Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Appl Clin Med Phys ; 17(1): 121-131, 2016 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-26894342

RESUMO

The purpose of this study was to describe the clinical implementation of a magnetic resonance image (MRI)-based approach for adaptive intracavitary brachytherapy (ICBT) of cervix cancer patients. Patients were implanted with titanium tandem and colpostats. MR imaging was performed on a 1.5-T Philips scanner using T2-weighted (T2W), proton-density weighted (PDW), and diffusion-weighted (DW) imaging sequences. Apparent diffusion coefficient (ADC) maps were generated from the DW images. All images were fused. T2W images were used for the definition of organs at risk (OARs) and dose points. ADC maps in conjunction with T2W images were used for target delineation. PDW images were used for applicator definition. Forward treatment planning was performed using standard source distribution rules normalized to Point A. Point doses and dose-volume parameters for the tumor and OARs were exported to an automated dose-tracking application. Brachytherapy doses were adapted for tumor shrinkage and OAR variations during the course of therapy. The MRI-based ICBT approach described here has been clinically implemented and is carried out for each brachytherapy fraction. Total procedure time from patient preparation to delivery of treatment is typically 2 hrs. Implementation of our tech-nique for structure delineation, applicator definition, dose tracking, and adaptation is demonstrated using treated patient examples. Based on published recommendations and our clinical experience in the radiation treatment of cervix cancer patients, we have refined our standard approach to ICBT by 1) incorporating a multisequence MRI technique for improved visualization of the target, OARs, and applicator, and by 2) implementing dose adaptation by use of automated dose tracking tools.


Assuntos
Carcinoma in Situ/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias do Colo do Útero/patologia , Carcinoma in Situ/radioterapia , Feminino , Humanos , Estadiamento de Neoplasias , Neoplasias do Colo do Útero/radioterapia
2.
Brachytherapy ; 17(1): 31-39, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28818442

RESUMO

PURPOSE: Episcleral plaque brachytherapy (EPB) planning is conventionally based on approximations of the implant geometry with no volumetric imaging following plaque implantation. We have developed an MRI-based technique for EPB treatment planning and dose delivery verification based on the actual patient-specific geometry. METHODS AND MATERIALS: MR images of 6 patients, prescribed 85 Gy over 96 hours from Collaborative Ocular Melanoma Study-based EPB, were acquired before and after implantation. Preimplant and postimplant scans were used to generate "preplans" and "postplans", respectively. In the preplans, a digital plaque model was positioned relative to the tumor, sclera, and nerve. In the postplans, the same plaque model was positioned based on the imaged plaque. Plaque position, point doses, percentage of tumor volume receiving 85 Gy (V100), and dose to 100% of tumor volume (Dmin) were compared between preplans and postplans. All isodose plans were computed using TG-43 formalism with no heterogeneity corrections. RESULTS: Shifts and tilts of the plaque ranged from 1.4 to 8.6 mm and 1.0 to 3.8 mm, respectively. V100 was ≥97% for 4 patients. Dmin for preplans and postplans ranged from 83 to 118 Gy and 45 to 110 Gy, respectively. Point doses for tumor apex and base were all found to decrease from the preimplant to the postimplant plan, with mean differences of 16.7 ± 8.6% and 30.5 ± 11.3%, respectively. CONCLUSIONS: By implementing MRI for EPB, we eliminate reliance on approximations of the eye and tumor shape and the assumption of idealized plaque placement. With MRI, one can perform preimplant as well as postimplant imaging, facilitating EPB treatment planning based on the actual patient-specific geometry and dose-delivery verification based on the imaged plaque position.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética , Melanoma/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Uveais/radioterapia , Humanos , Radioisótopos do Iodo/uso terapêutico , Melanoma/diagnóstico por imagem , Dosagem Radioterapêutica , Esclera , Neoplasias Uveais/diagnóstico por imagem
3.
Brachytherapy ; 3(3): 136-40, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15533805

RESUMO

PURPOSE: An analysis of the effect of stranded (125)I and loose (predominantly (103)Pd) sources on dosimetric outcomes of brachytherapy of the prostate. METHODS AND MATERIALS: Between September 1998 and December 2003, 473 patients were treated with brachytherapy for biopsy-proven carcinoma of the prostate. Of these, 337 (71%) procedures were performed using free seeds placed with a Mick applicator. Beginning in April 2002, a program of stranded (125)I sources (RAPIDStrand) was implemented; 136 (29%) patients were treated via this approach. Dosimetric variables were collected, as were events of urinary retention. RESULTS: Mean V100 values for the stranded (125)I approach were greater than those for free seeds (p < 0.0005), whether (125)I or (103)Pd (p < 0.005). Use of the strand was the most significant determinant of V100 of all variables examined. The stranded (125)I approach was also associated with higher mean D90 values and lower V150-urethral doses. CONCLUSIONS: Use of stranded (125)I was associated with superior dosimetric outcomes in this group of patients.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Monitoramento de Radiação , Humanos , Masculino , Períneo , Reto , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA