Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BMC Musculoskelet Disord ; 16: 375, 2015 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-26634830

RESUMO

BACKGROUND: Aim of this prospective study was to evaluate mid-term clinical and radiographic outcomes in total hip arthroplasty using an acetabular cup made of an innovative biomaterial, Trabecular Titanium™, whose highly porous structure and mechanical properties have been designed to mimic those of the natural bone, thus promoting a more physiological load transfer and a more durable fixation. METHODS: Between September 2007 and November 2009, 134 total hip replacements and eight revisions were carried out using DELTA-TT primary cups (Lima Corporate, Villanova di San Daniele del Friuli, Italy) in 133 consecutive patients. Mean age was 57.5 ± 14.7 SD (18-92) years. Diagnosis was primarily hip osteoarthritis in 85 (63 %) cases, developmental dysplasia of the hip (DDH) in 24 (18 %) and hip avascular necrosis (AVN) in 10 (7 %). All the revision procedures were due to aseptic loosening of the original implant. Approval of the Institutional Review Board of the IRCCS Policlinico San Matteo in Pavia was obtained for this study. RESULTS: Mean follow-up was 72.7 ± 7.9 SD (60-86) months. Average Harris Hip Score (HHS) significantly increased from 44.2 ± 5.4 SD (35-52) preoperatively to 95.9 ± 3.5 SD (88-100) at the last follow-up. No major post-operative complications were observed. 99.3 % of the acetabular components were radiographically stable at the last follow-up, without any radiolucent lines, sclerotic areas or periprosthetic osteolysis. Kaplan-Meier survival rate was 99.3 % at 5 years (95 % confidence interval). CONCLUSIONS: This first account on the mid-term clinical performance of the DELTA-TT cup shows primary and secondary stability, thus representing an optimal solution for patients with high demands or affected by severe hip conditions.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Titânio , Adulto Jovem
2.
J Arthroplasty ; 30(10): 1747-51, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25980775

RESUMO

Between October 2001 and December 2010, 143 patients with developmental dysplasia underwent hip arthroplasty surgery using a conical stem with modular necks (MODULUS system, Lima Corporate, Villanova di San Daniele del Friuli, Italy). Thirty (21.0%) patients had both hips replaced, for a total of 173 implants. The mean age at the time of surgery was 55 years (range: 22-81 years). The mean follow-up was 87 months (range: 36-146 months); average Harris Hip Score increased from 42 (range: 23-65) preoperatively to 92 (range: 76-100) at the last follow-up. Stem revision was required in two cases. The MODULUS stem showed good long-term clinical and radiographic results, with a Kaplan-Meier survivorship of 97.6% (95% CI: 94.8-100.0%) at 8 years.


Assuntos
Artroplastia de Quadril/instrumentação , Luxação Congênita de Quadril/cirurgia , Prótese de Quadril/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Feminino , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Reoperação , Análise de Sobrevida , Adulto Jovem
3.
Hip Int ; 28(2_suppl): 73-77, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30755114

RESUMO

BACKGROUND:: The new double-conical tapered stem is a novel cementless modular system, which is indicated for both primary and revision surgeries. It has been designed with different angles at the proximal (5°) and distal sections (1° 36') in order to obtain optimal fixation by proximal and distal fit and fill of the femoral canal. AIM:: The aim of this prospective study was to evaluate the short-term clinical and radiographic outcomes of primary and revision hip surgery with the new double-conical stem. METHODS:: 61 stems were implanted (December 2013 to September 2016) in 42 cases of primary and in 19 cases of revision surgery. The mean age of patients was 64.7 (17-94; standard deviation [SD] 21.9) years. RESULTS:: The mean body mass index of the patients was 24.6 (17-34.6). In 3 cases of developmental dysplasia of the hip we performed femoral shortening osteotomy. The mean follow-up was 26 (8-40) months. 3 patients died due to causes unrelated to surgery. Postoperative complications included 3 hip dislocations, 2 infections and 1 case of stem explant for metastatic tumour. For all other cases, at the last follow-up radiographs showed no loosening, no radiolucent lines nor subsidence. The mean Harris Hip Score significantly improved from 45 (range 35-58) preoperatively to 87 (range 75-94). Leg length discrepancy was found in 10% of cases but never >1 cm. CONCLUSIONS:: Radiographic analysis showed the bone-stem contact full at 2 levels of taper. The double-tapered prosthetic stem can therefore be usefully employed both in primary and in revision surgeries.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fêmur/cirurgia , Prótese de Quadril , Desigualdade de Membros Inferiores/cirurgia , Osteoartrite do Quadril/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Desigualdade de Membros Inferiores/diagnóstico , Desigualdade de Membros Inferiores/etiologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Reoperação , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA