Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
J Am Acad Dermatol ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604489

RESUMO

BACKGROUND: Epidermolysis bullosa (EB), characterized by skin fragility and blistering, often requires hospitalization. Training for inpatient management of EB is limited, with no unified recommendations available in North America. OBJECTIVE: To develop consensus-derived best practices for hands-on inpatient management of EB in both the neonatal and postneonatal period. METHODS: A modified Delphi method (expert-based input via 2 surveys and a final review) was implemented. Available guidelines from EB Clinical Research Consortium centers were analyzed to determine areas of focus and formulate statements to be voted on by EB Clinical Research Consortium members, experienced EB nurses, and select family members. Study participants evaluated statements using a Likert scale: statements with at least 70% agreement were accepted; statements with 30% or more disagreement were rejected. RESULTS: Ten areas of focus were identified. Delphi participants included 15 dermatologists, 8 nurses, and 6 nonhealth care caregivers. Consensus was established on 103/119 neonatal statements and 105/122 postneonatal statements; no statements were rejected. Most recommendations applied to both age groups. LIMITATIONS: Recommendations may require adjustment based on individual patient's clinical context. CONCLUSION: Using the Delphi method, a consensus-derived resource for hospital-based health care professionals who manage patients with EB has been developed to improve the quality of inpatient care.

2.
Pediatr Dermatol ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38889768

RESUMO

A 14-year-old boy developed an erythema multiforme-like reaction following Toxicodendron radicans (poison ivy) allergic contact dermatitis three separate times over the course of 3 years. The severity of each erythema multiforme-like reaction corresponded to the severity of the allergic contact dermatitis which preceded it.

3.
Pediatr Dermatol ; 40(1): 176-178, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36017700

RESUMO

MED12-related disorders represent a spectrum of rare neurodevelopmental disorders causing intellectual disability, dysmorphic features, and other systemic abnormalities. We report a case of a 21-month-old girl with extensive hypopigmentation following Blaschko lines attributed to underlying MED12-related disorder.


Assuntos
Hipopigmentação , Deficiência Intelectual , Transtornos do Neurodesenvolvimento , Feminino , Humanos , Lactente , Complexo Mediador
4.
J Am Acad Dermatol ; 86(5): 1063-1071, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34634382

RESUMO

BACKGROUND: Accurate diagnosis of epidermolysis bullosa (EB) has significant implications for prognosis, management, and genetic counseling. OBJECTIVE: To describe diagnostic testing patterns and assess diagnostic concordance of transmission electron microscopy (TEM), immunofluorescence mapping (IFM), and genetic analysis for EB. METHODS: A retrospective cohort included patients enrolled in the Epidermolysis Bullosa Clinical Characterization and Outcomes Database from January 1, 2004, to July 8, 2019. Tests concluding the same EB type (EB simplex, junctional EB, dominant dystrophic EB, and recessive dystrophic EB) were considered concordant; those concluding different EB types were considered discordant; and those with nonspecific/nondefinitive results were equivocal. RESULTS: A total of 970 diagnostic tests were conducted from 1984 to 2018 in 771 patients. Genetic analyses were performed chronologically later than IFM or TEM (P < .001). The likelihood of undergoing genetic analysis was greater for junctional EB and recessive dystrophic EB, and the same for dominant dystrophic EB as compared with EB simplex. TEM results in 163 patients were equivocal (55%), concordant (42%), and discordant (3%). IFM results in 185 patients were equivocal (54%), concordant (42%), and discordant (4%). LIMITATIONS: Retrospective design. CONCLUSIONS: Diagnostic testing has shifted in favor of genetic analysis. TEM and IFM frequently offer equivocal findings when compared to the specificity afforded by genetic analysis.


Assuntos
Epidermólise Bolhosa Distrófica , Epidermólise Bolhosa Simples , Epidermólise Bolhosa Juncional , Epidermólise Bolhosa , Epidermólise Bolhosa/diagnóstico , Epidermólise Bolhosa/genética , Epidermólise Bolhosa Distrófica/diagnóstico , Epidermólise Bolhosa Simples/diagnóstico , Imunofluorescência , Humanos , América do Norte , Estudos Retrospectivos
5.
Cochrane Database Syst Rev ; 7: CD011964, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35879201

RESUMO

BACKGROUND: Ovarian cancer (OC) has the highest case fatality rate of all gynaecological cancers. Diagnostic delays are caused by non-specific symptoms. Existing systematic reviews have not comprehensively covered tests in current practice, not estimated accuracy separately in pre- and postmenopausal women, or used inappropriate meta-analytic methods. OBJECTIVES: To establish the accuracy of combinations of menopausal status, ultrasound scan (USS) and biomarkers for the diagnosis of ovarian cancer in pre- and postmenopausal women and compare the accuracy of different test combinations. SEARCH METHODS: We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), five other databases and three trial registries from 1991 to 2015 and MEDLINE (Ovid) and Embase (Ovid) form June 2015 to June 2019. We also searched conference proceedings from the European Society of Gynaecological Oncology, International Gynecologic Cancer Society, American Society of Clinical Oncology and Society of Gynecologic Oncology, ZETOC and Conference Proceedings Citation Index (Web of Knowledge). We searched reference lists of included studies and published systematic reviews. SELECTION CRITERIA: We included cross-sectional diagnostic test accuracy studies evaluating single tests or comparing two or more tests, randomised trials comparing two or more tests, and studies validating multivariable models for the diagnosis of OC investigating test combinations, compared with a reference standard of histological confirmation or clinical follow-up in women with a pelvic mass (detected clinically or through USS) suspicious for OC. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and assessed quality using QUADAS-2. We used the bivariate hierarchical model to indirectly compare tests at commonly reported thresholds in pre- and postmenopausal women separately. We indirectly compared tests across all thresholds and estimated sensitivity at fixed specificities of 80% and 90% by fitting hierarchical summary receiver operating characteristic (HSROC) models in pre- and postmenopausal women separately. MAIN RESULTS: We included 59 studies (32,059 women, 9545 cases of OC). Two tests evaluated the accuracy of a combination of menopausal status and USS findings (IOTA Logistic Regression Model 2 (LR2) and the Assessment of Different NEoplasias in the adneXa model (ADNEX)); one test evaluated the accuracy of a combination of menopausal status, USS findings and serum biomarker CA125 (Risk of Malignancy Index (RMI)); and one test evaluated the accuracy of a combination of menopausal status and two serum biomarkers (CA125 and HE4) (Risk of Ovarian Malignancy Algorithm (ROMA)). Most studies were at high or unclear risk of bias in participant, reference standard, and flow and timing domains. All studies were in hospital settings. Prevalence was 16% (RMI, ROMA), 22% (LR2) and 27% (ADNEX) in premenopausal women and 38% (RMI), 45% (ROMA), 52% (LR2) and 55% (ADNEX) in postmenopausal women. The prevalence of OC in the studies was considerably higher than would be expected in symptomatic women presenting in community-based settings, or in women referred from the community to hospital with a suspicion of OC. Studies were at high or unclear applicability because presenting features were not reported, or USS was performed by experienced ultrasonographers for RMI, LR2 and ADNEX. The higher sensitivity and lower specificity observed in postmenopausal compared to premenopausal women across all index tests and at all thresholds may reflect highly selected patient cohorts in the included studies. In premenopausal women, ROMA at a threshold of 13.1 (± 2), LR2 at a threshold to achieve a post-test probability of OC of 10% and ADNEX (post-test probability 10%) demonstrated a higher sensitivity (ROMA: 77.4%, 95% CI 72.7% to 81.5%; LR2: 83.3%, 95% CI 74.7% to 89.5%; ADNEX: 95.5%, 95% CI 91.0% to 97.8%) compared to RMI (57.2%, 95% CI 50.3% to 63.8%). The specificity of ROMA and ADNEX were lower in premenopausal women (ROMA: 84.3%, 95% CI 81.2% to 87.0%; ADNEX: 77.8%, 95% CI 67.4% to 85.5%) compared to RMI 92.5% (95% CI 90.3% to 94.2%). The specificity of LR2 was comparable to RMI (90.4%, 95% CI 84.6% to 94.1%). In postmenopausal women, ROMA at a threshold of 27.7 (± 2), LR2 (post-test probability 10%) and ADNEX (post-test probability 10%) demonstrated a higher sensitivity (ROMA: 90.3%, 95% CI 87.5% to 92.6%; LR2: 94.8%, 95% CI 92.3% to 96.6%; ADNEX: 97.6%, 95% CI 95.6% to 98.7%) compared to RMI (78.4%, 95% CI 74.6% to 81.7%). Specificity of ROMA at a threshold of 27.7 (± 2) (81.5, 95% CI 76.5% to 85.5%) was comparable to RMI (85.4%, 95% CI 82.0% to 88.2%), whereas for LR2 (post-test probability 10%) and ADNEX (post-test probability 10%) specificity was lower (LR2: 60.6%, 95% CI 50.5% to 69.9%; ADNEX: 55.0%, 95% CI 42.8% to 66.6%). AUTHORS' CONCLUSIONS: In specialist healthcare settings in both premenopausal and postmenopausal women, RMI has poor sensitivity. In premenopausal women, ROMA, LR2 and ADNEX offer better sensitivity (fewer missed cancers), but for ROMA and ADNEX this is off-set by a decrease in specificity and increase in false positives. In postmenopausal women, ROMA demonstrates a higher sensitivity and comparable specificity to RMI. ADNEX has the highest sensitivity in postmenopausal women, but reduced specificity. The prevalence of OC in included studies is representative of a highly selected referred population, rather than a population in whom referral is being considered. The comparative accuracy of tests observed here may not be transferable to non-specialist settings. Ultimately health systems need to balance accuracy and resource implications to identify the most suitable test.


Assuntos
Neoplasias Ovarianas , Biomarcadores , Carcinoma Epitelial do Ovário , Estudos Transversais , Feminino , Humanos , Menopausa , Neoplasias Ovarianas/diagnóstico por imagem , Sensibilidade e Especificidade
6.
Pediatr Dermatol ; 38(6): 1577-1578, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34647347

RESUMO

Transverse testicular ectopia is a rare structural anomaly of abnormal testicular descent. We report a case of a 3-month-old boy with hemiscrotal infantile hemangioma and contralateral transverse testicular ectopia.


Assuntos
Neoplasias dos Genitais Masculinos , Hemangioma Capilar , Hemangioma , Hemangioma/diagnóstico , Hemangioma/cirurgia , Humanos , Lactente , Masculino , Escroto
7.
Pediatr Dermatol ; 38(4): 899-903, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34152030

RESUMO

Sinus pericranii is a rare vascular anomaly characterized by an abnormal communication between the intra- and extracranial venous systems through a calvarial defect(s). We present three cases of congenital sinus pericranii with facial involvement, emphasizing its cutaneous presentation with diagnostic pitfalls and discuss the multidisciplinary management of this vascular anomaly.


Assuntos
Seio Pericrânio , Malformações Vasculares , Administração Cutânea , Face , Humanos , Seio Pericrânio/diagnóstico
8.
Am J Hum Genet ; 100(6): 978-984, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28575652

RESUMO

The discovery of new genetic determinants of inherited skin disorders has been instrumental to the understanding of epidermal function, differentiation, and renewal. Here, we show that mutations in KDSR (3-ketodihydrosphingosine reductase), encoding an enzyme in the ceramide synthesis pathway, lead to a previously undescribed recessive Mendelian disorder in the progressive symmetric erythrokeratoderma spectrum. This disorder is characterized by severe lesions of thick scaly skin on the face and genitals and thickened, red, and scaly skin on the hands and feet. Although exome sequencing revealed several of the KDSR mutations, we employed genome sequencing to discover a pathogenic 346 kb inversion in multiple probands, and cDNA sequencing and a splicing assay established that two mutations, including a recurrent silent third base change, cause exon skipping. Immunohistochemistry and yeast complementation studies demonstrated that the mutations cause defects in KDSR function. Systemic isotretinoin therapy has achieved nearly complete resolution in the two probands in whom it has been applied, consistent with the effects of retinoic acid on alternative pathways for ceramide generation.


Assuntos
Oxirredutases do Álcool/genética , Genes Recessivos , Predisposição Genética para Doença , Ceratose/enzimologia , Ceratose/genética , Mutação/genética , Ceramidas/biossíntese , Proteínas Filagrinas , Teste de Complementação Genética , Heterozigoto , Humanos , Proteínas de Filamentos Intermediários/metabolismo , Polimorfismo de Nucleotídeo Único/genética , Splicing de RNA/genética , Saccharomyces cerevisiae/metabolismo
9.
Europace ; 22(5): 748-760, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32227238

RESUMO

AIMS: We assessed the performance of modelsf (risk scores) for predicting recurrence of atrial fibrillation (AF) in patients who have undergone catheter ablation. METHODS AND RESULTS: Systematic searches of bibliographic databases were conducted (November 2018). Studies were eligible for inclusion if they reported the development, validation, or impact assessment of a model for predicting AF recurrence after ablation. Model performance (discrimination and calibration) measures were extracted. The Prediction Study Risk of Bias Assessment Tool (PROBAST) was used to assess risk of bias. Meta-analysis was not feasible due to clinical and methodological differences between studies, but c-statistics were presented in forest plots. Thirty-three studies developing or validating 13 models were included; eight studies compared two or more models. Common model variables were left atrial parameters, type of AF, and age. Model discriminatory ability was highly variable and no model had consistently poor or good performance. Most studies did not assess model calibration. The main risk of bias concern was the lack of internal validation which may have resulted in overly optimistic and/or biased model performance estimates. No model impact studies were identified. CONCLUSION: Our systematic review suggests that clinical risk prediction of AF after ablation has potential, but there remains a need for robust evaluation of risk factors and development of risk scores.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração , Humanos , Prognóstico , Recidiva , Fatores de Risco , Resultado do Tratamento
10.
Neurourol Urodyn ; 39(2): 863-870, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31845393

RESUMO

AIMS: Antenatal pelvic floor muscle training (PFMT) may be effective for the prevention and treatment of urinary and fecal incontinence both in pregnancy and postnatally, but it is not routinely implemented in practice despite guideline recommendations. This review synthesizes evidence that exposes challenges, opportunities, and concerns regarding the implementation of PFMT during the childbearing years, from the perspective of individuals, healthcare professionals (HCPs), and organizations. METHODS: Critical interpretive synthesis of systematically identified primary quantitative or qualitative studies or research syntheses of women's and HCPs attitudes, beliefs, or experiences of implementing PFMT. RESULTS: Fifty sources were included. These focused on experiences of postnatal urinary incontinence (UI) and perspectives of individual postnatal women, with limited evidence exploring the views of antenatal women and HCP or wider organizational and environmental issues. The concept of agency (people's ability to effect change through their interaction with other people, processes, and systems) provides an over-arching explanation of how PFMT can be implemented during childbearing years. This requires both individual and collective action of women, HCPs, maternity services and organizations, funders and policymakers. CONCLUSION: Numerous factors constrain women's and HCPs capacity to implement PFMT. It is unrealistic to expect women and HCPs to implement PFMT without reforming policy and service delivery. The implementation of PFMT during pregnancy, as recommended by antenatal care and UI management guidelines, requires policymakers, organizations, HCPs, and women to value the prevention of incontinence throughout women's lives by using low-risk, low-cost, and proven strategies as part of women's reproductive health.


Assuntos
Diafragma da Pelve , Modalidades de Fisioterapia , Cuidado Pré-Natal , Transtornos Puerperais/prevenção & controle , Incontinência Urinária/prevenção & controle , Atitude do Pessoal de Saúde , Atitude Frente a Saúde , Atenção à Saúde , Terapia por Exercício , Incontinência Fecal/prevenção & controle , Incontinência Fecal/terapia , Feminino , Política de Saúde , Humanos , Guias de Prática Clínica como Assunto , Gravidez , Complicações na Gravidez , Transtornos Puerperais/terapia , Pesquisa Qualitativa , Reino Unido , Incontinência Urinária/terapia
11.
Pediatr Dermatol ; 37(5): 977-978, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32757310

RESUMO

It has been clinically speculated that the use of oil for hair grooming may change detection of fungus on culture; however, the effect of hair oil on fungal cultures remains poorly studied. In this prospective case-controlled study, scalp cultures were collected from twenty-eight pediatric patients with clinically suspected tinea capitis before and after cosmetic hair oil was rubbed into the scalp. Following hair oil application, fifteen of the sixteen originally positive patients tested positive, while one patient that had tested negative prior to hair oil had a positive culture. Our study suggests that recent hair oil application has minimal effect on the sensitivity of fungal culture for tinea capitis and we can rely on our standard fungal cultures with or without hair oil.


Assuntos
Couro Cabeludo , Criança , Cabelo , Humanos , Estudos Prospectivos , Tinha do Couro Cabeludo/diagnóstico , Tinha do Couro Cabeludo/tratamento farmacológico , Trichophyton
12.
Cochrane Database Syst Rev ; 5: CD012245, 2019 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-31087568

RESUMO

BACKGROUND: Stillbirth affects 2.6 million pregnancies worldwide each year. Whilst the majority of cases occur in low- and middle-income countries, stillbirth remains an important clinical issue for high-income countries (HICs) - with both the UK and the USA reporting rates above the mean for HICs. In HICs, the most frequently reported association with stillbirth is placental dysfunction. Placental dysfunction may be evident clinically as fetal growth restriction (FGR) and small-for-dates infants. It can be caused by placental abruption or hypertensive disorders of pregnancy and many other disorders and factorsPlacental abnormalities are noted in 11% to 65% of stillbirths. Identification of FGA is difficult in utero. Small-for-gestational age (SGA), as assessed after birth, is the most commonly used surrogate measure for this outcome. The degree of SGA is associated with the likelihood of FGR; 30% of infants with a birthweight < 10th centile are thought to be FGR, while 70% of infants with a birthweight < 3rd centile are thought to be FGR. Critically, SGA is the most significant antenatal risk factor for a stillborn infant. Correct identification of SGA infants is associated with a reduction in the perinatal mortality rate. However, currently used tests, such as measurement of symphysis-fundal height, have a low reported sensitivity and specificity for the identification of SGA infants. OBJECTIVES: The primary objective was to assess and compare the diagnostic accuracy of ultrasound assessment of fetal growth by estimated fetal weight (EFW) and placental biomarkers alone and in any combination used after 24 weeks of pregnancy in the identification of placental dysfunction as evidenced by either stillbirth, or birth of a SGA infant. Secondary objectives were to investigate the effect of clinical and methodological factors on test performance. SEARCH METHODS: We developed full search strategies with no language or date restrictions. The following sources were searched: MEDLINE, MEDLINE In Process and Embase via Ovid, Cochrane (Wiley) CENTRAL, Science Citation Index (Web of Science), CINAHL (EBSCO) with search strategies adapted for each database as required; ISRCTN Registry, UK Clinical Trials Gateway, WHO International Clinical Trials Portal and ClinicalTrials.gov for ongoing studies; specialist abstract and conference proceeding resources (British Library's ZETOC and Web of Science Conference Proceedings Citation Index). Search last conducted in Ocober 2016. SELECTION CRITERIA: We included studies of pregnant women of any age with a gestation of at least 24 weeks if relevant outcomes of pregnancy (live birth/stillbirth; SGA infant) were assessed. Studies were included irrespective of whether pregnant women were deemed to be low or high risk for complications or were of mixed populations (low and high risk). Pregnancies complicated by fetal abnormalities and multi-fetal pregnancies were excluded as they have a higher risk of stillbirth from non-placental causes. With regard to biochemical tests, we included assays performed using any technique and at any threshold used to determine test positivity. DATA COLLECTION AND ANALYSIS: We extracted the numbers of true positive, false positive, false negative, and true negative test results from each study. We assessed risk of bias and applicability using the QUADAS-2 tool. Meta-analyses were performed using the hierarchical summary ROC model to estimate and compare test accuracy. MAIN RESULTS: We included 91 studies that evaluated seven tests - blood tests for human placental lactogen (hPL), oestriol, placental growth factor (PlGF) and uric acid, ultrasound EFW and placental grading and urinary oestriol - in a total of 175,426 pregnant women, in which 15,471 pregnancies ended in the birth of a small baby and 740 pregnancies which ended in stillbirth. The quality of included studies was variable with most domains at low risk of bias although 59% of studies were deemed to be of unclear risk of bias for the reference standard domain. Fifty-three per cent of studies were of high concern for applicability due to inclusion of only high- or low-risk women.Using all available data for SGA (86 studies; 159,490 pregnancies involving 15,471 SGA infants), there was evidence of a difference in accuracy (P < 0.0001) between the seven tests for detecting pregnancies that are SGA at birth. Ultrasound EFW was the most accurate test for detecting SGA at birth with a diagnostic odds ratio (DOR) of 21.3 (95% CI 13.1 to 34.6); hPL was the most accurate biochemical test with a DOR of 4.78 (95% CI 3.21 to 7.13). In a hypothetical cohort of 1000 pregnant women, at the median specificity of 0.88 and median prevalence of 19%, EFW, hPL, oestriol, urinary oestriol, uric acid, PlGF and placental grading will miss 50 (95% CI 32 to 68), 116 (97 to 133), 124 (108 to 137), 127 (95 to 152), 139 (118 to 154), 144 (118 to 161), and 144 (122 to 161) SGA infants, respectively. For the detection of pregnancies ending in stillbirth (21 studies; 100,687 pregnancies involving 740 stillbirths), in an indirect comparison of the four biochemical tests, PlGF was the most accurate test with a DOR of 49.2 (95% CI 12.7 to 191). In a hypothetical cohort of 1000 pregnant women, at the median specificity of 0.78 and median prevalence of 1.7%, PlGF, hPL, urinary oestriol and uric acid will miss 2 (95% CI 0 to 4), 4 (2 to 8), 6 (6 to 7) and 8 (3 to 13) stillbirths, respectively. No studies assessed the accuracy of ultrasound EFW for detection of pregnancy ending in stillbirth. AUTHORS' CONCLUSIONS: Biochemical markers of placental dysfunction used alone have insufficient accuracy to identify pregnancies ending in SGA or stillbirth. Studies combining U and placental biomarkers are needed to determine whether this approach improves diagnostic accuracy over the use of ultrasound estimation of fetal size or biochemical markers of placental dysfunction used alone. Many of the studies included in this review were carried out between 1974 and 2016. Studies of placental substances were mostly carried out before 1991 and after 2013; earlier studies may not reflect developments in test technology.


Assuntos
Desenvolvimento Fetal/fisiologia , Recém-Nascido Pequeno para a Idade Gestacional , Placenta/diagnóstico por imagem , Resultado da Gravidez , Ultrassonografia Pré-Natal , Feminino , Retardo do Crescimento Fetal , Humanos , Recém-Nascido , Mortalidade Perinatal , Gravidez , Natimorto
13.
Cochrane Database Syst Rev ; 7: CD012806, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31260100

RESUMO

BACKGROUND: Melanoma is one of the most aggressive forms of skin cancer, with the potential to metastasise to other parts of the body via the lymphatic system and the bloodstream. Melanoma accounts for a small percentage of skin cancer cases but is responsible for the majority of skin cancer deaths. Various imaging tests can be used with the aim of detecting metastatic spread of disease following a primary diagnosis of melanoma (primary staging) or on clinical suspicion of disease recurrence (re-staging). Accurate staging is crucial to ensuring that patients are directed to the most appropriate and effective treatment at different points on the clinical pathway. Establishing the comparative accuracy of ultrasound, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET)-CT imaging for detection of nodal or distant metastases, or both, is critical to understanding if, how, and where on the pathway these tests might be used. OBJECTIVES: Primary objectivesWe estimated accuracy separately according to the point in the clinical pathway at which imaging tests were used. Our objectives were:• to determine the diagnostic accuracy of ultrasound or PET-CT for detection of nodal metastases before sentinel lymph node biopsy in adults with confirmed cutaneous invasive melanoma; and• to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for whole body imaging in adults with cutaneous invasive melanoma:○ for detection of any metastasis in adults with a primary diagnosis of melanoma (i.e. primary staging at presentation); and○ for detection of any metastasis in adults undergoing staging of recurrence of melanoma (i.e. re-staging prompted by findings on routine follow-up).We undertook separate analyses according to whether accuracy data were reported per patient or per lesion.Secondary objectivesWe sought to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for whole body imaging (detection of any metastasis) in mixed or not clearly described populations of adults with cutaneous invasive melanoma.For study participants undergoing primary staging or re-staging (for possible recurrence), and for mixed or unclear populations, our objectives were:• to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for detection of nodal metastases;• to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for detection of distant metastases; and• to determine the diagnostic accuracy of ultrasound, CT, MRI, or PET-CT for detection of distant metastases according to metastatic site. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: We included studies of any design that evaluated ultrasound (with or without the use of fine needle aspiration cytology (FNAC)), CT, MRI, or PET-CT for staging of cutaneous melanoma in adults, compared with a reference standard of histological confirmation or imaging with clinical follow-up of at least three months' duration. We excluded studies reporting multiple applications of the same test in more than 10% of study participants. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2)). We estimated accuracy using the bivariate hierarchical method to produce summary sensitivities and specificities with 95% confidence and prediction regions. We undertook analysis of studies allowing direct and indirect comparison between tests. We examined heterogeneity between studies by visually inspecting the forest plots of sensitivity and specificity and summary receiver operating characteristic (ROC) plots. Numbers of identified studies were insufficient to allow formal investigation of potential sources of heterogeneity. MAIN RESULTS: We included a total of 39 publications reporting on 5204 study participants; 34 studies reporting data per patient included 4980 study participants with 1265 cases of metastatic disease, and seven studies reporting data per lesion included 417 study participants with 1846 potentially metastatic lesions, 1061 of which were confirmed metastases. The risk of bias was low or unclear for all domains apart from participant flow. Concerns regarding applicability of the evidence were high or unclear for almost all domains. Participant selection from mixed or not clearly defined populations and poorly described application and interpretation of index tests were particularly problematic.The accuracy of imaging for detection of regional nodal metastases before sentinel lymph node biopsy (SLNB) was evaluated in 18 studies. In 11 studies (2614 participants; 542 cases), the summary sensitivity of ultrasound alone was 35.4% (95% confidence interval (CI) 17.0% to 59.4%) and specificity was 93.9% (95% CI 86.1% to 97.5%). Combining pre-SLNB ultrasound with FNAC revealed summary sensitivity of 18.0% (95% CI 3.58% to 56.5%) and specificity of 99.8% (95% CI 99.1% to 99.9%) (1164 participants; 259 cases). Four studies demonstrated lower sensitivity (10.2%, 95% CI 4.31% to 22.3%) and specificity (96.5%,95% CI 87.1% to 99.1%) for PET-CT before SLNB (170 participants, 49 cases). When these data are translated to a hypothetical cohort of 1000 people eligible for SLNB, 237 of whom have nodal metastases (median prevalence), the combination of ultrasound with FNAC potentially allows 43 people with nodal metastases to be triaged directly to adjuvant therapy rather than having SLNB first, at a cost of two people with false positive results (who are incorrectly managed). Those with a false negative ultrasound will be identified on subsequent SLNB.Limited test accuracy data were available for whole body imaging via PET-CT for primary staging or re-staging for disease recurrence, and none evaluated MRI. Twenty-four studies evaluated whole body imaging. Six of these studies explored primary staging following a confirmed diagnosis of melanoma (492 participants), three evaluated re-staging of disease following some clinical indication of recurrence (589 participants), and 15 included mixed or not clearly described population groups comprising participants at a number of different points on the clinical pathway and at varying stages of disease (1265 participants). Results for whole body imaging could not be translated to a hypothetical cohort of people due to paucity of data.Most of the studies (6/9) of primary disease or re-staging of disease considered PET-CT, two in comparison to CT alone, and three studies examined the use of ultrasound. No eligible evaluations of MRI in these groups were identified. All studies used histological reference standards combined with follow-up, and two included FNAC for some participants. Observed accuracy for detection of any metastases for PET-CT was higher for re-staging of disease (summary sensitivity from two studies: 92.6%, 95% CI 85.3% to 96.4%; specificity: 89.7%, 95% CI 78.8% to 95.3%; 153 participants; 95 cases) compared to primary staging (sensitivities from individual studies ranged from 30% to 47% and specificities from 73% to 88%), and was more sensitive than CT alone in both population groups, but participant numbers were very small.No conclusions can be drawn regarding routine imaging of the brain via MRI or CT. AUTHORS' CONCLUSIONS: Review authors found a disappointing lack of evidence on the accuracy of imaging in people with a diagnosis of melanoma at different points on the clinical pathway. Studies were small and often reported data according to the number of lesions rather than the number of study participants. Imaging with ultrasound combined with FNAC before SLNB may identify around one-fifth of those with nodal disease, but confidence intervals are wide and further work is needed to establish cost-effectiveness. Much of the evidence for whole body imaging for primary staging or re-staging of disease is focused on PET-CT, and comparative data with CT or MRI are lacking. Future studies should go beyond diagnostic accuracy and consider the effects of different imaging tests on disease management. The increasing availability of adjuvant therapies for people with melanoma at high risk of disease spread at presentation will have a considerable impact on imaging services, yet evidence for the relative diagnostic accuracy of available tests is limited.


Assuntos
Melanoma/diagnóstico por imagem , Metástase Neoplásica , Estadiamento de Neoplasias , Neoplasias Cutâneas/diagnóstico por imagem , Adulto , Diagnóstico por Computador/métodos , Humanos , Imageamento por Ressonância Magnética , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Ensaios Clínicos Controlados Aleatórios como Assunto , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia , Melanoma Maligno Cutâneo
14.
Exp Dermatol ; 27(9): 989-992, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29791750

RESUMO

Filaggrin (FLG) loss-of-function (LOF) variants are a major risk factor for the common inflammatory skin disease, atopic dermatitis (AD) and are often population-specific. African-American (AA) children are disproportionately affected with AD, often later developing asthma and/or allergic rhinitis and comprise an atopy health disparity group for which the role of FLG LOF is not well known. Discovery of FLG LOF using exome sequencing is challenging given the known difficulties for accurate short-read alignment to FLG's high homology repeat variation. Here, we employed an array-based sequencing approach to tile across each FLG repeat and discover FLG LOF in a well-characterized cohort of AA children with moderate-to-severe AD. Five FLG LOF were identified in 23% of our cohort. Two novel FLG LOF singletons, c.488delG and p.S3101*, were discovered as well as p.R501*, p.R826* and p.S3316* previously reported for AD. p.S3316* (rs149484917) is likely an African ancestral FLG LOF, reported in African individuals in ExAC (Exome Aggregation Consortium), Exome Variant Server (ESP), and 4 African 1000G population databases (ESN, MSL, ASW, and ACB). The proportion of FLG LOF (11.5%) among the total FLG alleles in our cohort was significantly higher in comparisons with FLG LOF reported for African individuals in ExAC (2.5%; P = 4.3 × 10-4 ) and ESP (1.7%; P = 3.5 × 10-5 ) suggesting a disease-enrichment effect for FLG LOF. Our results demonstrate the utility of array-based sequencing in discovering FLG LOF, including novel and population-specific, which are of higher prevalence in our AA severe AD group than previously reported.


Assuntos
Negro ou Afro-Americano/genética , Dermatite Atópica/genética , Proteínas de Filamentos Intermediários/genética , Mutação com Perda de Função , Análise de Sequência de DNA/métodos , Adolescente , Alelos , Criança , Pré-Escolar , Exoma , Proteínas Filagrinas , Humanos , Lactente , Análise de Sequência com Séries de Oligonucleotídeos , Índice de Gravidade de Doença
15.
Cochrane Database Syst Rev ; 12: CD013190, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30521681

RESUMO

BACKGROUND: Melanoma has one of the fastest rising incidence rates of any cancer. It accounts for a small percentage of skin cancer cases but is responsible for the majority of skin cancer deaths. Early detection and treatment is key to improving survival; however, anxiety around missing early cases needs to be balanced against appropriate levels of referral and excision of benign lesions. Used in conjunction with clinical or dermoscopic suspicion of malignancy, or both, reflectance confocal microscopy (RCM) may reduce unnecessary excisions without missing melanoma cases. OBJECTIVES: To determine the diagnostic accuracy of reflectance confocal microscopy for the detection of cutaneous invasive melanoma and atypical intraepidermal melanocytic variants in adults with any lesion suspicious for melanoma and lesions that are difficult to diagnose, and to compare its accuracy with that of dermoscopy. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; and seven other databases. We studied reference lists and published systematic review articles. SELECTION CRITERIA: Studies of any design that evaluated RCM alone, or RCM in comparison to dermoscopy, in adults with lesions suspicious for melanoma or atypical intraepidermal melanocytic variants, compared with a reference standard of either histological confirmation or clinical follow-up. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). We contacted authors of included studies where information related to the target condition or diagnostic threshold were missing. We estimated summary sensitivities and specificities per algorithm and threshold using the bivariate hierarchical model. To compare RCM with dermoscopy, we grouped studies by population (defined by difficulty of lesion diagnosis) and combined data using hierarchical summary receiver operating characteristic (SROC) methods. Analysis of studies allowing direct comparison between tests was undertaken. To facilitate interpretation of results, we computed values of specificity at the point on the SROC curve with 90% sensitivity as this value lies within the estimates for the majority of analyses. We investigated the impact of using a purposely developed RCM algorithm and in-person test interpretation. MAIN RESULTS: The search identified 18 publications reporting on 19 study cohorts with 2838 lesions (including 658 with melanoma), which provided 67 datasets for RCM and seven for dermoscopy. Studies were generally at high or unclear risk of bias across almost all domains and of high or unclear concern regarding applicability of the evidence. Selective participant recruitment, lack of blinding of the reference test to the RCM result, and differential verification were particularly problematic. Studies may not be representative of populations eligible for RCM, and test interpretation was often undertaken remotely from the patient and blinded to clinical information.Meta-analysis found RCM to be more accurate than dermoscopy in studies of participants with any lesion suspicious for melanoma and in participants with lesions that were more difficult to diagnose (equivocal lesion populations). Assuming a fixed sensitivity of 90% for both tests, specificities were 82% for RCM and 42% for dermoscopy for any lesion suspicious for melanoma (9 RCM datasets; 1452 lesions and 370 melanomas). For a hypothetical population of 1000 lesions at the median observed melanoma prevalence of 30%, this equated to a reduction in unnecessary excisions with RCM of 280 compared to dermoscopy, with 30 melanomas missed by both tests. For studies in equivocal lesions, specificities of 86% would be observed for RCM and 49% for dermoscopy (7 RCM datasets; 1177 lesions and 180 melanomas). At the median observed melanoma prevalence of 20%, this reduced unnecessary excisions by 296 with RCM compared with dermoscopy, with 20 melanomas missed by both tests. Across all populations, algorithms and thresholds assessed, the sensitivity and specificity of the Pellacani RCM score at a threshold of three or greater were estimated at 92% (95% confidence interval (CI) 87 to 95) for RCM and 72% (95% CI 62 to 81) for dermoscopy. AUTHORS' CONCLUSIONS: RCM may have a potential role in clinical practice, particularly for the assessment of lesions that are difficult to diagnose using visual inspection and dermoscopy alone, where the evidence suggests that RCM may be both more sensitive and specific in comparison to dermoscopy. Given the paucity of data to allow comparison with dermoscopy, the results presented require further confirmation in prospective studies comparing RCM with dermoscopy in a real-world setting in a representative population.


Assuntos
Dermoscopia , Melanoma/diagnóstico por imagem , Microscopia Confocal/métodos , Neoplasias Cutâneas/diagnóstico por imagem , Adulto , Biópsia , Humanos , Melanoma/patologia , Sensibilidade e Especificidade , Pele/patologia , Neoplasias Cutâneas/patologia , Melanoma Maligno Cutâneo
16.
Cochrane Database Syst Rev ; 12: CD013188, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30521683

RESUMO

BACKGROUND: Early, accurate detection of all skin cancer types is essential to guide appropriate management and to improve morbidity and survival. Melanoma and squamous cell carcinoma (SCC) are high-risk skin cancers with the potential to metastasise and ultimately lead to death, whereas basal cell carcinoma (BCC) is usually localised, with potential to infiltrate and damage surrounding tissue. Anxiety around missing early curable cases needs to be balanced against inappropriate referral and unnecessary excision of benign lesions. Ultrasound is a non-invasive imaging technique that relies on the measurement of sound wave reflections from the tissues of the body. At lower frequencies, the deeper structures of the body such as the internal organs can be visualised, while high-frequency ultrasound (HFUS) with transducer frequencies of 20 MHz or more has a much lower depth of tissue penetration but produces a higher resolution image of tissues and structures closer to the skin surface. Used in conjunction with clinical and/or dermoscopic examination of suspected skin cancer, HFUS may offer additional diagnostic information compared to other technologies. OBJECTIVES: To assess the diagnostic accuracy of HFUS to assist in the diagnosis of a) cutaneous invasive melanoma and atypical intraepidermal melanocytic variants, b) cutaneous squamous cell carcinoma (cSCC), and c) basal cell carcinoma (BCC) in adults. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: Studies evaluating HFUS (20 MHz or more) in adults with lesions suspicious for melanoma, cSCC or BCC versus a reference standard of histological confirmation or clinical follow-up. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). Due to scarcity of data and the poor quality of studies, we did not undertake a meta-analysis for this review. For illustrative purposes, we plot estimates of sensitivity and specificity on coupled forest plots. MAIN RESULTS: We included six studies, providing 29 datasets: 20 for diagnosis of melanoma (1125 lesions and 242 melanomas) and 9 for diagnosis of BCC (993 lesions and 119 BCCs). We did not identify any data relating to the diagnosis of cSCC.Studies were generally poorly reported, limiting judgements of methodological quality. Half the studies did not set out to establish test accuracy, and all should be considered preliminary evaluations of the potential usefulness of HFUS. There were particularly high concerns for applicability of findings due to selective study populations and data-driven thresholds for test positivity. Studies reporting qualitative assessments of HFUS images excluded up to 22% of lesions (including some melanomas) due to lack of visualisation in the test.Derived sensitivities for qualitative HFUS characteristics were at least 83% (95% CI 75% to 90%) for the detection of melanoma; the combination of three features (lesions appearing hypoechoic, homogenous and well defined) demonstrating 100% sensitivity in two studies (lower limits of the 95% CIs were 94% and 82%), with variable corresponding specificities of 33% (95% CI 20% to 48%) and 73% (95% CI 57% to 85%), respectively. Quantitative measurement of HFUS outputs in two studies enabled decision thresholds to be set to achieve 100% sensitivity; specificities were 93% (95% CI 77% to 99%) and 65% (95% CI 51% to 76%). It was not possible to make summary statements regarding HFUS accuracy for the diagnosis of BCC due to highly variable sensitivities and specificities. AUTHORS' CONCLUSIONS: Insufficient data are available on the potential value of HFUS in the diagnosis of melanoma or BCC. Given the between-study heterogeneity, unclear to low methodological quality and limited volume of evidence, we cannot draw any implications for practice. The main value of the preliminary studies included may be in providing guidance on the possible components of new diagnostic rules for diagnosis of melanoma or BCC using HFUS that will require future evaluation. A prospective evaluation of HFUS added to visual inspection and dermoscopy alone in a standard healthcare setting, with a clearly defined and representative population of participants, would be required for a full and proper evaluation of accuracy.


Assuntos
Carcinoma Basocelular/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Melanoma/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Humanos , Sensibilidade e Especificidade , Melanoma Maligno Cutâneo
17.
Cochrane Database Syst Rev ; 12: CD013191, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30521687

RESUMO

BACKGROUND: Early accurate detection of all skin cancer types is important to guide appropriate management and improve morbidity and survival. Basal cell carcinoma (BCC) is usually a localised skin cancer but with potential to infiltrate and damage surrounding tissue, whereas cutaneous squamous cell carcinoma (cSCC) and melanoma are higher risk skin cancers with the potential to metastasise and ultimately lead to death. When used in conjunction with clinical or dermoscopic suspicion of malignancy, or both, reflectance confocal microscopy (RCM) may help to identify cancers eligible for non-surgical treatment without the need for a diagnostic biopsy, particularly in people with suspected BCC. Any potential benefit must be balanced against the risk of any misdiagnoses. OBJECTIVES: To determine the diagnostic accuracy of RCM for the detection of BCC, cSCC, or any skin cancer in adults with any suspicious lesion and lesions that are difficult to diagnose (equivocal); and to compare its accuracy with that of usual practice (visual inspection or dermoscopy, or both). SEARCH METHODS: We undertook a comprehensive search of the following databases from inception to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists and published systematic review articles. SELECTION CRITERIA: Studies of any design that evaluated the accuracy of RCM alone, or RCM in comparison to visual inspection or dermoscopy, or both, in adults with lesions suspicious for skin cancer compared with a reference standard of either histological confirmation or clinical follow-up, or both. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data using a standardised data extraction and quality assessment form (based on QUADAS-2). We contacted authors of included studies where information related to the target condition or diagnostic threshold were missing. We estimated summary sensitivities and specificities using the bivariate hierarchical model. For computation of likely numbers of true-positive, false-positive, false-negative, and true-negative findings in the 'Summary of findings' tables, we applied summary sensitivity and specificity estimates to lower quartile, median and upper quartiles of the prevalence observed in the study groups. We also investigated the impact of observer experience. MAIN RESULTS: The review included 10 studies reporting on 11 study cohorts. All 11 cohorts reported data for the detection of BCC, including 2037 lesions (464 with BCC); and four cohorts reported data for the detection of cSCC, including 834 lesions (71 with cSCC). Only one study also reported data for the detection of BCC or cSCC using dermoscopy, limiting comparisons between RCM and dermoscopy. Studies were at high or unclear risk of bias across almost all methodological quality domains, and were of high or unclear concern regarding applicability of the evidence. Selective participant recruitment, unclear blinding of the reference test, and exclusions due to image quality or technical difficulties were observed. It was unclear whether studies were representative of populations eligible for testing with RCM, and test interpretation was often undertaken using images, remotely from the participant and the interpreter blinded to clinical information that would normally be available in practice.Meta-analysis found RCM to be more sensitive but less specific for the detection of BCC in studies of participants with equivocal lesions (sensitivity 94%, 95% confidence interval (CI) 79% to 98%; specificity 85%, 95% CI 72% to 92%; 3 studies) compared to studies that included any suspicious lesion (sensitivity 76%, 95% CI 45% to 92%; specificity 95%, 95% CI 66% to 99%; 4 studies), although CIs were wide. At the median prevalence of disease of 12.5% observed in studies including any suspicious lesion, applying these results to a hypothetical population of 1000 lesions results in 30 BCCs missed with 44 false-positive results (lesions misdiagnosed as BCCs). At the median prevalence of disease of 15% observed in studies of equivocal lesions, nine BCCs would be missed with 128 false-positive results in a population of 1000 lesions. Across both sets of studies, up to 15% of these false-positive lesions were observed to be melanomas mistaken for BCCs. There was some suggestion of higher sensitivities in studies with more experienced observers. Summary sensitivity and specificity could not be estimated for the detection of cSCC due to paucity of data. AUTHORS' CONCLUSIONS: There is insufficient evidence for the use of RCM for the diagnosis of BCC or cSCC in either population group. A possible role for RCM in clinical practice is as a tool to avoid diagnostic biopsies in lesions with a relatively high clinical suspicion of BCC. The potential for, and consequences of, misclassification of other skin cancers such as melanoma as BCCs requires further research. Importantly, data are lacking that compare RCM to standard clinical practice (with or without dermoscopy).


Assuntos
Carcinoma Basocelular/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Microscopia Confocal/métodos , Neoplasias Cutâneas/diagnóstico por imagem , Adulto , Dermoscopia , Reações Falso-Positivas , Humanos , Exame Físico/métodos , Sensibilidade e Especificidade
18.
Cochrane Database Syst Rev ; 12: CD013187, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30521689

RESUMO

BACKGROUND: Early accurate detection of all skin cancer types is essential to guide appropriate management, reduce morbidity and improve survival. Basal cell carcinoma (BCC) is usually localised to the skin but has potential to infiltrate and damage surrounding tissue, while cutaneous squamous cell carcinoma (cSCC) and melanoma have a much higher potential to metastasise and ultimately lead to death. Exfoliative cytology is a non-invasive test that uses the Tzanck smear technique to identify disease by examining the structure of cells obtained from scraped samples. This simple procedure is a less invasive diagnostic test than a skin biopsy, and for BCC it has the potential to provide an immediate diagnosis that avoids an additional clinic visit to receive skin biopsy results. This may benefit patients scheduled for either Mohs micrographic surgery or non-surgical treatments such as radiotherapy. A cytology scrape can never give the same information as a skin biopsy, however, so it is important to better understand in which skin cancer situations it may be helpful. OBJECTIVES: To determine the diagnostic accuracy of exfoliative cytology for detecting basal cell carcinoma (BCC) in adults, and to compare its accuracy with that of standard diagnostic practice (visual inspection with or without dermoscopy). Secondary objectives were: to determine the diagnostic accuracy of exfoliative cytology for detecting cSCC, invasive melanoma and atypical intraepidermal melanocytic variants, and any other skin cancer; and for each of these secondary conditions to compare the accuracy of exfoliative cytology with visual inspection with or without dermoscopy in direct test comparisons; and to determine the effect of observer experience. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We also studied the reference lists of published systematic review articles. SELECTION CRITERIA: Studies evaluating exfoliative cytology in adults with lesions suspicious for BCC, cSCC or melanoma, compared with a reference standard of histological confirmation. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). Where possible we estimated summary sensitivities and specificities using the bivariate hierarchical model. MAIN RESULTS: We synthesised the results of nine studies contributing a total of 1655 lesions to our analysis, including 1120 BCCs (14 datasets), 41 cSCCs (amongst 401 lesions in 2 datasets), and 10 melanomas (amongst 200 lesions in 1 dataset). Three of these datasets (one each for BCC, melanoma and any malignant condition) were derived from one study that also performed a direct comparison with dermoscopy. Studies were of moderate to poor quality, providing inadequate descriptions of participant selection, thresholds used to make cytological and histological diagnoses, and blinding. Reporting of participants' prior referral pathways was particularly poor, as were descriptions of the cytodiagnostic criteria used to make diagnoses. No studies evaluated the use of exfoliative cytology as a primary diagnostic test for detecting BCC or other skin cancers in lesions suspicious for skin cancer. Pooled data from seven studies using standard cytomorphological criteria (but various stain methods) to detect BCC in participants with a high clinical suspicion of BCC estimated the sensitivity and specificity of exfoliative cytology as 97.5% (95% CI 94.5% to 98.9%) and 90.1% (95% CI 81.1% to 95.1%). respectively. When applied to a hypothetical population of 1000 clinically suspected BCC lesions with a median observed BCC prevalence of 86%, exfoliative cytology would miss 21 BCCs and would lead to 14 false positive diagnoses of BCC. No false positive cases were histologically confirmed to be melanoma. Insufficient data are available to make summary statements regarding the accuracy of exfoliative cytology to detect melanoma or cSCC, or its accuracy compared to dermoscopy. AUTHORS' CONCLUSIONS: The utility of exfoliative cytology for the primary diagnosis of skin cancer is unknown, as all included studies focused on the use of this technique for confirming strongly suspected clinical diagnoses. For the confirmation of BCC in lesions with a high clinical suspicion, there is evidence of high sensitivity and specificity. Since decisions to treat low-risk BCCs are unlikely in practice to require diagnostic confirmation given that clinical suspicion is already high, exfoliative cytology might be most useful for cases of BCC where the treatments being contemplated require a tissue diagnosis (e.g. radiotherapy). The small number of included studies, poor reporting and varying methodological quality prevent us from drawing strong conclusions to guide clinical practice. Despite insufficient data on the use of cytology for cSCC or melanoma, it is unlikely that cytology would be useful in these scenarios since preservation of the architecture of the whole lesion that would be available from a biopsy provides crucial diagnostic information. Given the paucity of good quality data, appropriately designed prospective comparative studies may be required to evaluate both the diagnostic value of exfoliative cytology by comparison to dermoscopy, and its confirmatory value in adequately reported populations with a high probability of BCC scheduled for further treatment requiring a tissue diagnosis.


Assuntos
Carcinoma Basocelular/patologia , Carcinoma de Células Escamosas/patologia , Citodiagnóstico/métodos , Melanoma/patologia , Neoplasias Cutâneas/patologia , Adulto , Corantes Azur , Carcinoma Basocelular/diagnóstico , Carcinoma de Células Escamosas/diagnóstico , Corantes , Dermoscopia , Humanos , Teste de Papanicolaou , Sensibilidade e Especificidade , Neoplasias Cutâneas/diagnóstico , Melanoma Maligno Cutâneo
19.
Cochrane Database Syst Rev ; 12: CD011902, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30521682

RESUMO

BACKGROUND: Melanoma has one of the fastest rising incidence rates of any cancer. It accounts for a small percentage of skin cancer cases but is responsible for the majority of skin cancer deaths. Although history-taking and visual inspection of a suspicious lesion by a clinician are usually the first in a series of 'tests' to diagnose skin cancer, dermoscopy has become an important tool to assist diagnosis by specialist clinicians and is increasingly used in primary care settings. Dermoscopy is a magnification technique using visible light that allows more detailed examination of the skin compared to examination by the naked eye alone. Establishing the additive value of dermoscopy over and above visual inspection alone across a range of observers and settings is critical to understanding its contribution for the diagnosis of melanoma and to future understanding of the potential role of the growing number of other high-resolution image analysis techniques. OBJECTIVES: To determine the diagnostic accuracy of dermoscopy alone, or when added to visual inspection of a skin lesion, for the detection of cutaneous invasive melanoma and atypical intraepidermal melanocytic variants in adults. We separated studies according to whether the diagnosis was recorded face-to-face (in-person), or based on remote (image-based), assessment. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception up to August 2016: CENTRAL; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists and published systematic review articles. SELECTION CRITERIA: Studies of any design that evaluated dermoscopy in adults with lesions suspicious for melanoma, compared with a reference standard of either histological confirmation or clinical follow-up. Data on the accuracy of visual inspection, to allow comparisons of tests, was included only if reported in the included studies of dermoscopy. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). We contacted authors of included studies where information related to the target condition or diagnostic threshold were missing. We estimated accuracy using hierarchical summary receiver operating characteristic (SROC),methods. Analysis of studies allowing direct comparison between tests was undertaken. To facilitate interpretation of results, we computed values of sensitivity at the point on the SROC curve with 80% fixed specificity and values of specificity with 80% fixed sensitivity. We investigated the impact of in-person test interpretation; use of a purposely developed algorithm to assist diagnosis; observer expertise; and dermoscopy training. MAIN RESULTS: We included a total of 104 study publications reporting on 103 study cohorts with 42,788 lesions (including 5700 cases), providing 354 datasets for dermoscopy. The risk of bias was mainly low for the index test and reference standard domains and mainly high or unclear for participant selection and participant flow. Concerns regarding the applicability of study findings were largely scored as 'high' concern in three of four domains assessed. Selective participant recruitment, lack of reproducibility of diagnostic thresholds and lack of detail on observer expertise were particularly problematic.The accuracy of dermoscopy for the detection of invasive melanoma or atypical intraepidermal melanocytic variants was reported in 86 datasets; 26 for evaluations conducted in person (dermoscopy added to visual inspection), and 60 for image-based evaluations (diagnosis based on interpretation of dermoscopic images). Analyses of studies by prior testing revealed no obvious effect on accuracy; analyses were hampered by the lack of studies in primary care, lack of relevant information and the restricted inclusion of lesions selected for biopsy or excision. Accuracy was higher for in-person diagnosis compared to image-based evaluations (relative diagnostic odds ratio (RDOR) 4.6, 95% confidence interval (CI) 2.4 to 9.0; P < 0.001).We compared accuracy for (a), in-person evaluations of dermoscopy (26 evaluations; 23,169 lesions and 1664 melanomas),versus visual inspection alone (13 evaluations; 6740 lesions and 459 melanomas), and for (b), image-based evaluations of dermoscopy (60 evaluations; 13,475 lesions and 2851 melanomas),versus image-based visual inspection (11 evaluations; 1740 lesions and 305 melanomas). For both comparisons, meta-analysis found dermoscopy to be more accurate than visual inspection alone, with RDORs of (a), 4.7 (95% CI 3.0 to 7.5; P < 0.001), and (b), 5.6 (95% CI 3.7 to 8.5; P < 0.001). For a), the predicted difference in sensitivity at a fixed specificity of 80% was 16% (95% CI 8% to 23%; 92% for dermoscopy + visual inspection versus 76% for visual inspection), and predicted difference in specificity at a fixed sensitivity of 80% was 20% (95% CI 7% to 33%; 95% for dermoscopy + visual inspection versus 75% for visual inspection). For b) the predicted differences in sensitivity was 34% (95% CI 24% to 46%; 81% for dermoscopy versus 47% for visual inspection), at a fixed specificity of 80%, and predicted difference in specificity was 40% (95% CI 27% to 57%; 82% for dermoscopy versus 42% for visual inspection), at a fixed sensitivity of 80%.Using the median prevalence of disease in each set of studies ((a), 12% for in-person and (b), 24% for image-based), for a hypothetical population of 1000 lesions, an increase in sensitivity of (a), 16% (in-person), and (b), 34% (image-based), from using dermoscopy at a fixed specificity of 80% equates to a reduction in the number of melanomas missed of (a), 19 and (b), 81 with (a), 176 and (b), 152 false positive results. An increase in specificity of (a), 20% (in-person), and (b), 40% (image-based), at a fixed sensitivity of 80% equates to a reduction in the number of unnecessary excisions from using dermoscopy of (a), 176 and (b), 304 with (a), 24 and (b), 48 melanomas missed.The use of a named or published algorithm to assist dermoscopy interpretation (as opposed to no reported algorithm or reported use of pattern analysis), had no significant impact on accuracy either for in-person (RDOR 1.4, 95% CI 0.34 to 5.6; P = 0.17), or image-based (RDOR 1.4, 95% CI 0.60 to 3.3; P = 0.22), evaluations. This result was supported by subgroup analysis according to algorithm used. We observed higher accuracy for observers reported as having high experience and for those classed as 'expert consultants' in comparison to those considered to have less experience in dermoscopy, particularly for image-based evaluations. Evidence for the effect of dermoscopy training on test accuracy was very limited but suggested associated improvements in sensitivity. AUTHORS' CONCLUSIONS: Despite the observed limitations in the evidence base, dermoscopy is a valuable tool to support the visual inspection of a suspicious skin lesion for the detection of melanoma and atypical intraepidermal melanocytic variants, particularly in referred populations and in the hands of experienced users. Data to support its use in primary care are limited, however, it may assist in triaging suspicious lesions for urgent referral when employed by suitably trained clinicians. Formal algorithms may be of most use for dermoscopy training purposes and for less expert observers, however reliable data comparing approaches using dermoscopy in person are lacking.


Assuntos
Dermoscopia , Melanoma/diagnóstico , Exame Físico/métodos , Neoplasias Cutâneas/diagnóstico , Adulto , Algoritmos , Biópsia , Humanos , Melanoma/diagnóstico por imagem , Melanoma/patologia , Sensibilidade e Especificidade , Pele/patologia , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/patologia , Melanoma Maligno Cutâneo
20.
Cochrane Database Syst Rev ; 12: CD013192, 2018 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-30521685

RESUMO

BACKGROUND: Melanoma accounts for a small proportion of all skin cancer cases but is responsible for most skin cancer-related deaths. Early detection and treatment can improve survival. Smartphone applications are readily accessible and potentially offer an instant risk assessment of the likelihood of malignancy so that the right people seek further medical attention from a clinician for more detailed assessment of the lesion. There is, however, a risk that melanomas will be missed and treatment delayed if the application reassures the user that their lesion is low risk. OBJECTIVES: To assess the diagnostic accuracy of smartphone applications to rule out cutaneous invasive melanoma and atypical intraepidermal melanocytic variants in adults with concerns about suspicious skin lesions. SEARCH METHODS: We undertook a comprehensive search of the following databases from inception to August 2016: Cochrane Central Register of Controlled Trials; MEDLINE; Embase; CINAHL; CPCI; Zetoc; Science Citation Index; US National Institutes of Health Ongoing Trials Register; NIHR Clinical Research Network Portfolio Database; and the World Health Organization International Clinical Trials Registry Platform. We studied reference lists and published systematic review articles. SELECTION CRITERIA: Studies of any design evaluating smartphone applications intended for use by individuals in a community setting who have lesions that might be suspicious for melanoma or atypical intraepidermal melanocytic variants versus a reference standard of histological confirmation or clinical follow-up and expert opinion. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted all data using a standardised data extraction and quality assessment form (based on QUADAS-2). Due to scarcity of data and poor quality of studies, we did not perform a meta-analysis for this review. For illustrative purposes, we plotted estimates of sensitivity and specificity on coupled forest plots for each application under consideration. MAIN RESULTS: This review reports on two cohorts of lesions published in two studies. Both studies were at high risk of bias from selective participant recruitment and high rates of non-evaluable images. Concerns about applicability of findings were high due to inclusion only of lesions already selected for excision in a dermatology clinic setting, and image acquisition by clinicians rather than by smartphone app users.We report data for five mobile phone applications and 332 suspicious skin lesions with 86 melanomas across the two studies. Across the four artificial intelligence-based applications that classified lesion images (photographs) as melanomas (one application) or as high risk or 'problematic' lesions (three applications) using a pre-programmed algorithm, sensitivities ranged from 7% (95% CI 2% to 16%) to 73% (95% CI 52% to 88%) and specificities from 37% (95% CI 29% to 46%) to 94% (95% CI 87% to 97%). The single application using store-and-forward review of lesion images by a dermatologist had a sensitivity of 98% (95% CI 90% to 100%) and specificity of 30% (95% CI 22% to 40%).The number of test failures (lesion images analysed by the applications but classed as 'unevaluable' and excluded by the study authors) ranged from 3 to 31 (or 2% to 18% of lesions analysed). The store-and-forward application had one of the highest rates of test failure (15%). At least one melanoma was classed as unevaluable in three of the four application evaluations. AUTHORS' CONCLUSIONS: Smartphone applications using artificial intelligence-based analysis have not yet demonstrated sufficient promise in terms of accuracy, and they are associated with a high likelihood of missing melanomas. Applications based on store-and-forward images could have a potential role in the timely presentation of people with potentially malignant lesions by facilitating active self-management health practices and early engagement of those with suspicious skin lesions; however, they may incur a significant increase in resource and workload. Given the paucity of evidence and low methodological quality of existing studies, it is not possible to draw any implications for practice. Nevertheless, this is a rapidly advancing field, and new and better applications with robust reporting of studies could change these conclusions substantially.


Assuntos
Detecção Precoce de Câncer/métodos , Melanoma/diagnóstico por imagem , Aplicativos Móveis , Neoplasias Cutâneas/diagnóstico por imagem , Smartphone , Triagem/métodos , Adulto , Algoritmos , Erros de Diagnóstico/estatística & dados numéricos , Detecção Precoce de Câncer/instrumentação , Humanos , Sensibilidade e Especificidade , Melanoma Maligno Cutâneo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA