Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Clin Invest ; 53(4): e13935, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36504276

RESUMO

BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in most heart failure patients, up to 40% do not respond to CRT. It has been suggested that multipoint left ventricle pacing (MPP) would increase the response rate. AIM: To assess the CRT response rate at 6 months in patients implanted with a CRT device with the MPP feature activated early after the implant. METHODS: This was a multicentre, prospective, open-label and non-randomized study. The primary endpoint was response to biventricular pacing defined as >15% relative reduction in left ventricular end-systolic volume (LVESV) comparing echocardiography measurements performed at baseline and 6 months by a core laboratory. Among secondary endpoints the combined endpoint of mortality or all-cause hospitalizations was evaluated. Primary study endpoint and clinical outcomes were compared to a Quarto II control cohort. RESULTS: Totally, 105 patients were included. The response rate was 64.6% (97.5% lower confidence bound 53%). Mean relative reduction in LVESV was 25.3%, and mean absolute increase in LVEF was 9.4%. The subjects with device programmed using anatomical approach showed a trend towards higher responder rate than those using the electrical approach (72% vs. 61.1%, p = 0.32). Finally, the combined incidence of mortality and or all-cause hospitalizations at 6 month was 12.4%. CONCLUSIONS: Early activation of MPP was not associated to an advantage increasing echocardiography responders to CRT at 6 months of follow-up. Nevertheless, patients programmed using widest pacing cathodes had a numerically higher responder rate. Finally, early activation of MPP was associated to a low incidence of clinical endpoints at 6 months of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Estudos Prospectivos , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Resultado do Tratamento , Dispositivos de Terapia de Ressincronização Cardíaca
2.
Int J Behav Nutr Phys Act ; 19(1): 6, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35073909

RESUMO

BACKGROUND: Recent lifestyle changes include increased consumption of highly processed foods (HPF), which has been associated with an increased risk of non-communicable diseases (NCDs). However, nutritional information relies on the estimation of HPF consumption from food-frequency questionnaires (FFQ) that are not explicitly developed for this purpose. We aimed to develop a short screening questionnaire of HPF consumption (sQ-HPF) that integrates criteria from the existing food classification systems. METHODS: Data from 4400 participants (48.1% female and 51.9% male, 64.9 ± 4.9 years) of the Spanish PREDIMED-Plus ("PREvention with MEDiterranean DIet") trial were used for this analysis. Items from the FFQ were classified according to four main food processing-based classification systems (NOVA, IARC, IFIC and UNC). Participants were classified into tertiles of HPF consumption according to each system. Using binomial logistic regression, food groups associated with agreement in the highest tertile for at least two classification systems were chosen as items for the questionnaire. ROC analysis was used to determine cut-off points for the frequency of consumption of each item, from which a score was calculated. Internal consistency of the questionnaire was assessed through exploratory factor analysis (EFA) and Cronbach's analysis, and agreement with the four classifications was assessed with weighted kappa coefficients. RESULTS: Regression analysis identified 14 food groups (items) associated with high HPF consumption for at least two classification systems. EFA showed that items were representative contributors of a single underlying factor, the "HPF dietary pattern" (factor loadings around 0.2). We constructed a questionnaire asking about the frequency of consumption of those items. The threshold frequency of consumption was selected using ROC analysis. Comparison of the four classification systems and the sQ-HPF showed a fair to high agreement. Significant changes in lifestyle characteristics were detected across tertiles of the sQ-HPF score. Longitudinal changes in HPF consumption were also detected by the sQ-HPF, concordantly with existing classification systems. CONCLUSIONS: We developed a practical tool to measure HPF consumption, the sQ-HPF. This may be a valuable instrument to study its relationship with NCDs. TRIAL REGISTRATION: Retrospectively registered at the International Standard Randomized Controlled Trial Registry ( ISRCTN89898870 ) on July 24, 2014.


Assuntos
Dieta Mediterrânea , Doenças não Transmissíveis , Dieta , Fast Foods , Feminino , Manipulação de Alimentos , Humanos , Masculino , Inquéritos e Questionários
3.
Scand J Clin Lab Invest ; 74(3): 192-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24484196

RESUMO

Short, middle, and long-term exercise, as well as the relative intensity of the physical effort, may influence a broad array of laboratory results, and it is thereby of pivotal importance to appropriately differentiate the 'physiologic' from the 'pathological' effects of exercise. Therefore, the values of some biomarkers in physically active subjects may be cautiously interpreted since the results may fall outside the conventional reference ranges. It has been demonstrated that middle and long-term endurance and/or strenuous exercise triggers transient elevations of muscular and cardiac biomarkers. However, no data have been published about the effect of short-term maximal exercise test on the most useful muscular, hepatic and cardiovascular biomarkers. The aim of the present study was to assess the baseline concentrations of muscular, hepatic, and cardiovascular makers between trained and untrained subjects, along with changes induced by maximal exercise test. We measured C reactive protein (CRP), procalcitonin (PCT), gamma glutamyltransferase (GGT), creatine kinase-MB isoenzyme (CK-MB), Hs-TnT, NT-proBNP, CK, LDH, AST, and ALT in serum samples of physically active (trained) and physically inactive (sedentary) male collected before, immediately after a maximal exercise test and after a 30-min recovery period. Trained subjects tend to have significantly raised base concentrations of CK, CK-MB, ALT, and LDH compared to sedentary individuals, and this can be clearly interpreted as a mild injury of skeletal muscle. A single maximal exercise was also effective to transiently increase the concentrations of NT-proBNP, but not those of Hs-TnT, thus suggesting that the cardiac involvement is mostly benign in nature.


Assuntos
Exercício Físico , Resistência Física , Esforço Físico , Adulto , Aspartato Aminotransferases/sangue , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Calcitonina/sangue , Peptídeo Relacionado com Gene de Calcitonina , Creatina Quinase Forma MB/sangue , Teste de Esforço , Coração/fisiologia , Humanos , L-Lactato Desidrogenase/sangue , Fígado/fisiologia , Masculino , Músculo Esquelético/fisiologia , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Precursores de Proteínas/sangue , Valores de Referência , Comportamento Sedentário , Troponina/sangue , gama-Glutamiltransferase/sangue
4.
Australas Phys Eng Sci Med ; 37(2): 377-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24756693

RESUMO

In recent years, several systems have been developed to control cardiac function during exercise, and some are also capable of recording RR data to provide heart rate variability (HRV) analyses. In this study we compare time between heart beats and HRV parameters obtained with a smart textile system (GOW; Weartech sl., Spain) and an electrocardiogram machine commonly used in hospitals during continuous cycling tests. Twelve cardiology patients performed a 30-min cycling test at stable submaximal intensity. RR interval data were recorded during the test by both systems. 3-min RR segments were taken to compare the time intervals between beats and HRV variables using Bland-Altman analyses and intraclass correlation coefficients. Limits of agreement (LoAs) on RR intervals were stable at around 3 ms (widest LoAs -5.754 to 6.094 ms, tightest LoAs -2.557 to 3.105 ms, medium LoAs -3.638 ± 0.812 to 3.145 ± 0.539 ms). HRV parameters related to short-term change presented wide LoAs (RMSSD -0.17 to 18.41 %, HF -17.64 to 33.21 %, SD1 -0.50 to 17.54 %) as an effect of the error measurement of the GOW system. The GOW system is a valid tool for controlling HR during physical activity, although its use as a clinical tool for HRV cannot be supported.


Assuntos
Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Idoso , Ciclismo , Teste de Esforço , Humanos , Masculino , Pessoa de Meia-Idade , Têxteis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA