Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(7): 1480-1488, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35510408

RESUMO

INTRODUCTION: Pulsed-field ablation (PFA), an ablative method that causes cell death by irreversible electroporation, has potential safety advantages over radiofrequency ablation and cryoablation. Pulmonary vein (PV) isolation was performed in a porcine model to characterize safety and performance of a novel, fully-integrated biphasic PFA system comprising a multi-channel generator, variable loop circular catheter, and integrated PFA mapping software module. METHODS: Eight healthy porcine subjects were included. To evaluate safety, multiple ablations were performed, including sites not generally targeted for therapeutic ablation, such as the right inferior PV lumen, right superior PV ostium, and adjacent to the esophagus and phrenic nerve. To evaluate the efficacy, animals were recovered, followed for 30(±3) days, then re-mapped. Gross pathological and histopathological examinations assessed procedural injuries, chronic thrombosis, tissue ablation, penetration depth, healing, and inflammatory response. RESULTS: All eight animals survived follow-up. PV narrowing was not observed acutely nor at follow-up, even when ablation was performed deep to the PV ostium. No injury was seen grossly or histologically in adjacent structures. All PVs were durably isolated, confirmed by bidirectional block at re-map procedure. Histological examination showed complete, transmural necrosis around the circumference of the ablated section of right PVs. CONCLUSION: This preclinical evaluation of a fully-integrated PFA system demonstrated effective and durable ablation of cardiac tissue and PV isolation without collateral damage to adjacent structures, even when ablation was performed in more extreme settings than those used therapeutically. Histological staining confirmed complete transmural cell necrosis around the circumference of the PV ostium at 30 days.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Átrios do Coração , Humanos , Necrose/patologia , Necrose/cirurgia , Suínos , Resultado do Tratamento
2.
Circ Arrhythm Electrophysiol ; 15(7): e010661, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35763432

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) is a tissue-selective, nonthermal cardiac ablation modality. A novel PFA ablation system consisted of a multichannel irreversible electroporation generator system and a multielectrode circular irreversible electroporation catheter has been developed for catheter ablation. To understand the progression and immediate impacts of PFA, this study evaluated the subchronic (7±3 day) and chronic (30±3 day) safety and performance of the novel PFA system when simulating pulmonary vein and superior vena cava isolation in a porcine beating heart model. METHODS: Ten swine models were divided into subchronic (n=6) and chronic cohorts (n=4). Lesions were performed within the right and left atrium to conduct right pulmonary veins and superior vena cava isolations, in addition to creating stacked lesions in the left atrium roof and right atrium posterior wall. RESULTS: Acute pulmonary vein and superior vena cava isolation were achieved in 10 out of 10 swine and demonstrated 100% lesion durability in both cohorts, including sustained elimination of electrical activity at the left atrium roof and right atrium posterior wall. Histology demonstrated that all the cardiac sites ablated showed discrete zones of loss of myocardial fibers or smooth muscle cells with preservation of the tissue architecture with resultant fibrocellular replacement, neovascularization, and neocollagen deposition. Mineralization findings were present in association with residual necrotic muscle fibers. Only in 7 days group, areas of mineralization were frequently associated with inflammation. There were no treatment-related changes in other tissues, including complete sparing of the phrenic nerve. CONCLUSIONS: Pulsed-field ablation for pulmonary vein and superior vena cava isolation with the novel PFA system was feasible, safe with myocardial-specific ablative effect. Durable lesions were observed at the target areas. with inflammation phenomena mainly documented at 7 days.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Eletroporação , Seguimentos , Inflamação , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Suínos , Veia Cava Superior/patologia , Veia Cava Superior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA