Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Echocardiography ; 33(9): 1344-52, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27677642

RESUMO

BACKGROUND: Cardiac infiltration is an important cause of death in sarcoidosis. Transthoracic echocardiography (TTE) has limited sensitivity for the detection of cardiac sarcoidosis (CS). Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is used to diagnose CS but has limitations of cost and availability. We sought to determine whether TTE-derived global longitudinal strain (GLS) may be used to identify individuals with CS, despite preserved left ventricular ejection fraction (LVEF), and whether abnormal GLS is associated with major cardiovascular events (MCE). METHODS: We studied 31 patients with biopsy-proven extra-cardiac sarcoidosis, LVEF>50% and LGE on CMR (CS+ group), and 31 patients without LGE (CS- group), matched by age, sex, and severity of lung disease. GLS was measured using vendor-independent speckle tracking software. Parameters of left and right ventricular systolic and diastolic function were also studied. Receiver-operating characteristic curves were used to identify GLS cutoff for CS detection, and Kaplan-Meier plots to determine the ability of GLS to predict MCE. RESULTS: LGE was associated with reduced GLS (-19.6±1.9% in CS- vs -14.7±2.4% in CS+, P<.01) and with reduced E/A ratio (1.1±0.3 vs 0.9±0.3, respectively, P =.01). No differences were noted in other TTE parameters. GLS magnitude inversely correlated with LGE burden (r=-.59). GLS cutoff of -17% showed sensitivity and specificity 94% for detecting CS. Patients who experienced MCE had worse GLS than those who did not (-13.4±0.9% vs -17.7±0.4%, P=.0003). CONCLUSIONS: CS is associated with significantly reduced GLS in the presence of preserved LVEF. GLS measurements may become part of the TTE study performed to screen for CS.


Assuntos
Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Módulo de Elasticidade , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sarcoidose/fisiopatologia , Sensibilidade e Especificidade , Volume Sistólico
2.
Pacing Clin Electrophysiol ; 37(4): 464-72, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24237034

RESUMO

BACKGROUND: Ventricular arrhythmias (VAs) in the months following continuous-flow left ventricular assist devices (LVADs) implantation are common and associated with increased morbidity and mortality. We sought to evaluate for changes in implantable cardioverter defibrillator (ICD) performance following LVAD implantation. METHODS: We retrospectively reviewed the ICD interrogation reports and medical records of patients who received a continuous-flow LVAD at the University of Chicago Medical Center between January 2008 and December 2010. Patients who did not have an ICD prior to LVAD implantation were excluded. RESULTS: Forty-four patients were included. Median right ventricular lead sensing amplitude decreased from 10.0 (interquartile range 7.6-13.6) mV prior to LVAD to 7.9 (5.9-9.3) mV after LVAD implantation (P < 0.01). Significant reductions in sensing threshold were associated with smaller lead diameters, smaller pace/sense electrode surface areas, and Medtronic ICD leads (Medtronic Inc., Minneapolis, MN, USA). Lead impedance and capture threshold did not change significantly. ICD-related adverse events occurred in 30% of patients and led to ICD modification in 18% of patients. CONCLUSIONS: Implantation of a continuous-flow LVAD is associated with changes in the performance of preexisting ICDs. ICD-related adverse events were encountered following LVAD implantation in this cohort, and at times resulted in invasive and noninvasive ICD system modification. Reductions in ICD sensing threshold after LVAD implantation may adversely affect ICD function. Formal ICD interrogation in addition to the regular follow-up testing is warranted post-LVAD.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Insuficiência Cardíaca/prevenção & controle , Coração Auxiliar/efeitos adversos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle , Análise de Falha de Equipamento , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 35(3): e62-4, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20883512

RESUMO

Long QT eight (LQT8), otherwise known as Timothy syndrome (TS), is a genetic disorder causing hyper-activation of the L-type calcium channel Cav 1.2. This calcium load and the resultant increase in the QT interval provide the substrate for ventricular arrhythmias. We previously presented a case in a patient with TS who had a profound decrease in his burden of ventricular arrhythmias after institution of an L-type calcium channel blocker. Although this patient's arrhythmia burden had decreased, he displayed an increasing burden of atrial fibrillation and still had bouts of ventricular fibrillation requiring defibrillator therapy. Basic research has recently shown that ranolazine, a multipotent ion-channel blocker, may be of benefit in patients with LQT8 syndrome. This case report details the decrease of atrial fibrillation and ventricular fibrillation events in our LQT8 patient with the addition of ranolazine.


Assuntos
Acetanilidas/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Síndrome do QT Longo/tratamento farmacológico , Piperazinas/uso terapêutico , Sindactilia/tratamento farmacológico , Fibrilação Ventricular/tratamento farmacológico , Adulto , Transtorno Autístico , Quimioterapia Combinada , Humanos , Masculino , Ranolazina , Resultado do Tratamento , Verapamil/uso terapêutico
4.
N Engl J Med ; 357(24): 2461-71, 2007 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-17986493

RESUMO

BACKGROUND: Indications for cardiac-resynchronization therapy (CRT) in patients with heart failure include a prolonged QRS interval (> or =120 msec), in addition to other functional criteria. Some patients with narrow QRS complexes have echocardiographic evidence of left ventricular mechanical dyssynchrony and may also benefit from CRT. METHODS: We enrolled 172 patients who had a standard indication for an implantable cardioverter-defibrillator. Patients received the CRT device and were randomly assigned to the CRT group or to a control group (no CRT) for 6 months. The primary end point was the proportion of patients with an increase in peak oxygen consumption of at least 1.0 ml per kilogram of body weight per minute during cardiopulmonary exercise testing at 6 months. RESULTS: At 6 months, the CRT group and the control group did not differ significantly in the proportion of patients with the primary end point (46% and 41%, respectively). In a prespecified subgroup with a QRS interval of 120 msec or more, the peak oxygen consumption increased in the CRT group (P=0.02), but it was unchanged in a subgroup with a QRS interval of less than 120 msec (P=0.45). There were 24 heart-failure events requiring intravenous therapy in 14 patients in the CRT group (16.1%) and 41 events in 19 patients in the control group (22.3%), but the difference was not significant. CONCLUSIONS: CRT did not improve peak oxygen consumption in patients with moderate-to-severe heart failure, providing evidence that patients with heart failure and narrow QRS intervals may not benefit from CRT. (ClinicalTrials.gov number, NCT00132977 [ClinicalTrials.gov].).


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/etiologia , Estudos Cross-Over , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Qualidade de Vida , Falha de Tratamento
5.
J Cardiovasc Electrophysiol ; 21(4): 423-7, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19925604

RESUMO

INTRODUCTION: The purpose of this study was to determine the safety and efficacy of using a novel radiofrequency (RF) powered transseptal needle to perform transseptal puncture (TSP). METHODS: TSP was performed in 35 consecutive patients undergoing left-sided catheter ablation (mean age = 51 years; male = 71%) using a RF powered transseptal needle (NRG, Adult Large and Standard Curve C1, 71 cm, Baylis Medical Company, Inc.). Prior TSP had been performed in 34% of patients. The transseptal apparatus was positioned with the tip of the dilator engaged in the fossa ovalis. RF energy was delivered to the tip of the transseptal needle using a proprietary RF generator at 10 W for 2 seconds as gentle pressure was applied to the needle. RESULTS: In 5 of the 41 TSPs, the needle crossed into the left atrium before RF energy was delivered. In 35 of the remaining 36 punctures, the needle was successfully advanced into the left atrium after application of RF current. In 1 patient, the TSP with the powered needle was unsuccessful but was accomplished using a standard needle. The only complication was a transient right atrial thrombus, which occurred in 2 patients. CONCLUSION: A radiofrequency powered transseptal needle can be used to perform TSP safely and successfully without the need for significant mechanical force, even in patients who have undergone TSP previously. Additional studies are needed to determine whether a powered transseptal needle should be used routinely.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Septos Cardíacos/cirurgia , Agulhas , Punções/instrumentação , Adolescente , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento , Adulto Jovem
6.
J Electrocardiol ; 43(5): 459-62, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20728020

RESUMO

The Brugada syndrome (BS) accounts for approximately 20% of cases of sudden cardiac death in patients with structurally normal hearts. The electrophysiologic basis for ST-segment elevation in the precordial electrocardiogram (ECG) leads that characterize the Brugada phenotype and its strong linkage to ventricular tachycardia (VT)/ventricular fibrillation is still a subject of controversy. Electrocardiographic manifestations of the syndrome have been attributed to one of two basic mechanisms: (1) conduction delay in the right ventricular (RV) epicardial-free wall in the region of the outflow tract or (2) premature repolarization of the RV epicardial action potential secondary to loss of the action potential dome. Signal-averaged ECG recordings have demonstrated late potentials that extend beyond the QRS complex in patients with the BS, especially in the anterior wall of the RV outflow tract. The basis for these epicardial late potentials remains a subject of interest among basic and clinical electrophysiologists. Endocardial late potentials in BS are even less well understood. We present a case of a patient with Brugada syndrome with a distinct endocardial late potential in the high ventricular septum coinciding with the ST-segment elevation. We discuss the possible mechanisms for this intracardiac finding and its clinical significance. We also review the effect of isoproterenol infusion on both the late potential and the surface ECG.


Assuntos
Síndrome de Brugada/fisiopatologia , Septo Interventricular/fisiopatologia , Adulto , Síndrome de Brugada/terapia , Desfibriladores Implantáveis , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Masculino
7.
J Cardiovasc Electrophysiol ; 20(4): 429-35, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19017342

RESUMO

INTRODUCTION: Insulation defects are a leading cause of transvenous lead failure. The purpose of this study was to determine the effects of electrocautery on transvenous lead insulation materials. METHODS: A preparation was done to simulate dissection of a transvenous lead from tissues. Radiofrequency energy was delivered using a standard cautery blade at outputs of 10, 20, and 30 W, for 3 and 6 seconds, using parallel and perpendicular blade orientations on leads with outermost insulations of silicone rubber, polyurethane, and silicone-polyurethane copolymer. Damage to each lead segment was classified after visual and microscopic analysis. RESULTS: Significant insulation damage occurred to almost all polyurethane leads. Full insulation breaches were observed with 30 W regardless of application duration with a parallel direction and with all power outputs with a perpendicular direction. Thermal insulation damage to copolymer insulation was similar to that of the polyurethane leads. In contrast, there was no thermal damage to silicone leads, regardless of the power output and duration of power delivery. However, mechanical insulation damage was observed to all silicone leads when at least 20 W was applied in a direction perpendicular to the lead. CONCLUSIONS: Polyurethane (PU55D) and copolymer materials have low thermal stability and are highly susceptible to thermal damage during cautery. Implanting physicians should be aware of the lead insulation materials being used during implant procedures and their properties. The use of direct contact cautery on transvenous leads should be minimized to avoid damage to the lead, especially on leads with polyurethane or copolymer outer insulations.


Assuntos
Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Eletrocoagulação/efeitos adversos , Temperatura Alta , Poliuretanos/química , Elastômeros de Silicone/química , Desenho de Equipamento , Falha de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Propriedades de Superfície
8.
Curr Cardiol Rep ; 11(5): 352-9, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19709495

RESUMO

Cardiac resynchronization therapy (CRT) has demonstrated improved quality of life, New York Heart Association class, left ventricular ejection fraction, and survival in patients with moderate to severe heart failure, left ventricular ejection fraction less than or equal to 35%, and a prolonged QRS duration. QRS duration remains the primary surrogate for mechanical dyssynchrony, defining the pathophysiology of abnormal regional mechanical activation. Studies have demonstrated that 30% to 40% of patients who meet current criteria for CRT are nonresponders. Therefore, there is great interest in the relationship between electrical and mechanical dyssynchrony, and the ability of each alone or together to predict response remains unknown. Echocardiographic approaches have emerged to quantify mechanical dyssynchrony with greater specificity than QRS duration alone. Although these methods are complex, exciting, and highly accurate for predicting response to CRT in single-center studies, they lack widespread applicability and validation to replace current criteria for device implantation. Use of echocardiography to define dyssynchrony and the impact of promising imaging methods for future patient selection for CRT are discussed.


Assuntos
Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Qualidade de Vida , Segurança , Ultrassonografia Doppler , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/patologia , Humanos , Prognóstico , Volume Sistólico , Função Ventricular Esquerda
9.
Heart Rhythm ; 16(5): 743-753, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30476543

RESUMO

BACKGROUND: Predicting a favorable cardiac resynchronization therapy (CRT) response holds great clinical importance. OBJECTIVE: The purpose of this study was to examine proteins from broad biological pathways and develop a prediction tool for response to CRT. METHODS: Plasma was collected from patients before CRT (SMART-AV [SmartDelay Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy] trial). A CRT response was prespecified as a ≥15-mL reduction in left ventricular end-systolic volume at 6 months, which resulted in a binary CRT response (responders 52%, nonresponders 48%; n = 758). RESULTS: Candidate proteins (n = 74) were evaluated from the inflammatory, signaling, and structural domains, which yielded 12 candidate biomarkers, but only a subset of these demonstrated predictive value for CRT response: soluble suppressor of tumorgenicity-2, soluble tumor necrosis factor receptor-II, matrix metalloproteinase-2, and C-reactive protein. These biomarkers were used in a composite categorical scoring algorithm (Biomarker CRT Score), which identified patients with a high/low probability of a response to CRT (P <.001) when adjusted for a number of clinical covariates. For example, a Biomarker CRT Score of 0 yielded 5 times higher odds of a response to CRT compared to a Biomarker CRT Score of 4 (P <.001). The Biomarker CRT Score demonstrated additive predictive value when considered against a composite of clinical variables. CONCLUSION: These unique findings demonstrate that developing a biomarker panel for predicting individual response to CRT is feasible and holds potential for point-of-care testing and integration into evaluation algorithms for patients presenting for CRT.


Assuntos
Proteína C-Reativa/análise , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Metaloproteinase 2 da Matriz/análise , Receptores Tipo II do Fator de Necrose Tumoral/análise , Idoso , Biomarcadores/sangue , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde/métodos , Período Pós-Operatório , Valor Preditivo dos Testes , Prognóstico
10.
Curr Opin Cardiol ; 23(5): 447-51, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18670255

RESUMO

PURPOSE OF REVIEW: Cardiac resynchronization therapy has been shown to improve survival, quality of life, exercise capacity, left ventricular ejection fraction and New York Heart Association functional class in patients with a prolonged QRS and moderate-to-severe heart failure resistant to optimal medical treatment. This patient population has an approximately 30-40% nonresponder rate to cardiac resynchronization therapy. It has been proposed that the use of echocardiographic imaging could be a more specific marker of intraventricular conduction delay rather than the surrogate marker of electrical delay demonstrated by prolonged QRS duration. RECENT FINDINGS: Recent clinical trials have evaluated not only how well imaging predicts dyssynchrony (Predictors of Response to Cardiac Resynchronization Therapy--PROSPECT) but also clinical outcomes in patients with dyssynchrony and narrow QRS duration (resynchronization therapy in narrow QRS--RETHINQ, evaluation of CRT in narrow QRS patients with mechanical dyssynchrony from a multicenter study--ESTEEM-CRT). The former trial failed to demonstrate a single reliable parameter for predicting dyssynchrony, whereas the latter trials did not demonstrate a clinical benefit from cardiac resynchronization therapy in patients with narrow QRS and evidence of dyssynchrony. SUMMARY: Results of recent clinical trials have challenged the applicability of contemporary echocardiographic techniques in evaluating dyssynchrony to clinical practice at the present time. Currently the optimal lead position is a lateral or posterolateral position with reasonable capture threshold and lack of diaphragm stimulation. With the refining of echocardiographic techniques and technology, perhaps areas of greatest delay may be targeted and used for guiding lead placement.


Assuntos
Eletrofisiologia Cardíaca/tendências , Estimulação Cardíaca Artificial , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Prognóstico , Resultado do Tratamento
12.
J Interv Card Electrophysiol ; 19(3): 149-55, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17899346

RESUMO

BACKGROUND: Numerous trials have demonstrated the effectiveness of cardiac resynchronization therapy (CRT) as an adjunct to medical therapy for the relief of heart failure (HF) symptoms in patients with a wide QRS duration (QRSd). Current guidelines recommend CRT in patients with an EF <35%, medically refractory NYHA Class III-IV HF and QRSd >or=120 ms. Previous studies have demonstrated QRSd as a marker of electrical dyssynchrony fails to predict response to CRT. In addition, studies have demonstrated significant differences in QRSd post CRT between responders and non-responders. Moreover, smaller non-controlled studies demonstrated that HF patients with a narrow QRSd may benefit from CRT. A growing body of evidence suggests that echocardiographic criteria may be a better method to evaluate mechanical dyssynchrony (MD) which may predict those that will benefit from CRT, particularly those with a narrow QRSd. The Resynchronization Therapy In Narrow QRS (RethinQ) study will evaluate mechanical dyssynchrony using echocardiography (both M mode and TDI) as an eligibility requirement for CRT. METHODS: The RethinQ study is a prospective, multi-center, randomized, double blind controlled clinical study. The objective of the RethinQ study is to evaluate the effectiveness of CRT in patients with approved ICD indication, advanced HF (NYHA Classification III), narrow QRSd (<130 ms) and evidence of MD measured by echocardiography. CONCLUSION: We hypothesize that patients with narrow QRS <130 ms, advanced HF, and MD as measured by echocardiography will benefit from CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Ecocardiografia/métodos , Ecocardiografia Doppler/métodos , Cardioversão Elétrica , Eletrofisiologia , Desenho de Equipamento , Sistema de Condução Cardíaco , Humanos , Marca-Passo Artificial , Projetos de Pesquisa , Remodelação Ventricular
13.
Am J Cardiol ; 119(2): 280-283, 2017 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-28126150

RESUMO

QTc prolongation has a high prevalence of and is associated with increased all-cause mortality. Nonetheless, QTc prolonging medications are often used during patient hospitalizations despite baseline prolongation and QTc changes. Data regarding the real-world relative risk of QTc prolongation in the hospital setting are lacking. In this study, we sought to quantify the degree and relative risk of QTc prolongation in patients receiving Arizona Center for Education and Research on Therapeutics (AzCERT) "known risk" medications. Electronic medical records of patients receiving an electrocardiogram at the University of Chicago, admitted in 2011 were analyzed. The longest QTc interval and medications administered within the preceding 24 hours were evaluated. Medications were classified into 4 categories according to the AzCERT classification. Of a total of 14,804 patients, mean QTc intervals were 485 versus 454 ms for men and 469 versus 453 ms for women receiving known risk medications compared with those receiving no risk medications (p <0.001). The rate of QTc prolongation was 71% versus 48% for men and 50% versus 34% for women, respectively. There was no significant increase in QTc prolongation for patients administered multiple QT-relevant medications or for those administered only conditional or possible risk medications. In conclusion, the prevalence of significant QTc prolongation in patients receiving AzCERT known risk medications is high. This may be a reflection of inadequate awareness or overall quality inadequacies.


Assuntos
Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/epidemiologia , Adulto , Idoso , Eletrocardiografia , Feminino , Hospitalização , Humanos , Síndrome do QT Longo/diagnóstico , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Medição de Risco , Fatores Sexuais
14.
Heart Rhythm ; 3(8): 881-6, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16876733

RESUMO

BACKGROUND: Inflammation and oxidative stress have been implicated in the pathogenesis of atrial fibrillation (AF). Lipid-lowering drugs, particularly statins and fibrates, possess anti-inflammatory and antioxidant properties. OBJECTIVES: The purpose of this study was to assess the impact of lipid-lowering drug use on AF prevalence in patients with reduced left ventricular ejection fraction (LVEF). METHODS: Data were obtained from ADVANCENT(SM), a multicenter registry of patients with reduced LVEF (

Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Hiperlipidemias/tratamento farmacológico , Hipolipemiantes/uso terapêutico , Disfunção Ventricular Esquerda/complicações , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Análise de Variância , Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Fatores de Confusão Epidemiológicos , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Estresse Oxidativo/efeitos dos fármacos , Prevalência , Sistema de Registros , Volume Sistólico/efeitos dos fármacos , Resultado do Tratamento , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/fisiopatologia
15.
Heart ; 102(21): 1742-1749, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27411837

RESUMO

OBJECTIVE: To evaluate the cost-effectiveness of implantable cardioverter defibrillators (ICDs), cardiac resynchronisation therapy pacemakers (CRT-Ps) and combination therapy (CRT-D) in patients with heart failure with reduced ejection fraction based on a range of clinical characteristics. METHODS: Individual patient data from 13 randomised trials were used to inform a decision analytical model. A series of regression equations were used to predict baseline all-cause mortality, hospitalisation rates and health-related quality of life and device-related treatment effects. Clinical variables used in these equations were age, QRS duration, New York Heart Association (NYHA) class, ischaemic aetiology and left bundle branch block (LBBB). A UK National Health Service perspective and a lifetime time horizon were used. Benefits were expressed as quality-adjusted life-years (QALYs). Results were reported for 24 subgroups based on LBBB status, QRS duration and NYHA class. RESULTS: At a threshold of £30 000 per QALY gained, CRT-D was cost-effective in 10 of the 24 subgroups including all LBBB morphology patients with NYHA I/II/III. ICD is cost-effective for all non-NYHA IV patients with QRS duration <120 ms and for NYHA I/II non-LBBB morphology patients with QRS duration between 120 ms and 149 ms. CRT-P was also cost-effective in all NYHA III/IV patients with QRS duration >120 ms. Device therapy is cost-effective in most patient groups with LBBB at a threshold of £20 000 per QALY gained. Results were robust to altering key model parameters. CONCLUSIONS: At a threshold of £30 000 per QALY gained, CRT-D is cost-effective in a far wider group than previously recommended in the UK. In some subgroups ICD and CRT-P remain the cost-effective choice.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca Sistólica/economia , Insuficiência Cardíaca Sistólica/terapia , Avaliação de Processos em Cuidados de Saúde/economia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Análise Custo-Benefício , Técnicas de Apoio para a Decisão , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Feminino , Insuficiência Cardíaca Sistólica/diagnóstico , Insuficiência Cardíaca Sistólica/mortalidade , Custos Hospitalares , Hospitalização/economia , Humanos , Masculino , Modelos Econômicos , Seleção de Pacientes , Anos de Vida Ajustados por Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento
16.
J Am Coll Cardiol ; 67(6): 674-683, 2016 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-26868693

RESUMO

BACKGROUND: Radiofrequency catheter ablation is used to treat recurrent ventricular tachycardia (VT). OBJECTIVES: This study evaluated long-term safety and effectiveness of radiofrequency catheter ablation using an open-irrigated catheter. METHODS: Patients with sustained monomorphic ventricular tachycardia associated with coronary disease were analyzed for cardiovascular-specific adverse events within 7 days of treatment, hospitalization duration, 6-month sustained monomorphic ventricular tachycardia recurrence, quality of life measured by the Hospital Anxiety and Depression Scale, long-term (1-, 2-, and 3-year) survival, symptomatic VT control, and amiodarone use. RESULTS: Overall, 249 patients, mean age 67.4 years, were enrolled. The cardiovascular-specific adverse events rate was 3.9% (9 of 233) with no strokes. Noninducibility of targeted VT was achieved in 75.9% of patients. Post-ablation median hospitalization was 2 days. At 6 months, 62.0% (114 of 184) of patients had no sustained monomorphic ventricular tachycardia recurrence; the proportion of patients with implantable cardioverter-defibrillator shocks decreased from 81.2% to 26.8% (p < 0.0001); the frequency of VT in implantable cardioverter-defibrillator patients with recurrences was reduced by ≥50% in 63.8% of patients; and the proportion with normal Hospital Anxiety and Depression Scale scores increased from 48.8% to 69.1% (p < 0.001). Patient-reported VT remained steady for 1, 2, and 3 years at 22.7%, 29.8%, and 24.1%, respectively. Amiodarone use and hospitalization decreased from 55% and 77.2% pre-ablation to 23.3% and 30.7%, 18.5% and 36.7%, 17.7% and 31.3% at 1, 2, and 3 years, respectively. CONCLUSIONS: Radiofrequency catheter ablation reduced implantable cardioverter-defibrillator shocks and VT episodes and improved quality of life at 6 months. A steady 3-year nonrecurrence rate with reduced amiodarone use and hospitalizations indicate improved long-term outcomes. (NaviStar ThermoCool Catheter for Endocardial RF Ablation in Patients With Ventricular Tachycardia [THERMOCOOL VT]; NCT00412607).


Assuntos
Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/instrumentação , Aprovação de Equipamentos , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Recidiva , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia , Irrigação Terapêutica/métodos , Fatores de Tempo , Resultado do Tratamento
17.
Circ Cardiovasc Imaging ; 9(1): e003738, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26763280

RESUMO

BACKGROUND: Cardiac sarcoidosis is associated with an increased risk of heart failure and sudden death, but its risk in patients with preserved left ventricular ejection fraction is unknown. Using cardiovascular magnetic resonance in patients with extracardiac sarcoidosis and preserved left ventricular ejection fraction, we sought to (1) determine the prevalence of cardiac sarcoidosis or associated myocardial damage, defined by the presence of late gadolinium enhancement (LGE), (2) quantify their risk of death/ventricular tachycardia (VT), and (3) identify imaging-based covariates that predict who is at greatest risk of death/VT. METHODS AND RESULTS: Parameters of left and right ventricular function and LGE burden were measured in 205 patients with left ventricular ejection fraction >50% and extracardiac sarcoidosis who underwent cardiovascular magnetic resonance for LGE evaluation. The association between covariates and death/VT in the entire group and within the LGE+ group was determined using Cox proportional hazard models and time-dependent receiver-operator curves analysis. Forty-one of 205 patients (20%) had LGE; 12 of 205 (6%) died or had VT during follow-up; of these, 10 (83%) were in the LGE+ group. In the LGE+ group (1) the rate of death/VT per year was >20× higher than LGE- (4.9 versus 0.2%, P<0.01); (2) death/VT were associated with a greater burden of LGE (14±11 versus 5±5%, P<0.01) and right ventricular dysfunction (right ventricular EF 45±12 versus 53±28%, P=0.04). LGE burden was the best predictor of death/VT (area under the receiver-operating characteristics curve, 0.80); for every 1% increase of LGE burden, the hazard of death/VT increased by 8%. CONCLUSIONS: Sarcoidosis patients with LGE are at significant risk for death/VT, even with preserved left ventricular ejection fraction. Increased LGE burden and right ventricular dysfunction can identify LGE+ patients at highest risk of death/VT.


Assuntos
Cardiomiopatias/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Sarcoidose/fisiopatologia , Função Ventricular Esquerda/fisiologia , Biópsia , Meios de Contraste , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Volume Sistólico/fisiologia
18.
J Interv Card Electrophysiol ; 43(2): 145-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25921348

RESUMO

PURPOSE: Heart failure (HF) is a major cause of morbidity and mortality, and ventricular dyssynchrony is an important contributor. The ReThinQ trial reported no improvement with cardiac resynchronization therapy (CRT) in HF patients with left ventricular ejection fraction (LVEF) <35%, narrow QRS (<130 ms), New York Heart Association (NYHA) class III, and echocardiographically detected dyssynchrony, in spite of echocardiographic optimization. We investigated whether a subset of narrow QRS patients might derive benefit from CRT, based on baseline PR interval. METHODS: We retrospectivelyanalyzed the 87 patients from ReThinQ who were randomized to CRT. Patients were divided into two groups: baseline PR interval <180 ms and baseline PR interval ≥180 ms. The primary outcome was change in VO2 max at 6 months; secondary outcomes were change in LVEF, 6-min walk distance, and change in NYHA class. RESULTS: Forty-six patients had PR < 180 ms and 41 had PR ≥ 180 ms. The baseline characteristics were similar in the two groups. As compared to patients with a short PR interval, at 6 months, only patients with PR ≥ 180 ms showed a statistically significant increase in VO2 max from 12.2 to 13.6 mL/kg min (P = 0.045). Similarly, LVEF was significantly improved only in the long PR group (0.26 to 0.28, P = 0.038). A greater percentage of patients in the long PR group showed improvement by at least one NYHA class (59 vs. 35%, P = 0.033). CONCLUSIONS: A longer baseline PR interval may allow more efficacious delivery of CRT by allowing programming of physiologic AV delays. A short baseline PR interval may contribute to LV under-filling and CRT non-response.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Ecocardiografia , Teste de Esforço , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
19.
Am J Cardiol ; 113(9): 1556-60, 2014 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-24731652

RESUMO

Cardiovascular magnetic resonance (CMR) imaging is being increasingly used to help identify patients with cardiac sarcoidosis (CS). Whereas ventricular arrhythmias have been well studied in this population, atrial arrhythmias have not been thoroughly investigated. We sought to better characterize the arrhythmia burden of a cohort of patients diagnosed with CS by CMR imaging. Patients with biopsy-proven extracardiac sarcoidosis were referred to the University of Chicago for evaluation of the presence of CS. CMR imaging was used to categorize the patients into 2 groups; those with and those without late gadolinium enhancement (LGE) for comparison of arrhythmic events. Arrhythmic evaluation included Holter monitor, event recorder, electrophysiology testing, or implantable cardioverter-defibrillator (ICD) interrogation; 192 consecutive patients were evaluated with CMR imaging, 57 of whom did not have ambulatory monitoring results and thus were excluded. LGE was present in 44 patients. Atrial arrhythmias were documented in 16 patients (36%) with myocardial LGE and in 11 patients (12%) without myocardial LGE (p = 0.002). Ventricular arrhythmias were documented in 27% of patients with myocardial LGE and 2.2% of LGE-negative patients (p = 0.00076). Of 26 LGE-positive patients with ICDs, 8 (30.8%) received therapies, 3 (11.5%) of which were inappropriate for atrial arrhythmias. In conclusion, atrial arrhythmias were documented more frequently than ventricular arrhythmias in patients with sarcoidosis with cardiac involvement and were 3 times more prevalent than in patients with sarcoidosis without cardiac involvement. Risk-benefit assessment of anticoagulation for primary prevention of stroke should be performed for patients with CS. In patients receiving implantable defibrillators, programming to minimize inappropriate ICD shocks for atrial arrhythmias must be considered.


Assuntos
Arritmias Cardíacas/complicações , Cardiomiopatias/diagnóstico , Gadolínio , Imageamento por Ressonância Magnética/métodos , Sarcoidose/diagnóstico , Adulto , Anticoagulantes/uso terapêutico , Arritmias Cardíacas/fisiopatologia , Cardiomiopatias/complicações , Cardiomiopatias/tratamento farmacológico , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Sarcoidose/complicações , Sarcoidose/tratamento farmacológico , Acidente Vascular Cerebral/prevenção & controle
20.
J Interv Card Electrophysiol ; 38(3): 209-15, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24113852

RESUMO

INTRODUCTION: The effect of defibrillation threshold (DFT) testing with induction of ventricular fibrillation (VF) on renal function is currently unknown. This study examined the acute effect of DFT testing on renal function in patients undergoing implantable cardioverter defibrillator (ICD) implantation. METHODS AND RESULTS: We performed a prospective cohort study of 148 consecutive patients who underwent ICD implantation from January 1, 2007 to May 30, 2008. Patients were assigned to one of two cohorts: a DFT group who underwent DFT testing at device implantation and a no-DFT group that was not tested. Baseline and 24-h postprocedure renal function were assessed with measurements of serum creatinine and estimated glomerular filtration rate (GFR) by the Modified Diet in Renal Disease equation. Changes in serum creatinine and estimated GFR were compared between cohorts. Ninety-eight patients (66%) underwent DFT testing (average VF induction count, 1.5 ± 0.9; mean VF duration, 10 ± 4 s). Fifty patients (34%) were not tested. Patients in the no-DFT group had lower mean left ventricular ejection fraction, higher New York Heart Association class, higher atrial fibrillation incidence, and greater intravenous contrast utilization at device implant. Baseline and postprocedure serum creatinine values were similar between groups (baseline, 1.25 ± 0.45 mg/dL; post-ICD, 1.26 ± 0.5 mg/dL). Baseline GFR was lower in the DFT cohort (55.2 ± 18.8 mL/min/BSA vs 63.7 ± 22.7 mL/min/BSA, p = 0.023). No significant differences between groups were observed in the mean change in serum creatinine or estimated GFR. CONCLUSIONS: DFT testing at the time of ICD implantation is not associated with acute adverse effects on renal function.


Assuntos
Injúria Renal Aguda/epidemiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Análise de Falha de Equipamento/estatística & dados numéricos , Testes de Função Renal/estatística & dados numéricos , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/prevenção & controle , Injúria Renal Aguda/diagnóstico , Causalidade , Chicago/epidemiologia , Comorbidade , Desfibriladores Implantáveis/efeitos adversos , Limiar Diferencial , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA