Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
J Allergy Clin Immunol ; 141(4): 1231-1238.e1, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28736267

RESUMO

BACKGROUND: We and others have shown that the gamma tocopherol (γT) isoform of vitamin E has multiple anti-inflammatory and antioxidant actions and that γT supplementation reduces eosinophilic and endotoxin (LPS)-induced neutrophilic airway inflammation in animal models and healthy human volunteers. OBJECTIVE: We sought to determine whether γT supplementation reduces eosinophilic airway inflammation and acute neutrophilic response to inhaled LPS challenge in volunteers with asthma. METHODS: Participants with mild asthma were enrolled in a double-blinded, placebo-controlled crossover study to assess the effect of 1200 mg of γT daily for 14 days on sputum eosinophils, mucins, and cytokines. We also assessed the effect on acute inflammatory response to inhaled LPS challenge following γT treatment, focusing on changes in sputum neutrophilia, mucins, and cytokines. Mucociliary clearance was measured using gamma scintigraphy. RESULTS: Fifteen subjects with mild asthma completed both arms of the study. Compared with placebo, γT notably reduced pre-LPS challenge sputum eosinophils and mucins, including mucin 5AC and reduced LPS-induced airway neutrophil recruitment 6 and 24 hours after challenge. Mucociliary clearance was slowed 4 hours postchallenge in the placebo group but not in the γT treatment group. Total sputum mucins (but not mucin 5AC) were reduced at 24 hours postchallenge during γT treatment compared with placebo. CONCLUSIONS: When compared with placebo, γT supplementation for 14 days reduced inflammatory features of asthma, including sputum eosinophils and mucins, as well as acute airway response to inhaled LPS challenge. Larger scale clinical trials are needed to assess the efficacy of γT supplements as a complementary or steroid-sparing treatment for asthma.


Assuntos
Asma/tratamento farmacológico , Endotoxinas/efeitos adversos , Eosinofilia/tratamento farmacológico , Eosinófilos/efeitos dos fármacos , Infiltração de Neutrófilos/efeitos dos fármacos , Vitaminas/uso terapêutico , gama-Tocoferol/uso terapêutico , Adulto , Asma/imunologia , Asma/metabolismo , Biomarcadores/metabolismo , Estudos Cross-Over , Método Duplo-Cego , Esquema de Medicação , Endotoxinas/administração & dosagem , Endotoxinas/imunologia , Eosinofilia/metabolismo , Eosinófilos/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucinas/metabolismo , Escarro/efeitos dos fármacos , Escarro/metabolismo , Resultado do Tratamento , Vitaminas/farmacologia , gama-Tocoferol/farmacologia
2.
Am J Respir Crit Care Med ; 192(2): 182-90, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25909230

RESUMO

RATIONALE: Chronic bronchitis (CB) is characterized by persistent cough and sputum production. Studies were performed to test whether mucus hyperconcentration and increased partial osmotic pressure, in part caused by abnormal purine nucleotide regulation of ion transport, contribute to the pathogenesis of CB. OBJECTIVES: We tested the hypothesis that CB is characterized by mucus hyperconcentration, increased mucus partial osmotic pressures, and reduced mucus clearance. METHODS: We measured in subjects with CB as compared with normal and asymptomatic smoking control subjects indices of mucus concentration (hydration; i.e., percentage solids) and sputum adenine nucleotide/nucleoside concentrations. In addition, sputum partial osmotic pressures and mucus transport rates were measured in subjects with CB. MEASUREMENTS AND RESULTS: CB secretions were hyperconcentrated as indexed by an increase in percentage solids and total mucins, in part reflecting decreased extracellular nucleotide/nucleoside concentrations. CB mucus generated concentration-dependent increases in partial osmotic pressures into ranges predicted to reduce mucus transport. Mucociliary clearance (MCC) in subjects with CB was negatively correlated with mucus concentration (percentage solids). As a test of relationships between mucus concentration and disease, mucus concentrations and MCC were compared with FEV1, and both were significantly correlated. CONCLUSIONS: Abnormal regulation of airway surface hydration may slow MCC in CB and contribute to disease pathogenesis.


Assuntos
Bronquite Crônica/fisiopatologia , Depuração Mucociliar/fisiologia , Muco/química , Muco/fisiologia , Pressão Osmótica/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Aerosol Med Pulm Drug Deliv ; 37(4): 167-170, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38687136

RESUMO

Background: Recent studies show e-cigarette (EC) users have increased rates of chronic bronchitic symptoms that may be associated with depressed mucociliary clearance (MCC). Little is known about the acute or chronic effects of EC inhalation on in vivo MCC. Methods: In vivo MCC was measured in young adult vapers (n = 5 males, mean age = 21) after controlled inhalation of a radiolabeled (Tc99m sulfur colloid) aerosol. Whole-lung clearance of radiolabeled deposited particles was measured over a 90-minute period for baseline MCC and associated with controlled periodic vaping over the first 60 minutes of MCC measurements. The vaping challenge was administered from a fourth generation box mod EC containing unflavored e-liquid (65% propylene glycol/35% vegetable glycerin, 3 mg/mL freebase nicotine). The challenge was administered at the start of each 10-minute interval of MCC measurements and consisted of 1 puff every 30 seconds for 5 minutes (i.e., 10 puffs for each 10-minute period for a total of 60 puffs during the initial 60 minutes of MCC measurements). Results: Compared with baseline, peripheral lung average clearance (%) over the 90 minutes of MCC measures was enhanced, associated with EC challenge, 12 (±6) versus 24 (±6), respectively (p < 0.05 by Wilcoxon signed-rank test). Conclusions: Acute enhancement of in vivo MCC during EC challenge is contrary to recent studies showing nicotine-associated slowing of ciliary beat and mucus transport at higher nicotine levels than those used here. However, our findings are consistent with an acute increase in fluid volume and mucin secretion to the bronchial airway surface that is likely short lived. Research reported in this publication was supported by the National Institutes of Health R01HL139369 and registered with ClinicalTrials.gov (NCT03700892).


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Pulmão , Depuração Mucociliar , Nicotina , Vaping , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Administração por Inalação , Aerossóis , Glicerol/administração & dosagem , Pulmão/metabolismo , Pulmão/fisiopatologia , Depuração Mucociliar/efeitos dos fármacos , Nicotina/administração & dosagem , Nicotina/farmacocinética , Nicotina/efeitos adversos , Propilenoglicol/administração & dosagem , Coloide de Enxofre Marcado com Tecnécio Tc 99m/administração & dosagem , Fatores de Tempo , Vaping/efeitos adversos
5.
J Cyst Fibros ; 23(3): 457-460, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38355350

RESUMO

Many people with CF (pwCF) desire a reduction in inhaled treatment burden after initiation of elexacaftor/tezacaftor/ivacaftor. The randomized, open-label SIMPLIFY study showed that discontinuing hypertonic saline (HS) or dornase alfa (DA) was non-inferior to continuation of each treatment with respect to change in lung function over a 6-week period. In this SIMPLIFY substudy, we used gamma scintigraphy to determine whether discontinuation of either HS or DA was associated with deterioration in the rate of in vivo mucociliary clearance (MCC) in participants ≥12 years of age. While no significant differences in MCC endpoints were associated with HS discontinuation, significant improvement in whole and peripheral lung MCC was observed after discontinuing DA. These results suggest that pwCF on ETI with mild lung disease do not experience a subclinical deterioration in MCC that could later impact health outcomes after discontinuing HS, and in fact may benefit from improved MCC after stopping DA treatment.


Assuntos
Aminofenóis , Benzodioxóis , Fibrose Cística , Desoxirribonuclease I , Indóis , Depuração Mucociliar , Pirazóis , Quinolonas , Humanos , Fibrose Cística/tratamento farmacológico , Fibrose Cística/fisiopatologia , Depuração Mucociliar/efeitos dos fármacos , Masculino , Benzodioxóis/uso terapêutico , Feminino , Solução Salina Hipertônica/administração & dosagem , Aminofenóis/uso terapêutico , Desoxirribonuclease I/uso terapêutico , Desoxirribonuclease I/administração & dosagem , Indóis/uso terapêutico , Quinolonas/uso terapêutico , Adulto , Adolescente , Pirazóis/uso terapêutico , Proteínas Recombinantes/administração & dosagem , Pirróis/administração & dosagem , Resultado do Tratamento , Piridinas/uso terapêutico , Adulto Jovem , Agonistas dos Canais de Cloreto/uso terapêutico , Combinação de Medicamentos , Criança , Testes de Função Respiratória , Pirrolidinas
6.
J Cyst Fibros ; 23(1): 155-160, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37845149

RESUMO

BACKGROUND: The cystic fibrosis transmembrane conductance regulator (CFTR) modulator elexacaftor/tezacaftor/ivacaftor (E/T/I) is highly effective clinically for those with at least one F508del-CFTR allele. The effects of E/T/I on mucociliary clearance (MCC) and sputum properties are unknown. We, therefore, sought to characterize the effects of E/T/I on in vivo MCC and sputum characteristics hypothesized to impact mucus transport. METHODS: Forty-four participants ≥12 years of age were enrolled into this prospective, observational trial prior to initiation of E/T/I and had baseline measurement of MCC and characterization of induced sputum and exhaled breath condensate (EBC) samples. Study procedures were repeated after 1 month of E/T/I treatment. RESULTS: Average age was 27.7 years with baseline forced expiratory volume in 1 second (FEV1) of 78.2 % predicted. 52 % of subjects had previously been treated with a 2-drug CFTR modulator combination. The average whole lung MCC rate measured over 60 min (WLAveClr60) significantly improved from baseline to post-E/T/I (14.8 vs. 22.8 %; p = 0.0002), as did other MCC indices. Sputum% solids also improved (modeled mean 3.4 vs. 2.2 %; p<0.0001), whereas non-significant reductions in sputum macrorheology (G', G") were observed. No meaningful changes in exhaled breath condensate endpoints (sialic acid:urea ratio, pH) were observed. CONCLUSIONS: E/T/I improved the hydration of respiratory secretions (% solids) and markedly accelerated MCC. These data confirm the link between CFTR function, mucus solid content, and MCC and help to define the utility of MCC and mucus-related bioassays in future efforts to restore CFTR function in all people with CF.


Assuntos
Fibrose Cística , Indóis , Pirazóis , Piridinas , Pirrolidinas , Quinolonas , Humanos , Adulto , Fibrose Cística/diagnóstico , Fibrose Cística/tratamento farmacológico , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística , Depuração Mucociliar , Estudos Prospectivos , Aminofenóis/uso terapêutico , Benzodioxóis/uso terapêutico , Muco , Mutação , Agonistas dos Canais de Cloreto/uso terapêutico
7.
FASEB J ; 26(2): 533-45, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21990373

RESUMO

Cigarette smoke (CS) exposure induces mucus obstruction and the development of chronic bronchitis (CB). While many of these responses are determined genetically, little is known about the effects CS can exert on pulmonary epithelia at the protein level. We, therefore, tested the hypothesis that CS exerts direct effects on the CFTR protein, which could impair airway hydration, leading to the mucus stasis characteristic of both cystic fibrosis and CB. In vivo and in vitro studies demonstrated that CS rapidly decreased CFTR activity, leading to airway surface liquid (ASL) volume depletion (i.e., dehydration). Further studies revealed that CS induced internalization of CFTR. Surprisingly, CS-internalized CFTR did not colocalize with lysosomal proteins. Instead, the bulk of CFTR shifted to a detergent-resistant fraction within the cell and colocalized with the intermediate filament vimentin, suggesting that CS induced CFTR movement into an aggresome-like, perinuclear compartment. To test whether airway dehydration could be reversed, we used hypertonic saline (HS) as an osmolyte to rehydrate ASL. HS restored ASL height in CS-exposed, dehydrated airway cultures. Similarly, inhaled HS restored mucus transport and increased clearance in patients with CB. Thus, we propose that CS exposure rapidly impairs CFTR function by internalizing CFTR, leading to ASL dehydration, which promotes mucus stasis and a failure of mucus clearance, leaving smokers at risk for developing CB. Furthermore, our data suggest that strategies to rehydrate airway surfaces may provide a novel form of therapy for patients with CB.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Pulmão/metabolismo , Fumar/efeitos adversos , Fumar/metabolismo , Adulto , Idoso , Animais , Sequência de Bases , Transporte Biológico Ativo , Água Corporal/metabolismo , Bronquite Crônica/etiologia , Bronquite Crônica/metabolismo , Estudos de Casos e Controles , Células Cultivadas , Cricetinae , Fibrose Cística/etiologia , Fibrose Cística/metabolismo , Fibrose Cística/terapia , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Primers do DNA/genética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Depuração Mucociliar , Mucosa Respiratória/metabolismo , Solução Salina Hipertônica/farmacologia , Fumaça/efeitos adversos , Solubilidade
8.
Infect Control Hosp Epidemiol ; 44(9): 1481-1484, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36912322

RESUMO

BACKGROUND: Face masks reduce disease transmission by protecting the wearer from inhaled pathogens and reducing the emission of infectious aerosols. Although methods quantifying efficiency for wearer protection are established, current methods for assessing face mask containment efficiency rely on measurement of a low concentration of aerosols emitted from an infected or noninfected individual. METHODS: A small port enabled the introduction of 0.05 µm sodium chloride particles at a constant rate behind the mask worn by a study participant. A condensation particle counter monitored ambient particle numbers 60 cm in front of the participant over 3-minute periods of rest, speaking, and coughing. The containment efficiency (%) for each mask and procedure was calculated as follows: 100 × (1 - average ambient concentration with face covering worn/average ambient concentration with a sham face covering in place). The protection efficiency (%) was also measured using previously published methods. The probability of transmission (%) from infected to uninfected (a function of both the containment efficiency and the protection efficiency) was calculated as follows: {1 - (containment efficiency/100)}×{1 - (protection efficiency/100)}×100. RESULTS: The average containment efficiencies for each mask over all procedures and repeated measures were 94.6%, 60.9%, 38.8%, and 43.2%, respectively, for the N95 mask, the KN95 mask, the procedure face mask, and the gaiter. The corresponding protection efficiencies for each mask were 99.0%, 63.7%, 45.3%, and 24.2%, respectively. For example, the transmission probability for 1 infected and 1 uninfected individual in close proximity was ∼14.2% for KN95 masks, compared to 36%-39% when only 1 individual wore a KN95 mask. CONCLUSION: Overall, we detected a good correlation between the protection and containment that a face covering afforded to a wearer.


Assuntos
Aerossóis e Gotículas Respiratórios , Dispositivos de Proteção Respiratória , Humanos , Respiradores N95 , Máscaras , Tosse
9.
J Aerosol Med Pulm Drug Deliv ; 35(5): 286-290, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36095164

RESUMO

Experiments designed to image in vivo deposition of radiolabel-drug mixtures are useful for estimating inhaled drug delivery and for assessing bioequivalence of delivery devices. Validation of the radiolabel-drug mixture is vital to ensure that subsequent imaging is reflective of drug deposition. Application of gamma attenuation corrections allows both total and regional lung deposition of drug to be estimated by two-dimensional (2D) imaging. Imaging methods are also useful for measuring in vivo mucociliary clearance (MC) function. Such measures allow assessment of the efficacy of drugs designed to improve clearance of airway secretions in airway disease. MC rates can be measured by controlled inhalation and gamma camera monitoring of radiolabeled aerosols containing non-permeating tracers. While in vivo MC rates reflect the function of the mucociliary apparatus, they are also dependent on regional deposition patterns of the inhaled aerosol.


Assuntos
Pulmão , Depuração Mucociliar , Administração por Inalação , Aerossóis , Pulmão/diagnóstico por imagem
10.
Compr Physiol ; 12(4): 3823-3832, 2022 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-35959754

RESUMO

Total and regional deposition of inhaled electronic cigarette (E-cig) particles in the respiratory tract (RT) depends on both physical properties of the inhaled particles and biological factors of users, for example, breathing pattern or puff profile, airway anatomy, and regional ventilation. Accurate particle sizing of E-cig aerosols is essential for predicting particle deposition in the RT. Studies using a variety of sizing methods have shown mass median aerodynamic diameters ranging from 0.2 to 1.2 um and secondary count diameters in the ultrafine range (<0.1 µm). Incorporating these particle sizes into a multiple-path particle dosimetry (MPPD) model shows 10% to 45% total lung deposition by mass and 30% to 80% for ultrafine particles depending on the breathing patterns. These predictions are consistent with experimental measures of deposition fraction of submicron and ultrafine particles. While box-mod-type E-cig devices allow for full "direct-lung" inhalations of aerosol, the more recent pod-based, and disposable E-cigs (e.g., JUUL, Puff Bar, Stig) deliver the aerosol as a "mouth-to-lung" puff, or bolus, that is inhaled early in the breath followed to various degrees by further inhalation of ambient air. Measurement of realistic ventilation patterns associated with these various devices may further improve deposition predictions. Finally, while in vivo measures of RT deposition present a challenge, a recent methodology to radiolabel E-cig particles may allow for such measurements by gamma scintigraphy. Supported by NIH/NHLBI R01HL139369. © 2022 American Physiological Society. Compr Physiol 12: 1-10, year.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Administração por Inalação , Aerossóis , Humanos , Pulmão/diagnóstico por imagem , Material Particulado , Sistema Respiratório/diagnóstico por imagem
11.
J Cyst Fibros ; 21(1): 143-145, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34083123

RESUMO

CFTR function is required for normal mucociliary clearance (MCC) and cough-assisted clearance (CC). Lumacaftor-ivacaftor is approved for use in people with cystic fibrosis (CF) carrying two copies of F508del-CFTR. In this observational study performed at four study sites, we characterized the effect of lumacaftor-ivacaftor on mucociliary and cough clearance and related this to other clinical and research endpoints after one month of treatment. Twenty-five adolescents and adults were enrolled. No effect on whole lung MCC was observed, but CC was significantly increased. Sweat chloride improved by 18 mEq/L in this group, indicating a modest restoration of CFTR activity, but no demonstrable change in FEV1 or lung clearance index was observed. We speculate that the modest effect of lumacaftor-ivacaftor on CFTR function was insufficient to yield an improvement in MCC.


Assuntos
Aminofenóis/uso terapêutico , Aminopiridinas/uso terapêutico , Benzodioxóis/uso terapêutico , Fibrose Cística/tratamento farmacológico , Depuração Mucociliar/efeitos dos fármacos , Quinolonas/uso terapêutico , Adolescente , Adulto , Criança , Agonistas dos Canais de Cloreto/uso terapêutico , Estudos de Coortes , Regulador de Condutância Transmembrana em Fibrose Cística/uso terapêutico , Combinação de Medicamentos , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
12.
J Aerosol Med Pulm Drug Deliv ; 34(5): 269-273, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34435873

RESUMO

This chapter describes the effects that respiratory disease has on particle deposition in the lungs. The geometry of airways, breathing patterns, and regional ventilation are all affected by various lung diseases, including COPD, asthma, and cystic fibrosis, and in turn modify total and regional deposition from normal. Total particle deposition in the lung is increased by airways obstruction and increased ventilation at rest compared to healthy individuals. Regional particle deposition is 1) shifted from distal to more proximal bronchial airways by airway obstruction, and 2) becomes more heterogeneous due to uneven lung ventilation. The net effect of the changes in total and regional particle deposition from normal is to greatly enhance bronchial airway surface doses for particle deposition while leaving unventilated lung regions inaccessible to the particles. As a result, both therapeutic aerosol delivery and the adverse effects of pollutant particles may be altered with progression of lung disease.


Assuntos
Asma , Pulmão , Administração por Inalação , Aerossóis/uso terapêutico , Asma/tratamento farmacológico , Humanos , Tamanho da Partícula
13.
ERJ Open Res ; 7(2)2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34109248

RESUMO

BACKGROUND: Impaired mucus clearance and airway mucus plugging have been shown to occur in moderate-severe asthma, especially during acute exacerbations. In cystic fibrosis, where airway mucus is dehydrated, it has been shown that inhaled hypertonic saline (HS) produces both acute and sustained enhancement of mucociliary clearance (MCC). The current study was designed to assess the acute and sustained effect of inhaled 7% HS on MCC in adult asthma. METHODS: Well-controlled, moderate-severe female asthmatic patients (n=8) were screened with a single test dose of albuterol (four puffs by metered-dose inhaler) followed by HS (7% sodium chloride, 4 mL using PARI LC Star nebuliser). Spirometry was measured pre-treatment and 5 and 30 min post-treatment for safety. MCC was measured using γ-scintigraphy on three separate visits: at baseline, during inhalation and 4 h after a single dose of HS. RESULTS: MCC was acutely enhanced during HS treatment; mean±sd clearance over 60 min of dynamic imaging (Ave60Clr) was 8.9±7.9% (baseline) versus 23.4±7.6% (acute HS) (p<0.005). However, this enhancement was not maintained over a 4-h period where post-HS treatment Ave60Clr was 9.3±8.2%. In this small cohort we found no decrements in lung function up to 30 min post-treatment (forced expiratory volume in 1 s 97.4±10.0% predicted pre-treatment and 98.9±10.7% predicted 30 min post-treatment). CONCLUSION: While MCC was rapidly enhanced during 7% HS treatment there was no effect on MCC at 4 h post-treatment. While these findings may not support aerosolised HS use for maintenance therapy, they do suggest a benefit of treating acute exacerbations in patients with moderate-severe asthma.

14.
J Expo Sci Environ Epidemiol ; 31(6): 953-960, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34006963

RESUMO

BACKGROUND: Globally, a large percentage of men keep a beard at least occasionally. Workplace regulations prohibit beards with N95 respirators, but there is little information on the effect of beards with face masks worn by the public for protection against SARS-CoV-2. METHODS AND FINDINGS: We examined the fitted filtration efficiency (FFE) of five commonly worn protective face masks as a function of beard length following the US Occupational Safety and Health Administration Quantitative Fit Test: N95 (respirator), KF94 and KN95, surgical/procedure, and cloth masks. A comparison using N95 respirators was carried out in shaven and bearded men. A detailed examination was conducted for beard lengths between 0 and 10 mm (0.5 mm increments). The effect of an exercise band covering the beard on FFE was also tested. Although N95 respirators showed considerable variability among bearded men, they had the highest FFE for beard lengths up to 10 mm. KF94 and KN95 masks lost up to 40% of their FFE. Procedure and cotton masks had poor performance even on bare skin (10-30% FFE) that did not change appreciably with beard length. Marked performance improvements were observed with an exercise band worn over the beard. CONCLUSIONS: Though variable, N95 respirators offer the best respiratory protection for bearded men. While KF94 and KN95 FFE is compromised considerably by increasing beard length, they proved better options than procedure and cotton face masks. A simple exercise band improves FFE for face masks commonly used by bearded men during the COVID-19 pandemic.


Assuntos
COVID-19 , Dispositivos de Proteção Respiratória , Humanos , Masculino , Máscaras , Pandemias/prevenção & controle , Equipamento de Proteção Individual , SARS-CoV-2
15.
Am J Infect Control ; 49(9): 1206-1209, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33971283

RESUMO

Shortages of efficient filtering facepiece respirators leave the public vulnerable to transmission of infectious diseases in small particle aerosols. This study demonstrates that a high-filtration-efficiency facepiece capable of filtering out >95% of 0.05µm particles while being worn can be simply produced with available materials.


Assuntos
Exposição Ocupacional , Dispositivos de Proteção Respiratória , Aerossóis , Filtração , Humanos , Ventiladores Mecânicos
16.
JAMA Intern Med ; 181(4): 463-469, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33300948

RESUMO

Importance: During the coronavirus disease 2019 (COVID-19) pandemic, the general public has been advised to wear masks or improvised face coverings to limit transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, there has been considerable confusion and disagreement regarding the degree to which masks protect the wearer from airborne particles. Objectives: To evaluate the fitted filtration efficiency (FFE) of various consumer-grade and improvised face masks, as well as several popular modifications of medical procedure masks that are intended to improve mask fit or comfort. Design, Setting, and Participants: For this study conducted in a research laboratory between June and August 2020, 7 consumer-grade masks and 5 medical procedure mask modifications were fitted on an adult male volunteer, and FFE measurements were collected during a series of repeated movements of the torso, head, and facial muscles as outlined by the US Occupational Safety and Health Administration Quantitative Fit Testing Protocol. The consumer-grade masks tested included (1) a 2-layer nylon mask with ear loops that was tested with an optional aluminum nose bridge and filter insert in place, (2) a cotton bandana folded diagonally once (ie, "bandit" style) or in a (3) multilayer rectangle according to the instructions presented by the US Surgeon General, (4) a single-layer polyester/nylon mask with ties, (5) a polypropylene mask with fixed ear loops, (6) a single-layer polyester gaiter/neck cover balaclava bandana, and (7) a 3-layer cotton mask with ear loops. Medical procedure mask modifications included (1) tying the mask's ear loops and tucking in the side pleats, (2) fastening ear loops behind the head with 3-dimensional-printed ear guards, (3) fastening ear loops behind the head with a claw-type hair clip, (4) enhancing the mask/face seal with rubber bands over the mask, and (5) enhancing the mask/face seal with a band of nylon hosiery over the fitted mask. Main Outcomes and Measures: The primary study outcome was the measured FFE of common consumer-grade and improvised face masks, as well as several popular modifications of medical procedure masks. Results: The mean (SD) FFE of consumer grade masks tested on 1 adult male with no beard ranged from 79.0% (4.3%) to 26.5% (10.5%), with the 2-layer nylon mask having the highest FFE. Unmodified medical procedure masks with ear loops had a mean (SD) FFE of 38.5% (11.2%). All modifications evaluated in this study increased procedure mask FFE (range [SD], 60.3% [11.1%] to 80.2% [3.1%]), with a nylon hosiery sleeve placed over the procedure mask producing the greatest improvement. Conclusions and Relevance: While modifications to improve medical procedure mask fit can enhance the filtering capability and reduce inhalation of airborne particles, this study demonstrates that the FFEs of consumer-grade masks available to the public are, in many cases, nearly equivalent to or better than their non-N95 respirator medical mask counterparts.


Assuntos
COVID-19/prevenção & controle , COVID-19/transmissão , Máscaras , Adulto , Fibra de Algodão , Desenho de Equipamento , Filtração/instrumentação , Humanos , Masculino , Nylons , Poliésteres , Polipropilenos , Roupa de Proteção
17.
J Cyst Fibros ; 19(6): 942-948, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32669217

RESUMO

BACKGROUND: Hypertonic saline (HS) is commonly prescribed for children with cystic fibrosis (CF) despite the absence of strong data indicating clinical efficacy in a population with mild lung disease. We hypothesized that HS treatment would result in a sustained improvement in mucociliary clearance (MCC) in children with CF who had minimal lung disease, thus providing evidence for a biologically relevant effect that also may be associated with clinical improvements. METHODS: We performed a randomized, placebo controlled, double blind study of 6% versus 0.12% sodium chloride, delivered three-times daily with an eFlow nebulizer for 4 weeks. MCC was measured using gamma scintigraphy at baseline, 2-hours after the first study treatment, and ~12-hours after the final dose (at day 28). Spirometry, respiratory symptoms (CFQ-R), and safety were also assessed. RESULTS: Study treatments were generally well tolerated and safe. HS (6% sodium chloride) resulted in a significant, sustained improvement from baseline in whole lung clearance after 4 weeks of therapy (p = 0.014), despite absence of a prolonged single-dose effect after the initial dose. This sustained change (12 hrs after prior dose) was significantly greater when compared to placebo (0.12% sodium chloride) treatment (p = 0.016). Improvements in spirometry with HS did not reach statistical significance but correlated with MCC changes. CONCLUSIONS: The observed sustained improvement in MCC with HS suggests that this treatment may yield health benefits, even in relatively mildly affected children with CF. Highlighting this physiologic finding is important due to the lack of meaningful, validated endpoints in this population.


Assuntos
Fibrose Cística/tratamento farmacológico , Depuração Mucociliar/efeitos dos fármacos , Solução Salina Hipertônica/administração & dosagem , Administração por Inalação , Criança , Método Duplo-Cego , Feminino , Humanos , Masculino , Nebulizadores e Vaporizadores
18.
JAMA Intern Med ; 180(12): 1607-1612, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32780113

RESUMO

Importance: Procuring respiratory protection for clinicians and other health care workers has become a major challenge of the coronavirus disease 2019 (COVID-19) pandemic and has resulted in nonstandard practices such as the use of expired respirators and various decontamination processes to prolong the useful life of respirators in health care settings. In addition, imported, non-National Institute for Occupational Safety and Health (NIOSH)-approved respirators have been donated or acquired by hospitals as a potential replacement for limited NIOSH-approved N95 respirators. Objective: To assess fitted filtration efficiencies (FFEs) for face mask alternatives used during the COVID-19 pandemic. Design, Setting, and Participants: For this quality-improvement study conducted between April and June 2020, we used the Occupational Safety and Health Administration's Quantitative Fit Testing Protocol for Filtering Facepiece Respirators in a laboratory atmosphere supplemented with sodium chloride particles to assess the FFEs of a variety of respirators worn by a male volunteer and female volunteer. Main Outcomes and Measures: The FFEs of respirators commonly worn by clinicians and other health care workers and available respirator alternatives during the COVID-19 pandemic. Results: Of the 29 different fitted face mask alternatives tested on 1 man and 1 woman, expired N95 respirators with intact elastic straps and respirators subjected to ethylene oxide and hydrogen peroxide sterilization had unchanged FFE (>95%). The performance of N95 respirators in the wrong size had slightly decreased performance (90%-95% FFE). All of the respirators not listed as approved in this evaluation (n = 6) failed to achieve 95% FFE. Neither of the 2 imported respirators authorized for use by the Centers for Disease Control and Prevention that were not NIOSH-approved tested in this study achieved 95% FFE, and the more effective of the 2 functioned at approximately 80% FFE. Surgical and procedural face masks had filtering performance that was lower relative to that of N95 respirators (98.5% overall FFE), with procedural face masks secured with elastic ear loops showing the lowest efficiency (38.1% overall FFE). Conclusions and Relevance: This quality-improvement study evaluating 29 face mask alternatives for use by clinicians interacting with patients during the COVID-19 pandemic found that expired N95 respirators and sterilized, used N95 respirators can be used when new N95 respirators are not available. Other alternatives may provide less effective filtration.


Assuntos
COVID-19 , Reutilização de Equipamento/normas , Filtração/normas , Controle de Infecções/instrumentação , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Máscaras , Respiradores N95 , Esterilização , COVID-19/epidemiologia , COVID-19/prevenção & controle , COVID-19/transmissão , Desinfetantes , Contaminação de Equipamentos/prevenção & controle , Análise de Falha de Equipamento/métodos , Óxido de Etileno/farmacologia , Pessoal de Saúde , Humanos , Peróxido de Hidrogênio/farmacologia , Máscaras/classificação , Máscaras/normas , Máscaras/provisão & distribuição , Teste de Materiais/métodos , Respiradores N95/normas , Respiradores N95/provisão & distribuição , Melhoria de Qualidade , SARS-CoV-2 , Esterilização/métodos , Esterilização/normas
19.
ERJ Open Res ; 6(3)2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32802823

RESUMO

BACKGROUND: Mucus dehydration and impaired mucus clearance are common features of cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD). In CF, inhaled hypertonic saline (HS) improves lung function and produces sustained increases in mucociliary clearance (MCC). We hypothesised that administration of HS (7% NaCl) twice daily for 2 weeks would improve clinical outcomes and produce sustained increases in MCC in COPD subjects with a chronic bronchitis (CB) phenotype. METHODS: Twenty-two CB subjects completed a double-blinded, crossover study comparing inhaled HS to a hypotonic control solution (0.12% saline) administered via nebuliser twice daily for 2 weeks. Treatment order was randomised. During each treatment period, symptoms and spirometry were measured. MCC was measured at baseline, shortly after initial study agent administration, and approximately 12 h after the final dose. RESULTS: HS was safe and well tolerated but overall produced no significant improvements in spirometry or patient-reported outcomes. CB subjects had slower baseline MCC than healthy subjects. The MCC rates over 60 min (Ave60Clr) in CB subjects following 2 weeks of HS were not different from 0.12% saline but were slower than baseline (Ave60Clr was 9.1±6.3% at baseline versus 5.3±6.9% after HS; p<0.05). Subgroup analyses determined that subjects with residual baseline central lung clearance (14 subjects) had improved spirometry and symptoms following treatment with HS, but not 0.12% saline, treatment. CONCLUSIONS: Inhaled HS appeared to be safe in a general CB population. A specific phenotypic subgroup may benefit from HS but requires additional study.

20.
Sci Rep ; 10(1): 10568, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32601278

RESUMO

Topical intra-nasal sprays are amongst the most commonly prescribed therapeutic options for sinonasal diseases in humans. However, inconsistency and ambiguity in instructions show a lack of definitive knowledge on best spray use techniques. In this study, we have identified a new usage strategy for nasal sprays available over-the-counter, that registers an average 8-fold improvement in topical delivery of drugs at diseased sites, when compared to prevalent spray techniques. The protocol involves re-orienting the spray axis to harness inertial motion of particulates and has been developed using computational fluid dynamics simulations of respiratory airflow and droplet transport in medical imaging-based digital models. Simulated dose in representative models is validated through in vitro spray measurements in 3D-printed anatomic replicas using the gamma scintigraphy technique. This work breaks new ground in proposing an alternative user-friendly strategy that can significantly enhance topical delivery inside human nose. While these findings can eventually translate into personalized spray usage instructions and hence merit a change in nasal standard-of-care, this study also demonstrates how relatively simple engineering analysis tools can revolutionize everyday healthcare. Finally, with respiratory mucosa as the initial coronavirus infection site, our findings are relevant to intra-nasal vaccines that are in-development, to mitigate the COVID-19 pandemic.


Assuntos
Administração por Inalação , Administração Intranasal/métodos , Betacoronavirus , Infecções por Coronavirus/prevenção & controle , Sistemas de Liberação de Medicamentos/métodos , Sprays Nasais , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , COVID-19 , Simulação por Computador , Infecções por Coronavirus/virologia , Humanos , Hidrodinâmica , Cavidade Nasal/anatomia & histologia , Mucosa Nasal/efeitos dos fármacos , Mucosa Nasal/virologia , Nebulizadores e Vaporizadores , Seios Paranasais/efeitos dos fármacos , Seios Paranasais/virologia , Pneumonia Viral/virologia , SARS-CoV-2 , Vacinas Virais/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA