Nucl Med Commun ; 42(1): 107-112, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33079892

RESUMO

OBJECTIVES: CARE Dose 4D modulates mAs through several mechanisms according to patient size and shape, whilst maintaining user-defined reference image quality on Siemens Symbia single-photon emission computed tomography (SPECT)-computed tomography (CT) systems. A 20 kg child reference was used in child protocols prior to software version VB10 and a 75 kg adult thereafter. Quality reference mAs conversion factors are estimated for delivering equivalent mAs to children between two comparable SPECT-CT systems using adult and child references for topogram-based patient-size-related dose level adaptations. METHODS: A child phantom was scanned using child protocols on a Siemens Symbia T16 (child reference) and a Siemens Symbia Intevo Bold (adult reference). On each system, scans of the thorax, abdomen and pelvis were acquired with arms up and down, at 80 and 110 kVp. Quality reference mAs settings of 10-50 were used on the Symbia T16 and 40-200 on the Symbia Intevo Bold. These data were used to propose quality reference mAs (adult/child reference) conversion factors according to scan range, arm position and tube voltage. RESULTS: Quality reference mAs for child protocols using the adult reference should multiply the child quality reference mAs by the following factors, to give comparable delivered mAs: arms up 80 kV: 3.8 (thorax), 3.8 (abdomen), 4.3 (pelvis); arms up at 110 kV: 3.8 (thorax), 4.1 (abdomen), 4.6 (pelvis); arms down at 80 kV: 4.0 (thorax), 3.7 (abdomen), 3.9 (pelvis); arms down at 110 kV: 4.3 (thorax), 4.0 (abdomen), 4.2 (pelvis). CONCLUSION: Conversion factors for child to adult dose modulation references are proposed, allowing comparable delivered mAs to a child.Video abstract: http://links.lww.com/NMC/A178.


Assuntos
Imagens de Fantasmas , Radiometria/instrumentação , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Controle de Qualidade , Padrões de Referência
2.
EJNMMI Phys ; 8(1): 29, 2021 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-33743091

RESUMO

BACKGROUND: Applied tube voltage (kilovolts, kV) and tube current (milliampere seconds, mAs) affect CT radiation dose and image quality and should be optimised for the individual patient. CARE kV determines the kV and mAs providing the lowest dose to the patient, whilst maintaining user-defined reference image quality. Given that kV changes affect CT values which are used to obtain attenuation maps, the aim was to evaluate the effect of kV changes on PET quantification and CT radiation dose using phantoms. METHOD: Four phantoms ('Lungman', 'Lungman plus fat', 'Esser' and 'NEMA image quality' (NEMA IQ)) containing F-18 sources underwent 1 PET and 5 CT scans, with CARE kV on (automatic kV selection and mAs modulation) and in semi mode with specified tube voltages of 140, 120, 100 and 80 kV (mAs modulation only). A CARE kV image quality reference of 120 kV/50 mAs was used. Impact on PET quantification was determined by comparing measured activity concentrations for PET reconstructions from different CT scans with the reconstruction using the 120 kV reference, and dose (DLP, CTDIvol) differences calculated by comparing doses from all kV settings with the 120 kV reference. RESULTS: CARE kV-determined optimal tube voltage and CARE kV 'on' dose (DLP) savings compared with the 120 kV reference were: Lungman, 100 kV, 2.0%; Lungman plus fat, 120 kV, 0%; Esser, 100 kV, 9.3%; NEMA IQ, 100 kV, 3.4%. Using tube voltages in CARE kV 'semi' mode which were not advised by CARE kV 'on' resulted in dose increases ≤ 65% compared with the 120 kV reference (greatest difference Lungman plus fat, 80 kV). Clinically insignificant differences in PET activity quantification of up to 0.7% (Lungman, 100 kV, mean measured activity concentration) were observed when using the optimal tube voltage advised by CARE kV. Differences in PET quantification of up to 4.0% (Lungman, 140 kV, maximum measured activity concentration) were found over the full selection of tube voltages in semi mode, with the greatest differences seen at the most suboptimal kV for each phantom. However, most differences were within 1%. CONCLUSIONS: CARE kV on can provide CT radiation dose savings without concern over changes in PET quantification.

3.
EJNMMI Phys ; 6(1): 24, 2019 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-31845047

RESUMO

BACKGROUND: Computed tomography (CT) scans are routinely performed in positron emission tomography (PET) and single photon emission computed tomography (SPECT) examinations globally, yet few surveys have been conducted to gather national diagnostic reference level (NDRL) data for CT radiation doses in positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT). In this first Nordic-wide study of CT doses in hybrid imaging, Nordic NDRL CT doses are suggested for PET/CT and SPECT/CT examinations specific to the clinical purpose of CT, and the scope for optimisation is evaluated. Data on hybrid imaging CT exposures and clinical purpose of CT were gathered for 5 PET/CT and 8 SPECT/CT examinations via designed booklet. For each included dataset for a given facility and scanner type, the computed tomography dose index by volume (CTDIvol) and dose length product (DLP) was interpolated for a 75-kg person (referred to as CTDIvol,75kg and DLP75kg). Suggested NDRL (75th percentile) and achievable doses (50th percentile) were determined for CTDIvol,75kg and DLP75kg according to clinical purpose of CT. Differences in maximum and minimum doses (derived for a 75-kg patient) between facilities were also calculated for each examination and clinical purpose. RESULTS: Data were processed from 83 scanners from 43 facilities. Data were sufficient to suggest Nordic NDRL CT doses for the following: PET/CT oncology (localisation/characterisation, 15 systems); infection/inflammation (localisation/characterisation, 13 systems); brain (attenuation correction (AC) only, 11 systems); cardiac PET/CT and SPECT/CT (AC only, 30 systems); SPECT/CT lung (localisation/characterisation, 12 systems); bone (localisation/characterisation, 30 systems); and parathyroid (localisation/characterisation, 13 systems). Great variations in dose were seen for all aforementioned examinations. Greatest differences in DLP75kg for each examination, specific to clinical purpose, were as follows: SPECT/CT lung AC only (27.4); PET/CT and SPECT/CT cardiac AC only (19.6); infection/inflammation AC only (18.1); PET/CT brain localisation/characterisation (16.8); SPECT/CT bone localisation/characterisation (10.0); PET/CT oncology AC only (9.0); and SPECT/CT parathyroid localisation/characterisation (7.8). CONCLUSIONS: Suggested Nordic NDRL CT doses are presented according to clinical purpose of CT for PET/CT oncology, infection/inflammation, brain, PET/CT and SPECT/CT cardiac, and SPECT/CT lung, bone, and parathyroid. The large variation in doses suggests great scope for optimisation in all 8 examinations.

4.
Nucl Med Commun ; 38(6): 459-470, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28452797

RESUMO

OBJECTIVES: The aim of this study was to conduct a nationwide survey of computed tomography (CT) doses for a wide range of PET-CT and single photon emission computed tomography-computed tomography (SPECT-CT) imaging procedures, with the aim of generating proposed UK national diagnostic reference levels (NDRLs). METHODS: CT protocol and dosimetry data for three PET-CT and seven SPECT-CT examinations were gathered from centres across the UK. Data were divided according to CT purpose (attenuation correction, localization or diagnostic) and third quartile values of scanner average dose metrics were used to generate suggested NDRLs for a range of examination and CT purpose combinations. Achievable doses were also established from the median of the dose distributions. RESULTS: Data were obtained from 47 centres, allowing suggested NDRLs to be produced for fluorine-18-fluorodeoxyglucose half-body PET-CT, and parathyroid, post-thyroid ablation, meta-iodobenzylguanidine/octreotide, cardiac and bone SPECT-CT examinations.Variations in dose of up to a factor of 35 were observed for a given examination/CT purpose combination. For fluorine-18-fluorodeoxyglucose half-body PET-CT examination dose levels for the three CT purposes overlapped, which highlights the variability in the way in which CT purposes are interpreted across the UK. This lack of standardization is believed to be the largest contributor to the dose variations that were observed. The survey highlighted the need for targeted optimization work in many centres. CONCLUSION: Suggested UK NDRLs and achievable doses for six common PET-CT and SPECT-CT examinations have been established as a result of this study.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Doses de Radiação , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Inquéritos e Questionários , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Padrões de Referência , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Reino Unido
5.
J Bone Miner Res ; 32(1): 172-180, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27490028

RESUMO

The increasing use of dual-energy X-ray absorptiometry (DXA) in children has led to the need for robust reference data for interpretation of scans in daily clinical practice. Such data need to be representative of the population being studied and be "future-proofed" to software and hardware upgrades. The aim was to combine all available pediatric DXA reference data from seven UK centers to create reference curves adjusted for age, sex, ethnicity, and body size to enable clinical application, using in vivo cross-calibration and making data back and forward compatible. Seven UK sites collected data on GE Lunar or Hologic Scanners between 1996 and 2012. Males and females aged 4 to 20 years were recruited (n = 3598). The split by ethnic group was white 2887; South Asian 385; black Afro-Caribbean 286; and mixed heritage 40. Scans of the total body and lumbar spine (L1 to L4 ) were obtained. The European Spine Phantom was used to cross-calibrate the 7 centers and 11 scanners. Reference curves were produced for L1 to L4 bone mineral apparent density (BMAD) and total body less head (TBLH) and L1 to L4 areal bone mineral density (aBMD) for GE Lunar Prodigy and iDXA (sex- and ethnic-specific) and for Hologic (sex-specific). Regression equations for TBLH BMC were produced using stepwise linear regression. Scans of 100 children were randomly selected to test backward and forward compatibility of software versions, up to version 15.0 for GE Lunar and Apex 4.1 for Hologic. For the first time, sex- and ethnic-specific reference curves for lumbar spine BMAD, aBMD, and TBLH aBMD are provided for both GE Lunar and Hologic scanners. These curves will facilitate interpretation of DXA data in children using methods recommended in ISCD guidelines. The databases have been created to allow future updates and analysis when more definitive evidence for the best method of fracture prediction in children is agreed. © 2016 American Society for Bone and Mineral Research.


Assuntos
Tamanho Corporal , Osso e Ossos/anatomia & histologia , Densitometria , Absorciometria de Fóton , Adolescente , Antropometria , Densidade Óssea , Criança , Pré-Escolar , Feminino , Humanos , Vértebras Lombares/fisiologia , Masculino , Imagens de Fantasmas , Valores de Referência , Adulto Jovem