1.
Eur Radiol ; 31(7): 5324-5334, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449188

RESUMO

OBJECTIVES: To compare the spectral performance of dual-energy CT (DECT) platforms using task-based image quality assessment based on phantom data. MATERIALS AND METHODS: Two CT phantoms were scanned on four DECT platforms: fast kV-switching CT (KVSCT), split filter CT (SFCT), dual-source CT (DSCT), and dual-layer CT (DLCT). Acquisitions on each phantom were performed using classical parameters of abdomen-pelvic examination and a CTDIvol at 10 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated from 40 to 140 keV of virtual monoenergetic images. A detectability index (d') was computed to model the detection task of two contrast-enhanced lesions as function of keV. RESULTS: The noise magnitude decreased from 40 to 70 keV for all DECT platforms, and the highest noise magnitude values were found for KVSCT and SFCT and the lowest for DSCT and DLCT. The average NPS spatial frequency shifted towards lower frequencies as the energy level increased for all DECT platforms, smoothing the image texture. TTF values decreased with the increase of keV deteriorating the spatial resolution. For both simulated lesions, higher detectability (d' value) was obtained at 40 keV for DLCT, DSCT, and SFCT but at 70 keV for KVSCT. The detectability of both simulated lesions was highest for DLCT and DSCT. CONCLUSION: Highest detectability was found for DLCT for the lowest energy levels. The task-based image quality assessment used for the first time for DECT acquisitions showed the benefit of using low keV for the detection of contrast-enhanced lesions. KEY POINTS: • Detectability of both simulated contrast-enhanced lesions was higher for dual-layer CT for the lowest energy levels. • The image noise increased and the image texture changed for the lowest energy levels. • The detectability of both simulated contrast-enhanced lesions was highest at 40 keV for all dual-energy CT platforms except for fast kV-switching platform.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Abdome/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Eur Radiol ; 30(1): 487-500, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31359122

RESUMO

PURPOSE: To assess the dose performance in terms of image quality of filtered back projection (FBP) and two generations of iterative reconstruction (IR) algorithms developed by the most common CT vendors. MATERIALS AND METHODS: We used four CT systems equipped with a hybrid/statistical IR (H/SIR) and a full/partial/advanced model-based IR (MBIR) algorithms. Acquisitions were performed on an ACR phantom at five dose levels. Raw data were reconstructed using a standard soft tissue kernel for FBP and one iterative level of the two IR algorithm generations. The noise power spectrum (NPS) and the task-based transfer function (TTF) were computed. A detectability index (d') was computed to model the detection task of a large mass in the liver (large feature; 120 HU and 25-mm diameter) and a small calcification (small feature; 500 HU and 1.5-mm diameter). RESULTS: With H/SIR, the highest values of d' for both features were found for Siemens, then for Canon and the lowest values for Philips and GE. For the large feature, potential dose reductions with MBIR compared with H/SIR were - 35% for GE, - 62% for Philips, and - 13% for Siemens; for the small feature, corresponding reductions were - 45%, - 78%, and - 14%, respectively. With the Canon system, a potential dose reduction of - 32% was observed only for the small feature with MBIR compared with the H/SIR algorithm. For the large feature, the dose increased by 100%. CONCLUSION: This multivendor comparison of several versions of IR algorithms allowed to compare the different evolution within each vendor. The use of d' is highly adapted and robust for an optimization process. KEY POINTS: • The performance of four CT systems was evaluated by using imQuest software to assess noise characteristic, spatial resolution, and lesion detection. • Two task functions were defined to model the detection task of a large mass in the liver and a small calcification. • The advantage of task-based image quality assessment for radiologists is that it does not include only complicated metrics, but also clinically meaningful image quality.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Calcinose/diagnóstico por imagem , Humanos , Hepatopatias/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Radiometria/métodos , Cintilografia , Software , Tomografia Computadorizada por Raios X/normas
3.
Eur Radiol ; 30(2): 1075-1078, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31506818

RESUMO

OBJECTIVES: To determine the best compromise between low radiation dose and suitable image quality for the detection of lytic and sclerotic bone lesions of the lumbar spine and pelvis. METHODS: A phantom was scanned using the routine protocol (STD, 13 mGy) and six decreasing dose levels. Raw data were reconstructed using level 3 of iterative reconstruction (IR3) with 1-mm slice thickness for the STD protocol and highest IR levels with 3-mm slice thickness for the others. CTDIvol was used for radiation dose assessment. Quantitative criteria (noise power spectrum [NPS], task-based transfer function [TTF], and the detectability index [d']), as well as qualitative analysis, were used to compare protocols. NPS and TTF were computed using specific software (imQuest). d' was computed for two imaging tasks: lytic and sclerotic bone lesions. A subjective analysis was performed to validate the image quality obtained on the anthropomorphic phantom with the different dose values. RESULTS: Similar d' values were found for CTDIvol from 3 to 4 mGy with IR4 and from 1 to 2 mGy for IR5 compared with d' values using the STD protocol. Image quality was validated subjectively for IR4 but rejected for IR5 (image smoothing). Finally, for the same d', the dose was reduced by 74% compared with the STD protocol, with the CTDIvol being 3.4 mGy for the lumbar spine and for the pelvis. CONCLUSION: A dose level as low as 3.4 mGy, in association with high levels of IR, provides suitable image quality for the detection of lytic and sclerotic bone lesions of the lumbar spine and pelvis. KEY POINTS: • A CTDI volof 3.4 mGy, in association with high iterative reconstruction level, provides suitable image quality for the detection of lytic and sclerotic bone lesions, both at objective and subjective analysis. • Compared with the standard protocol, radiation dose can be reduced up to 74% for the lumbar spine and pelvis. • A task-based image quality assessment using  the detectability index represents an objective method for the assessment of image quality and bridges the gap between complex physical metrics and subjective image analysis.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Vértebras Lombares/diagnóstico por imagem , Pelve/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
4.
Eur Radiol ; 29(3): 1635-1636, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30167810

RESUMO

The original version of this article, published on 01 August 2018, unfortunately contained two mistakes.

5.
Eur Radiol ; 29(2): 674-681, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30069810

RESUMO

OBJECTIVE: To assess diagnostic reference levels (DRLs) in surgery for the most frequent procedures as required by the European Directive 2013/59/Euratom. METHODS: A survey was conducted in six centers. Eight orthopedic, urology and gastrointestinal surgical procedures were analyzed. Kerma area product (KAP) and fluoroscopy time (FT) were recorded for 50 patients (except for elbow: 30 patients) per procedure and per center from September 2016 to September 2017. DRLs were calculated as the 3rd quartiles of the distributions. For shoulder surgery, DRLs were defined according to the complexity of the procedure. For hand/wrist and foot/ankle surgery, DRLs were defined according to the technology (conventional C-arm vs. mini-C-arm). RESULTS: Results of 1870 procedures were retrieved. DRLs were calculated for the two dosimetric indicators and the eight procedures. DRLs were 2130 mGy.cm2 and 1.4 min for proximal femoral intramedullary nail, 1185 mGy.cm2 and 0.9 min for laparoscopic cholecystectomy and 2195 mGy.cm2 and 1.0 min for double-J (pigtail) ureteral catheter insertion. For shoulder surgery, KAP and FT were significantly higher (p < 0.05) for intramedullary procedures compared to extramedullary procedures. For hand/wrist and foot/ankle surgery, the KAPs were significantly higher (p < 0.05) with conventional C-arm compared to mini-C-arm, but FTs were not significantly different (p: not significant). CONCLUSION: This study reports DRLs in surgery based on a multicentric survey. KEY POINTS: • Delivered dose in surgery depends on procedure, practice and patient. • Diagnostic reference levels (DRLs) are proposed for eight surgical procedures. • DRLs are useful to benchmark practices and optimize protocols.


Assuntos
Fluoroscopia/normas , Doses de Radiação , Radiografia Intervencionista/normas , Procedimentos Cirúrgicos Operatórios/normas , Adolescente , Adulto , Idoso , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Proteção Radiológica/normas , Radiografia Intervencionista/métodos , Radiometria , Valores de Referência , Estudos Retrospectivos , Adulto Jovem
6.
Eur Radiol ; 24(8): 1989-97, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24838739

RESUMO

OBJECTIVE: To analyse pelvic autonomous innervation with magnetic resonance imaging (MRI) in comparison with anatomical macroscopic dissection on cadavers. MATERIAL AND METHODS: Pelvic MRI was performed in eight adult human cadavers (five men and three women) using a total of four sequences each: T1, T1 fat saturation, T2, diffusion weighed. Images were analysed with segmentation software in order to extract nervous tissue. Key height points of the pelvis autonomous innervation were located in every specimen. Standardised pelvis dissections were then performed. Distances between the same key points and the three anatomical references forming a coordinate system were measured on MRIs and dissections. Concordance (Lin's concordance correlation coefficient) between MRI and dissection was calculated. RESULTS: MRI acquisition allowed an adequate visualization of the autonomous innervation. Comparison between 3D MRI images and dissection showed concordant pictures. The statistical analysis showed a mean difference of less than 1 cm between MRI and dissection measures and a correct concordance correlation coefficient on at least two coordinates for each point. CONCLUSION: Our acquisition and post-processing method demonstrated that MRI is suitable for detection of autonomous pelvic innervations and can offer a preoperative nerve cartography. KEY POINTS: • Nerve preservation is a hot topic in pelvic surgery • High resolution MRI can show distal peripheral nerves • Anatomo-radiological comparison shows good correlation between MRI and dissection • 3D reconstructions of pelvic innervation were obtained with an original method • This is a first step towards image-guided pelvic surgery.


Assuntos
Sistema Nervoso Autônomo/anatomia & histologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Pelve/inervação , Cirurgia Assistida por Computador/métodos , Adulto , Cadáver , Método Duplo-Cego , Feminino , Humanos , Masculino , Pelve/cirurgia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
7.
Radiol Med ; 118(1): 74-88, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22466875

RESUMO

Malperfusion syndrome is a complication of aortic dissection caused by branch-vessel involvement and resulting in end-organ ischaemic dysfunction. Clinical diagnosis is mandatory, and imaging plays a critical role in confirmation and treatment planning. Radiologists must focus on detecting complications (findings of aortic dilation, rupture, organ ischaemia, etc.) and defining vascular compromise and associated malperfusion mechanisms. All these factors guide the multidisciplinary discussion concerning patient management and the suitability of endovascular treatment. Application of dedicated imaging protocols is mandatory in order to answer clinical and anatomical questions. Endovascular therapy has taken a predominant role in the therapeutic management of malperfusion syndrome with aortic fenestration, peripheral stenting and stent-grafting, all of which are procedures within the domain of expertise of current interventional radiologists. The purpose of this editorial is to present a when, what and how-to guide for all radiologists who encounter complicated aortic dissection.


Assuntos
Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Angiografia , Implante de Prótese Vascular , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Humanos , Síndrome , Tomografia Computadorizada por Raios X
8.
Phys Med ; 109: 102574, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37004360

RESUMO

PURPOSE: To assess the impact of the automatic tube current modulation (ATCM) on virtual monoenergetic images (VMIs) quality in dual-source CT(DSCT). MATERIALS AND METHODS: Acquisitions were performed on DSCT using the Mercury phantom. The acquisition parameters for an abdomen-pelvic examination with single-energy CT(SECT) and dual-energy CT(DECT) imaging were used. Acquisitions were performed for each imaging mode using fixed mAs and ATCM. The mAs value was set to obtain a volume CT dose index of 11 mGy in fixed mAs acquisitions. This value was used as the reference mAs in ATCM acquisitions. The noise power spectrum and task-based transfer function at 40,50,60 and 70 keV levels were computed on VMIs and SECT images. The detectability index (d') was calculated for a lesion with an iodine concentration of 10 mg/mL. RESULTS: The noise magnitude on VMIs was higher with the ATCM system than with fixed mAs for all energy levels and section diameters of 21,26 and 31 cm. The noise texture and spatial resolution were similar between the fixed mAs and ATCM acquisitions for both imaging modes. The d' values were lower for all energy levels with ATCM than with fixed mAs acquisitions for 21 and 26 cm diameters by -39.82 ± 9.32%, similar at 31 cm diameter -4.13 ± 0.24% and higher at 36 cm diameter 10.40 ± 6.69%. It was higher on VMIs at all energy levels compared to SECT images. CONCLUSIONS: The ATCM system could be used with DECT imaging to optimize patient exposure without changing the noise texture and spatial resolution of VMIs compared to fixed mAs and SECT.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação
9.
Skeletal Radiol ; 41(1): 33-40, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21308468

RESUMO

OBJECTIVE: The purpose of this study was to assess denervated muscle perfusion using dynamic susceptibility contrast MRI (DSCMRI) and contrast-enhanced ultrasound (CEUS), and to measure denervated muscle apparent diffusion coefficient (ADC) on b1000 diffusion-weighted MRI (DWMRI) at 3 T in order to clarify whether muscle denervation leads to an increase in the extracellular extravascular space, or an increase in blood flow-or both. MATERIALS AND METHODS: Axotomy of the right sciatic nerve of six white rabbits was performed at day 0. At day 9, hind limb muscles MRI and CEUS were performed to assess the consequences of denervation and both semimembranosus muscles of each rabbit were explanted for histological studies. Signal intensity on T2- and T1-weighted MRI, ADC on DWMRI, maximum signal drop (MSD) on DSCMRI and the area under the curve (AUC) on CEUS were measured over circular regions of interest (ROI), in both semimembranosus muscles. Non-parametric Wilcoxon matched-pairs tests were used to assess the mean differences between denervated and normal muscles. RESULTS: T2 fat-saturated (FS) MRI studies showed a strong signal in the right semimembranosus muscles compared with the left side, and gadolinium enhancement was observed on T1 FS MRI. Denervated muscles show a significant increase in ADC on DWMRI (p < 0.01) and a significant signal enhancement on DSCMR imaging (p < 0.05) and on first-pass CEUS (p < 0.05). CONCLUSION: The results of this study--based on perfusion- and diffusion-weighted images--suggest that, after denervation, both increased blood flow through muscle tissue and expansion of the extracellular water volume are present.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia , Imagem de Perfusão/métodos , Nervo Isquiático/fisiologia , Nervo Isquiático/cirurgia , Ultrassonografia/métodos , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Músculo Esquelético/patologia , Coelhos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Diagn Interv Imaging ; 101(6): 373-381, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32008994

RESUMO

PURPOSE: The purpose of this study was to assess the impact of tin filter (TF) on X-ray beam quality, image quality and radiation dose and its suitability for routine use for chest and lumbar-spine/pelvis-hip ultralow-dose (ULD) CT examination protocols. MATERIALS AND METHODS: The X-ray beam quality was determined by measuring the half-value layer (HVL) and calculating the mean weighted energy for 100, 120, 150kVp (using standard filtration) and for 100 and 150kVp using TF (Sn100kVp and Sn150kVp, respectively). Acquisitions were performed on a phantom at four dose levels for each previously definedkVp. The mean attenuation (NCT), noise-power-spectrum (NPS) and task-based transfer function (TTF) were computed. The detectability index (d') was computed to model the detection of two lesions in spine and pelvic/hip examination and two for chest exploration. Image quality and detectability using a TF were assessed for two routinely used ULD protocols. RESULTS: The HVL and mean weighted energy increased using a TF for the same tube voltage. Using a TF for the same tube voltage changed NCT for bone and acrylic inserts, decreased the NPS peak without changing the NPS spatial frequency and increased the TTF values. The d' values were improved using a TF and with the dose increase. d' values of all modeled lesions were improved using Sn100kVp and Sn150kVp for the lumbar-spine/pelvis-hip and chest ULD protocols except for sclerotic bone lesion using Sn150kVp. CONCLUSION: The use of TF increases the X-ray beam quality and improves the image quality characteristics in phantom images, thus appearing as a promising tool for reducing dose and/or improving the image quality of ULD protocols.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Estanho , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
11.
Phys Med ; 77: 36-42, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32771702

RESUMO

PURPOSE: To assess the impact of iterative reconstructions on image quality and detectability of focal liver lesions in low-energy monochromatic images from a Fast kV-Switching Dual Energy CT (KVSCT) platform. METHODS: Acquisitions on an image-quality phantom were performed using a KVSCT for three dose levels (CTDIvol:12.72/10.76/8.79 mGy). Raw data were reconstructed for five energy levels (40/50/60/70/80 keV) using Filtered Back Projection (FBP) and four levels of ASIR (ASIR30/ASIR50/ASIR70/ASIR100). Noise power spectrum (NPS) and task-based transfer function (TTF) were measured before computing a Detectability index (d') to model the detection task of liver metastasis (LM) and hepatocellular carcinoma (HCC) as function of keV. RESULTS: From 40 to 70 keV, noise-magnitude was reduced on average by -68% ± 1% with FBP; -61% ± 3% with ASIR50 and -52% ± 6% with ASIR100. The mean spatial frequency of the NPS decreased when the energy level decreased and the iterative level increased. TTF values at 50% decreased as the energy level increased and as the percentage of ASIR increased. The detectability of both lesions increased with increasing dose level and percentage of ASIR. For the LM, d' peaked at 70 keV for all reconstruction types, except for ASIR70 at 12.72 mGy and ASIR100, where d' peaked at 50 keV. For HCC, d' peaked at 60 keV for FBP and ASIR30 but peaked at 50 keV for ASIR50, ASIR70 and ASIR100. CONCLUSIONS: Using percentage of ASIR above 50% at low-energy monochromatic images could limit the increase of noise-magnitude, benefit from spatial resolution improvement and hence enhance detectability of subtle low contrast focal liver lesions such as HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação
12.
Diagn Interv Imaging ; 101(7-8): 473-479, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32499192

RESUMO

PURPOSE: To compare the evaluation of malignant focal liver lesions (FLLs) using a semi-automated RECIST tool with a standard and an ultra-low dose (ULD) computed tomography (CT) protocol. MATERIALS AND METHODS: Thirty-four patients with malignant FLLs underwent two abdominal-pelvic CT examinations one using a standard protocol and one using an ULD protocol. There were 23 men and 11 women with a mean age 64.3±14.4 (SD) years (range: 22-91 years). Dosimetric indicators were recorded, and effective dose was calculated for both examinations. Mean malignant FLL attenuation, image noise and contrast-to-noise-ratio (CNR) were compared. The largest malignant FLL per patient was evaluated using the semi-automated RECIST tool to determine longest axis length, longest orthogonal axis length, volume and World Health Organisation area. RESULTS: Dosimetric values were significantly reduced by -56% with ULD compared to standard protocol. No differences in mean malignant FLL attenuation values were found between the two protocols. Image noise was significantly increased for all locations (P<0.05) with ULD compared to standard protocol, and CNR was significantly reduced (P<0.05). On the 34 malignant FLLs analyzed, six semi-automated shapes non-concordant with radiologist's visual impression were highlighted with the software, including one FLL (1/34; 3%) with standard CT acquisition only, three FLLs (3/34; 9%) with ULD CT acquisition only and two FLLs (2/34; 6%) with both CT acquisitions. After manual editing, the concordance of the values of the studied criteria between both acquisitions was good and no significant difference was reported. CONCLUSION: Semi-automated RECIST tool demonstrates good performances using ULD CT protocol. It could be used in routine clinical practice with a ULD protocol for follow-up studies in patients with known malignant FLL.


Assuntos
Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Critérios de Avaliação de Resposta em Tumores Sólidos , Software
13.
Diagn Interv Imaging ; 101(5): 289-297, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31932228

RESUMO

PURPOSE: To determine the lowest suitable dose level for the detection of pulmonary arteriovenous malformation (PAVM) using a task-based image quality assessment. MATERIAL AND METHODS: A phantom was scanned using the standard chest protocol (STD) and 4 other ultra-low dose protocols (ULD) using various kVp. Raw data were reconstructed using level 5 of the hybrid iterative reconstruction algorithm (iDose4) for the STD protocol, and level 6 of iDose4 and levels 1 to 3 of model-based iterative reconstruction (IMR) for the ULD protocols. Both quantitative criteria and qualitative analysis were used to compare protocols. Noise-power-spectrum and Task-based transfer function were computed using imQuest software. The detectability-index (d') was computed for the detection of PAVM. A subjective analysis was performed by 2 chest radiologists to validate the image-quality obtained on the anthropomorphic phantom for all protocols. RESULTS: Similar d' values were found for ULD-140 using iDose4 6 compared to STD protocol. Greater d' values were found for all ULD protocols using IMR compared to STD. Subjective image quality was rated as acceptable to excellent for ULD-140 and ULD-120 for all reconstruction types, for ULD-100 and ULD-80 using IMR2, and for ULD-100 using IMR1. Image smoothing was poor for IMR3 for ULD-100 and ULD-80. Finally, the ULD-80 protocol reconstructed with IMR2 was chosen for the detection of PAVM. With this protocol, the dose (CTDIvol of 0.3mGy) was reduced by 91% compared with the STD protocol. CONCLUSION: A dose level as low as 0.3mGy reconstructed with IMR2 provides an image quality suitable for the detection of PAVM.


Assuntos
Malformações Arteriovenosas , Interpretação de Imagem Radiográfica Assistida por Computador , Algoritmos , Malformações Arteriovenosas/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X
14.
Diagn Interv Imaging ; 101(1): 7-14, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31324590

RESUMO

PURPOSE: The purpose of this study was to evaluate a cooperation program in order to compare incidence of complications after peripherally inserted central catheter (PICC) placement between radiologists and technicians. MATERIALS AND METHODS: PICC placement technique was standardized with ultrasound-guided puncture and fluoroscopic guidance. Numbers of PICC delegated to technicians, and PICC placement difficulties, were prospectively recorded for the whole study population whereas complications such as PICC infection, deep venous thrombosis and catheter occlusion were prospectively recorded until PICC removal for a subgroup of patients included during one month. RESULTS: A total of 722 patients had PICC placement. There were 382 men and 340 women with a mean age of 66.8±15.8 (SD) years (range: 18-94years); of these, 442/722 patients (61.22%) were included in the cooperation program with 433/722 patients (59.97%) who effectively had PICC placement by technicians and 289/722 (40.03%) by radiologists. Technicians needed radiologists' help for 23/442 patients (5.20%) including 6 failed PICC placement subsequently performed by radiologists. Twenty complications (20/77; 26%) were recorded in the subgroup of 77 patients studied for complications. No differences in complications rate were found between the 33 patients who underwent PICC placement by radiologists (6/33; 18%) and the 44 patients who underwent PICC placement by technicians (14/44; 32%) (P=0.296). Complications included 8 PICC-related infections (8/77; 10.4%), 3 deep venous thromboses (3/77; 3.9%) and 9 catheter occlusions (9/77; 11.7%). CONCLUSION: PICC placement led by technicians is feasible and safe without statistical difference in terms of complications compared to PICC placement made by radiologists.


Assuntos
Cateterismo Periférico/normas , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Pessoal Técnico de Saúde , Cateterismo Periférico/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Equipe de Assistência ao Paciente , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Radiologia , Adulto Jovem
15.
Diagn Interv Imaging ; 101(12): 783-788, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32245723

RESUMO

PURPOSE: The second edition of the artificial intelligence (AI) data challenge was organized by the French Society of Radiology with the aim to: (i), work on relevant public health issues; (ii), build large, multicentre, high quality databases; and (iii), include three-dimensional (3D) information and prognostic questions. MATERIALS AND METHODS: Relevant clinical questions were proposed by French subspecialty colleges of radiology. Their feasibility was assessed by experts in the field of AI. A dedicated platform was set up for inclusion centers to safely upload their anonymized examinations in compliance with general data protection regulation. The quality of the database was checked by experts weekly with annotations performed by radiologists. Multidisciplinary teams competed between September 11th and October 13th 2019. RESULTS: Three questions were selected using different imaging and evaluation modalities, including: pulmonary nodule detection and classification from 3D computed tomography (CT), prediction of expanded disability status scale in multiple sclerosis using 3D magnetic resonance imaging (MRI) and segmentation of muscular surface for sarcopenia estimation from two-dimensional CT. A total of 4347 examinations were gathered of which only 6% were excluded. Three independent databases from 24 individual centers were created. A total of 143 participants were split into 20 multidisciplinary teams. CONCLUSION: Three data challenges with over 1200 general data protection regulation compliant CT or MRI examinations each were organized. Future challenges should be made with more complex situations combining histopathological or genetic information to resemble real life situations faced by radiologists in routine practice.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Radiologistas
16.
Ann Rheum Dis ; 68(12): 1878-84, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19054830

RESUMO

OBJECTIVES: To assess the prevalence and patterns of cardiac abnormalities as detected by cardiac magnetic resonance imaging (MRI) in systemic sclerosis (SSc). METHODS: Fifty-two consecutive patients with SSc underwent cardiac MRI to determine morphological, functional, perfusion at rest and delayed enhancement abnormalities. RESULTS: At least one abnormality on cardiac MRI was observed in 39/52 patients (75%). Increased myocardial signal intensity in T2 was observed in 6 patients (12%), thinning of left ventricle (LV) myocardium in 15 patients (29%) and pericardial effusion in 10 patients (19%). LV and right ventricle (RV) ejection fractions were altered in 12 patients (23%) and 11 patients (21%), respectively. LV diastolic dysfunction was found in 15/43 patients (35%). LV kinetic abnormalities were found in 16/52 patients (31%) and myocardial delayed contrast enhancement was detected in 11/52 patients (21%). No perfusion defects at rest were found. Patients with limited SSc had similar MRI abnormalities to patients with diffuse SSc. Seven of 40 patients (17%) without pulmonary arterial hypertension had RV dilatation. CONCLUSIONS: This study shows that MRI is a reliable and sensitive technique for diagnosing heart involvement in SSc and for analysing its mechanisms, including its inflammatory, microvascular and fibrotic components. Compared with echocardiography, MRI appears to provide additional information by visualising myocardial fibrosis and inflammation. RV dilatation appeared to be non-specific for pulmonary arterial hypertension but could also reflect myocardial involvement related to SSc. Further studies are needed to determine whether cardiac MRI abnormalities have an impact on the prognosis and treatment strategy.


Assuntos
Cardiopatias/diagnóstico , Escleroderma Sistêmico/diagnóstico , Adulto , Idoso , Meios de Contraste , Estudos Transversais , Feminino , Cardiopatias/patologia , Ventrículos do Coração/patologia , Humanos , Hipertensão Pulmonar/etiologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Esclerodermia Difusa/diagnóstico , Esclerodermia Difusa/patologia , Esclerodermia Limitada/diagnóstico , Esclerodermia Limitada/patologia , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/patologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Direita/diagnóstico
17.
Int J Clin Pract ; 63(1): 63-70, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19125994

RESUMO

AIMS: The deleterious nature of peripheral arterial disease (PAD) is compounded by a status of underdiagnosed and undertreated disease. We evaluated the prevalence and predictive factors of PAD in high-risk patients using the ankle-brachial index (ABI). METHODS: The ABI was measured by general practitioners in France (May 2005-February 2006) in 5679 adults aged 55 years or older and considered at high risk. The primary outcome was prevalence of PAD (ABI strictly below 0.90). RESULTS: In all, 21.3% patients had signs or symptoms suggestive of PAD, 42.1% had previous history of atherothrombotic disease and 36.6% had two or more cardiovascular risk factors. Prevalence of PAD was 27.8% overall, ranging from 10.4% in patients with cardiovascular risk factors only to approximately 38% in each other subgroup. Prevalence differed depending on the localization of atherothrombotic events: it was 57.1-75.0% in patients with past history of symptomatic PAD; 24.6-31.1% in those who had experienced cerebrovascular and/or coronary events. Regarding the classical cardiovascular risk factors, PAD was more frequent when smoking and hypercholesterolemia history were reported. PAD prevalence was also higher in patients with history of abdominal aortic aneurysm, renal hypertension or atherothrombotic event. Intermittent claudication, lack of one pulse in the lower limbs, smoking, diabetes and renovascular hypertension were the main factors predictive of low ABI. CONCLUSIONS: Given the elevated prevalence of PAD in high-risk patients and easiness of diagnosis using ABI in primary care, undoubtedly better awareness would help preserve individual cardiovascular health and achieve public health goals.


Assuntos
Índice Tornozelo-Braço , Doenças Cardiovasculares/prevenção & controle , Doenças Vasculares Periféricas/diagnóstico , Idoso , Doenças Cardiovasculares/epidemiologia , Métodos Epidemiológicos , Medicina de Família e Comunidade , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/epidemiologia , Prevalência , Fatores de Risco
18.
J Radiol ; 90(1 Pt 1): 37-41, 2009 Jan.
Artigo em Francês | MEDLINE | ID: mdl-19182712

RESUMO

PURPOSE: To determine the value of an angioplasty simulation to differentiate the users based on their level of experience. To determine the perceived usefulness of an angioplasty simulation program. MATERIALS AND METHODS: Forty-six radiologists performed a renal angioplasty on a VIST simulator (Mentice Corporation, Gothenburg, Sweden); the procedure was completed by 41 radiologists. The radiologists were divided into two groups based on the level of experience. Quantitative variables analyzed included procedure duration time and fluoroscopy time. The radiologists then completed a questionnaire evaluating the simulation program. RESULTS: Radiologists with more than 2 years of clinical experience (n=14) performed the procedures faster (20.4 min vs 27.4 min, p<0.01) using less fluoroscopy time (7.8 min vs 11.2 min, p<0.05) than others. Radiologists performing more than 2 procedures per month (n=14) performed the procedures faster (19.4 min vs 27.9 min, p<0.01) using less fluoroscopy time (7.4 min vs 11.3 min, p<0.05) than other (n=27). The participating radiologists indicated that the simulation was realistic. CONCLUSION: Procedure duration time and duration of fluoroscopy were criteria able to differentiate the users based on their level of experience. The educational value of the simulation program was perceived as helpful by the users.


Assuntos
Angiografia , Angioplastia , Simulação por Computador , Radiologia Intervencionista , Interface Usuário-Computador , Distribuição de Qui-Quadrado , Interpretação Estatística de Dados , Humanos , Aprendizagem , Radiologia Intervencionista/educação , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/terapia , Inquéritos e Questionários
19.
J Radiol ; 90(2): 179-89, 2009 Feb.
Artigo em Francês | MEDLINE | ID: mdl-19308002

RESUMO

MRA includes all techniques used to depict vessels with MR. Gadolinium contrast injection combined with gradient echo sequences is the technique of choice for vascular imaging. Technical advances now allow faster acquisitions. The purpose of this article is to present two main advances with MRA: whole-body MRA and dynamic 3D MRA. Technical considerations, acquisition techniques, advantages and pitfalls based on our experience with a 1.5T MR unit will be discussed in order to promote their use in routine clinical practice.


Assuntos
Gadolínio , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/tendências , Idoso , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade
20.
Diagn Interv Imaging ; 100(12): 763-770, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31473164

RESUMO

PURPOSE: To compare the noise-magnitude and noise-texture obtained using strong kernel across two generations of iterative reconstruction (IR) algorithms proposed by three manufacturers. MATERIALS AND METHODS: Five computed tomography (CT) systems equipped with two generations of IR algorithm (hybrid/statistical IR [H/SIR] or full/partial model-based IR [MBIR]) were compared. Acquisitions on Catphan 600 phantom were performed at 120kV and three dose levels (CTDIvol: 3, 7 and 12mGy). Raw data were reconstructed using standard "bone" kernel for filtered back projection and one iterative level of two generations of IR algorithms. Contrast-to-noise ratio (CNR) was computed using three regions of interest placed semi-automatically: two placed in the low-density polyethylene and Teflon inserts and another placed on the solid water. Noise power spectrum (NPS) was computed to assess the NPS-peak and noise-texture. RESULTS: CNR was significantly greater in MBIR compared to H/SIR algorithms for all CT systems (P<0.01). CNR were improved on average from H/SIR to MBIR of 36±14% [SD] (range: 24-57%) for GE-Healthcare, 109±19 [SD] % (range: 89-139%) for Philips Healthcare and 42±5 [SD] % (range: 36-47%) for Siemens Healthineers. The mean NPS peak decreased from H/SIR to MBIR by -41±6 [SD] % (range: -47--35%) for GE Healthcare, -79±3 [SD] % (range: -82--76%) for Philips Healthcare and -52±2 [SD] % (range: -54--51%) for Siemens Healthineers systems. NPS spatial frequencies were greater with MBIR than with H/SIR for Philips Healthcare (20 ± 2 [SD] %; range: 19-22%) and for Siemens Healthineers (9±5 [SD] %; range: 4-14%) but lower for GE Healthcare (-17±3 [SD] %; range: -14--20%). CONCLUSION: Using bone kernel with recent MBIR algorithms reduces the noise-magnitude for all CT systems assessed. Noise texture shifted towards high frequency for Siemens Healthineers and Philips Healthcare but the opposite for GE Healthcare.


Assuntos
Algoritmos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Humanos , Aumento da Imagem , Imagens de Fantasmas , Dosagem Radioterapêutica