1.
J Endovasc Ther ; : 15266028241240900, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38533777

RESUMO

PURPOSE: Endovascular repair of chronic post-dissection thoraco-abdominal aortic aneurysms (PD-TAAA) presents specific technical challenges due to the presence of chronic septum. Small true lumen diameter and false lumen visceral vessel origin can make branched endograft prohibitive. Septotomy may allow to overcome these challenges in cases of high complex anatomy. TECHNIQUE: We describe the application of electrocautery septotomy to the visceral aorta segment to deploy an off-the-shelf branched endograft in a chronic PD-TAAA rupture with true lumen collapse. CONCLUSIONS: Electrocautery septotomy can be an effective adjunctive technique to facilitate branched endograft, overcoming technical challenges associated with the endovascular treatment of chronic PD-TAAA. CLINICAL IMPACT: Electrocautery septotomy is an adjunctive technique that can facilitate endovascular treatment of post-dissection thoraco-abdominal aneurysm. By creating a common lumen, this technique might reduce the number of re-interventions associated with PD-TAAA endovascular exclusion.

2.
J Endovasc Ther ; : 15266028231163067, 2023 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37029570

RESUMO

PURPOSE: The aim of our study is to investigate the feasibility of retrograde cannulation using devices with inner branches (IB) for the endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs). MATERIALS AND METHODS: A retrospective analysis using IB configuration with retrograde cannulation was carried out on TAAAs patients undergoing endovascular treatment. RESULTS: Seven patients underwent IB endovascular treatment with retrograde cannulation between September 2020 and November 2021. The mean age was 80.4 years and 4 patients were male. A total of 26 of 28 target vessels were cannulated by retrograde access with a technical success of 93% (2 of 26 target vessels). Two intra-procedural complications were observed (1 renal artery dissection and 1 collateral renal artery rupture). In total, 26 of 28 treated vessels were retrograde cannulated with a technical success of 93%. A total of 39 stent bridges were used (all Viabahn VBX devices). The mean duration of the procedure was 321±102 minutes, and the mean scan time was 134±62 minutes. Mortality at 30 days was observed in 1 case. During the follow-up, 1 stent bridge occlusion was observed without the need for reintervention. CONCLUSION: Retrograde cannulation can also be successfully performed in the case of inner branches. CLINICAL IMPACT: In inner branched cases, retrograde cannulation should be taken into consideration in particular cases or it could become the option of choice. Dedicated endovascular material available such as steerable catheters and latest generation covered stents is fundamental for the success of the treatment.

3.
Healthcare (Basel) ; 12(1)2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38201025

RESUMO

BACKGROUND: Carotid artery stenting (CAS) using first-generation single-layer stents is widely accepted as a good alternative to standard carotid endarterectomy (CEA) but it is associated with worse outcomes in terms of both plaque prolapse and cerebral embolization. AIM: To evaluate the perioperative and midterm outcomes of CAS using the new-generation RoadsaverTM dual-layer micromesh-covered carotid stent. METHODS: Herein, we present the results of an observational, retrospective, multicentric study on non-consecutive patients who underwent the CAS procedure between January 2017 and December 2022 at three Italian, high-volume vascular surgery centers. The inclusion criteria were the patients' eligibility for the CAS procedure in accordance with the current Italian guidelines, and the implantation of a Roadsaver stent. Both symptomatic and asymptomatic patients were included in the study. The patients requiring reintervention for carotid restenosis following CEA were also included. Perioperative data regarding procedural success was defined as the successful implantation of the device in the desired position, less than 30% residual stenosis, and the absence of intraoperative neurological complications. The primary outcome was any adverse cerebrovascular event such as stroke or transient ischemic attack (TIA) during the procedure and/or after discharge. The secondary outcomes were the need for further intervention, and all-cause death following procedure. RESULTS: Three-hundred-fifty-three (353) patients were included in our study; the mean age was 74.3 years. A total of 5.9% of the patients were symptomatic on their operated side, while 7.3% had contralateral carotid occlusion. A cerebral embolic protection device (CPD) was employed in all patients. A total of 13.3% of the patients were operated on for restenosis after CEA Technical success was achieved in 96.9% of the cases with an intraoperative report of six TIAs (1.7%) and six ipsilateral strokes (1.7%). The mean hospital stay was 1.8 days. The thirty-day follow up showed one TIA and one more stroke. At the mean 35-month follow-up time, the primary outcome was present in six patients (1.7%), where four TIAs (1.1%) and two strokes (0.5%) were reported. Restenosis occurred in five patients (1.4%). Death for any cause was reported in 11 patients (3.1%). CONCLUSIONS: As most recent, high-quality studies show, the CAS procedure with second-generation devices such as the Roadsaver stent is safe and effective in preventing carotid-related cerebrovascular events in both symptomatic and asymptomatic patients. The intraoperative and postoperative cerebrovascular complication rate in high volume centers is very low, ensuring confidence in its employment for the CAS procedure along with a CPD as a valid alternative to CEA.

4.
J Cardiovasc Surg (Torino) ; 64(2): 150-158, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36897208

RESUMO

BACKGROUND: The GORE EXCLUDER Conformable Endoprosthesis with active control (CEXC) was developed to treat challenging aortic neck anatomy. This study investigated the clinical results and changes in endograft (ap)position during follow-up. METHODS: Patients treated with the CEXC between 2018 and 2022 were included in this prospective single-center study. Computed tomography angiography (CTA) follow-up was grouped into three categories: 0 to 6 (FU1), 7 to 18 (FU2), and 19 to 30 (FU3) months. Clinical end points were endograft-associated complications and reinterventions. CTA analysis included the shortest apposition length (SAL) between the endograft fabric and the first slice where circumferential apposition was lost, shortest fabric distance (SFD) between both renal arteries and the endograft fabric, and maximum infrarenal and suprarenal aortic curvature. FU2 and FU3 were compared with FU1 to establish changes. RESULTS: Included were 46 patients, of whom 36 (78%) had at least one hostile neck feature and 13 (28%) were treated outside instructions for use. Technical success was 100%. Median CTA follow-up was 10 months (2-20 months); 39 patients had a CTA available at FU1, 22 at FU2, and 12 at FU3. At FU1, the median SAL was 21.4 mm (13.2-27.4 mm), which did not significantly change during follow-up. No type I endoleaks, and one type III endoleak at an IBD occurred during follow-up. Two cases of endograft migration (SFD increase >10 mm) were seen during follow-up (one treated outside the instructions for use). Maximum infrarenal and suprarenal aortic curvature did not significantly change during follow-up. CONCLUSIONS: The use of the CEXC in challenging aortic necks enables stable apposition without significant changes in aortic morphology at short-term follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Correção Endovascular de Aneurisma , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Estudos Prospectivos , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Estudos Retrospectivos , Desenho de Prótese