Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
N Engl J Med ; 386(14): 1339-1344, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35388667

RESUMO

Orthostatic hypotension is a cardinal feature of multiple-system atrophy. The upright posture provokes syncopal episodes that prevent patients from standing and walking for more than brief periods. We implanted a system to restore regulation of blood pressure and enable a patient with multiple-system atrophy to stand and walk after having lost these abilities because of orthostatic hypotension. This system involved epidural electrical stimulation delivered over the thoracic spinal cord with accelerometers that detected changes in body position. (Funded by the Defitech Foundation.).


Assuntos
Terapia por Estimulação Elétrica , Hipotensão Ortostática , Atrofia de Múltiplos Sistemas , Acelerometria , Atrofia , Pressão Sanguínea/fisiologia , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Espaço Epidural , Humanos , Hipotensão Ortostática/diagnóstico , Hipotensão Ortostática/etiologia , Hipotensão Ortostática/terapia , Atrofia de Múltiplos Sistemas/terapia , Postura/fisiologia , Vértebras Torácicas
2.
Ann Rheum Dis ; 83(6): 752-759, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38320811

RESUMO

OBJECTIVE: To formulate evidence-based recommendations and overarching principles on the use of imaging in the clinical management of crystal-induced arthropathies (CiAs). METHODS: An international task force of 25 rheumatologists, radiologists, methodologists, healthcare professionals and patient research partners from 11 countries was formed according to the EULAR standard operating procedures. Fourteen key questions on the role of imaging in the most common forms of CiA were generated. The CiA assessed included gout, calcium pyrophosphate deposition disease and basic calcium phosphate deposition disease. Imaging modalities included conventional radiography, ultrasound, CT and MRI. Experts applied research evidence obtained from four systematic literature reviews using MEDLINE, EMBASE and CENTRAL. Task force members provided level of agreement (LoA) anonymously by using a Numerical Rating Scale from 0 to 10. RESULTS: Five overarching principles and 10 recommendations were developed encompassing the role of imaging in various aspects of patient management: making a diagnosis of CiA, monitoring inflammation and damage, predicting outcome, response to treatment, guided interventions and patient education. Overall, the LoA for the recommendations was high (8.46-9.92). CONCLUSIONS: These are the first recommendations that encompass the major forms of CiA and guide the use of common imaging modalities in this disease group in clinical practice.


Assuntos
Artropatias por Cristais , Ultrassonografia , Humanos , Artropatias por Cristais/diagnóstico por imagem , Ultrassonografia/métodos , Condrocalcinose/diagnóstico por imagem , Gota/diagnóstico por imagem , Gota/tratamento farmacológico , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Medicina Baseada em Evidências , Radiografia
3.
Nature ; 563(7729): 65-71, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30382197

RESUMO

Spinal cord injury leads to severe locomotor deficits or even complete leg paralysis. Here we introduce targeted spinal cord stimulation neurotechnologies that enabled voluntary control of walking in individuals who had sustained a spinal cord injury more than four years ago and presented with permanent motor deficits or complete paralysis despite extensive rehabilitation. Using an implanted pulse generator with real-time triggering capabilities, we delivered trains of spatially selective stimulation to the lumbosacral spinal cord with timing that coincided with the intended movement. Within one week, this spatiotemporal stimulation had re-established adaptive control of paralysed muscles during overground walking. Locomotor performance improved during rehabilitation. After a few months, participants regained voluntary control over previously paralysed muscles without stimulation and could walk or cycle in ecological settings during spatiotemporal stimulation. These results establish a technological framework for improving neurological recovery and supporting the activities of daily living after spinal cord injury.


Assuntos
Tecnologia Biomédica , Terapia por Estimulação Elétrica , Paralisia/reabilitação , Traumatismos da Medula Espinal/reabilitação , Caminhada/fisiologia , Atividades Cotidianas , Simulação por Computador , Eletromiografia , Espaço Epidural , Humanos , Perna (Membro)/inervação , Perna (Membro)/fisiologia , Perna (Membro)/fisiopatologia , Locomoção/fisiologia , Masculino , Neurônios Motores/fisiologia , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Músculo Esquelético/fisiopatologia , Paralisia/fisiopatologia , Paralisia/cirurgia , Medula Espinal/citologia , Medula Espinal/fisiologia , Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/fisiopatologia , Traumatismos da Medula Espinal/cirurgia
4.
Skeletal Radiol ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38441616

RESUMO

In musculoskeletal imaging, CT is used in a wide range of indications, either alone or in a synergistic approach with MRI. While MRI is the preferred modality for the assessment of soft tissues and bone marrow, CT excels in the imaging of high-contrast structures, such as mineralized tissue. Additionally, the introduction of dual-energy CT in clinical practice two decades ago opened the door for spectral imaging applications. Recently, the advent of photon-counting detectors (PCDs) has further advanced the potential of CT, at least in theory. Compared to conventional energy-integrating detectors (EIDs), PCDs provide superior spatial resolution, reduced noise, and intrinsic spectral imaging capabilities. This review briefly describes the technical advantages of PCDs. For each technical feature, the corresponding applications in musculoskeletal imaging will be discussed, including high-spatial resolution imaging for the assessment of bone and crystal deposits, low-dose applications such as whole-body CT, as well as spectral imaging applications including the characterization of crystal deposits and imaging of metal hardware. Finally, we will highlight the potential of PCD-CT in emerging applications, underscoring the need for further preclinical and clinical validation to unleash its full clinical potential.

5.
Skeletal Radiol ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662094

RESUMO

When a low-energy trauma induces an acute vertebral fracture (VF) with clinical symptoms, a definitive diagnosis of osteoporotic vertebral fracture (OVF) can be made. Beyond that, a "gold" radiographic standard to distinguish osteoporotic from non-osteoporotic VFs does not exist. Fracture-shaped vertebral deformity (FSVD) is defined as a deformity radiographically indistinguishable from vertebral fracture according to the best of the reading radiologist's knowledge. FSVD is not uncommon among young populations with normal bone strength. FSVD among an older population is called osteoporotic-like vertebral fracture (OLVF) when the FSVD is likely to be associated with compromised bone strength. In more severe grade deformities or when a vertebra is collapsed, OVF diagnosis can be made with a relatively high degree of certainty by experienced readers. In "milder" cases, OVF is often diagnosed based on a high probability rather than an absolute diagnosis. After excluding known mimickers, singular vertebral wedging in older women is statistically most likely an OLVF. For older women, three non-adjacent minimal grade OLVF (< 20% height loss), one minimal grade OLVF and one mild OLVF (20-25% height loss), or one OLVF with ≥ 25% height loss, meet the diagnosis of osteoporosis. For older men, a single OLVF with < 40% height loss may be insufficient to suggest the subject is osteoporotic. Common OLVF differential diagnoses include X-ray projection artifacts and scoliosis, acquired and developmental short vertebrae, osteoarthritic wedging, oncological deformities, deformity due to high-energy trauma VF, lateral hyperosteogeny of a vertebral body, Cupid's bow, and expansive endplate, among others.

6.
J Shoulder Elbow Surg ; 33(5): 1157-1168, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37898420

RESUMO

BACKGROUND: Static posterior subluxation of the humeral head (SPSH) results in glenohumeral osteoarthritis. Treatment strategies for SPSH with or without resulting osteoarthritis remain challenging. There is growing interest in evaluating the rotator cuff muscle volume, fatty infiltration, or forces in osteoarthritic shoulders with SPSH, mainly due to a possible transverse force imbalance. In nonpathological shoulders, the transverse angle of the rotator cuff muscle's resultant force may be associated with scapulohumeral alignment and glenoid vault morphology, despite an assumed transverse force balance. The purpose of this study was to assess the transverse rotator cuff muscle's resultant force angle (TRFA) and its relationship with the scapulohumeral subluxation index (SHSI) and selected glenoid vault parameters using computer modeling. METHODS: Computed tomography scans of 55 trauma patients (age 31 ± 13 years, 36 males) with nonpathological shoulders were analyzed and all measurements performed in 3-dimension. We placed landmarks manually to determine the humeral head center and the rotator cuff tendon footprints. The contours of the rotator cuff muscle cross-sectional areas were automatically predicted in a plane perpendicular to the scapula. Each rotator cuff muscle was divided into virtual vector fibers with homogeneous density. The resultant force vector direction for each muscle, corresponding to the rotator cuff action line, was calculated by vectorially summing the normalized fiber vectors for each muscle, weighted by the muscle trophic ratio. The resultant force vector was projected on the axial plane, and its angle with the mediolateral scapular axis was used to determine TRFA. The SHSI according to Walch, glenoid version angle (GVA), glenoid anteroposterior offset angle (GOA), glenoid depth, glenoid width, and glenoid radius were also evaluated. RESULTS: The mean values for TRFA, SHSI, GVA, GOA, glenoid depth, glenoid width, and glenoid radius were 7.4 ± 4.5°, 54.3 ± 4.8%, -4.1 ± 4.4°, 5.1 ± 10.8°, 3.3 ± 0.6 mm, 20 ± 2 mm, and 33.6 ± 4.6 mm, respectively. The TRFA correlated strongly with SHSI (R = 0.731, P < .001) and GVA (R = 0.716, P < .001) and moderately with GOA (R = 0.663, P < .001). The SHSI was strongly negatively correlated with GVA (R = -0.813, P < .001) and moderately with GOA (R = -0.552, P < .001). The GVA correlated strongly with GOA (R = 0.768, P < .001). In contrast, TRFA, SHSI, GVA, and GOA did not correlate with glenoid depth, width, or radius. CONCLUSION: Despite an assumed balance in the transverse volume of the rotator cuff muscles in nonpathological shoulders, variations exist regarding the transverse resultant force depending on the SHSI, GVA, and GOA. In healthy/nonosteoarthritic shoulders, an increased glenoid retroversion is associated with a decreased anterior glenoid offset.


Assuntos
Luxações Articulares , Osteoartrite , Articulação do Ombro , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Ombro/patologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/patologia , Escápula/diagnóstico por imagem , Escápula/patologia , Luxações Articulares/patologia , Osteoartrite/patologia
7.
Ann Rheum Dis ; 82(10): 1248-1257, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37495237

RESUMO

OBJECTIVE: Calcium pyrophosphate deposition (CPPD) disease is prevalent and has diverse presentations, but there are no validated classification criteria for this symptomatic arthritis. The American College of Rheumatology (ACR) and EULAR have developed the first-ever validated classification criteria for symptomatic CPPD disease. METHODS: Supported by the ACR and EULAR, a multinational group of investigators followed established methodology to develop these disease classification criteria. The group generated lists of candidate items and refined their definitions, collected de-identified patient profiles, evaluated strengths of associations between candidate items and CPPD disease, developed a classification criteria framework, and used multi-criterion decision analysis to define criteria weights and a classification threshold score. The criteria were validated in an independent cohort. RESULTS: Among patients with joint pain, swelling, or tenderness (entry criterion) whose symptoms are not fully explained by an alternative disease (exclusion criterion), the presence of crowned dens syndrome or calcium pyrophosphate crystals in synovial fluid are sufficient to classify a patient as having CPPD disease. In the absence of these findings, a score>56 points using weighted criteria, comprising clinical features, associated metabolic disorders, and results of laboratory and imaging investigations, can be used to classify as CPPD disease. These criteria had a sensitivity of 92.2% and specificity of 87.9% in the derivation cohort (190 CPPD cases, 148 mimickers), whereas sensitivity was 99.2% and specificity was 92.5% in the validation cohort (251 CPPD cases, 162 mimickers). CONCLUSION: The 2023 ACR/EULAR CPPD disease classification criteria have excellent performance characteristics and will facilitate research in this field.


Assuntos
Calcinose , Condrocalcinose , Reumatologia , Humanos , Estados Unidos , Condrocalcinose/diagnóstico por imagem , Pirofosfato de Cálcio , Síndrome
8.
Eur Radiol ; 33(9): 6322-6338, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37191922

RESUMO

OBJECTIVES: The purpose of this agreement was to establish evidence-based consensus statements on imaging of distal radioulnar joint (DRUJ) instability and triangular fibrocartilage complex (TFCC) injuries by an expert group using the Delphi technique. METHODS: Nineteen hand surgeons developed a preliminary list of questions on DRUJ instability and TFCC injuries. Radiologists created statements based on the literature and the authors' clinical experience. Questions and statements were revised during three iterative Delphi rounds. Delphi panelists consisted of twenty-seven musculoskeletal radiologists. The panelists scored their degree of agreement to each statement on an 11-item numeric scale. Scores of "0," "5," and "10" reflected complete disagreement, indeterminate agreement, and complete agreement, respectively. Group consensus was defined as a score of "8" or higher for 80% or more of the panelists. RESULTS: Three of fourteen statements achieved group consensus in the first Delphi round and ten statements achieved group consensus in the second Delphi round. The third and final Delphi round was limited to the one question that did not achieve group consensus in the previous rounds. CONCLUSIONS: Delphi-based agreements suggest that CT with static axial slices in neutral rotation, pronation, and supination is the most useful and accurate imaging technique for the work-up of DRUJ instability. MRI is the most valuable technique in the diagnosis of TFCC lesions. The main indication for MR arthrography and CT arthrography are Palmer 1B foveal lesions of the TFCC. CLINICAL RELEVANCE STATEMENT: MRI is the method of choice for assessing TFCC lesions, with higher accuracy for central than peripheral abnormalities. The main indication for MR arthrography is the evaluation of TFCC foveal insertion lesions and peripheral non-Palmer injuries. KEY POINTS: • Conventional radiography should be the initial imaging technique in the assessment of DRUJ instability. CT with static axial slices in neutral rotation, pronation, and supination is the most accurate method for evaluating DRUJ instability. • MRI is the most useful technique in diagnosing soft-tissue injuries causing DRUJ instability, especially TFCC lesions. • The main indications for MR arthrography and CT arthrography are foveal lesions of the TFCC.


Assuntos
Instabilidade Articular , Fibrocartilagem Triangular , Traumatismos do Punho , Humanos , Fibrocartilagem Triangular/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Artrografia , Articulação do Punho/diagnóstico por imagem , Artroscopia/métodos
9.
Semin Musculoskelet Radiol ; 27(5): 588-595, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37816367

RESUMO

This opinion article by the European Society of Musculoskeletal Radiology Arthritis and Pediatric Subcommittees discusses the current use of conventional radiography (CR) of the sacroiliac joints in adults and juveniles with suspected axial spondyloarthritis (axSpA). The strengths and limitations of CR compared with magnetic resonance imaging (MRI) and computed tomography (CT) are presented.Based on the current literature and expert opinions, the subcommittees recognize the superior sensitivity of MRI to detect early sacroiliitis. In adults, supplementary pelvic radiography, low-dose CT, or synthetic CT may be needed to evaluate differential diagnoses. CR remains the method of choice to detect structural changes in patients with suspected late-stage axSpA or established disease and in patients with suspected concomitant hip or pubic symphysis involvement. In children, MRI is the imaging modality of choice because it can detect active as well as structural changes and is radiation free.


Assuntos
Espondiloartrite Axial , Sacroileíte , Espondilartrite , Humanos , Adulto , Criança , Articulação Sacroilíaca/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem , Espondilartrite/patologia , Radiografia , Sacroileíte/diagnóstico por imagem , Sacroileíte/patologia , Imageamento por Ressonância Magnética/métodos
10.
Sensors (Basel) ; 23(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37050647

RESUMO

Inertial measurement unit (IMU) sensors are widely used for motion analysis in sports and rehabilitation. The attachment of IMU sensors to predefined body segments and sides (left/right) is complex, time-consuming, and error-prone. Methods for solving the IMU-2-segment (I2S) pairing work properly only for a limited range of gait speeds or require a similar sensor configuration. Our goal was to propose an algorithm that works over a wide range of gait speeds with different sensor configurations while being robust to footwear type and generalizable to pathologic gait patterns. Eight IMU sensors were attached to both feet, shanks, thighs, sacrum, and trunk, and 12 healthy subjects (training dataset) and 22 patients (test dataset) with medial compartment knee osteoarthritis walked at different speeds with/without insole. First, the mean stride time was estimated and IMU signals were scaled. Using a decision tree, the body segment was recognized, followed by the side of the lower limb sensor. The accuracy and precision of the whole algorithm were 99.7% and 99.0%, respectively, for gait speeds ranging from 0.5 to 2.2 m/s. In conclusion, the proposed algorithm was robust to gait speed and footwear type and can be widely used for different sensor configurations.


Assuntos
Marcha , Caminhada , Humanos , Extremidade Inferior , Perna (Membro) , , Fenômenos Biomecânicos
11.
Rheumatology (Oxford) ; 61(12): 4898-4904, 2022 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-35293984

RESUMO

OBJECTIVES: Pegloticase rapidly lowers serum urate in uncontrolled/refractory gout patients, with ≥1 tophus resolution in 70% of pegloticase responders and 28% of non-responders. Dual-energy computed tomography (DECT) non-invasively detects MSU deposition, including subclinical deposition, quantifies MSU volumes and depicts bone erosions. This report presents DECT findings in MIRROR open-label trial participants receiving pegloticase+MTX co-therapy. METHODS: Serial DECT scans were obtained during pegloticase (8 mg biweekly infusions)+oral MTX (15 mg/week) co-therapy. Bilateral hand/wrist, elbow, foot/ankle and knee images were analysed with default post-processing settings. MSU volumes were quantified and bone erosions were identified and evaluated for remodelling (decreased size, sclerosis, new bone formation). DECT and physical examination findings were compared. RESULTS: 2 patients underwent serial DECT. Patient 1 (44-year-old male) completed 52 weeks of pegloticase+MTX co-therapy (26 infusions). Baseline examination detected 4 tophus-affected joints while DECT identified 73 MSU-affected joints (total MSU volume: 128.76 cm3). At end-of-treatment, there were no clinically-affected joints and 4 joints with DECT-detected MSU deposition. MSU volume decreased by 99% and bone erosion remodelling was evident. Patient 2 (51-year-old male) had 10 weeks of therapy (5 infusions), discontinuing because of urate-lowering response loss. Baseline examination detected 7 tophus-affected joints while DECT identified 55 MSU-affected joints (total MSU volume: 59.20 cm3). At end-of-treatment, there were 5 clinically affected joints and 42 joints with DECT-detected MSU deposition. MSU volume decreased by 58% and bone erosion remodelling was evident. CONCLUSION: DECT detected subclinical MSU deposition and quantified changes over time. Rapid tophus resolution and bone erosion remodelling occurred during pegloticase+MTX co-therapy. TRIAL REGISTRATION: ClinicalTrials.gov, https://clinicaltrials.gov, NCT03635957.


Assuntos
Artrite Gotosa , Gota , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Ácido Úrico , Metotrexato/uso terapêutico , Tomografia Computadorizada por Raios X , Gota/tratamento farmacológico
12.
Eur Radiol ; 32(1): 524-532, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34185147

RESUMO

OBJECTIVES: To evaluate the image quality (IQ) of a spectral photon-counting CT (SPCCT) using filtered back projection (FBP) and hybrid iterative reconstruction (IR) algorithms (iDose4), in comparison with a dual-layer CT (DLCT) system, and to choose the best image quality according to the IR level for SPCCT. METHODS: Two phantoms were scanned using a standard lung protocol (120 kVp, 40 mAs) with SPCCT and DLCT systems. Raw data were reconstructed using FBP and 9 iDose4 levels (i1/i2/i3/i4/i5/i6/i7/i9/i11) for SPCCT and 7 for DLCT (i1/i2/i3/i4/i5/i6/i7). Noise power spectrum and task-based transfer function (TTF) were computed. Detectability index (d') was computed for detection of 4 mm ground-glass nodule (GGN) and solid nodule. Two chest radiologists performed an IQ evaluation (noise/nodule sharpness/nodule conspicuity/overall IQ) in consensus, and chose the best image for SPCCT. RESULTS: Noise magnitude was -47% ± 2% lower on average with SPCCT than with DLCT for iDose4 range from i1 to i6. Average NPS spatial frequencies increased for SPCCT in comparison with DLCT. TTF also increased, except for the air insert with FBP, and i1/i2/i3. Higher detectability was found for SPCCT for both GGN and solid nodules. IQ for both types of nodule was rated consistently higher with SPCCT than with DLCT for the same iDose4 level. For SPCCT and both nodules, the scores for noise and conspicuity improved with increasing iDose4 level. iDose4 level 6 provided the best subjective IQ for both types of nodule. CONCLUSIONS: Higher IQ for GGN and solid nodules was demonstrated with SPCCT compared with DLCT with better detectability using iDose4. KEY POINTS: Using spectral photon-counting CT compared with dual-layer CT, noise magnitude was reduced with improvements in spatial resolution and detectability of ground-glass nodules and solid lung nodules. As the iDose4 level increased, noise magnitude was reduced and detectability of ground-glass and solid lung nodules was better for both CT systems. For spectral photon-counting CT imaging, two chest radiologists determined iDose4 level 6 as the best image quality for detecting ground-glass nodules and solid lung nodules.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação
13.
Surg Radiol Anat ; 44(2): 201-205, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35024904

RESUMO

Ulnar/cubital tunnel syndrome is the second most common compressive neuropathy of the upper limb. Permanent location of the ulnar nerve anterior to the medial epicondyle is extremely rare, with only five cases reported in the literature. Using ultrasound elastography and diffusion tensor imaging with fiber tractography, we diagnosed a case in which ulnar nerve entrapment was associated with anterior nerve location. Surgical release confirmed the diagnosis and the patient was symptom free 3 months after surgery.


Assuntos
Síndrome do Túnel Ulnar , Técnicas de Imagem por Elasticidade , Síndromes de Compressão do Nervo Ulnar , Imagem de Tensor de Difusão , Humanos , Nervo Ulnar/diagnóstico por imagem , Síndromes de Compressão do Nervo Ulnar/diagnóstico por imagem
14.
Rheumatology (Oxford) ; 60(10): 4861-4867, 2021 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-33410491

RESUMO

OBJECTIVE: To examine the accuracy of dual-energy CT (DECT) vs ultrasound or their combination for the diagnosis of gout. METHODS: Using prospectively collected data from an outpatient rheumatology clinic at a tertiary-care hospital, we examined the diagnostic accuracy of either modality alone or their combination, by anatomical site (feet/ankles and/or knees), for the diagnosis of gout. We used two standards: (i) demonstration of monosodium urate crystals in synovial fluid (gold), and (ii) modified (excluding DECT and ultrasound) 2015 ACR-EULAR gout classification criteria (silver). RESULTS: Of the 147 patients who provided data, 48 (33%) had synovial fluid analysis performed (38 were monosodium urate-crystal positive) and mean symptom duration was 9.2 years. One hundred (68%) patients met the silver standard. Compared with the gold standard, diagnostic accuracy statistics for feet/ankles DECT, feet/ankles ultrasound, knees DECT and knees ultrasound were, respectively: sensitivity: 87%, 84%, 91% and 58%; specificity: 100%, 60%, 87% and 80%; positive predictive value: 100%, 89%, 97% and 92%; negative predictive value: 67%, 50%, 70% and 33%; area under the receiver operating characteristic curve: 0.93, 0.72, 0.89 and 0.66. Combining feet/ankles DECT with ultrasound or knees DECT with ultrasound led to a numerically higher sensitivity compared with DECT alone, but overall accuracy was lower. Similarly, combining imaging knees to feet/ankles also yielded a numerically higher sensitivity and negative predictive values compared with feet/ankles DECT alone, without differences in overall accuracy. Findings were replicated compared with the silver standard, but with lower numbers. CONCLUSIONS: Feet/ankles or knees DECT alone had the best overall accuracy for gout diagnosis. The DECT-US combination or multiple joint imaging offered no additional increase in overall diagnostic accuracy.


Assuntos
Gota/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto , Idoso , Feminino , Gota/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos
15.
Eur Radiol ; 31(1): 181-190, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32696257

RESUMO

OBJECTIVES: This study aimed at developing a convolutional neural network (CNN) able to automatically quantify and characterize the level of degeneration of rotator cuff (RC) muscles from shoulder CT images including muscle atrophy and fatty infiltration. METHODS: One hundred three shoulder CT scans from 95 patients with primary glenohumeral osteoarthritis undergoing anatomical total shoulder arthroplasty were retrospectively retrieved. Three independent radiologists manually segmented the premorbid boundaries of all four RC muscles on standardized sagittal-oblique CT sections. This premorbid muscle segmentation was further automatically predicted using a CNN. Automatically predicted premorbid segmentations were then used to quantify the ratio of muscle atrophy, fatty infiltration, secondary bone formation, and overall muscle degeneration. These muscle parameters were compared with measures obtained manually by human raters. RESULTS: Average Dice similarity coefficients for muscle segmentations obtained automatically with the CNN (88% ± 9%) and manually by human raters (89% ± 6%) were comparable. No significant differences were observed for the subscapularis, supraspinatus, and teres minor muscles (p > 0.120), whereas Dice coefficients of the automatic segmentation were significantly higher for the infraspinatus (p < 0.012). The automatic approach was able to provide good-very good estimates of muscle atrophy (R2 = 0.87), fatty infiltration (R2 = 0.91), and overall muscle degeneration (R2 = 0.91). However, CNN-derived segmentations showed a higher variability in quantifying secondary bone formation (R2 = 0.61) than human raters (R2 = 0.87). CONCLUSIONS: Deep learning provides a rapid and reliable automatic quantification of RC muscle atrophy, fatty infiltration, and overall muscle degeneration directly from preoperative shoulder CT scans of osteoarthritic patients, with an accuracy comparable with that of human raters. KEY POINTS: • Deep learning can not only segment RC muscles currently available in CT images but also learn their pre-existing locations and shapes from invariant anatomical structures visible on CT sections. • Our automatic method is able to provide a rapid and reliable quantification of RC muscle atrophy and fatty infiltration from conventional shoulder CT scans. • The accuracy of our automatic quantitative technique is comparable with that of human raters.


Assuntos
Aprendizado Profundo , Lesões do Manguito Rotador , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Humanos , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/patologia , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/patologia , Ombro , Tomografia Computadorizada por Raios X
16.
Eur Radiol ; 31(3): 1517-1525, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32901303

RESUMO

OBJECTIVES: To assess the interobserver reliability (IOR) of the Tile classification system, and its potential influence on outcomes, for the interpretation of CT images of pelvic fractures by radiologists and surgeons. METHODS: Retrospective data (1/2008-12/2016) from 238 patients with pelvic fractures were analyzed. Mean patient age was 44 years (SD 20); 66% were male. There were 54 Tile A, 82 Tile B, and 102 Tile C type injuries. The 30-day mortality rate was 15% (36/238). Six observers, three radiologists, and three surgeons with different levels of experience (attending/resident/intern) classified each fracture into one of the 26 second-order subcategories of the Tile classification. Weighted kappa coefficients were used to assess the IORs for the three main categories and nine first-order subcategories. RESULTS: The overall IORs of the Tile system for the main categories and first-order subcategories were moderate (kappa = 0.44) and fair (kappa = 0.31), respectively. IOR was fair to moderate among radiologists, but only fair among surgeons. By level of training, IOR was moderate between attendings and between residents, whereas it was only fair between interns. IOR was moderate to substantial (kappa = 0.56-0.70) between the radiology attending and resident. Association of the Tile fracture type with 30-day mortality was present based on two out of six observer ratings. CONCLUSIONS: The overall IOR of the Tile classification system is only fair to moderate, increases with the level of rater experience and is better among radiologists than surgeons. In the light of these findings, results from studies using this classification system must be interpreted cautiously. KEY POINTS: • The overall interobserver reliability of the Tile pelvic fracture classification is only fair to moderate. • Interobserver reliability increases with observer experience and radiologists have higher kappa coefficients than surgeons. • Interobserver reliability has an impact on the association of the Tile classification system with mortality in two out of six cases.


Assuntos
Radiologistas , Cirurgiões , Adulto , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Eur Radiol ; 31(9): 7132-7142, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33740093

RESUMO

OBJECTIVES: To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. MATERIALS AND METHODS: A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. RESULTS: In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). CONCLUSION: In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. KEY POINTS: • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Meios de Contraste , Relação Dose-Resposta a Droga , Humanos , Iodo/administração & dosagem , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
18.
Eur Radiol ; 31(12): 9446-9458, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34100996

RESUMO

OBJECTIVES: The purpose of this agreement was to establish evidence-based consensus statements on imaging of scapholunate joint (SLJ) instability by an expert group using the Delphi technique. METHODS: Nineteen hand surgeons developed a preliminary list of questions on SLJ instability. Radiologists created statements based on the literature and the authors' clinical experience. Questions and statements were revised during three iterative Delphi rounds. Delphi panellists consisted of twenty-seven musculoskeletal radiologists. The panellists scored their degree of agreement to each statement on an eleven-item numeric scale. Scores of '0', '5' and '10' reflected complete disagreement, indeterminate agreement and complete agreement, respectively. Group consensus was defined as a score of '8' or higher for 80% or more of the panellists. RESULTS: Ten of fifteen statements achieved group consensus in the second Delphi round. The remaining five statements achieved group consensus in the third Delphi round. It was agreed that dorsopalmar and lateral radiographs should be acquired as routine imaging work-up in patients with suspected SLJ instability. Radiographic stress views and dynamic fluoroscopy allow accurate diagnosis of dynamic SLJ instability. MR arthrography and CT arthrography are accurate for detecting scapholunate interosseous ligament tears and articular cartilage defects. Ultrasonography and MRI can delineate most extrinsic carpal ligaments, although validated scientific evidence on accurate differentiation between partially or completely torn or incompetent ligaments is not available. CONCLUSIONS: Delphi-based agreements suggest that standardized radiographs, radiographic stress views, dynamic fluoroscopy, MR arthrography and CT arthrography are the most useful and accurate imaging techniques for the work-up of SLJ instability. KEY POINTS: • Dorsopalmar and lateral wrist radiographs remain the basic imaging modality for routine imaging work-up in patients with suspected scapholunate joint instability. • Radiographic stress views and dynamic fluoroscopy of the wrist allow accurate diagnosis of dynamic scapholunate joint instability. • Wrist MR arthrography and CT arthrography are accurate for determination of scapholunate interosseous ligament tears and cartilage defects.


Assuntos
Instabilidade Articular , Traumatismos do Punho , Artrografia , Consenso , Humanos , Instabilidade Articular/diagnóstico por imagem , Ligamentos Articulares/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem , Articulação do Punho
19.
BMC Musculoskelet Disord ; 22(1): 49, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33419412

RESUMO

BACKGROUND: Aseptic loosening of glenoid implants is the primary revision cause in anatomic total shoulder arthroplasty (aTSA). While supported by biomechanical studies, the impact of glenoid bone quality, more specifically bone mineral density (BMD), on aseptic glenoid loosening remains unclear. We hypothesized that lower preoperative glenoid BMD was associated with aseptic glenoid implant loosening in aTSA. METHODS: We retrospectively included 93 patients (69 females and 24 males; mean age, 69.2 years) who underwent preoperative non-arthrographic shoulder computed tomography (CT) scans and aTSA between 2002 and 2014. Preoperative glenoid BMD (CT numbers in Hounsfield unit) was measured in 3D using a reliable semi-automated quantitative method, in the following six contiguous volumes of interest (VOI): cortical, subchondral cortical plate (SC), subchondral trabecular, and three successive adjacent layers of trabecular bone. Univariate Cox regression was used to estimate the impact of preoperative glenoid BMD on aseptic glenoid implant loosening. We further compared 26 aseptic glenoid loosening patients with 56 matched control patients. RESULTS: Glenoid implant survival rates were 89% (95% confidence interval CI, 81-96%) and 57% (41-74%) at 5 and 10 years, respectively. Hazard ratios for the different glenoid VOIs ranged between 0.998 and 1.004 (95% CI [0.996, 1.007], p≥0.121). Only the SC VOI showed significantly lower CTn in the loosening group (622±104 HU) compared with the control group (658±88 HU) (p=0.048), though with a medium effect size (d=0.42). There were no significant differences in preoperative glenoid BMD in any other VOI between patients from the loosening and control groups. CONCLUSIONS: Although the preoperative glenoid BMD was statistically significantly lower in the SC region of patients with aseptic glenoid implant loosening compared with controls, this single-VOI difference was only moderate. We are thus unable to prove that lower preoperative glenoid BMD is clearly associated with aseptic glenoid implant loosening in aTSA. However, due to its proven biomechanical role in glenoid implant survival, we recommend extending this study to larger CT datasets to further assess and better understand the impact of preoperative glenoid BMD on glenoid implant loosening/survival and aTSA outcome.


Assuntos
Artroplastia do Ombro , Cavidade Glenoide , Articulação do Ombro , Prótese de Ombro , Idoso , Artroplastia do Ombro/efeitos adversos , Densidade Óssea , Feminino , Cavidade Glenoide/diagnóstico por imagem , Humanos , Masculino , Falha de Prótese , Estudos Retrospectivos , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Prótese de Ombro/efeitos adversos
20.
Surg Radiol Anat ; 43(5): 721-726, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33398519

RESUMO

PURPOSE: The flexor carpi radialis brevis (FCRB) is a supernumerary musculotendinous structure of the wrist that has been the focus of some interest in the last decade. While its anatomy is well known, its in vivo function remains unknown as it has never been studied. METHODS: Eleven cases of FCRB underwent a multimodal ultrasound consisting of B-mode, color Doppler and shear wave elastography. RESULTS: A pennate shape was observed in all cases and the mean value of the cross-sectional area was 0.8 cm2 (SD 0.3 cm2). Young's modulus was significantly (p < 0.01) different between the resting position and active flexion or passive extension. CONCLUSION: Our study demonstrates that the FCRB shows biomechanics of a typical skeletal muscle and is voluntarily controlled by flexing the wrist. Absent in other vertebrate taxa, the FCRB probably plays a role in active stability of the wrist in Human.


Assuntos
Variação Anatômica , Antebraço/anormalidades , Músculo Esquelético/anormalidades , Punho/anormalidades , Adulto , Fenômenos Biomecânicos , Técnicas de Imagem por Elasticidade , Feminino , Antebraço/diagnóstico por imagem , Antebraço/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Ultrassonografia Doppler em Cores , Punho/diagnóstico por imagem , Punho/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA