Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 253
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(16): 1466-1476, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37634188

RESUMO

BACKGROUND: Data regarding clinical outcomes after optical coherence tomography (OCT)-guided percutaneous coronary intervention (PCI) as compared with angiography-guided PCI are limited. METHODS: In this prospective, randomized, single-blind trial, we randomly assigned patients with medication-treated diabetes or complex coronary-artery lesions to undergo OCT-guided PCI or angiography-guided PCI. A final blinded OCT procedure was performed in patients in the angiography group. The two primary efficacy end points were the minimum stent area after PCI as assessed with OCT and target-vessel failure at 2 years, defined as a composite of death from cardiac causes, target-vessel myocardial infarction, or ischemia-driven target-vessel revascularization. Safety was also assessed. RESULTS: The trial was conducted at 80 sites in 18 countries. A total of 2487 patients underwent randomization: 1233 patients were assigned to undergo OCT-guided PCI, and 1254 to undergo angiography-guided PCI. The minimum stent area after PCI was 5.72±2.04 mm2 in the OCT group and 5.36±1.87 mm2 in the angiography group (mean difference, 0.36 mm2; 95% confidence interval [CI], 0.21 to 0.51; P<0.001). Target-vessel failure within 2 years occurred in 88 patients in the OCT group and in 99 patients in the angiography group (Kaplan-Meier estimates, 7.4% and 8.2%, respectively; hazard ratio, 0.90; 95% CI, 0.67 to 1.19; P = 0.45). OCT-related adverse events occurred in 1 patient in the OCT group and in 2 patients in the angiography group. Stent thrombosis within 2 years occurred in 6 patients (0.5%) in the OCT group and in 17 patients (1.4%) in the angiography group. CONCLUSIONS: Among patients undergoing PCI, OCT guidance resulted in a larger minimum stent area than angiography guidance, but there was no apparent between-group difference in the percentage of patients with target-vessel failure at 2 years. (Funded by Abbott; ILUMIEN IV: OPTIMAL PCI ClinicalTrials.gov number, NCT03507777.).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Humanos , Angiografia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Método Simples-Cego , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Diabetes Mellitus , Implante de Prótese Vascular/métodos , Stents
2.
Catheter Cardiovasc Interv ; 100 Suppl 1: S7-S13, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36661367

RESUMO

Although extensive clinical data support the utility of intravascular imaging to guide and optimize outcomes following percutaneous coronary interventions (PCI), clinical adoption remains limited. One of the primary reasons for limited utilization may be a lack of standardization on how to best integrate the data provided by intravascular imaging practically. Optical coherence tomography (OCT) offers a high-resolution intravascular imaging modality with integrated software automation that allows for incorporation of OCT into the routine workflow of PCIs. We suggest use of an algorithm called MLD MAX to incorporate OCT for imaging-guided interventions: the baseline OCT imaging run is intended to facilitate procedural planning and strategizing, consisting of assessment for predominant lesion morphology (M), measurement for stent length (L) and determination of stent diameter (D); the post-PCI OCT imaging run is designated for assessment of need for further optimization of stent result, and consists of analysis for medial dissections (M), adequate stent apposition (A) and stent expansion (X). Incorporation of the MLD MAX algorithm into daily practice guides an efficient and easily-memorable workflow for optimized PCI procedures.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Tomografia de Coerência Óptica/métodos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Angiografia Coronária/métodos , Fluxo de Trabalho , Resultado do Tratamento , Stents , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Ultrassonografia de Intervenção/métodos
3.
Catheter Cardiovasc Interv ; 100 Suppl 1: S25-S35, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36661369

RESUMO

BACKGROUND: Uncovered struts are a determinant of stent failure. The impact of plaque composition and procedural factors on the occurrence, evolution, and outcomes of uncovered struts in a high-risk setting has not been investigated. OBJECTIVE: To investigate the determinants and long-term clinical impact of largely uncovered struts (LUS) in thin-struts drug-eluting stents (DES) implanted in complex lesions by intracoronary optical coherence tomography (OCT). METHODS: Ninety patients with multivessel disease undergoing staged complete revascularization were randomly assigned to bioabsorbable or durable polymer DES. OCT were serially performed during the index procedure, at 3- and 18-month follow-up, and analyzed by an independent core lab. Struts were defined uncovered by OCT if no tissue was visible above the struts. LUS were defined as ≥30% of uncovered struts at 3-month follow-up. Clinical outcomes were the occurrence of target vessel failure (TVF) and major adverse cardiac and cerebrovascular events (MACCE) at 5-year follow-up. RESULTS: LUS occurred in 31 patients (34.4%) regardless of stent platform. At 5 years, no differences were observed in the rate of TVF (12.7% vs. 13.4%; p = 0.91) and MACCE (23.9% vs. 24.9%; p = 0.88) between the two groups. At multivariate logistic regression, plaque rupture, mean lumen diameter, proximal reference vessel area, and maximum stent deployment pressure were independent predictors of LUS. CONCLUSIONS: LUS are a frequent finding in complex coronary lesions treated with thin-struts DES, especially in the presence of plaque rupture. However, in this study, no significant safety signal related to LUS emerged in long-term follow-up.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Placa Aterosclerótica , Humanos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Desenho de Prótese , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos
4.
Circulation ; 142(22): 2095-2106, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33032450

RESUMO

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used to treat cardiogenic shock. However, VA-ECMO might hamper myocardial recovery. The Impella unloads the left ventricle. This study aimed to evaluate whether left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO was associated with lower mortality. METHODS: Data from 686 consecutive patients with cardiogenic shock treated with VA-ECMO with or without left ventricular unloading using an Impella at 16 tertiary care centers in 4 countries were collected. The association between left ventricular unloading and 30-day mortality was assessed by Cox regression models in a 1:1 propensity score-matched cohort. RESULTS: Left ventricular unloading was used in 337 of the 686 patients (49%). After matching, 255 patients with left ventricular unloading were compared with 255 patients without left ventricular unloading. In the matched cohort, left ventricular unloading was associated with lower 30-day mortality (hazard ratio, 0.79 [95% CI, 0.63-0.98]; P=0.03) without differences in various subgroups. Complications occurred more frequently in patients with left ventricular unloading: severe bleeding in 98 (38.4%) versus 45 (17.9%), access site-related ischemia in 55 (21.6%) versus 31 (12.3%), abdominal compartment in 23 (9.4%) versus 9 (3.7%), and renal replacement therapy in 148 (58.5%) versus 99 (39.1%). CONCLUSIONS: In this international, multicenter cohort study, left ventricular unloading was associated with lower mortality in patients with cardiogenic shock treated with VA-ECMO, despite higher complication rates. These findings support use of left ventricular unloading in patients with cardiogenic shock treated with VA-ECMO and call for further validation, ideally in a randomized, controlled trial.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Internacionalidade , Choque Cardiogênico/mortalidade , Choque Cardiogênico/terapia , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Choque Cardiogênico/diagnóstico , Resultado do Tratamento
5.
J Biomech Eng ; 142(5)2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31654052

RESUMO

In this work, a heavily calcified coronary artery model was reconstructed from optical coherence tomography (OCT) images to investigate the impact of calcification characteristics on stenting outcomes. The calcification was quantified at various cross sections in terms of angle, maximum thickness, and area. The stent deployment procedure, including the crimping, expansion, and recoil, was implemented. The influence of calcification characteristics on stent expansion, malapposition, and lesion mechanics was characterized. Results have shown that the minimal lumen area following stenting occurred at the cross section with the greatest calcification angle. The calcification angle constricted the stretchability of the lesion and thus resulted in a small lumen area. The maximum principal strain and von Mises stress distribution patterns in both the fibrotic tissue and artery were consistent with the calcification profiles. The radially projected region of the calcification tends to have less strain and stress. The peak strain and stress of the fibrotic tissue occurred near the interface with the calcification. It is also the region with a high risk of tissue dissection and strut malapposition. In addition, the superficial calcification with a large angle aggregated the malapposition at the middle of the calcification arc. These detailed mechanistic quantifications could be used to provide a fundamental understanding of the role of calcification in stent expansions, as well as to exploit their potential for enhanced pre- and post-stenting strategies.


Assuntos
Stents , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária , Vasos Coronários , Humanos , Pessoa de Meia-Idade
6.
Catheter Cardiovasc Interv ; 93(3): 545-552, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30312990

RESUMO

OBJECTIVES: This study reports on the clinical effects of complete vs incompletely revascularized coronary artery disease on transcatheter aortic valve replacement (TAVR). BACKGROUND: There is a high prevalence of active coronary artery disease (CAD) in patients undergoing TAVR but preemptive revascularization remains controversial. METHODS: Patients were categorized into three cohorts: complete revascularization (CR), incomplete revascularization of a major epicardial artery (IR Major), and incomplete revascularization of a minor epicardial artery only (IR Minor). When feasible, SYNTAX scoring was performed for exploratory analysis. Analyses were performed using Cox proportional hazard models and Kaplan-Meier method. RESULTS: A total of 323 patients with active CAD were included. Adjusted outcomes showed that patients with IR Major had increased incidence of acute myocardial infarction (AMI) or revascularization compared with those in the CR cohort (HR 3.72, P = 0.048). No difference was noted in all-cause mortality or all-cause readmission rates. Exploratory secondary analysis with residual SYNTAX scores showed a significant interaction between disease burden and AMI/revascularization, as well as all-cause readmission. All-cause mortality remained unaffected based on residual SYNTAX scores. CONCLUSIONS: This is a retrospective single-center study reporting on pre-TAVR revascularization outcomes in patients with active CAD. In this analysis, we found that patients undergoing TAVR benefited from achieving complete revascularization to abate future incidence of AMI/revascularization. Despite this finding, all-cause mortality remained unaffected. Future efforts should focus on the role of functional assessment of the coronaries, as well as the long-term effects of complete revascularization in a larger patient cohort.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Periférico , Doença da Artéria Coronariana/terapia , Artéria Femoral , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Causas de Morte , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
7.
J Biomech Eng ; 141(2)2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30453326

RESUMO

Severely calcified plaque is of great concern when planning and implementing a stenting intervention. In this work, computational models were developed to investigate the influence of calcium characteristics on stenting outcomes. The commonly used clinical measurements of calcium (i.e., the arc angle, maximum thickness, length, and volume) were varied to estimate stenting outcomes in terms of lumen gain, stent underexpansion, strut malapposition, and stress or strain distributions of the stenotic lesion. Results have shown that stenting outcomes were most sensitive to the arc angle of the calcium. A thick calcium with a large arc angle resulted in poor stenting outcomes, such as severe stent underexpansion, D-shaped lumen, increased strut malapposition, and large stresses or strains in the plaque. This was attributed to the circumferential stretch of the tissue. Specifically, the noncalcium component was stretched significantly more than the calcium. The circumferential stretch ratios of calcium and noncalcium component were approximately 1.44 and 2.35, respectively, regardless of calcium characteristics. In addition, the peak stress or strain within the artery and noncalcium component of the plaque occurred at the area adjacent to calcium edges (i.e., the interface between the calcium and the noncalcium component) coincident with the location of peak malapposition. It is worth noting that calcium played a protective role for the artery underneath, which was at the expense of the overstretch and stress concentrations in the other portion of the artery. These detailed mechanistic quantifications could be used to provide a fundamental understanding of the impact of calcium quantifications on stent expansions, as well as to exploit their potential for a better preclinical strategy.

8.
Eur Heart J ; 39(26): 2460-2468, 2018 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-29931092

RESUMO

Aims: Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (HARMONEE) (NCT02073565) was a randomized pivotal registration trial of the Combo stent, which combined sirolimus and an abluminal bioabsorbable polymer with a novel endoluminal anti-CD34+ antibody coating designed to capture endothelial progenitor cells (EPC) and promote percutaneous coronary intervention (PCI) site healing. Methods and results: Clinically stabilized PCI subjects were randomized 1:1 to receive Combo or everolimus-eluting stents (EES). Between February 2014 and June 2016, 572 subjects with 675 coronary lesions underwent 1-year angiography and fractional flow reserve, with optical coherence tomography (OCT) in the first 140 patients. The primary clinical endpoint was non-inferior 1-year target vessel failure (TVF). The primary mechanistic endpoint of EPC capture activity was superior strut coverage by OCT. Target vessel failure occurred in 7.0% Combo (20/287) vs. 4.2% EES (12/285), a 2.8% [95% confidence interval (95% CI) -1.0%, 6.5%] difference, meeting the non-inferiority hypothesis (P = 0.02). There were no cardiac deaths, with one stent thrombosis observed in the EES group. Quantitative coronary angiography late loss with Combo was equivalent to EES. Optical coherence tomography strut coverage at 1 year was superior with Combo vs. EES [91.3% (95% CI 88.7%, 93.8%) vs. 74.8% (95% CI 70.0%, 79.6%), P < 0.001], with homogeneous tissue in 81.2% vs. 68.8%, respectively. Conclusion: Combo stent demonstrated non-inferior 1-year TVF and late loss in a randomized comparison to EES, with superior strut-based tissue coverage by OCT as a surrogate of EPC capture technology activity.


Assuntos
Síndrome Coronariana Aguda/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Células Progenitoras Endoteliais/citologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Idoso , Anticorpos/uso terapêutico , Antígenos CD34/metabolismo , Angiografia Coronária , Células Progenitoras Endoteliais/metabolismo , Estudos de Equivalência como Asunto , Everolimo/administração & dosagem , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Imunossupressores/administração & dosagem , Japão , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea/métodos , Recidiva , Método Simples-Cego , Tomografia de Coerência Óptica , Estados Unidos
9.
Catheter Cardiovasc Interv ; 91(2): 345-353, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28836345

RESUMO

OBJECTIVE: Determine the feasibility and predictors of early discharge after minimalist transcatheter aortic valve replacement (TAVR). BACKGROUND: Duration of hospitalization has a direct impact on overall cost of care, but the clinical impact of length of stay (LOS) in patients undergoing minimalist TAVR remains unclear. METHODS: We studied 268 patients who underwent minimalist TAVR. Short LOS (sLOS) was defined as post-procedural LOS ≤ 3 days and observed in 163 patients. Prolonged LOS (pLOS) was observed in 105 patients. Propensity score matching based on 39 variables yielded 54 pairs of patients in each group. We analyzed 30-day mortality, 30-day re-hospitalization and long-term survival data. Multivariate regression models were used to define predictors of sLOS. RESULTS: Thirty-day mortality was 0% versus 5.5% in the sLOS and pLOS groups, respectively (P = 0.08). Incidence of re-hospitalization was higher in pLOS (13% vs. 3.7%). sLOS was associated with lower odds ratio of minor vascular complication (OR 0.1 [95% CI: 0.01, 0.75], P = 0.05), any bleeding (OR 0.35 [95% CI: 0.14, 0.87], P = 0.02), blood transfusion (OR 0.27 [95% CI: 0.08, 0.81], P = 0.02), and new pacemaker implantation (OR 0.23 [95% CI: 0.1, 0.53], P < 0.001). Discharge to home had a significantly higher odd ratio for sLOS (OR 8.67 [95% CI: 3.59, 23.11], P < 0.001). CONCLUSION: In appropriately selected patients, sLOS following minimalist TAVR approach in an experienced and high volume center is feasible and safe. Implementing such a strategy may reduce medical costs with the potential clinical benefit of early re-habilitation for the elderly TAVR population.


Assuntos
Valva Aórtica/cirurgia , Tempo de Internação , Alta do Paciente , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Estudos de Viabilidade , Feminino , Humanos , Masculino , Readmissão do Paciente , Segurança do Paciente , Seleção de Pacientes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Circulation ; 133(16): 1548-59, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-26957531

RESUMO

BACKGROUND: We previously described a strong association between fibromuscular dysplasia (FMD) and spontaneous coronary artery dissection. Angiographic manifestations of coronary FMD aside from dissection were considered rare. However, we observed several coronary FMD angiographic abnormalities with corresponding optical coherence tomography abnormalities. METHODS AND RESULTS: Baseline demographics and imaging of patients with suspected coronary FMD at Vancouver General Hospital were reviewed. Presence of multifocal (string-of-beads) extracoronary FMD was confirmed by 2 specialists. In these patients, coronary angiographic findings (excluding dissected segments) were reviewed and classified by 2 experienced angiographers for irregular stenosis, that is, stenosis with irregular borders in a focal or diffuse pattern with/without systolic accentuation; smooth stenosis, diffuse or focal; segmental dilatation/ectasia; and tortuosity. Optical coherence tomography was performed in a subset of patients. Of 32 patients with extracoronary FMD and suspected coronary involvement, 28 were women (88%), and their mean age was 59.4±9.9 years. Nineteen presented with myocardial infarction (13 caused by spontaneous coronary artery dissection), and 13 had stable symptoms. The observed coronary angiographic abnormalities included tortuosity in all cases (91% were moderate to severe), irregular stenosis in 59%, smooth stenosis in 19%, and segmental dilatation/ectasia in 56%. Fifteen patients had optical coherence tomography of the abnormal segments showing abnormalities, including multiple areas of patchy or diffuse intimal, medial or adventitial abnormalities with thickening/accumulation of varied reflectivities, macrophage infiltration, loss/duplication of elastic membranes, and cavitation. CONCLUSIONS: This is the first case series describing findings suggestive of angiographic and intracoronary manifestations of coronary FMD. Future studies should prospectively review these features in patients with extracoronary FMD.


Assuntos
Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Displasia Fibromuscular/diagnóstico por imagem , Idoso , Angiografia Coronária/métodos , Feminino , Displasia Fibromuscular/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
J Card Fail ; 23(6): 455-463, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28435004

RESUMO

BACKGROUND: Percutaneous ventricular restoration therapy with the use of a left ventricle (LV)-partitioning Parachute device has emerged as a clinical treatment option for LV apical aneurysm after extensive anterior myocardial infarction (AMI). We assessed changes of diastolic mechanics and functional improvements following LV Parachute device implantation by means of cardiac computerized tomography (CCT). METHODS AND RESULTS: CCT data were obtained from 28 patients before and after LV Parachute device implantation. Diastolic functional indices were determined by means of quantitative CCT assessment: 1) transmitral velocities in early (E) and late (A) diastole and ratio (E/A); 2) early diastolic mitral septal tissue velocity (Ea) and E/Ea; and 3) vortex formation time (VFT). Functional improvements were assessed with the use of New York Heart Association (NYHA) functional classification. Among the study patients, there were no significant differences in all transmitral velocities and E/A, though there was significantly increased Ea, reduced E/Ea, and greater VFT 6 months after LV Parachute device implantation. Finally, the improvement of diastolic functional indices after Parachute treatment correlated with observed clinical functional alterations (Δ E/Ea and Δ NYHA functional class:, r = 0.563; P = .002; Δ VFT and Δ NYHA functional class: r = -0.507; P = .006). CONCLUSIONS: LV Parachute device implantation therapy in heart failure caused by AMI and LV apical aneurysm formation showed improvements in several diastolic functional mechanics according to CCT-based measures.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Coração Auxiliar/tendências , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/tendências , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/cirurgia
12.
Catheter Cardiovasc Interv ; 89(4): E104-E111, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27470983

RESUMO

BACKGROUND: The Parachute is a novel percutaneously implanted ventricular partitioning device (VPD) that has emerged as a safe and feasible treatment option for patients with heart failure following anterior wall myocardial infarction. VPD efficacy is likely dependent on optimal device placement, but to date there are no published data examining the effect of device positioning on patient outcomes. METHODS AND RESULTS: We retrospectively identified 32 patients successfully implanted with the Parachute device, all of whom underwent cardiac computed tomography (CCT) at baseline and after 6 months of follow-up. Patients were divided into two groups based on self-reported improvement in New York Heart Association (NYHA) functional class: "not improved NYHA" (n = 12) and "improved NYHA" (n = 20). There were significant differences between both groups with regard to device positioning on follow-up CCT. Compared to patients with "improved NYHA," patients with "not improved NYHA" had longer distances from device foot to left ventricular apex (8.0 ± 4.9 vs. 2.9 ± 4.6 mm; P = 0.01), and higher lateral angles (18.0 ± 14 vs. 9.1 ± 6.8 degrees; P = 0.02), respectively. There was no significant difference between the two groups in landing zone (45.4 ± 7. vs. 45.1 ± 6.9 mm; P = 0.92) and inferior angle (14.0 ± 11.9 vs. 14.3 ± 10.1 degrees; P = 0.95). There was a numerically larger malapposition area in the "not improved NYHA" group (5.1 ± 4.5 vs. 3.2 ± 2.2 cm2; P = 0.12). CONCLUSION: Quality of Parachute implant impacted clinical outcome, these findings should be applied prospectively in helping operators to achieve optimal implant. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Remodelação Ventricular/fisiologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
13.
Eur Heart J ; 37(15): 1220-7, 2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-26763790

RESUMO

AIMS: Coronary plaque characteristics are associated with ischaemia. Differences in plaque volumes and composition may explain the discordance between coronary stenosis severity and ischaemia. We evaluated the association between coronary stenosis severity, plaque characteristics, coronary computed tomography angiography (CTA)-derived fractional flow reserve (FFRCT), and lesion-specific ischaemia identified by FFR in a substudy of the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). METHODS AND RESULTS: Coronary CTA stenosis, plaque volumes, FFRCT, and FFR were assessed in 484 vessels from 254 patients. Stenosis >50% was considered obstructive. Plaque volumes (non-calcified plaque [NCP], low-density NCP [LD-NCP], and calcified plaque [CP]) were quantified using semi-automated software. Optimal thresholds of quantitative plaque variables were defined by area under the receiver-operating characteristics curve (AUC) analysis. Ischaemia was defined by FFR or FFRCT ≤0.80. Plaque volumes were inversely related to FFR irrespective of stenosis severity. Relative risk (95% confidence interval) for prediction of ischaemia for stenosis >50%, NCP ≥185 mm(3), LD-NCP ≥30 mm(3), CP ≥9 mm(3), and FFRCT ≤0.80 were 5.0 (3.0-8.3), 3.7 (2.4-5.6), 4.6 (2.9-7.4), 1.4 (1.0-2.0), and 13.6 (8.4-21.9), respectively. Low-density NCP predicted ischaemia independent of other plaque characteristics. Low-density NCP and FFRCT yielded diagnostic improvement over stenosis assessment with AUCs increasing from 0.71 by stenosis >50% to 0.79 and 0.90 when adding LD-NCP ≥30 mm(3) and LD-NCP ≥30 mm(3) + FFRCT ≤0.80, respectively. CONCLUSION: Stenosis severity, plaque characteristics, and FFRCT predict lesion-specific ischaemia. Plaque assessment and FFRCT provide improved discrimination of ischaemia compared with stenosis assessment alone.


Assuntos
Isquemia Miocárdica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Placa Aterosclerótica/fisiopatologia , Remodelação Ventricular/fisiologia
14.
J Card Fail ; 22(4): 316-20, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26724573

RESUMO

BACKGROUND: Diastolic dysfunction (DD), a precursor to clinical heart failure (HF), has traditionally been evaluated by means of echocardiography. Data regarding morphologic descriptions of pulmonary vein (PV) orifices in transition from DD to HF have been lacking. METHODS AND RESULTS: We retrospectively studied 124 subjects with computerized tomography (CT)-derived PV parameters and echocardiography-derived diastolic indices. We categorized our subjects as 1) non-DD, 2) DD, or 3) heart failure with preserved ejection fraction (HFpEF) and observed a graded enlargement for 4 PV orifice areas across these groups. Positive linear relationship between the 4 PV orifice areas, echocardiography-derived mean pulmonary capillary wedge pressure (PCWP), and velocity of propagation (VP) were observed. Finally, maximum areas of left superior pulmonary vein (LSPV) and left inferior pulmonary vein (LIPV) significantly increased clinical diagnosis of HFpEF (likelihood-ratio χ(2): from 42.92 to 50.75 and 54.67 for LSPV and LIPV, respectively) when superimposed on left ventricular mass index, PCWP, and left atrial volume. CONCLUSIONS: PV size measurements with the use of CT are feasible and further aid in diseases discrimination between preclinical DD and those progressed into HF, even with preserved global pumping. Our data suggest that CT-based PV measures may help to identify subjects at risk for HF.


Assuntos
Progressão da Doença , Insuficiência Cardíaca/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Estudos Transversais , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia
15.
Catheter Cardiovasc Interv ; 88(2): E45-51, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26526037

RESUMO

OBJECTIVES: The aim of current study is to assess the near term impact of percutaneous ventricular restoration therapy (PVR), Parachute(®) on mitral valve (MV) geometry by cardiac computed tomography (CCT). BACKGROUND: Recent data demonstrates the feasibility of PVR for treatment of post anterior myocardial infarction (MI) heart failure. Little is known, however, about the interaction of the device and left ventricular structures, particularly the MV apparatus. METHODS: This is a retrospective Core Laboratory analysis of Parachute Trials' CCT data. Patients with paired (before and after Parachute implant) CCT acquisitions were included into analysis. MV geometric parameters were measured. RESULTS: Thirty-three patients were included in the analysis. The mean time of follow-up CCT post procedure was 188 ± 52 days. There were significant reduction in tenting height (A1P1: -1.70 ± 1.89 mm, -17.40 ± 20.20%; A2P2: -1.43 ± 1.89 mm, -12.10 ± 15.00%; A3P3: -1.54 ± 1.58 mm, -15.50 ± 15.20%, P < 0.001), tenting volume (-0.93 ± 0.60 mm3, -22.00 ± 11.40%, P < 0.001), systolic interpapillary muscle distance (-2.22 ± 2.11 mm, -7.51 ± 7.23%, P < 0.001) and diastolic interpapillary muscle distance (-3.14 ± 2.20 mm, -8.46 ± 5.73%, P < 0.001) post PVR. CONCLUSIONS: In post anterior MI heart failure patients, PVR has favorable near term impact on MV geometry as assessed by CCT. © 2015 Wiley Periodicals, Inc.


Assuntos
Infarto Miocárdico de Parede Anterior/terapia , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Infarto Miocárdico de Parede Anterior/diagnóstico por imagem , Infarto Miocárdico de Parede Anterior/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ensaios Clínicos como Assunto , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
J Endovasc Ther ; 23(5): 723-30, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27385151

RESUMO

PURPOSE: To examine the hypothesis that alternative flush media could be used for lower extremity optical coherence tomography (OCT) imaging in long lesions that would normally require excessive use of contrast. METHODS: The OPTical Imaging Measurement of Intravascular Solution Efficacy (OPTIMISE) trial was a single-center, prospective study (ClinicalTrials.gov identifier NCT01743872) that enrolled 23 patients (mean age 68±11 years; 14 men) undergoing endovascular intervention involving the superficial femoral artery. Four flush media (heparinized saline, dextran, carbon dioxide, and contrast) were used in succession in random order for each image pullback. Quality was defined as ≥270° visualization of vessel wall layers from each axial image. Mean proportions (± standard deviation) of image quality for each flush medium were assessed using 1-way analysis of variance and are reported with the 95% confidence intervals (CI). RESULTS: Four OCT catheters failed, leaving 19 patients who completed the OCT imaging protocol; from this cohort, 51 highest quality runs were selected for analysis. Average vessel diameter was 3.99±1.01 mm. OCT imaging allowed 10- to 15-µm resolution of the lumen border, with diminishing quality as vessel diameter increased. Plaque characterization revealed fibrotic lesions. Mean proportions of image quality were dextran 87.2%±12% (95% CI 0.81 to 0.94), heparinized saline 74.3%±24.8% (95% CI 0.66 to 0.93), contrast 70.1%±30.5% (95% CI 0.52 to 0.88), and carbon dioxide 10.0%±10.4% (95% CI 0.00 to 0.26). Dextran, saline, and contrast provided better quality than carbon dioxide (p<0.001). CONCLUSION: OCT is feasible in peripheral vessels <5 mm in diameter. Dextran or saline flush media can allow lesion characterization, avoiding iodinated contrast. Carbon dioxide is inadequate for peripheral OCT imaging. Axial imaging may aid in enhancing durability of peripheral endovascular interventions.


Assuntos
Dióxido de Carbono/administração & dosagem , Meios de Contraste/administração & dosagem , Dextranos/administração & dosagem , Artéria Femoral/diagnóstico por imagem , Iohexol/administração & dosagem , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Cloreto de Sódio/administração & dosagem , Tomografia de Coerência Óptica/métodos , Idoso , Procedimentos Endovasculares , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Doença Arterial Periférica/terapia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Eur Heart J ; 36(47): 3346-55, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26242713

RESUMO

AIMS: ILUMIEN I is the largest prospective, non-randomized, observational study of percutaneous coronary intervention (PCI) procedural practice in patients undergoing intra-procedural pre- and post-PCI fractional flow reserve (FFR) and optical coherence tomography (OCT). We report on the impact of OCT on physician decision-making and the association with post-PCI FFR values and early clinical events. METHODS AND RESULTS: Optical coherence tomography and documentary FFR were performed pre- and post-PCI in 418 patients (with 467 stenoses) with stable or unstable angina or NSTEMI. Based on pre-PCI OCT, the procedure was altered in 55% of patients (57% of all stenoses) by selecting different stent lengths (shorter in 25%, longer in 43%). After clinically satisfactory stent implantation using angiographic guidance, post-PCI FFR and OCT were repeated. Optical coherence tomography abnormalities deemed unsatisfactory by the implanting physician were identified: 14.5% malapposition, 7.6% under-expansion, 2.7% edge dissection and prompted further stent optimization based on OCT in 25% of patients (27% of all stenoses) using additional in-stent post-dilatation (81%, 101/124) or placement of 20 new stents (12%). Optimization subgroups were identified post hoc: stent placement without reaction to OCT findings (n = 137), change in PCI planning by pre-PCI OCT (n = 165), post-PCI optimization based on post-PCI OCT (n = 41), change in PCI planning, and post-PCI optimization based on OCT (n = 65). Post-PCI FFR values were significantly different (P = 0.003) between optimization groups (lower in cases with pre- and post-PCI reaction to OCT) but no longer different after post-PCI stent optimization. MACE events at 30 days were low: death 0.25%, MI 7.7%, repeat PCI 1.7%, and stent thrombosis 0.25%. CONCLUSION: Physician decision-making was affected by OCT imaging prior to PCI in 57% and post-PCI in 27% of all cases. CLINICALTRIALS. GOV IDENTIFIER: NCT01663896, Observational Study of Optical Coherence Tomography (OCT) in Patients Undergoing Fractional Flow Reserve (FFR) and Percutaneous Coronary Intervention (ILUMIEN I).


Assuntos
Estenose Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Angina Pectoris/etiologia , Tomada de Decisão Clínica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica , Estudos Prospectivos , Stents , Tomografia de Coerência Óptica/métodos
18.
Catheter Cardiovasc Interv ; 85(4): E108-15, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25178981

RESUMO

BACKGROUND: While the current methodology for determining fibrous cap (FC) thickness of lipid plaques is based on manual measurements of arbitrary points, which could lead to high variability and decreased accuracy, it ignores the three-dimensional (3-D) morphology of coronary artery disease. OBJECTIVE: To compare, utilizing optical coherence tomography (OCT) assessments, volumetric quantification of FC, and macrophage detection using both visual assessment and automated image processing algorithms in non-culprit lesions of STEMI and stable angina pectoris (SAP) patients. METHODS: Lipid plaques were selected from 67 consecutive patients (1 artery/patient). FC was manually delineated by a computer-aided method and automatically classified into three thickness categories: FC < 65 µm (i.e., thin-cap fibroatheroma [TCFA]), 65-150 µm, and >150 µm. Minimum thickness, absolute categorical surface area, and fractional luminal area of FC were analyzed. Automated detection and quantification of macrophage was performed within the segmented FC. RESULTS: A total of 5,503 cross-sections were analyzed. STEMI patients when compared with SAP patients had more absolute categorical surface area for TCFA (0.43 ± 0.45 mm(2) vs. 0.15 ± 0.25 mm(2) ; P = 0.011), thinner minimum FC thickness (31.63 ± 17.09 µm vs. 47.27 ± 26.56 µm, P = 0.012), greater fractional luminal area for TCFA (1.65 ± 1.56% vs. 0.74 ± 1.2%, P = 0.046), and greater macrophage index (0.0217 ± 0.0081% vs. 0.0153 ± 0.0045%, respectively, P < 0.01). CONCLUSION: The novel OCT-based 3-D quantification of the FC and macrophage demonstrated thinner FC thickness and larger areas of TCFA coupled with more inflammation in non-culprit sites of STEMI compared with SAP.


Assuntos
Angina Estável/diagnóstico , Vasos Coronários/patologia , Inflamação/diagnóstico , Infarto do Miocárdio/diagnóstico , Tomografia de Coerência Óptica , Idoso , Algoritmos , Angina Estável/metabolismo , Angina Estável/patologia , Automação , Vasos Coronários/química , Feminino , Fibrose , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Inflamação/metabolismo , Inflamação/patologia , Lipídeos/análise , Macrófagos/patologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Placa Aterosclerótica , Valor Preditivo dos Testes , Estudos Retrospectivos
19.
Catheter Cardiovasc Interv ; 86(7): 1141-50, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-25044635

RESUMO

OBJECTIVES: We studied coronary vasomotion in patients treated with the Mistent(®) absorbable polymer sirolimus-eluting stent (APSES) and in patients implanted with the Endeavor(®) zotarolimus-eluting stent (ZES). BACKGROUND: First generation (1st-gen) drug-eluting stents (DES) induce persistent vasomotor dysfunction in the treated coronary artery. It is unknown whether and to what extent the implantation of an absorbable polymer DES impairs coronary vasomotion. METHODS: This sub-study of the DESSOLVE II trial included 19 APSES Mistent(®) and 10 ZES Endeavor(®) patients. Incremental atrial pacing and quantitative coronary angiography were used to assess vasomotion proximal and distal to the stent and in a reference segment at 9 months after implantation. Percent changes in vessel diameter with pacing versus baseline were calculated and compared. Vasomotor response of the APSES group was also compared with changes observed in a historical group of 17 patients implanted with a 1st-gen sirolimus-eluting stent (SES). RESULTS: Normal vasomotion (vasodilatation) was preserved and of comparable magnitude in the APSES and in the ZES group both proximally (P = 0.34) and distally (P = 0.38) to the stent. This finding was not observed in the 1st-gen SES group showing marked pacing-induced vasoconstriction at both stent edges (P < 0.05 vs. APSES). The results were practically unchanged after excluding patients with absolute changes in vessel diameter <3% between baseline and maximal pacing. CONCLUSIONS: The implantation of an absorbable polymer sirolimus-eluting stent is associated with preserved coronary vasomotion, comparable to that observed after implantation of the Endeavor(®) ZES, and distinct from 1st-gen SES which induce coronary vasomotor dysfunction.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Vasodilatação , Idoso , Estimulação Cardíaca Artificial , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Europa (Continente) , Feminino , Estudo Historicamente Controlado , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Método Simples-Cego , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Vasoconstrição
20.
Catheter Cardiovasc Interv ; 85(7): 1141-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25044710

RESUMO

BACKGROUND: Optical coherence tomography (OCT) is a new intracoronary imaging modality that has excellent resolution and image quality and has been used to image neointimal coverage after stent implantation. OCT has been compared to histologic, intravascular ultrasound, and scanning electron microscopy (SEM) studies. However, OCT has not been compared with SEM for imaging stent coverage over side branches. OBJECTIVE: The aim of this study was to compare OCT with SEM in imaging neointimal coverage over stent struts bridging coronary side-branch ostia. METHODS: Using a balloon-overstretch in-stent restenosis model, we deployed 38 everolimus-eluting stents across coronary bifurcations in nine pigs. We performed OCT immediately after stenting and 4 weeks later; SEM was performed after euthanizing the pigs. OCT images of each stent were compared to the corresponding SEM image. RESULTS: We analyzed OCT frames (n=111) for strut-level neointimal coverage and compared them to corresponding SEM images. The concordance correlation coefficient was 0.809 (95%CI; 0.734-0.864) and 0.951 (95%CI; 0.930-0.966) for covered and uncovered struts, respectively. CONCLUSIONS: In a non-atherosclerotic pig model, we showed strong agreement between OCT and SEM in imaging coverage of stent struts bridging side-branch ostia.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Reestenose Coronária/patologia , Vasos Coronários/patologia , Microscopia Eletrônica de Varredura , Stents , Tomografia de Coerência Óptica , Angioplastia Coronária com Balão/efeitos adversos , Animais , Reestenose Coronária/etiologia , Vasos Coronários/ultraestrutura , Modelos Animais de Doenças , Neointima , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sus scrofa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA