1.
J Clin Microbiol ; 56(8)2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29875193

RESUMO

The accuracy and robustness of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) system was evaluated by identifying mycobacteria from automated liquid-medium systems using patient samples. This is the first report to demonstrate that proteins within the liquid medium, its supplements, and decontamination reagents for nonsterile patient samples do not generate misidentification or false-positive results by use of the Vitek MS v3.0 system. Prior to testing with patient samples, a seeded-culture study was conducted to challenge the accuracy of the Vitek MS system at identifying mycobacteria from liquid medium by mimicking a clinical workflow. Seventy-seven Mycobacterium strains representing 21 species, seeded in simulated sputum, were decontaminated, inoculated into BacT/Alert MP liquid culture medium, incubated until positivity, and identified using the Vitek MS system. A total of 383 liquid cultures were tested, of which 379 (99%) were identified correctly to the species/complex/group level, 4 (1%) gave a "no-identification" result, and no misidentifications were observed. Following the simulated-sputum study, a total of 73 smear-positive liquid-medium cultures detected using BD BBL MGIT and VersaTREK Myco liquid media were identified by the Vitek MS system. Sixty-four cultures (87.7%) were correctly identified to the species/complex/group level; 7 (9.6%) resulted in no identification; and 2 (2.7%) were misidentified at the species level. These results indicate that the Vitek MS v3.0 system is an accurate tool for routine diagnostics of Mycobacterium species isolated from liquid cultures.


Assuntos
Técnicas Bacteriológicas/métodos , Infecções por Mycobacterium não Tuberculosas/diagnóstico , Mycobacterium/classificação , Mycobacterium/isolamento & purificação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Técnicas Bacteriológicas/instrumentação , Meios de Cultura , Testes Diagnósticos de Rotina , Humanos , Mycobacterium/química , Escarro/microbiologia
2.
J Clin Microbiol ; 56(6)2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29643203

RESUMO

This multicenter study was designed to assess the accuracy and reproducibility of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry system for identification of Mycobacterium and Nocardia species compared to DNA sequencing. A total of 963 clinical isolates representing 51 taxa were evaluated. In all, 663 isolates were correctly identified to the species level (69%), with another 231 (24%) correctly identified to the complex or group level. Fifty-five isolates (6%) could not be identified despite repeat testing. All of the tuberculous mycobacteria (45/45; 100%) and most of the nontuberculous mycobacteria (569/606; 94%) were correctly identified at least to the group or complex level. However, not all species or subspecies within the M. tuberculosis, M. abscessus, and M. avium complexes and within the M. fortuitum and M. mucogenicum groups could be differentiated. Among the 312 Nocardia isolates tested, 236 (76%) were correctly identified to the species level, with an additional 44 (14%) correctly identified to the complex level. Species within the N. nova and N. transvalensis complexes could not always be differentiated. Eleven percent of the isolates (103/963) underwent repeat testing in order to get a final result. Identification of a representative set of Mycobacterium and Nocardia species was highly reproducible, with 297 of 300 (99%) replicates correctly identified using multiple kit lots, instruments, analysts, and sites. These findings demonstrate that the system is robust and has utility for the routine identification of mycobacteria and Nocardia in clinical practice.


Assuntos
Mycobacterium tuberculosis/isolamento & purificação , Nocardia/isolamento & purificação , Micobactérias não Tuberculosas/isolamento & purificação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Mycobacterium tuberculosis/genética , Nocardia/genética , Nocardiose/diagnóstico , Nocardiose/microbiologia , RNA Ribossômico 16S/genética , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Tuberculose/diagnóstico , Tuberculose/microbiologia
3.
Infect Control Hosp Epidemiol ; 34(6): 625-30, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23651895

RESUMO

On June 13, 2012, a group of key stakeholders, leaders, and national experts on tuberculosis (TB), occupational health, and laboratory science met in Atlanta, Georgia, to focus national discussion on the higher than expected positive results occurring among low-risk, unexposed healthcare workers undergoing serial testing with interferon-γ release assays (IGRAs). The objectives of the meeting were to present the latest clinical and operational research findings on the topic, to discuss evaluation and treatment algorithms that are emerging in the absence of national guidance, and to develop a consensus on the action steps needed to assist programs and physicians in the interpretation of serial testing IGRA results. This report summarizes its proceedings.


Assuntos
Testes de Liberação de Interferon-gama/normas , Saúde Ocupacional , Guias de Prática Clínica como Assunto , Tuberculose/diagnóstico , Setor de Assistência à Saúde , Humanos , Curva ROC , Tuberculose/tratamento farmacológico , Tuberculose/prevenção & controle , Estados Unidos