1.
Eur Radiol ; 33(1): 699-710, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35864348

RESUMO

OBJECTIVES: To assess the impact of a new artificial intelligence deep-learning reconstruction (Precise Image; AI-DLR) algorithm on image quality against a hybrid iterative reconstruction (IR) algorithm in abdominal CT for different clinical indications. METHODS: Acquisitions on phantoms were performed at 5 dose levels (CTDIvol: 13/11/9/6/1.8 mGy). Raw data were reconstructed using level 4 of iDose4 (i4) and 3 levels of AI-DLR (Smoother/Smooth/Standard). Noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d') were computed: d' modelled detection of a liver metastasis (LM) and hepatocellular carcinoma at portal (HCCp) and arterial (HCCa) phases. Image quality was subjectively assessed on an anthropomorphic phantom by 2 radiologists. RESULTS: From Standard to Smoother levels, noise magnitude and average NPS spatial frequency decreased and the detectability (d') of all simulated lesions increased. For both inserts, TTF values were similar for all three AI-DLR levels from 13 to 6 mGy but decreased from Standard to Smoother levels at 1.8 mGy. Compared to the i4 used in clinical practice, d' values were higher using the Smoother and Smooth levels and close for the Standard level. For all dose levels, except at 1.8 mGy, radiologists considered images satisfactory for clinical use for the 3 levels of AI-DLR, but rated images too smooth using the Smoother level. CONCLUSION: Use of the Smooth and Smoother levels of AI-DLR reduces the image noise and improves the detectability of lesions and spatial resolution for standard and low-dose levels. Using the Smooth level is apparently the best compromise between the lowest dose level and adequate image quality. KEY POINTS: • Evaluation of the impact of a new artificial intelligence deep-learning reconstruction (AI-DLR) on image quality and dose compared to a hybrid iterative reconstruction (IR) algorithm. • The Smooth and Smoother levels of AI-DLR reduced the image noise and improved the detectability of lesions and spatial resolution for standard and low-dose levels. • The Smooth level seems the best compromise between the lowest dose level and adequate image quality.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Radiográfica Assistida por Computador , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Redução da Medicação , Inteligência Artificial , Imagens de Fantasmas , Algoritmos , Tomografia Computadorizada por Raios X/métodos
2.
Eur Radiol ; 33(8): 5476-5488, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36920517

RESUMO

OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Coração , Fótons
3.
Radiology ; 304(1): 123-125, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35258372

RESUMO

Online supplemental material is available for this article. See also the editorial by Tuite in this issue.


Assuntos
COVID-19 , Serviço Hospitalar de Radiologia , Radiologia , Humanos , Inquéritos e Questionários
4.
Eur Radiol ; 32(1): 524-532, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34185147

RESUMO

OBJECTIVES: To evaluate the image quality (IQ) of a spectral photon-counting CT (SPCCT) using filtered back projection (FBP) and hybrid iterative reconstruction (IR) algorithms (iDose4), in comparison with a dual-layer CT (DLCT) system, and to choose the best image quality according to the IR level for SPCCT. METHODS: Two phantoms were scanned using a standard lung protocol (120 kVp, 40 mAs) with SPCCT and DLCT systems. Raw data were reconstructed using FBP and 9 iDose4 levels (i1/i2/i3/i4/i5/i6/i7/i9/i11) for SPCCT and 7 for DLCT (i1/i2/i3/i4/i5/i6/i7). Noise power spectrum and task-based transfer function (TTF) were computed. Detectability index (d') was computed for detection of 4 mm ground-glass nodule (GGN) and solid nodule. Two chest radiologists performed an IQ evaluation (noise/nodule sharpness/nodule conspicuity/overall IQ) in consensus, and chose the best image for SPCCT. RESULTS: Noise magnitude was -47% ± 2% lower on average with SPCCT than with DLCT for iDose4 range from i1 to i6. Average NPS spatial frequencies increased for SPCCT in comparison with DLCT. TTF also increased, except for the air insert with FBP, and i1/i2/i3. Higher detectability was found for SPCCT for both GGN and solid nodules. IQ for both types of nodule was rated consistently higher with SPCCT than with DLCT for the same iDose4 level. For SPCCT and both nodules, the scores for noise and conspicuity improved with increasing iDose4 level. iDose4 level 6 provided the best subjective IQ for both types of nodule. CONCLUSIONS: Higher IQ for GGN and solid nodules was demonstrated with SPCCT compared with DLCT with better detectability using iDose4. KEY POINTS: Using spectral photon-counting CT compared with dual-layer CT, noise magnitude was reduced with improvements in spatial resolution and detectability of ground-glass nodules and solid lung nodules. As the iDose4 level increased, noise magnitude was reduced and detectability of ground-glass and solid lung nodules was better for both CT systems. For spectral photon-counting CT imaging, two chest radiologists determined iDose4 level 6 as the best image quality for detecting ground-glass nodules and solid lung nodules.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação
5.
Sensors (Basel) ; 22(11)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35684594

RESUMO

Microwave ablation systems allow for performing tumoral destruction in oncology. The objective of this study was to assess the early response and reliability of the microwave ablation zone size at one month for liver, kidney and lung lesions, as compared to the manufacturer's charts. Patients who underwent microwave ablation with the EmprintTM ablation system for liver, kidney and lung lesions between June 2016 and June 2018 were retrospectively reviewed. Local response and ablation zone size (major, L, and minor, l, axes) were evaluated on the one-month follow-up imaging. Results were compared to the manufacturers' charts using the Bland-Altman analysis. Fifty-five patients (mean age 68 ± 11 years; 95 lesions) were included. The one-month complete response was 94%. Liver ablations showed a good agreement with subtle, smaller ablation zones (L: -2 ± 5.7 mm; l: -5.2 ± 5.6 mm). Kidney ablations showed a moderate agreement with larger ablations for L (L: 8.69 ± 7.94 mm; l: 0.36 ± 4.77 mm). Lung ablations showed a moderate agreement, with smaller ablations for l (L: -5.45 ± 4.5 mm; l: -9.32 ± 4.72 mm). With 94% of early complete responses, the system showed reliable ablations for liver lesions, but larger ablations for kidney lesions, and smaller for lung lesions.


Assuntos
Fígado , Micro-Ondas , Idoso , Humanos , Rim/diagnóstico por imagem , Rim/cirurgia , Fígado/diagnóstico por imagem , Fígado/cirurgia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Radiology ; 298(2): E81-E87, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32870139

RESUMO

Background The role and performance of chest CT in the diagnosis of the coronavirus disease 2019 (COVID-19) pandemic remains under active investigation. Purpose To evaluate the French national experience using chest CT for COVID-19, results of chest CT and reverse transcription polymerase chain reaction (RT-PCR) assays were compared together and with the final discharge diagnosis used as the reference standard. Materials and Methods A structured CT scan survey (NCT04339686) was sent to 26 hospital radiology departments in France between March 2, 2020, and April 24, 2020. These dates correspond to the peak of the national COVID-19 epidemic. Radiology departments were selected to reflect the estimated geographic prevalence heterogeneities of the epidemic. All symptomatic patients suspected of having COVID-19 pneumonia who underwent both initial chest CT and at least one RT-PCR test within 48 hours were included. The final discharge diagnosis, based on multiparametric items, was recorded. Data for each center were prospectively collected and gathered each week. Test efficacy was determined by using the Mann-Whitney test, Student t test, χ2 test, and Pearson correlation coefficient. P < .05 indicated a significant difference. Results Twenty-six of 26 hospital radiology departments responded to the survey, with 7500 patients entered; 2652 did not have RT-PCR test results or had unknown or excess delay between the RT-PCR test and CT. After exclusions, 4824 patients (mean age, 64 years ± 19 [standard deviation], 2669 male) were included. With final diagnosis as the reference, 2564 of the 4824 patients had COVID-19 (53%). Sensitivity, specificity, negative predictive value, and positive predictive value of chest CT in the diagnosis of COVID-19 were 2319 of 2564 (90%; 95% CI: 89, 91), 2056 of 2260 (91%; 95% CI: 91, 92), 2056 of 2300 (89%; 95% CI: 87, 90), and 2319 of 2524 (92%; 95% CI: 91, 93), respectively. There was no significant difference for chest CT efficacy among the 26 geographically separate sites, each with varying amounts of disease prevalence. Conclusion Use of chest CT for the initial diagnosis and triage of patients suspected of having coronavirus disease 2019 was successful. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
COVID-19/diagnóstico por imagem , COVID-19/epidemiologia , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , SARS-CoV-2 , Sensibilidade e Especificidade , Adulto Jovem
7.
Eur Radiol ; 31(4): 2621-2633, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33034747

RESUMO

OBJECTIVES: To compare diagnosis performance and effective dose of ultra-low-dose CT (ULD CT) versus radiographs in suspected spinal or pelvic ring or hip fracture for minor trauma. METHODS: ULD CT, in addition to radiography, was prospectively performed in consecutive patients admitted to the emergency department for minor traumas, during working hours over 2 months. Presence of a recent fracture was assessed by two blind radiologists independently. Sensitivities and specificities were estimated using the best valuable comparator (BVC) as a reference and using a latent class model in Bayesian inference (BLCM). Dosimetric indicators were recorded and effective doses (E) were calculated using conversion coefficient. RESULTS: Eighty areas were analyzed in 69 patients, including 22 dorsal spine, 28 lumbar spine, and 30 pelvic ring/hip. Thirty-six fractures (45%) were observed. Applying the BVC method, depending on location, ULD CT sensitivity was 80 to 100% for reader 1 and 85 to 100% for reader 2, whereas radiographic sensitivity was 60 to 85% for reader 1 and 50 to 92% for reader 2. With BLCM approach for reader 2, ULD CT sensitivity for all locations/dorsal spine/lumbar spine and pelvic ring-hip was 87.1/75.9/84.2/76.9% respectively. Corresponding radiograph sensitivity was 73.8, 54.8, 80.4, and 68.7%. Effective doses of ULD CT were similar to radiographs for dorsal and hip locations whereas for lumbar spine, ULD CT effective dose was 1.83 ± 0.59 mSv compared with 0.96 ± 0.59 mSv (p < 0.001). CONCLUSION: Sensitivity for fracture detection was higher for ULD CT compared with radiographs with an effective dose comparable to radiographs. KEY POINTS: • Ultra-low-dose spine and pelvis CT demonstrates better fracture detection when compared with radiographs. • The effective dose of ultra-low-dose spine and pelvis CT scan and radiographs is comparable. • Replacement of radiographs by ULD CT in daily practice for trauma patients is an option to consider and should be evaluated by a randomized trial.


Assuntos
Pelve , Tomografia Computadorizada por Raios X , Teorema de Bayes , Humanos , Pelve/diagnóstico por imagem , Doses de Radiação , Radiografia , Sensibilidade e Especificidade
8.
J Endovasc Ther ; 28(1): 63-69, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33025866

RESUMO

PURPOSE: To quantify the hemodynamic consequences of thoracic endovascular aortic repair (TEVAR) by comparing the preoperative and postoperative wall shear stress (WSS) and vorticity profiles on computational fluid dynamics (CFD) simulations. MATERIALS AND METHODS: The pre- and postoperative computed tomography (CT) scans from 20 consecutive patients (median age 69 years, range 20-87) treated for different thoracic aortic pathologies (11 aneurysms, 5 false aneurysms, 3 penetrating ulcers, and 1 traumatic aortic rupture) were segmented to construct patient-specific CFD models using a meshless code. The simulations were run over the cardiac cycle, and the WSS and vorticity values measured at the proximal and distal landing zones were compared. RESULTS: The CFD runs provided 4-dimensional simulations of blood flow in all patients. WSS and vorticity profiles at the proximal landing zone (located in zones 0-3 in 15 patients) varied in 18 and 20 of the cases, respectively; WSS was increased in 11 cases and the vorticity in 9. Pre- and postoperative WSS median values were 4.19 and 4.90 Pa, respectively. Vorticity median values were 40.38 and 39.17 Hz, respectively. CONCLUSION: TEVAR induces functional alterations in the native thoracic aorta, though the prognostic significance of these changes is still unknown. CFD appears to be a valuable tool to explore aortic hemodynamics, and its application in a larger series would help define a predictive role for these hemodynamic assessments.


Assuntos
Hidrodinâmica , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Modelos Cardiovasculares , Stents , Resultado do Tratamento , Adulto Jovem
9.
J Vasc Interv Radiol ; 32(2): 247-255, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33248919

RESUMO

PURPOSE: To evaluate the feasibility of prostatic artery embolization in patients with low-risk prostate cancer (PC) under active surveillance (AS). METHODS: This monocentric prospective pilot study, running from June 2018 to June 2019, included 10 patients with low-risk PC under AS, median age 72 years (range, 62-77 years), with a unilateral focal lesion visible on magnetic resonance (MR) imaging, with Prostate Imaging Reporting and Data System v2 score ≥3/5 confirmed by multiparametric MR imaging-targeted biopsy and Gleason score 6. The patients underwent unilateral prostatic artery embolization with 300-500 µm Embospheres in the affected prostatic lobe. The primary endpoint was technical feasibility (prostate and no off-target ischemia in the imaging). The secondary endpoints included safety, negative biopsies/MR imaging response/functional outcomes at 6 months, and oncologic efficacy at 1 year. RESULTS: Embolization was successfully achieved in all patients; prostate ischemia was confirmed on multiparametric MR imaging, and no off-target ischemia was reported. No major complications were reported. Four patients (40%) presented with both negative targeted and systematic biopsies at 6 months. No lesions were seen on the MR imaging in 30% of patients. The mean International Prostate Symptom Score and International Index of Erectile Function score were 7 and 19 and 5 and 20 at baseline and 6 months, respectively, with no significant difference. Nine patients (90%) were still under AS at 1 year. One patient (10%) had PC progression outside the target lesion and was switched over to curative radiotherapy. CONCLUSIONS: Prostatic artery embolization is feasible and appears safe for prostate cancer patients under AS, with no impact on erectile function or continence status. These results justify the pursuit of further studies.


Assuntos
Embolização Terapêutica , Próstata/irrigação sanguínea , Neoplasias da Próstata/irrigação sanguínea , Neoplasias da Próstata/terapia , Conduta Expectante , Idoso , Embolização Terapêutica/efeitos adversos , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
J Appl Clin Med Phys ; 22(8): 243-254, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34312979

RESUMO

PURPOSE: To compare the spectral performance of four combinations of kVp available in a third generation dual-source CT (DSCT) on abdominal imaging. METHODS: An image-quality phantom was scanned with a DSCT using four kVp pairs (tube "A" voltage/tube "B" voltage): 100/Sn150 kVp, 90/Sn150 kVp, 80/Sn150 kVp, and 70/Sn150 kVp, classic parameters and dose level for abdomen examination (CTDIvol : 11 mGy). The noise power spectrum (NPS) and the task-based transfer function (TTF) of two inserts were computed on virtual monochromatic images (VMIs) at 40/50/60/70 keV and for mixed, low-, and high-kVp images. Detectability index (d') was computed on VMIs and mixed images to model the detection task of liver metastasis (LM) and hepatocellular carcinoma (HCC). Iodine quantification accuracy was assessed using the Root Mean Square Deviation (RMSDiodine ) and the iodine bias (IB). RESULTS: Noise magnitude decreased by -55%± 0% between 40 and 70 keV for all kVp pairs. Compared to 70/Sn150 kVp, noise magnitude was increased by 9% ± 0% with 80/Sn150 kVp, by 16% ± 1% with 90/Sn150 kVp and by 24%± 1% with 100/Sn150 kVp. The average NPS spatial frequency (fav ) shifted toward higher frequencies as energy level increased for all kVp pairs. Lowest fav values were found for 70/Sn150 kVp and highest for 100/Sn150 kVp. The value of TTF at 50% (f50 ) shifted toward lower frequencies with increasing energy level. The highest f50  values occurred for 100/Sn150 kVp and the lowest for 80/Sn150 kVp. For both lesions, d' was highest for 70/Sn150 kVp and lowest for 100/Sn150 kVp. Compared to 70/Sn150 kVp, d' decreased by -6% ± 3% with 80/Sn150 kVp, by -11% ± 2% with 90/Sn150 kVp and by -13%± 2% with 100/Sn150 kVp. For all acquisitions, the RSMDiodine and IB were the lowest for 100/Sn150 kVp (0.29 ± 0.10 mg/ml and 0.88 ± 0.30 mg/ml, respectively) and increased when the tube "A" voltage decreased (2.34 ± 0.29 mg/ml for 70/Sn150 kVp and 7.42 ± 0.51 mg/ml respectively). CONCLUSION: 70/Sn150 kVp presented the lowest image noise and highest detectability in VMIs of two small focal liver lesions. 100/Sn150 kVp presented the lowest image noise on mixed images and highest accuracy of iodine quantification in iodine images.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Abdome/diagnóstico por imagem , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Imagens de Fantasmas , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
11.
Eur Radiol ; 30(7): 3951-3959, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32100091

RESUMO

OBJECTIVES: To assess the impact on image quality and dose reduction of a new deep learning image reconstruction (DLIR) algorithm compared with a hybrid iterative reconstruction (IR) algorithm. METHODS: Data acquisitions were performed at seven dose levels (CTDIvol : 15/10/7.5/5/2.5/1/0.5 mGy) using a standard phantom designed for image quality assessment. Raw data were reconstructed using the filtered back projection (FBP), two levels of IR (ASiR-V50% (AV50); ASiR-V100% (AV100)), and three levels of DLIR (TrueFidelity™ low, medium, high). Noise power spectrum (NPS) and task-based transfer function (TTF) were computed. Detectability index (d') was computed to model a large mass in the liver, a small calcification, and a small subtle lesion with low contrast. RESULTS: NPS peaks were higher with AV50 than with all DLIR levels and only higher with DLIR-H than with AV100. The average NPS spatial frequencies were higher with DLIR than with IR. For all DLIR levels, TTF50% obtained with DLIR was higher than that with IR. d' was higher with DLIR than with AV50 but lower with DLIR-L and DLIR-M than with AV100. d' values were higher with DLIR-H than with AV100 for the small low-contrast lesion (10 ± 4%) and in the same range for the other simulated lesions. CONCLUSIONS: New DLIR algorithm reduced noise and improved spatial resolution and detectability without changing the noise texture. Images obtained with DLIR seem to indicate a greater potential for dose optimization than those with hybrid IR. KEY POINTS: • This study assessed the impact on image quality and radiation dose of a new deep learning image reconstruction (DLIR) algorithm as compared with hybrid iterative reconstruction (IR) algorithm. • The new DLIR algorithm reduced noise and improved spatial resolution and detectability without perceived alteration of the texture, commonly reported with IR. • As compared with IR, DLIR seems to open further possibility of dose optimization.


Assuntos
Algoritmos , Aprendizado Profundo , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Doses de Radiação
12.
Eur Radiol ; 30(9): 5071-5081, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32333144

RESUMO

OBJECTIVES: To validate the performance of an automatic tool to estimate a patient's peak skin dose (PSD) and a skin dose map from data collected by a radiation dose management system (RDMS) during interventional procedures. METHODS: In total, 288 eligible consecutive patients undergoing abdominopelvic embolisation or planned coronary angioplasty using radiochromic films were screened between June 2018 and March 2019. For 98 included patients, PSD was measured using radiochromic films (PSDFilm) and computed by RDMS (PSDRDMS) using one flat and two anthropomorphic phantoms. Statistical concordance between PSDFilm and PSDRDMS was computed with Lin's concordance correlation coefficient and clinical concordance with the Bland and Altman graphic; values were compared using the paired Mann-Whitney-Wilcoxon test. RESULTS: In total, 190/288 patients were excluded and 98 patients were analysed (69 men, mean age 66 ± 14 years). The PSDFilm median (1st; 3rd quartile) was 0.59 Gy (0.40; 1.08). PSDRDMS was 0.62 Gy (0.43; 1.22) for the flat phantom and 0.62 Gy (0.42; 1.19) for anthropomorphic phantoms. The concordance between PSDFilm and PSDRDMS was good for both phantoms (flat: 0.94 [0.91; 0.95]; anthropomorphic 0.94 [0.91; 0.96]). Compared with the values of PSDFilm, the values of PSDRDMS were significantly increased by 5% (- 4%; 16%) for flat phantom (p = 0.001) and 7% (- 6%; 22%) for anthropomorphic phantoms (p = 0.002) for vascular procedures and 9% (- 4%; 26%, p = 0.01) and 6% (- 4%; 23%, p = 0.02) for cardiac procedures, respectively. Dose map representations matched for most patients. The gaps identified were due to table displacement during fluoroscopy events and the use of a wedge filter. CONCLUSIONS: The RDMS skin dose map tool allowed the computation of the PSD and skin dose distribution for all patients with fewer constraints than radiochromic films. However, the computed PSD was overestimated, increasing the number of patients requiring follow-up. KEY POINTS: • A good concordance correlation was identified between the peak skin dose (PSD) values measured with radiochromic films and estimated with the radiation dose management system (RDMS) skin dose map tool. • Differences were related to table displacement during fluoroscopy events and the use of a wedge filter, which are not accounted in the Digital Imaging and Communications in Medicine Radiation Dose Structured Reports. • For all procedures, the estimated PSDs were significantly higher than the measured PSDs by 5% (- 4%; 18%) for flat phantom (p < 0.001) and 6% (- 5%; 22%) for anthropomorphic phantoms (p < 0.001).


Assuntos
Fluoroscopia/métodos , Doses de Radiação , Radiometria/métodos , Pele , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Imagens de Fantasmas , Dosímetros de Radiação
13.
Eur Radiol ; 30(12): 6537-6544, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32621241

RESUMO

PURPOSE: To determine the impact of the COVID-19 on the CT activities in French radiological centers during the epidemic peak. MATERIALS AND METHODS: A cross-sectional prospective CT scan survey was conducted between March 16 and April 12, 2020, in accordance with the local IRB. Seven hundred nine radiology centers were invited to participate in a weekly online survey. Numbers of CT examinations related to COVID-19 including at least chest (CTcovid) and whole chest CT scan activities (CTchest) were recorded each week. A sub-analysis on French departments was performed during the 4 weeks of the study. The impact of the number of RT-PCRs (reverse transcriptase polymerase chain reactions) on the CT workflow was tested using two-sample t test and Pearson's test. RESULTS: Five hundred seventy-seven structures finally registered (78%) with mean response numbers of 336 ± 18.9 (323; 351). Mean CTchest activity per radiologic structure ranged from 75.8 ± 133 (0-1444) on week 12 to 99.3 ± 138.6 (0-1147) on week 13. Mean ratio of CTcovid on CTchest varied from 0.36 to 0.59 on week 12 and week 14 respectively. There was a significant relationship between the number of RT-PCR performed and the number of CTcovid (r = 0.73, p = 3.10-16) but no link with the number of positive RT-PCR results. CONCLUSION: In case of local high density COVID-19, CT workflow is strongly modified and redirected to the management of these specific patients. KEY POINTS: • Over the 4-week survey period, 117,686 chest CT (CTtotal) were performed among the responding centers, including 61,784 (52%) CT performed for COVID-19 (CTcovid). • Across the country, the ratio CTcovid/CTtotal varied from 0.36 to 0.59 and depended significantly on the local epidemic density (p = 0.003). • In clinical practice, in a context of growing epidemic, in France, chest CT was used as a surrogate to RT-PCR for patient triage.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico , Pandemias , Pneumonia Viral/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Triagem/métodos , Adulto , COVID-19 , Infecções por Coronavirus/epidemiologia , Estudos Transversais , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonia Viral/epidemiologia , Estudos Prospectivos , SARS-CoV-2 , Inquéritos e Questionários
16.
Eur Radiol ; 27(10): 4281-4290, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28289939

RESUMO

OBJECTIVES: A national retrospective survey on patient doses was performed by the French Society of Medical physicists to assess reference levels (RLs) in interventional radiology as required by the European Directive 2013/59/Euratom. METHODS: Fifteen interventional procedures in neuroradiology, vascular radiology and osteoarticular procedures were analysed. Kerma area product (KAP), fluoroscopy time (FT), reference air kerma and number of images were recorded for 10 to 30 patients per procedure. RLs were calculated as the 3rd quartiles of the distributions. RESULTS: Results on 4600 procedures from 36 departments confirmed the large variability in patient dose for the same procedure. RLs were proposed for the four dosimetric estimators and the 15 procedures. RLs in terms of KAP and FT were 90 Gm.cm2 and 11 mins for cerebral angiography, 35 Gy.cm2 and 16 mins for biliary drainage, 75 Gy.cm2 and 6 mins for lower limbs arteriography and 70 Gy.cm2 and 11 mins for vertebroplasty. For these four procedures, RLs were defined according to the complexity of the procedure. For all the procedures, the results were lower than most of those already published. CONCLUSIONS: This study reports RLs in interventional radiology based on a national survey. Continual evolution of practices and technologies requires regular updates of RLs. KEY POINTS: • Delivered dose in interventional radiology depends on procedure, practice and patient. • National RLs are proposed for 15 interventional procedures. • Reference levels (RLs) are useful to benchmark practices and optimize protocols. • RLs are proposed for kerma area product, air kerma, fluoroscopy time and number of images. • RLs should be adapted to the procedure complexity and updated regularly.


Assuntos
Doses de Radiação , Radiografia Intervencionista/métodos , Radiologia Intervencionista/métodos , França , Humanos , Proteção Radiológica/métodos , Estudos Retrospectivos
17.
Eur Radiol ; 26(4): 959-68, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26201292

RESUMO

OBJECTIVES: To evaluate white matter (WM) integrity in neurologically asymptomatic antiphospholipid syndrome (APS) using diffusion tensor imaging (DTI) in women with no thrombotic history but with pregnancy loss. METHODS: Imaging was performed with a 3 T scanner using structural MRI (T1-weighted, fluid attenuation inversion recovery [FLAIR]) and DTI sequences in 66 women with APS and a control group of 17 women. Women with APS were further categorized as positive for lupus anticoagulant (LA) and/or aß2GPI-G antibodies (LA/aß2GPI-G-positive, N = 29) or negative (LA/aß2GPI-G-negative, N = 37) for both. Tract-based spatial statistics of standard DTI-based indices were compared among groups. RESULTS: Women with APS had significantly lower fractional anisotropy (p < 0.05) associated with higher mean diffusivity and radial diffusivity compared to the control group. There was a stronger association of abnormal DTI features among women positive for LA and/or aß2GPI-IgG antibodies than those who were negative. CONCLUSIONS: DTI appears sensitive to subtle WM changes in women with APS with no thrombotic history but with pregnancy loss, compatible with alterations in axonal structure and in the myelin sheath. The preferential association of abnormal DTI features with the two most pathogenic aPLAbs reinforces the pathophysiological relevance of our findings. KEY POINTS: • APS women exhibited lower FA and higher MD and RD than controls. • WM impairments are more severe in patients with positive LA or aß2GPI-IgG. • An association exists between abnormal DTI features and LA or aß2GPI-IgG positivity. • Diffusion tensor imaging detects microstructural white matter abnormalities in APS women.


Assuntos
Aborto Espontâneo/patologia , Síndrome Antifosfolipídica/patologia , Encefalopatias/patologia , Substância Branca/patologia , Adulto , Anisotropia , Estudos de Casos e Controles , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Gravidez
19.
JAMA ; 313(16): 1627-35, 2015 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-25919526

RESUMO

IMPORTANCE: Although retrievable inferior vena cava filters are frequently used in addition to anticoagulation in patients with acute venous thromboembolism, their benefit-risk ratio is unclear. OBJECTIVE: To evaluate the efficacy and safety of retrievable vena cava filters plus anticoagulation vs anticoagulation alone for preventing pulmonary embolism recurrence in patients presenting with acute pulmonary embolism and a high risk of recurrence. DESIGN, SETTING, AND PARTICIPANTS: Randomized, open-label, blinded end point trial (PREPIC2) with 6-month follow-up conducted from August 2006 to January 2013. Hospitalized patients with acute, symptomatic pulmonary embolism associated with lower-limb vein thrombosis and at least 1 criterion for severity were assigned to retrievable inferior vena cava filter implantation plus anticoagulation (filter group; n = 200) or anticoagulation alone with no filter implantation (control group; n = 199). Initial hospitalization with ambulatory follow-up occurred in 17 French centers. INTERVENTIONS: Full-dose anticoagulation for at least 6 months in all patients. Insertion of a retrievable inferior vena cava filter in patients randomized to the filter group. Filter retrieval was planned at 3 months from placement. MAIN OUTCOMES AND MEASURES: Primary efficacy outcome was symptomatic recurrent pulmonary embolism at 3 months. Secondary outcomes were recurrent pulmonary embolism at 6 months, symptomatic deep vein thrombosis, major bleeding, death at 3 and 6 months, and filter complications. RESULTS: In the filter group, the filter was successfully inserted in 193 patients and was retrieved as planned in 153 of the 164 patients in whom retrieval was attempted. By 3 months, recurrent pulmonary embolism had occurred in 6 patients (3.0%; all fatal) in the filter group and in 3 patients (1.5%; 2 fatal) in the control group (relative risk with filter, 2.00 [95% CI, 0.51-7.89]; P = .50). Results were similar at 6 months. No difference was observed between the 2 groups regarding the other outcomes. Filter thrombosis occurred in 3 patients. CONCLUSIONS AND RELEVANCE: Among hospitalized patients with severe acute pulmonary embolism, the use of a retrievable inferior vena cava filter plus anticoagulation compared with anticoagulation alone did not reduce the risk of symptomatic recurrent pulmonary embolism at 3 months. These findings do not support the use of this type of filter in patients who can be treated with anticoagulation. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00457158.


Assuntos
Embolia Pulmonar/prevenção & controle , Filtros de Veia Cava , Tromboembolia Venosa/complicações , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Remoção de Dispositivo , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/etiologia , Recidiva , Risco , Medição de Risco
20.
Surg Radiol Anat ; 37(7): 731-41, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25552237

RESUMO

PURPOSE: With a view to developing a tool for predicting the behavior of soft tissues during plastic surgery procedures, we looked for the existence of homologies in the overall pattern of organization of the skin/subcutaneous tissue complex between various body parts, using high-resolution in vivo imaging methods and data available in the literature. METHODS: 3T MRI scanning sequences were performed using appropriate radiofrequency coils on the face, thorax, breast, abdomen and lower extremity of six healthy volunteers. The radiological findings were segmented and converted into volumetric data. RESULTS: The superficial and deep adipose tissue was found to be clearly separated by an intermediate layer called stratum membranosum or superficial fascia. This continuous layer covered all the anatomical parts of the body examined. It was found to have several components in the trunk and limbs and to form a continuous layer with the superficial muscular aponeurotic system in the face. A retaining connective network consisting of superficial and deep retinacula cutis detected in all the regions investigated sometimes formed more densely packed structures playing the role of skin ligaments. CONCLUSION: The results of a 3T MRI study on subcutaneous tissue showed the existence of a common pattern of organization of the skin-subcutaneous tissue complex in the various parts of the body studied. This general model is subject to quantitative variations and tissue differentiation processes promoting the sliding or contractility of the supporting tissue. Three-dimensional reconstructions were obtained by post-processing the MRI images and will be used to perform pre-surgical simulations by settings a generic model that can be adapted to the different localization of the human body in a procedural way.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Pele/anatomia & histologia , Tela Subcutânea/anatomia & histologia , Tecido Adiposo/anatomia & histologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Sensibilidade e Especificidade , Adulto Jovem