but recently some invasive solutions (i.e. requiring surgery) have been proposed by different research groups. However, a non-invasive effective alternative exploitable in everyday life is still missing.Approach. To address this need we developed and tested a lightweight, non-invasive, wearable technology (NeuroLegs) providing sensory (i.e. knee angle joint and tactile) feedback to the users through electro-cutaneous stimulation. Standard mechanical and electrical tests were performed to assess the safety and reliability of the technology. The NeuroLegs system was verified in terms of accuracy in measuring relevant gait parameters in healthy participants. The effectiveness of the NeuroLegs system at improving walking of three transfemoral amputees was then verified in movement laboratory tests.Main results. No mechanical failures, stable communication among system's parts and a long-lasting battery were demonstrated. A high temporal reliability was found when detecting stride features (important for the real-time configuration) with a correct match to the walking cadence in all assessed walking conditions. Finally, transfemoral amputees showed increased temporal gait symmetry and augmented confidence when walking with the sensory feedback compared to no feedback condition. Stepping outside from the lab, NeuroLegs was successfully exploited by a transfemoral amputee in CYBATHLON Global Edition 2020 in several challenging situations related to daily-living activities.Significance. Our results demonstrate that the NeuroLegs system provides the user with useful sensory information that can be successfully exploited in different walking conditions of daily life.


Assuntos
Amputados , Membros Artificiais , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Marcha , Humanos , Perna (Membro) , Extremidade Inferior , Qualidade de Vida , Reprodutibilidade dos Testes , Caminhada/fisiologia
5.
Sci Rep ; 12(1): 16696, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36202893

RESUMO

A non-optimal prosthesis integration into an amputee's body schema suggests some important functional and health consequences after lower limb amputation. These include low perception of a prosthesis as a part of the body, experiencing it as heavier than the natural limb, and cognitively exhausting use for users. Invasive approaches, exploiting the surgical implantation of electrodes in residual nerves, improved prosthesis integration by restoring natural and somatotopic sensory feedback in transfemoral amputees. A non-invasive alternative that avoids surgery would reduce costs and shorten certification time, significantly increasing the adoption of such systems. To explore this possibility, we compared results from a non-invasive, electro-cutaneous stimulation system to outcomes observed with the use of implants in above the knee amputees. This non-invasive solution was tested in transfemoral amputees through evaluation of their ability to perceive and recognize touch intensity and locations, or movements of a prosthesis, and its cognitive integration (through dual task performance and perceived prosthesis weight). While this managed to evoke the perception of different locations on the artificial foot, and closures of the leg, it was less performant than invasive solutions. Non-invasive stimulation induced similar improvements in dual motor and cognitive tasks compared to neural feedback. On the other hand, results demonstrate that remapped, evoked sensations are less informative and intuitive than the neural evoked somatotopic sensations. The device therefore fails to improve prosthesis embodiment together with its associated weight perception. This preliminary evaluation meaningfully highlights the drawbacks of non-invasive systems, but also demonstrates benefits when performing multiple tasks at once. Importantly, the improved dual task performance is consistent with invasive devices, taking steps towards the expedited development of a certified device for widespread use.


Assuntos
Membros Artificiais , Retroalimentação Sensorial , Amputados , Cognição , Retroalimentação , Humanos , Neuroestimuladores Implantáveis
6.
IEEE Int Conf Rehabil Robot ; 2022: 1-6, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36176094

RESUMO

Soft wearable robots to assist human movements, such as exosuits, have rapidly gained attention thanks to their compliance, low weight and accessibility. However, force measurement in exosuits still rely on load cells and rigid sensors that are not wearable or unsuitable for applications outside the lab. Soft, stretchable and lightweight sensors that become invisible when integrated in an exosuit and perfectly conform to the human body represent a promising alternative. In this work, we developed a wearable sensing system based on a soft stretchable silicone-based strain gauge to measure the forces acting in the passive elastic elements of an exosuit. To measure sensor's accuracy, two unimpaired participants walked on a treadmill at speeds between 0.9 and 2.1 $\text{m}\text{s}^{-1}$. When comparing our solution to a state-of-the-art motion capture system, we found an average root mean square error in force estimation of 12.5% and a standard deviation of 7.4%. Furthermore, we showed the portability of our sensory system by monitoring the forces exerted by the wearable robot during outdoor walking. Our study shows the potential of using stretchable sensors to monitor walking patterns in studies outside the lab and to control human-robot interaction.


Assuntos
Exoesqueleto Energizado , Robótica , Dispositivos Eletrônicos Vestíveis , Humanos , Silicones , Caminhada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA