Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pregnancy Childbirth ; 14: 81, 2014 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-24564622

RESUMO

BACKGROUND: Obstetric hemorrhage remains the leading cause of maternal mortality in resource limited areas. An inexpensive pneumatic anti-shock garment was devised of bicycle tubes and tailored cloth which can be prepared from local materials in resource-limited settings. The main purposes of this study were: 1) to determine acceptability of the device by nurses and midwives and obtain suggestions for making the device more suitable for use in their particular work environments, 2) to determine whether a three hour training course provided adequate instruction in the use of this device for the application of circumferential abdominal pelvic pressure, and 3) determine production capability and cost in a resource-limited country. METHODS: Fifty-eight nurse and midwife participants took part in three sessions over eight months in Nepal. Correct device placement was assessed on non-pregnant participants using ultrasound measurement of distal aortic flow before and after device inflation, and analyzed using confidence intervals. Participants were surveyed to determine acceptability of the device, obtain suggestions for improvement, and to collect data on clinical use. RESULTS: Device placement achieved flow decreases with a mean of 39% (95% CI 25%-53%, p < 0.001) in the first session, 28% (95% CI 21%-33%, P < 0.001) after four months and 29% (95% CI 24%-34%, p < 0.001) at 8 months. All nurses and midwives thought the device would be acceptable for use in obstetric hemorrhage and that they could make, clean, and apply it. They quickly learned to apply the device, remembered how to apply it, and were willing and able to use the device clinically. Ten providers used the device, each on one patient, to treat obstetric hemorrhage after routine measures had failed; bleeding stopped promptly in all ten, two of whom were transported to the hospital. Production of devices in Kathmandu using local tailors and supplies cost approximately $40 per device, in a limited production setting. CONCLUSIONS: Preliminary data suggest that an inexpensive, easily-made device is potentially an appropriate addition to current obstetric hemorrhage treatment in resource-limited areas and that further study is warranted.


Assuntos
Pessoal de Saúde/educação , Técnicas Hemostáticas/instrumentação , Tocologia/educação , Hemorragia Pós-Parto/terapia , Análise Custo-Benefício , Desenho de Equipamento , Feminino , Seguimentos , Técnicas Hemostáticas/economia , Humanos , Nepal , Gravidez , Estudos Retrospectivos
3.
Int J Emerg Med ; 3(3): 173-5, 2010 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-21031041

RESUMO

BACKGROUND: Pelvic bleeding from trauma and postpartum hemorrhage is often difficult to treat successfully by emergency providers particularly in low resource environments, when hospital presentation is delayed or there is a lack of immediate surgical, anesthesia, and transfusion capabilities. Pneumatic anti-shock garments (PASG) decrease pelvic blood flow and hemorrhage. A tightly fitted neoprene non-pneumatic anti-shock garment (NASG) has been shown to decrease blood loss and improve survival rates from postpartum hemorrhage. AIMS: The objective of this study was to determine whether blood flow to the pelvis is decreased by use of the NASG or by an improvised PASG. METHODS: A PASG was made using three bicycle tubes, placing one tube on each leg and one on the lower abdomen/pelvis, wrapping firmly with sheets and inflating the tubes to approximately 3.5 bar (45 psi). A Doppler ultrasound was used to measure distal aortic blood flow in 12 healthy adults at baseline and in both devices. Data were analyzed with one sample and paired t tests. RESULTS: Mean flow was 1.99 l/min at baseline. Mean flow decrease was 1.11 [95% confidence interval (CI): 0.64-1.57, p = 0.0003 for the difference] for the PASG and 0.65 (95% CI: 0.03-1.26, p = 0.04) for the NASG. The PASG decreased blood flow more than the NASG (mean difference: 0.46, 95% CI: 0.02-0.90, p = 0.04). CONCLUSIONS: Both devices decreased distal aortic blood flow, but the improvised PASG device decreased it by a larger margin.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA