Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 118(13): 135001, 2017 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-28409959

RESUMO

We present narrow-band self-emission x-ray images from a titanium tracer layer placed at the fuel-shell interface in 60-laser-beam implosion experiments at the OMEGA facility. The images are acquired during deceleration with inferred convergences of ∼9-14. Novel here is that a systematically observed asymmetry of the emission is linked, using full sphere 3D implosion modeling, to performance-limiting low mode asymmetry of the drive.

2.
Phys Rev Lett ; 112(15): 155003, 2014 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-24785044

RESUMO

We present a new approach to equation of state experiments that utilizes a laser-driven shock and release technique combined with spatially resolved x-ray Thomson scattering, radiography, velocity interferometry, and optical pyrometry to obtain independent measurements of pressure, density, and temperature for carbon at warm dense matter conditions. The uniqueness of this approach relies on using a laser to create very high initial pressures to enable a very deep release when the shock moves into a low-density pressure standard. This results in material at near normal solid density and temperatures around 10 eV. The spatially resolved Thomson scattering measurements facilitate a temperature determination of the released material by isolating the scattering signal from a specific region in the target. Our results are consistent with quantum molecular dynamics calculations for carbon at these conditions and are compared to several equation of state models.

3.
Rev Sci Instrum ; 89(10): 10F102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399823

RESUMO

X-ray diffraction measurements to characterize phase transitions of dynamically compressed high-Z matter at Mbar pressures require both sufficient photon energy and fluence to create data with high fidelity in a single shot. Large-scale laser systems can be used to generate x-ray sources above 10 keV utilizing line radiation of mid-Z elements. However, the laser-to-x-ray energy conversion efficiency at these energies is low, and thermal x-rays or hot electrons result in unwanted background. We employ polycapillary x-ray lenses in powder x-ray diffraction measurements using solid target x-ray emission from either the Z-Beamlet long-pulse or the Z-Petawatt (ZPW) short-pulse laser systems at Sandia National Laboratories. Polycapillary lenses allow for a 100-fold fluence increase compared to a conventional pinhole aperture while simultaneously reducing the background significantly. This enables diffraction measurements up to 16 keV at the few-photon signal level as well as diffraction experiments with ZPW at full intensity.

4.
Artigo em Inglês | MEDLINE | ID: mdl-25314547

RESUMO

We present recent results of equation-of-state (EOS) measurements of shocked silica (SiO_{2}) aerogel foam at the OMEGA laser facility. Silica aerogel is an important low-density pressure standard used in many high energy density experiments, including the novel technique of shock and release. Due to its many applications, it has been a heavily studied material and has a well-known Hugoniot curve. This work then complements the velocity and pressure measurements with additional temperature data providing the full EOS information within the warm dense matter regime for the temperature interval of 1-15 eV and shock velocities between 10 and 40 km/s corresponding to shock pressures of 0.3-2 Mbar. The experimental results were compared with hydrodynamic simulations and EOS models. We found that the measured temperature was systematically lower than suggested by theoretical calculations. Simulations provide a possible explanation that the emission measured by optical pyrometry comes from a radiative precursor rather than from the shock front, which could have important implications for such measurements.


Assuntos
Teste de Materiais , Pressão , Dióxido de Silício/química , Temperatura , Géis , Interferometria , Lasers
5.
Rev Sci Instrum ; 83(10): 10E108, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126930

RESUMO

In many laboratory astrophysics experiments, intense laser irradiation creates novel material conditions with large, one-dimensional gradients in the temperature, density, and ionization state. X-ray Thomson scattering is a powerful technique for measuring these plasma parameters. However, the scattered signal has previously been measured with little or no spatial resolution, which limits the ability to diagnose inhomogeneous plasmas. We report on the development of a new imaging x-ray Thomson spectrometer (IXTS) for the Omega laser facility. The diffraction of x-rays from a toroidally curved crystal creates high-resolution images that are spatially resolved along a one-dimensional profile while spectrally dispersing the radiation. This focusing geometry allows for high brightness while localizing noise sources and improving the linearity of the dispersion. Preliminary results are presented from a scattering experiment that used the IXTS to measure the temperature profile of a shocked carbon foam.

6.
Rev Sci Instrum ; 79(10): 10F305, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044618

RESUMO

The newly upgraded TRIDENT high-energy-density (HED) facility provides high-energy short-pulse laser-matter interactions with powers in excess of 200 TW and energies greater than 120 J. In addition, TRIDENT retains two long-pulse (nanoseconds to microseconds) beams that are available for simultaneous use in either the same experiment or a separate one. The facility's flexibility is enhanced by the presence of two separate target chambers with a third undergoing commissioning. This capability allows the experimental configuration to be optimized by choosing the chamber with the most advantageous geometry and features. The TRIDENT facility also provides a wide range of standard instruments including optical, x-ray, and particle diagnostics. In addition, one chamber has a 10 in. manipulator allowing OMEGA and National Ignition Facility (NIF) diagnostics to be prototyped and calibrated.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA