Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39004997

RESUMO

BACKGROUND: To clarify whether next-generation sequencing (NGS) can be useful for resistance assessment in virologically suppressed highly treatment-experienced (HTE) individuals with MDR HIV. METHODS: Ninety-one participants from the PRESTIGIO Registry were included. NGS was performed on HIV-DNA at 1%, 5% and 20% cut-offs; major drug resistance mutations (DRMs) were evaluated and compared with those detected in historical plasma genotypic resistance testing (h-GRT). APOBEC editing was also characterized. RESULTS: Participants had a complex and long treatment history [median 23 (IQR 21-25) years of ART exposure) and had been virologically suppressed since a median of 3 (IQR 2-5) years. Among all major DRMs detected by HIV-DNA NGS and/or h-GRT, 30% were exclusively found through NGS. The highest detection rate of historical major DRMs was reached with NGS set at 1%, but unusual substitutions and extensive APOBEC hypermutations suggest technical issues and poor clinical relevance in the 1%-5% interval. At NGS set at 5%, 67.2% of historical major DRMs were detected. The number of major DRMs detected exclusively by DNA-NGS as minority variants (frequency 5%-20%) was significantly higher in individuals who later experienced virological rebound compared with those who maintained virological control [median 2 (IQR 1-3) versus 1 (0-2), P = 0.030] and positively correlated with viraemia levels at rebound (rho = 0.474, P = 0.030). CONCLUSIONS: In non-viraemic people with an MDR virus, HIV-1 DNA NGS set at 5% is an acceptable technical cut-off that might help to reveal mutations with a potential clinical relevance. Moreover, the number of minority resistance mutations additionally detected by NGS might be associated with loss of virological control.

2.
Pancreatology ; 24(4): 538-544, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38693038

RESUMO

BACKGROUND/OBJECTIVES: Autoimmune pancreatitis (AIP) is a steroid-responsive inflammatory disease of the pancreas. Few studies investigated pancreatic exocrine function (PEF) in patients suffering from AIP and no definitive data are available on the effect of steroids in PEF recovery. Aim of the study is the evaluation of severe pancreatic insufficiency (sPEI) prevalence in AIP at clinical onset and after steroid treatment. METHODS: 312 Patients with diagnosis of AIP between January 1st, 2010 and December 31st, 2020 were identified in our prospectively maintained register. Patients with a pre-steroid treatment dosage of fecal elastase-1 (FE-1) were included. Changes in PEF were evaluated in patients with available pre- and post-treatment FE (between 3 and 12 months after steroid). RESULTS: One-hundred-twenty-four patients were included, with a median FE-1 of 122 (Q1-Q3: 15-379) µg/g at baseline. Fifty-nine (47.6 %) had sPEI (FE-1<100 µg/g). Univariable analysis identified type 1 AIP, radiological involvement of the head of the pancreas (diffuse involvement of the pancreas or focal involvement of the head), weight loss, age and diabetes as associated with a greater risk of sPEI. However, at multivariable analysis, only the involvement of the head of the pancreas was identified as independent risk factor for sPEI. After steroids, mean FE-1 changed from 64 (15-340) to 202 (40-387) µg/g (P = 0.058) and head involvement was the only predictor of improvement of sPEI. CONCLUSION: The inflammatory involvement of the head of the pancreas is associated with PEF severity, as well as PEF improvement after treatment with steroids in patients with AIP.


Assuntos
Pancreatite Autoimune , Insuficiência Pancreática Exócrina , Humanos , Pancreatite Autoimune/tratamento farmacológico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência Pancreática Exócrina/tratamento farmacológico , Pâncreas Exócrino/efeitos dos fármacos , Adulto , Esteroides/uso terapêutico , Elastase Pancreática
3.
Ann Intern Med ; 176(3): 303-310, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802754

RESUMO

BACKGROUND: Colorectal cancer (CRC) screening programs based on fecal immunochemical tests (FITs) represent the standard of care for population-based interventions. Their benefit depends on the identification of neoplasia at colonoscopy after FIT positivity. Colonoscopy quality measured by adenoma detection rate (ADR) may affect screening program effectiveness. OBJECTIVE: To examine the association between ADR and postcolonoscopy CRC (PCCRC) risk in a FIT-based screening program. DESIGN: Retrospective population-based cohort study. SETTING: Fecal immunochemical test-based CRC screening program between 2003 and 2021 in northeastern Italy. PATIENTS: All patients with a positive FIT result who had a colonoscopy were included. MEASUREMENTS: The regional cancer registry supplied information on any PCCRC diagnosed between 6 months and 10 years after colonoscopy. Endoscopists' ADR was categorized into 5 groups (20% to 39.9%, 40% to 44.9%, 45% to 49.9%, 50% to 54.9%, and 55% to 70%). To examine the association of ADR with PCCRC incidence risk, Cox regression models were fitted to estimate hazard ratios (HRs) and 95% CIs. RESULTS: Of the 110 109 initial colonoscopies, 49 626 colonoscopies done by 113 endoscopists between 2012 and 2017 were included. After 328 778 person-years follow-up, 277 cases of PCCRC were diagnosed. Mean ADR was 48.3% (range, 23% and 70%). Incidence rates of PCCRC from lowest to highest ADR group were 13.13, 10.61, 7.60, 6.01, and 5.78 per 10 000 person-years. There was a significant inverse association between ADR and PCCRC incidence risk, with a 2.35-fold risk increase (95% CI, 1.63 to 3.38) in the lowest group compared with the highest. The adjusted HR for PCCRC associated with 1% increase in ADR was 0.96 (CI, 0.95 to 0.98). LIMITATION: Adenoma detection rate is partly determined by FIT positivity cutoff; exact values may vary in different settings. CONCLUSION: In a FIT-based screening program, ADR is inversely associated with PCCRC incidence risk, mandating appropriate colonoscopy quality monitoring in this setting. Increasing endoscopists' ADR may significantly reduce PCCRC risk. PRIMARY FUNDING SOURCE: None.


Assuntos
Adenoma , Neoplasias Colorretais , Humanos , Estudos de Coortes , Estudos Retrospectivos , Detecção Precoce de Câncer , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/epidemiologia , Colonoscopia , Adenoma/diagnóstico , Adenoma/epidemiologia , Convulsões , Programas de Rastreamento
4.
Dig Endosc ; 36(4): 428-436, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37522554

RESUMO

OBJECTIVES: The aim of the current study was to compare the efficacy of partially covered duodenal stent (PCDS) vs. uncovered duodenal stent (UCDS) in patients suffering from unresectable primary malignant gastric outlet obstruction (GOO). METHODS: This was a prospective international randomized controlled study conducted in 10 high-volume institutions. Consecutive patients suffering from malignant GOO were recruited. The primary outcome measurement was the reintervention rate. Secondary outcomes included technical and clinical success, 30-day adverse events, 30-day mortality, causes of stent dysfunction, and the duration of stent patency. RESULTS: Between March 2017 and October 2020, 115 patients (59 PCDS, 56 UCDS) were recruited. The 1-year reintervention was not significantly different (PCDS vs. UDCS = 12/59, 20.3% vs. 14/56, 25%, P = 0.84). There was a trend to fewer patients with tumor ingrowth in the PCDS group (6/59 [10.2%]) vs. 13/56 [23.2%], P = 0.07). There were no significant differences in the technical success (100% vs. 100%, P = 1), clinical success (91.5% vs. 98.2%, P = 0.21), procedural time (21.5 [interquartile range [IQR] 17-30] vs. 20.0 [IQR 15-34.75], P = 0.62), hospital stay (4 [IQR 3-12] vs. 5 [IQR 3-8] days, P = 0.81), 30-day adverse events (18.6% vs. 14.3%, P = 0.62), or 30-day mortality (6.8% vs. 5.2%, P = 1.00). CONCLUSION: The use of PCDS was associated with a lower risk of tumor ingrowth but did not improve on reintervention rates or stent patency. Both kinds of stents could be used in this group of patients.


Assuntos
Obstrução da Saída Gástrica , Neoplasias , Humanos , Estudos Prospectivos , Resultado do Tratamento , Stents/efeitos adversos , Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Cuidados Paliativos
5.
Pancreatology ; 23(4): 429-436, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37169669

RESUMO

BACKGROUND/OBJECTIVES: Death domain-associated protein (DAXX) and/or α-thalassemia/mental retardation X-linked (ATRX) chromatin remodeling genes mutations and alternative lengthening of telomeres (ALT) activation are associated with more aggressive behavior of non-functional pancreatic neuroendocrine tumors (NF-PanNETs). We aimed to evaluate the reliability of such markers on endoscopic-ultrasound fine-needle biopsy (EUS-FNB) specimens. METHODS: Patients who underwent EUS-FNB and subsequent surgical resection for PanNETs between January 2017 and December 2019 were retrospectively identified. Immunohistochemistry (IHC) to evaluate DAXX/ATRX expression and fluorescence in situ hybridization (FISH) for ALT status were performed. Primary outcome was the concordance rate of markers expression between EUS-FNB and surgical specimens. Secondary aims were association between markers and lesion aggressiveness, their diagnostic performance in predicting aggressiveness, and agreement of preoperative and post-surgical Ki67-based grading. RESULTS: Forty-one NF-PanNETs (mean diameter 36.1 ± 26.5 mm) were included. Twenty-four showed features of lesion aggressiveness. Concordance of expressions of DAXX, ATRX, and ALT status between EUS-FNB and surgical specimens were 95.1% (κ = 0.828; p < 0.001), 92.7% (κ = 0.626; p < 0.001), and 100% (κ = 1; p < 0.001), respectively. DAXX/ATRX loss and ALT-positivity were significantly (p < 0.05) associated with metastatic lymphnodes and lymphovascular invasion. The combination of all tumor markers (DAXX/ATRX loss + ALT-positivity + grade 2) reached an accuracy of 73.2% (95%CI 57.1-85.8) in identifying aggressive lesions. Pre- and post-operative ki-67-based grading was concordant in 80.5% of cases (k = 0.573; p < 0.001). CONCLUSION: DAXX/ATRX expression and ALT status can be accurately evaluated in a preoperative setting on EUS-FNB samples, potentially improving the identification of patients with increased risk and poorer prognosis.


Assuntos
Deficiência Intelectual , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Talassemia alfa , Humanos , Proteína Nuclear Ligada ao X/genética , Proteína Nuclear Ligada ao X/metabolismo , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/genética , Tumores Neuroendócrinos/cirurgia , Estudos Retrospectivos , Biópsia por Agulha Fina , Hibridização in Situ Fluorescente , Reprodutibilidade dos Testes , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/cirurgia , Telômero/genética , Telômero/metabolismo , Telômero/patologia , Chaperonas Moleculares/genética , Proteínas Correpressoras/genética
6.
Endoscopy ; 55(3): 225-234, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35915956

RESUMO

BACKGROUND : It is unknown whether there is an advantage to using the wet-suction or slow-pull technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with new-generation needles. We aimed to compare the performance of each technique in EUS-FNB. METHODS: This was a multicenter, randomized, single-blind, crossover trial including patients with solid lesions of ≥ 1 cm. Four needle passes with 22 G fork-tip or Franseen-type needles were performed, alternating the wet-suction and slow-pull techniques in a randomized order. The primary outcome was the histological yield (samples containing an intact piece of tissue of at least 550 µm). Secondary end points were sample quality (tissue integrity and blood contamination), diagnostic accuracy, and adequate tumor fraction. RESULTS: Overall, 210 patients with 146 pancreatic and 64 nonpancreatic lesions were analyzed. A tissue core was retrieved in 150 (71.4 %) and 129 (61.4 %) cases using the wet-suction and the slow-pull techniques, respectively (P = 0.03). The mean tissue integrity score was higher using wet suction (P = 0.02), as was the blood contamination of samples (P < 0.001). In the two subgroups of pancreatic and nonpancreatic lesions, tissue core rate and tissue integrity score were not statistically different using the two techniques, but blood contamination was higher with wet suction. Diagnostic accuracy and tumor fraction did not differ between the two techniques. CONCLUSION: Overall, the wet-suction technique in EUS-FNB resulted in a higher tissue core procurement rate compared with the slow-pull method. Diagnostic accuracy and the rate of samples with adequate tumor fraction were similar between the two techniques.


Assuntos
Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Sucção/métodos , Estudos Cross-Over , Método Simples-Cego , Pâncreas/diagnóstico por imagem , Pâncreas/patologia
7.
Endoscopy ; 55(2): 129-137, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36044915

RESUMO

BACKGROUND : The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes. METHODS : This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10 mm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety. RESULTS : 370 patients with 234 pancreatic lesions (63.2 %) and 136 nonpancreatic lesions (36.8 %) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0 % [95 %CI 84.8 %-93.9 %] vs. 87.8 % [95 %CI 82.1 %-92.2 %]; P = 0.49), sample adequacy (93.1 % [95 %CI 88.6 %-96.3 %] vs. 95.5 % [95 %CI 91.4 %-98 %]; P = 0.31), and rate of adverse events (2.6 % vs. 1.1 %; P = 0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; P < 0.001). CONCLUSIONS : The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.


Assuntos
Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Biópsia Guiada por Imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia
8.
Dig Endosc ; 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37712906

RESUMO

OBJECTIVES: Repeated endoscopic ultrasound (EUS)-guided tissue acquisition represents the standard practice for solid pancreatic lesions after previous nondiagnostic or inconclusive results. Since data are lacking, we aimed to evaluate the diagnostic performance of repeated EUS fine-needle biopsy (rEUS-FNB) in this setting. The primary outcome was diagnostic accuracy; sample adequacy, sensitivity, specificity, and safety were secondary outcomes. METHODS: Consecutive patients undergoing rEUS-FNB for solid pancreatic lesions at 23 Italian centers from 2019 to 2021 were retrieved. Pathology on the surgical specimen, malignant histology together with ≥6-month follow-up, and benign pathology together with ≥12-month follow-up were adopted as gold standards. RESULTS: Among 462 patients, 56.5% were male, with a median age of 68 (59-75) years, malignancy prevalence 77.0%. Tumor size was 26 (20-35) mm. Second-generation FNB needles were used in 89.6% cases. Diagnostic accuracy, sensitivity, and specificity of rEUS-FNB were 89.2%, 91.4%, and 81.7%, respectively (19 false-negative and 12 false-positive results). On multivariate analysis, rEUS-FNB performed at high-volume centers (odds ratio [OR] 2.12; 95% confidence interval [CI] 1.10-3.17; P = 0.03) and tumor size (OR 1.03; 95% CI 1.00-1.06; P = 0.05) were independently related to diagnostic accuracy. Sample adequacy was 94.2%. Use of second-generation FNB needles (OR 5.42; 95% CI 2.30-12.77; P < 0.001) and tumor size >23 mm (OR 3.04; 95% CI 1.31-7.06; P = 0.009) were independently related to sample adequacy. CONCLUSION: Repeated EUS-FNB allowed optimal diagnostic performance after nondiagnostic or inconclusive results. Patients' referral to high-volume centers improved diagnostic accuracy. The use of second-generation FNB needles significantly improved sample adequacy over standard EUS-FNB needles.

9.
Gastrointest Endosc ; 95(1): 115-122, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34339667

RESUMO

BACKGROUND AND AIMS: Electrocautery-tip lumen-apposing metal stents (EC-LAMSs) have extended the indications of therapeutic EUS. We aimed to retrospectively evaluate safety and technical and clinical success of a newly developed EC-LAMS, the Hot-Spaxus (Taewoong Medical Co, Gimpo, Korea), for various EUS-guided procedures. METHODS: We included and retrospectively analyzed consecutive patients at 8 tertiary care referral centers who had undergone EUS interventional procedures using the Hot-Spaxus between October 2018 and February 2021. RESULTS: Of 58 included patients (male-to-female, 36:22; mean age, 63.5 ± 14.9 years), 29 had undergone pancreatic fluid collection drainage (50%), 22 (37.9%) biliary drainage for malignant distal obstruction, 3 (5.1%) gallbladder drainage for acute cholecystitis, 3 gastroenteroanastomoses, and 1 (1.7%) pelvic collection drainage. Technical success was achieved in 54 of 58 patients (93.1%) and clinical success in all 58. Adverse events occurred in 6 patients (11.1%): 2 early (3.7%), 1 late (1.8%), and 3 long term (5.6%). The outcomes were similar to those observed in a control group of patients treated with the Hot-Axios (Boston Scientific, Marlborough, Mass, USA), the other available EC-LAMS. CONCLUSIONS: Our study showed that the novel EC-LAMS has high technical and clinical success rates for various interventional EUS indications. Future multicenter prospective studies will better clarify the role of this new EC-LAMS for different indications.


Assuntos
Endossonografia , Stents , Idoso , Drenagem , Eletrocoagulação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Ultrassonografia de Intervenção
10.
Endoscopy ; 54(12): 1158-1168, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35451041

RESUMO

BACKGROUND AND STUDY AIMS : Endoscopic ultrasound-guided through-the-needle biopsy (TTNB) of pancreatic cystic lesions (PCLs) is associated with a non-negligible risk for adverse events (AEs). We aimed to identify the hierarchic interaction among independent predictors for TTNB-related AEs and to generate a prognostic model using recursive partitioning analysis (RPA). PATIENTS AND METHODS : Multicenter retrospective analysis of 506 patients with PCLs who underwent TTNB. RPA of predictors for AEs was performed and the model was validated by means of bootstrap resampling. RESULTS : Mean cysts size was 36.7 mm. Most common diagnoses were intraductal papillary mucinous neoplasm (IPMN, 45 %), serous cystadenoma (18.8 %), and mucinous cystadenoma (12.8 %). Fifty-eight (11.5 %) AEs were observed. At multivariate analysis, age (odds ratio [OR] 1.32, 1.09-2.14; p = 0.05), number of TTNB passes (OR from 2.17, 1.32-4.34 to OR 3.16, 2.03-6.34 with the increase of the number of passes), complete aspiration of the cyst (OR 0.56, 0.31-0.95; p = 0.02), and diagnosis of IPMN (OR 4.16, 2.27-7.69; p < 0.001) were found to be independent predictors of AEs, as confirmed by logistic regression and random forest analyses. RPA identified three risk classes: high-risk (IPMN sampled with multiple microforceps passes, 28 % AEs rate), low-risk (1.4 % AE rate, including patients < 64 years with other-than-IPMN diagnosis sampled with ≤ 2 microforceps passes and with complete aspiration of the cyst) and middle-risk class (6.1 % AEs rate, including the remaining patients). CONCLUSION : TTNB should be selectively used in the evaluation of patients with IPMN. The present model could be applied during patient selection as to optimize the benefit/risk of TTNB.


Assuntos
Cisto Pancreático , Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Humanos , Neoplasias Intraductais Pancreáticas/patologia , Estudos Retrospectivos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Cisto Pancreático/patologia , Endossonografia/efeitos adversos , Neoplasias Pancreáticas/patologia
11.
Pancreatology ; 21(4): 805-811, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33745788

RESUMO

BACKGROUND: We aimed to assess factors impacting the endoscopic minor papilla sphincterotomy (EMPS) success rate, clinical efficacy, and safety in a large cohort of patients with symptomatic pancreas divisum (PD). METHODS: Retrospective study including patients with PD referred to the Pancreas Institute of Verona from May 2009 to May 2020 to undergo EMPS. The whole population was analyzed to assess EMPS technical success, defined as the rate of deep cannulation of the dorsal duct. Patients treated for recurrent pancreatitis (RP) with a minimum follow-up of 1 year were included to evaluate the clinical efficacy, defined as resolution or significant reduction of acute pancreatitis (AP) episodes. Safety was defined as the rate of procedure-related adverse events (AEs) according to an international lexicon. The effects of the main determinants on study outcomes were evaluated. RESULTS: Overall, 106 patients were evaluated. Technical success was obtained in 87 (82.1%). The presence of pancreatic calcifications was associated with failure (p < 0.0001). Clinical efficacy was evaluated in 59 patients. Resolution/reduction of AP episodes after EMPS was observed in 93% of patients over a median follow-up of 49 months (IQR 37-92). Smoking habit was associated with AP recurrence (p = 0.026). The overall AE rate was 14.9%, with post-ERCP pancreatitis as the most common complication (12.6%). CONCLUSIONS: In our study, performed at a tertiary center, EMPS showed satisfactory technical success and an acceptable safety profile. If confirmed by prospective multicenter studies, EMPS could become the standard of care for the treatment of RP in PD.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite Crônica , Doença Aguda , Cateterismo , Humanos , Pâncreas , Ductos Pancreáticos/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Esfinterotomia Endoscópica/efeitos adversos , Resultado do Tratamento
12.
Pancreatology ; 21(2): 443-450, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33390343

RESUMO

BACKGROUND/OBJECTIVES: Studies comparing EUS-guided fine-needle aspiration (EUS-FNA) with EUS-guided fine-needle biopsy (EUS-FNB) for the evaluation of pancreatic neuroendocrine tumors (pNETs) are lacking. We aimed at comparing EUS-FNA with EUS-FNB in terms of Ki-67 proliferative index (PI) estimation capability, cellularity of the samples, and reliability of Ki-67 PI/tumor grading compared with surgical specimens. METHODS: Patients diagnosed with pNETs on EUS and/or surgical specimens were retrospectively identified. Specimens were re-evaluated to assess Ki-67 PI feasibility, sample cellularity by manual counting, and determination of Ki-67 PI value. Outcomes in the EUS-FNA and EUS-FNB groups were compared. Kendall rank test was used for Ki-67 PI correlation between EUS and surgical specimens. Subgroup analysis including small (≤20 mm), non-functioning pNETs was performed. RESULTS: Three-hundred samples from 292 lesions were evaluated: 69 EUS-FNA cytology and 231 EUS-FNB histology. Ki-67 PI feasibility was similar for EUS-FNA and EUS-FNB (91.3% vs. 95.7%, p = 0.15), while EUS-FNB performed significantly better in the subgroup of 179 small pNETs (88.2% vs. 96.1%, p = 0.04). Rate of poor cellulated (<500 cells) specimens was equal between EUS-FNA and EUS-FNB. A significant correlation for Ki-67 PI values between EUS and 92 correspondent surgical specimens was found in both groups, but it was stronger with EUS-FNB (tau = 0.626, p < 0.0001 vs. tau = 0.452, p = 0.031). Correct grading estimation was comparable between the two groups (p = 0.482). CONCLUSION: Our study showed stronger correlation for Ki-67 values between EUS-FNB and surgical specimens, and that EUS-FNB outperformed EUS-FNA in the evaluation of small pNETs. EUS-FNB should become standard of care for grading assessment of suspected pNETs.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Biópsia por Agulha Fina/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Ultraschall Med ; 42(2): 167-177, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31597179

RESUMO

BACKGROUND AND STUDY AIMS: On contrast-enhanced imaging studies, nonhypovascular (i. e., isovascular and hypervascular) patterns can be observed in solid pancreatic lesions (SPLs) of different nature, prognosis, and management. We aimed to identify endoscopic ultrasound (EUS) features of nonhypovascular SPLs associated with malignancy/aggressiveness. The secondary aims were EUS tissue acquisition (EUS-TA) outcome and safety in this setting of patients. PATIENTS AND METHODS: This prospective observational study included patients with nonhypovascular SPLs detected on cross-sectional imaging and referred for EUS-TA. Lesion features (size, site, margins, echotexture, vascular pattern, and upstream dilation of the main pancreatic duct) were recorded. Malignancy/aggressiveness was determined by evidence of carcinoma at biopsy/surgical pathology, signs of aggressiveness (perineural invasion, lymphovascular invasion, and/or microscopic tumor extension/infiltration or evidence of metastatic lymph nodes) in the surgical specimen, radiologic detection of lymph nodes or distant metastases, and/or tumor growth > 5 mm/6 months. Uni- and multivariate analyses were performed to assess the primary aim. RESULTS: A total of 154 patients with 161 SPLs were enrolled. 40 (24.8 %) lesions were defined as malignant/aggressive. Irregular margins and size > 20 mm were independent factors associated with malignancy/aggressiveness (p < 0.001, OR = 5.2 and p = 0.003, OR = 2.1, respectively). However, size > 20 mm was not significant in the subgroup of other-than-neuroendocrine tumor (NET) lesions. The EUS-TA accuracy was 92 %, and the rate of adverse events was 4 %. CONCLUSION: Irregular margins on EUS are associated with malignancy/aggressiveness of nonhypovascular SPLs. Size > 20 mm should be considered a malignancy-related feature only in NET patients. EUS-TA is safe and highly accurate for differential diagnosis in this group of patients.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Endossonografia , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Prospectivos
14.
Gastrointest Endosc ; 92(3): 648-658.e2, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32433914

RESUMO

BACKGROUND AND AIMS: The aim of this study was to compare the performance of EUS-guided fine-needle biopsy using fork-tip or side-fenestrated needles in patients with solid pancreatic lesions. METHODS: A randomized controlled study was conducted in a single academic center on patients who underwent sampling with fork-tip or side-fenestrated 22-gauge or 25-gauge needles. Three passes were performed, each independently evaluated by a blinded pathologist and by endosonographers for macroscopic on-site evaluation (MOSE). The primary outcome was histologic yield; secondary aims were safety, diagnostic yield, sample quality, number of needle passes required to establish a diagnosis, and reliability of MOSE. RESULTS: One hundred ninety-two patients were enrolled. Both 22-gauge and 25-gauge fork-tip needles retrieved significantly higher rates of histologic samples than side-fenestrated needles (P < .013). Safety and diagnostic accuracy were comparable in the 2 arms, whereas sample quality (tissue integrity and blood contamination) was significantly better in the fork-tip group (P < .0001). The median number of diagnostic passes was lower using fork-tip needles (P = .054). The agreement between MOSE and pathologic evaluation was almost perfect in the fork-tip group and fair in the side-fenestrated group. CONCLUSIONS: Both needles showed equivalent safety and diagnostic accuracy. However, fork-tip needles provided a higher rate of extremely good-quality histologic samples and required fewer needle passes to reach a diagnosis. MOSE is a highly reliable tool when fork-tip needles are used compared with side-fenestrated needles. (Clinical trial registration number: NCT03622229.).


Assuntos
Agulhas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas , Reprodutibilidade dos Testes
15.
Scand J Gastroenterol ; 55(9): 1108-1113, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32684051

RESUMO

INTRODUCTION: After a failed percutaneous ultrasound (US)-guided sampling, it is recommended that endoscopic ultrasound (EUS)-guided tissue acquisition (TA) be performed for non-resectable solid pancreatic lesions according to the European Federation of Societies for Ultrasound in Medicine and Biology. However, the diagnostic performance of EUS-guided TA in this setting is unknown. METHODS: We retrospectively analyzed the performance and safety of EUS-guided TA in patients with a previous failed percutaneous biopsy. We also evaluated the diagnostic delays between the percutaneous approach and EUS diagnosis. RESULTS: Over a period of 2 years, 49 patients were identified (29 males, mean age 65 years). The reasons for failure of percutaneous sampling were inadequate samples in 25 (52.1%) cases and lesions that were not visible or targetable in 24 (47.9%) cases. In one case, EUS-guided TA was not performed because of the interposition of a metallic biliary stent. No adverse events were recorded for both the percutaneous and EUS approaches. The median diagnostic delay was 12 days. Overall, the sensitivity and accuracy of EUS-guided TA were 92.7 and 93.7%, respectively. A subgroup analysis examined cases with inadequate samples obtained with the percutaneous approach, and the sensitivity and accuracy of EUS-guided TA were 85.7 and 88%, respectively. CONCLUSION: EUS-guided TA is safe and accurate for the diagnosis of pancreatic lesions after a previous inconclusive percutaneous approach.


Assuntos
Diagnóstico Tardio , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Humanos , Masculino , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos
16.
J Infect Dis ; 220(12): 1935-1939, 2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31412121

RESUMO

We describe the establishment of a seronegative occult hepatitis B virus (HBV) infection (OBI) in a successfully vaccinated infant who underwent liver transplantation from an donor positive for antibody to hepatitis B core antigen (anti-HBc). The use of highly sensitive droplet digital polymerase chain reaction assays revealed a not negligible and transcriptionally active intrahepatic HBV reservoir (circular covalently closed DNA, relaxed circular DNA, and pregenomic RNA: 5.6, 2.4, and 1.1 copies/1000 cells, respectively), capable to sustain ongoing viral production and initial liver damage. Next-generation sequencing revealed a peculiar enrichment of hepatitis B surface antigen vaccine-escape mutations that could have played a crucial role in OBI transmission. This clinical case highlights the pathobiological complexity and the diagnostic challenges underlying OBI.


Assuntos
Vírus da Hepatite B/genética , Hepatite B/diagnóstico , Hepatite B/virologia , Transplante de Fígado , Mutação , Biomarcadores , Pré-Escolar , DNA Viral , Feminino , Hepatite B/etiologia , Hepatite B/prevenção & controle , Vírus da Hepatite B/imunologia , Humanos , Fígado/imunologia , Fígado/patologia , Fígado/virologia , Transplante de Fígado/efeitos adversos , Reação em Cadeia da Polimerase , Vacinação , Replicação Viral
17.
Liver Int ; 39(10): 1986-1998, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31172639

RESUMO

BACKGROUND & AIMS: We investigated the HCV-RNA amount, variability and prevalence of resistance-associated substitutions (RASs), in plasma, hepatic tumoral and non-tumoral tissue samples in patients undergoing liver-transplant/hepatic-resection (LT/HR), because of hepatocellular carcinoma and/or cirrhosis. METHODS: Eighteen HCV-infected patients undergoing LT/HR, 94.0% naïve to direct-acting antivirals (DAAs), were analysed. HCV-RNA was quantified in all compartments. NS3/NS5A/NS5B in plasma and/or in tumoral/non-tumoral tissues were analysed using Sanger and Ultra-deep pyrosequencing (UDPS, 9/18 patients). RASs prevalence, genetic-variability and phylogenetic analysis were evaluated. RESULTS: At the time of LT/HR, HCV-RNA was quantifiable in all compartments of DAA-naïve patients and was generally lower in tumoral than in non-tumoral tissues (median [IQR] = 4.0 [1.2-4.3] vs 4.3[3.1-4.9] LogIU/µg RNA; P = 0.193). The one patient treated with sofosbuvir + ribavirin represented an exception with HCV-RNA quantifiable exclusively in the liver, but with higher level in tumoral than in non-tumoral tissues (51 vs 7 IU/µg RNA). RASs compartmentalization was found by Sanger in 4/18 infected-patients, and by UDPS in other two patients. HCV-compartmentalization resulted to be associated with HBcAb-positivity (P = 0.013). UDPS showed approximately higher genetic-variability in NS3/NS5A sequences in all compartments. Phylogenetic-analysis showed defined and intermixed HCV-clusters among/within all compartments, and were strongly evident in the only non-cirrhotic patient, with plasma and non-tumoral sequences generally more closely related. CONCLUSIONS: Hepatic compartments showed differences in HCV-RNA amount, RASs and genetic variability, with a higher segregation within the tumoral compartment. HBV coinfection influenced the HCV compartmentalization. These results highlight HCV-strain diversifications within the liver, which could explain some of the failures occurring even today in the era of DAAs.


Assuntos
Antivirais/uso terapêutico , Farmacorresistência Viral/genética , Hepacivirus/genética , Hepatite C Crônica/tratamento farmacológico , Transplante de Fígado , Proteínas não Estruturais Virais/genética , Idoso , Carcinoma Hepatocelular/cirurgia , Coinfecção/tratamento farmacológico , Quimioterapia Combinada , Genótipo , Hepacivirus/efeitos dos fármacos , Hepatite B Crônica/tratamento farmacológico , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Filogenia , Ribavirina/uso terapêutico , Sofosbuvir/uso terapêutico , Resposta Viral Sustentada , Falha de Tratamento
18.
Medicina (Kaunas) ; 55(6)2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-31234437

RESUMO

Background and objectives: To enter the target cell, HIV-1 binds not only CD4 but also a co-receptor ß-chemokine receptor 5 (CCR5) or α chemokine receptor 4 (CXCR4). Limited information is available on the impact of co-receptor usage on HIV-1 replication in monocyte-derived macrophages (MDM) and on the homeostasis of this important cellular reservoir. Materials and Methods: Replication (measured by p24 production) of the CCR5-tropic 81A strain increased up to 10 days post-infection and then reached a plateau. Conversely, the replication of the CXCR4-tropic NL4.3 strain (after an initial increase up to day 7) underwent a drastic decrease becoming almost undetectable after 10 days post-infection. The ability of CCR5-tropic and CXCR4-tropic strains to induce cell death in MDM was then evaluated. While for CCR5-tropic 81A the rate of apoptosis in MDM was comparable to uninfected MDM, the infection of CXCR4-tropic NL4.3 in MDM was associated with a rate of 14.3% of apoptotic cells at day 6 reaching a peak of 43.5% at day 10 post-infection. Results: This suggests that the decrease in CXCR4-tropic strain replication in MDM can be due to their ability to induce cell death in MDM. The increase in apoptosis was paralleled with a 2-fold increase in the phosphorylated form of p38 compared to WT. Furthermore, microarray analysis showed modulation of proapoptotic and cancer-related genes induced by CXCR4-tropic strains starting from 24 h after infection, whereas CCR5 viruses modulated the expression of genes not correlated with apoptotic-pathways. Conclusions: In conclusion, CXCR4-tropic strains can induce a remarkable depletion of MDM. Conversely, MDM can represent an important cellular reservoir for CCR5-tropic strains supporting the role of CCR5-usage in HIV-1 pathogenesis and as a pharmacological target to contribute to an HIV-1 cure.


Assuntos
HIV-1/efeitos dos fármacos , HIV-1/crescimento & desenvolvimento , Compostos Heterocíclicos/farmacologia , Macrófagos/efeitos dos fármacos , Fármacos Anti-HIV/farmacologia , Benzilaminas , Ciclamos , Fragmentação do DNA/efeitos dos fármacos , HIV-1/isolamento & purificação , Humanos , Receptores CCR5/efeitos dos fármacos , Receptores CCR5/genética , Receptores CXCR4/efeitos dos fármacos , Receptores CXCR4/genética
19.
Appl Microbiol Biotechnol ; 102(23): 9925-9936, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30269214

RESUMO

The biology of HIV is rather complex due to high rate of replication, frequent recombination, and introduction of mutations. This gives rise to a number of distinct variants referred as quasispecies. In addition, the latency within reservoir allows the periodic reactivation of virus replication. The rapid replication of HIV allows immune response escape and establishment of resistance to therapy that can be acquired through drug selection and/or transmitted among individuals. This prompted, over the years, the development of a range of assays aimed to determine drug resistance and sensitivity, to be used both in clinical practice and in antiviral research. Reverse transcriptase (RT) inhibitors have an eminent place among the anti-HIV drugs, being constantly present from the beginning until today in the most commonly used antiviral regimens. This mini-review seeks to provide an up-to-date overview of recent efforts in developing even more reliable and simple methods, of both genotypic and phenotypic types, for specifically detecting drug resistance and sensitivity to RT inhibitors.


Assuntos
Testes Diagnósticos de Rotina , Farmacorresistência Viral Múltipla , HIV-1/efeitos dos fármacos , Inibidores da Transcriptase Reversa/farmacologia , Técnicas de Genotipagem , Infecções por HIV/tratamento farmacológico , HIV-1/fisiologia , Humanos , Replicação Viral
20.
Hepatobiliary Pancreat Dis Int ; 17(1): 70-74, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29428108

RESUMO

BACKGROUND: Early detection of small solid pancreatic lesions is increasingly common. To date, few and contradictory data have been published about the relationship between lesion size and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) diagnostic yield. The aim of this study was to assess the relation between the size of solid pancreatic lesions and the diagnostic yield of EUS-FNA using a 25-gauge needle in a center without available rapid on-site evaluation. METHODS: In the retrospective cohort study, we selected patients who underwent EUS-FNA for solid pancreatic lesions with a 25-gauge needle from October 2014 to October 2015. Patients were divided into three groups (≤15 mm, 16-25 mm and >25 mm), and the outcomes were compared. RESULTS: We analyzed 163 patients. Overall adequacy, sensitivity, specificity and accuracy were 85.2%, 81.8%, 93.7%, and 80.4%, respectively. When stratified by size, the sensitivity and accuracy correlated with size (P = 0.016 and P = 0.042, respectively). Multivariate analysis showed that lesion size was the only independent factor (P = 0.019, OR = 4.76) affecting accuracy. The role of size as an independent factor affecting accuracy was confirmed in a separate multivariate analysis, where size was included in the model as a covariate (P = 0.018, OR = 1.08). CONCLUSION: Our study demonstrates that, in the absence of rapid on-site evaluation, mass size affects the accuracy of EUS-FNA of solid pancreatic lesions.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Neoplasias Pancreáticas/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Carga Tumoral , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA